1.
J Vasc Interv Radiol ; 33(11): 1408-1415.e3, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35940363

RESUMO

PURPOSE: To evaluate a transmission optical spectroscopy instrument for rapid ex vivo assessment of core needle cancer biopsies (CNBs) at the point of care. MATERIALS AND METHODS: CNBs from surgically resected renal tumors and nontumor regions were scanned on their sampling trays with a custom spectroscopy instrument. After extracting principal spectral components, machine learning was used to train logistic regression, support vector machines, and random decision forest (RF) classifiers on 80% of randomized and stratified data. The algorithms were evaluated on the remaining 20% of the data set held out during training. Binary classification (tumor/nontumor) was performed based on a decision threshold. Multinomial classification was also performed to differentiate between the subtypes of renal cell carcinoma (RCC) and account for potential confounding effects from fat, blood, and necrotic tissue. Classifiers were compared based on sensitivity, specificity, and positive predictive value (PPV) relative to a histopathologic standard. RESULTS: A total of 545 CNBs from 102 patients were analyzed, yielding 5,583 spectra after outlier exclusion. At the individual spectra level, the best performing algorithm was RF with sensitivities of 96% and 92% and specificities of 90% and 89%, for the binary and multiclass analyses, respectively. At the full CNB level, RF algorithm also showed the highest sensitivity and specificity (93% and 91%, respectively). For RCC subtypes, the highest sensitivity and PPV were attained for clear cell (93.5%) and chromophobe (98.2%) subtypes, respectively. CONCLUSIONS: Ex vivo spectroscopy imaging paired with machine learning can accurately characterize renal mass CNB at the time of tissue acquisition.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Biópsia com Agulha de Grande Calibre/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Análise Espectral
2.
J Photochem Photobiol A Chem ; 316: 104-116, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26693208

RESUMO

Several classes of diversely substituted styryl type dyes have been synthesized with the goal of extending their expected fluorescent properties as much towards red as possible given the constraint that they maintain drug-like properties and retain high affinity binding to their biological target. We report on the synthesis, optical properties of a series of styryl dyes ( d1-d14 ), and the anomalous photophysical behavior of several of these Donor-Acceptor pairs separated by long conjugated π-systems ( d7-d10 ). We further describe an unusual dual emission behavior with two distinct ground state conformers which could be individually excited to locally excited (LE) and twisted intramolecular charge transfer (TICT) excited state in push-pull dye systems ( d7 , d9 and d10 ). Additionally, unexpected emission behavior in dye systems d7 and d8 wherein the amino- derivative d7 displayed a dual emission in polar medium while the N,N-dimethyl derivative d8 and other methylated derivatives d12-d14 showed only LE emission but did not show any TICT emission. Based on photophysical and nerve binding studies, we down selected compounds that exhibited the most robust fluorescent staining of nerve tissue sections. These dyes ( d7 , d9 , and d10 ) were subsequently selected for in-vivo fluorescence imaging studies in rodents using the small animal multispectral imaging instrument and the dual-mode laparoscopic instrument developed in-house.

3.
Proc Natl Acad Sci U S A ; 110(30): 12408-13, 2013 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-23821752

RESUMO

Raman spectroscopy, amplified by surface enhanced Raman scattering (SERS) nanoparticles, is a molecular imaging modality with ultra-high sensitivity and the unique ability to multiplex readouts from different molecular targets using a single wavelength of excitation. This approach holds exciting prospects for a range of applications in medicine, including identification and characterization of malignancy during endoscopy and intraoperative image guidance of surgical resection. The development of Raman molecular imaging with SERS nanoparticles is presently limited by long acquisition times, poor spatial resolution, small field of view, and difficulty in animal handling with existing Raman spectroscopy instruments. Our goal is to overcome these limitations by designing a bespoke instrument for Raman molecular imaging in small animals. Here, we present a unique and dedicated small-animal Raman imaging instrument that enables rapid, high-spatial resolution, spectroscopic imaging over a wide field of view (> 6 cm(2)), with simplified animal handling. Imaging of SERS nanoparticles in small animals demonstrated that this small animal Raman imaging system can detect multiplexed SERS signals in both superficial and deep tissue locations at least an order of magnitude faster than existing systems without compromising sensitivity.


Assuntos
Análise Espectral Raman/métodos , Animais , Feminino , Camundongos , Camundongos Nus
4.
Opt Lett ; 35(1): 67-9, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-20664675

RESUMO

We describe a simple, self-aligned confocal transmission microscopy technique based on two-photon-induced photocurrents of silicon photodiodes. Silicon detectors produce photocurrents in quadratic dependence on incident intensity under the pulsed illumination of light with wavelengths longer than 1.2 microm. We exploit this nonlinear process to reject out-of-focus background and perform depth-sectioning microscopic imaging. We demonstrate a comparable background rejection capability of the technique to linear confocal detection and present three-dimensional imaging in biological specimens.


Assuntos
Eletricidade , Microscopia Confocal/métodos , Fótons , Silício , Animais , Ratos , Retina/citologia
5.
Opt Express ; 16(12): 8670-7, 2008 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-18545580

RESUMO

A simple image-based autofocusing scheme for digital microscopy is demonstrated that uses as few as two intermediate images to bring the sample into focus. The algorithm is adapted to a commercial inverted microscope and used to automate brightfield and fluorescence imaging of histopathology tissue sections.


Assuntos
Algoritmos , Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Microscopia de Fluorescência/métodos , Reconhecimento Automatizado de Padrão/métodos , Processamento de Sinais Assistido por Computador
6.
Microsc Res Tech ; 70(7): 628-33, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17323366

RESUMO

A variety of high resolution optical microscopy techniques have been developed in recent years for basic and clinical studies of biological systems. We demonstrate a trimodal microscope combining optical coherence microscopy (OCM) with two forms of nonlinear microscopy, namely two-photon excited fluorescence (2PF) and second harmonic generation (SHG), for imaging turbid media. OCM combines the advantages of confocal detection and coherence gating for structural imaging in highly scattering tissues. Nonlinear microscopy enables the detection of biochemical species, such as elastin, NAD(P)H, and collagen. While 2PF arises from nonlinear excitation of fluorescent species, SHG is a form of nonlinear scattering observed in materials that lack a center of inversion symmetry, such as type I collagen. Characterization of the microscope showed nearly diffraction-limited spatial resolution in all modalities. Images were obtained in fish scales and excised human skin samples. The primary endogenous sources of contrast in the dermis were due to elastin autofluorescence and collagen SHG. Multimodal microscopy allows the simultaneous visualization of structural and functional information of biological systems.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Microscopia Confocal/métodos , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Animais , Células Epidérmicas , Humanos
7.
J Biomed Opt ; 11(2): 024014, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16674204

RESUMO

Spectral domain phase microscopy (SDPM) is a function extension of spectral domain optical coherence tomography. SDPM achieves exquisite levels of phase stability by employing common-path interferometry. We discuss the theory and limitations of Doppler flow imaging using SDPM, demonstrate monitoring the thermal contraction of a glass sample with nanometer per second velocity sensitivity, and apply this technique to measurement of cytoplasmic streaming in an Amoeba proteus pseudopod. We observe reversal of cytoplasmic flow induced by extracellular CaCl2, and report results that suggest parabolic flow of cytoplasm in the A. proteus pseudopod.


Assuntos
Amoeba/citologia , Amoeba/fisiologia , Corrente Citoplasmática/fisiologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fluxometria por Laser-Doppler/métodos , Microscopia de Contraste de Fase/métodos , Animais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Biochem Biophys Rep ; 5: 168-174, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28955820

RESUMO

Calculations indicate that selectively heating the extracellular media induces membrane temperature gradients that combine with electric fields and a temperature-induced reduction in the electropermeabilization threshold to potentially facilitate exogenous molecular delivery. Experiments by a wide-field, pulsed femtosecond laser with peak power density far below typical single cell optical delivery systems confirmed this hypothesis. Operating this laser in continuous wave mode at the same average power permeabilized many fewer cells, suggesting that bulk heating alone is insufficient and temperature gradients are crucial for permeabilization. This work suggests promising opportunities for a high throughput, low cost, contactless method for laser mediated exogenous molecule delivery without the complex optics of typical single cell optoinjection, for potential integration into microscope imaging and microfluidic systems.

9.
Opt Express ; 13(2): 410-6, 2005 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-19488367

RESUMO

Doppler optical coherence tomography (DOCT) is a technique for simultaneous cross-sectional imaging of tissue structure and blood flow. We derive the fundamental uncertainty limits on frequency estimation precision in DOCT using the Cramer-Rao lower bound in the case of additive (e.g., thermal, shot) noise. Experimental results from a mirror and a scattering phantom are used to verify the theoretical limits. Our results demonstrate that the stochastic nature of frequency noise influences the precision of flow imaging, and that the noise model must be selected judiciously in order to estimate the frequency precision.

10.
PLoS One ; 10(6): e0130276, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26076448

RESUMO

The ability to visualize and spare nerves during surgery is critical for avoiding chronic morbidity, pain, and loss of function. Visualization of such critical anatomic structures is even more challenging during minimal access procedures because the small incisions limit visibility. In this study, we focus on improving imaging of nerves through the use of a new small molecule fluorophore, GE3126, used in conjunction with our dual-mode (color and fluorescence) laparoscopic imaging instrument. GE3126 has higher aqueous solubility, improved pharmacokinetics, and reduced non-specific adipose tissue fluorescence compared to previous myelin-binding fluorophores. Dosing and kinetics were initially optimized in mice. A non-clinical modified Irwin study in rats, performed to assess the potential of GE3126 to induce nervous system injuries, showed the absence of major adverse reactions. Real-time intraoperative imaging was performed in a porcine model. Compared to white light imaging, nerve visibility was enhanced under fluorescence guidance, especially for small diameter nerves obscured by fascia, blood vessels, or adipose tissue. In the porcine model, nerve visualization was observed rapidly, within 5 to 10 minutes post-intravenous injection and the nerve fluorescence signal was maintained for up to 80 minutes. The use of GE3126, coupled with practical implementation of an imaging instrument may be an important step forward in preventing nerve damage in the operating room.


Assuntos
Sistema Nervoso Central/fisiologia , Laparoscopia/métodos , Nervos Periféricos/fisiologia , Coloração e Rotulagem/métodos , Traumatismos do Sistema Nervoso/prevenção & controle , Tecido Adiposo/metabolismo , Animais , Diagnóstico por Imagem , Corantes Fluorescentes/química , Laparoscópios , Masculino , Camundongos , Bainha de Mielina/fisiologia , Ratos , Ratos Sprague-Dawley , Espectrometria de Fluorescência/métodos , Suínos
11.
Nat Med ; 21(8): 955-61, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26168295

RESUMO

Colon cancer prevention currently relies on colonoscopy using white light to detect and remove polyps, but small and flat polyps are difficult to detect and frequently missed when using this technique. Fluorescence colonoscopy combined with a fluorescent probe specific for a polyp biomarker may improve polyp detection. Here we describe GE-137, a water-soluble probe consisting of a 26-amino acid cyclic peptide that binds the human tyrosine kinase c-Met conjugated to a fluorescent cyanine dye. Intravenous administration of GE-137 leads to its accumulation specifically in c-Met-expressing tumors in mice, and it is safe and well tolerated in humans. Fluorescence colonoscopy in patients receiving intravenous GE-137 enabled visualization of all neoplastic polyps that were visible with white light (38), as well as an additional nine polyps that were not visible with white light. This first-in-human pilot study shows that molecular imaging using an intravenous fluorescent agent specific for c-Met is feasible and safe, and that it may enable the detection of polyps missed by other techniques.


Assuntos
Neoplasias Colorretais/diagnóstico , Pólipos Intestinais/diagnóstico , Peptídeos Cíclicos/efeitos dos fármacos , Proteínas Proto-Oncogênicas c-met/análise , Sequência de Aminoácidos , Animais , Linhagem Celular Tumoral , Feminino , Fluorescência , Humanos , Macaca fascicularis , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Dados de Sequência Molecular
12.
Opt Express ; 12(12): 2739-45, 2004 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-19475116

RESUMO

We describe a novel second harmonic generation (SHG) microscope that employs heterodyne detection by interfering the epi directed SHG from a sample with SHG from a reference crystal. In addition, the microscope provides complementary reflectance information based on optical coherence microscopy (OCM). The instrument features dual balanced detection to minimize the effect of source fluctuations, and polarization-sensitive detection to measure the nonlinear susceptibility of the sample. Interferometric detection can potentially improve the sensitivity and thus extend the imaging depth as compared with direct detection of SHG.

13.
Arch Ophthalmol ; 121(2): 235-9, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12583790

RESUMO

BACKGROUND: Color Doppler optical coherence tomography (CDOCT) combines laser Doppler velocimetry and optical coherence tomography for simultaneous micron-scale resolution cross-sectional imaging of tissue microstructure and blood flow. Recently, CDOCT was adapted to a slitlamp biomicroscope for imaging structure and blood flow in the human retina. OBJECTIVE: To demonstrate feasibility of CDOCT for imaging retinal hemodynamics. DESIGN: Enabling CDOCT to measure retinal blood flow pulsatility in humans. SETTING: Laboratory. MAIN OUTCOME MEASURES: Time-resolved flow profiles and images of retinal blood flow dynamics for measurement of pulsatility within retinal vessels. RESULTS: Rapid sequences of images were acquired over selected vessels near the optic nerve head. From these images, retinal blood flow profiles were extracted and synchronized to an external reference obtained with a photoplethysmograph. Each profile was acquired in less than 10 milliseconds. CONCLUSIONS: Our results indicate that CDOCT provides laser Doppler information in addition to conventional optical coherence tomography, allowing the observation of blood flow dynamics simultaneous to imaging retinal structure. CDOCT is a promising technology for research and clinical studies of retinal blood flow dynamics. CLINICAL RELEVANCE: Blood flow dynamics, such as pulsatility and autoregulation, have been shown to change throughout the progression of diabetic retinopathy and glaucoma. Enabling CDOCT to observe retinal dynamics improves its potential as a clinical diagnostic tool.


Assuntos
Fluxometria por Laser-Doppler/instrumentação , Vasos Retinianos/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Humanos , Interferometria/instrumentação , Luz , Pletismografia , Fluxo Pulsátil , Fluxo Sanguíneo Regional/fisiologia , Tomografia/métodos
14.
J Biomed Opt ; 7(1): 123-9, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11818020

RESUMO

Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a novel autocorrelation technique. This Doppler processing method is compatible with a high speed OCT system capable of imaging in real time. Using this system, we demonstrate cross-sectional imaging of bidirectional flow with CDOCT at four frames per second in a tissue-simulating phantom consisting of intralipid solution flowing in glass capillaries. As a demonstration of real-time imaging of blood flow in vivo we imaged pulsatible blood flow in a rat femoral artery at eight frames per second. Issues of velocity sensitivity, imaging speed, and range of velocity measurement are discussed, as well as potential applications of real-time CDOCT.


Assuntos
Sistemas Computacionais , Óptica e Fotônica , Reologia/métodos , Tomografia , Ultrassonografia Doppler em Cores , Animais , Velocidade do Fluxo Sanguíneo , Emulsões Gordurosas Intravenosas/metabolismo , Artéria Femoral/fisiologia , Modelos Teóricos , Imagens de Fantasmas , Ratos , Fatores de Tempo
15.
J Biomed Opt ; 18(10): 106012, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24150231

RESUMO

The era of molecular medicine has ushered in the development of microscopic methods that can report molecular processes in thick tissues with high spatial resolution. A commonality in deep-tissue microscopy is the use of near-infrared (NIR) lasers with single- or multiphoton excitations. However, the relationship between different NIR excitation microscopic techniques and the imaging depths in tissue has not been established. We compared such depth limits for three NIR excitation techniques: NIR single-photon confocal microscopy (NIR SPCM), NIR multiphoton excitation with visible detection (NIR/VIS MPM), and all-NIR multiphoton excitation with NIR detection (NIR/NIR MPM). Homologous cyanine dyes provided the fluorescence. Intact kidneys were harvested after administration of kidney-clearing cyanine dyes in mice. NIR SPCM and NIR/VIS MPM achieved similar maximum imaging depth of ∼100 µm. The NIR/NIR MPM enabled greater than fivefold imaging depth (>500 µm) using the harvested kidneys. Although the NIR/NIR MPM used 1550-nm excitation where water absorption is relatively high, cell viability and histology studies demonstrate that the laser did not induce photothermal damage at the low laser powers used for the kidney imaging. This study provides guidance on the imaging depth capabilities of NIR excitation-based microscopic techniques and reveals the potential to multiplex information using these platforms.


Assuntos
Meios de Contraste/química , Corantes Fluorescentes/química , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Carbocianinas , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Meios de Contraste/farmacologia , Emulsões , Corantes Fluorescentes/farmacologia , Histocitoquímica , Processamento de Imagem Assistida por Computador/métodos , Rim/química , Rim/efeitos da radiação , Lasers , Masculino , Camundongos , Imagens de Fantasmas , Fosfolipídeos , Óleo de Soja
16.
Proc SPIE Int Soc Opt Eng ; 82072012 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-24386536

RESUMO

Fluorescence image guided surgery (FIGS) allows intraoperative visualization of critical structures, with applications spanning neurology, cardiology and oncology. An unmet clinical need is prevention of iatrogenic nerve damage, a major cause of post-surgical morbidity. Here we describe the advancement of FIGS imaging hardware, coupled with a custom nerve-labeling fluorophore (GE3082), to bring FIGS nerve imaging closer to clinical translation. The instrument is comprised of a 405 nm laser and a white light LED source for excitation and illumination. A single 90 gram color CCD camera is coupled to a 10 mm surgical laparoscope for image acquisition. Synchronization of the light source and camera allows for simultaneous visualization of reflected white light and fluorescence using only a single camera. The imaging hardware and contrast agent were evaluated in rats during in situ surgical procedures.

17.
Biomed Opt Express ; 3(8): 1880-90, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-22876351

RESUMO

Iatrogenic nerve damage is a leading cause of morbidity associated with many common surgical procedures. Complications arising from these injuries may result in loss of function and/or sensation, muscle atrophy, and chronic neuropathy. Fluorescence image-guided surgery offers a potential solution for avoiding intraoperative nerve damage by highlighting nerves that are otherwise difficult to visualize. In this work we present the development of a single camera, dual-mode laparoscope that provides near simultaneous display of white-light and fluorescence images of nerves. The capability of the instrumentation is demonstrated through imaging several types of in situ rat nerves via a nerve specific contrast agent. Full color white light and high brightness fluorescence images and video of nerves as small as 100 µm in diameter are presented.

18.
Mol Imaging Biol ; 14(6): 708-17, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22488576

RESUMO

PURPOSE: Patients suffer from complications as a result of unintentional nerve damage during surgery. We focus on improving intraoperative visualization of nerves through the use of a targeted fluorophore and optical imaging instrumentation. PROCEDURE: A myelin-targeting fluorophore, GE3111, was synthesized, characterized for its optical and myelin-binding properties using purified myelin basic protein, and evaluated in mice. Additionally, a compact instrument was adapted to visualize nerves. RESULTS: GE3111 was synthesized using a versatile methodology. Its optical properties were sensitive to the local environment both in vitro and in vivo. Following intravenous injection, central and peripheral nerves were visualized, with the kinetics of nerve uptake modifiable depending on the formulation. Fluorescence polarization showed specific and strong binding to purified myelin basic protein. Nerves were visualized in vivo using a dedicated compact imaging device requiring less than 2.5 mW/cm(2) of illumination at 405 nm. CONCLUSIONS: Fluorescence imaging of nerves through myelin showed a potential for use in image-guided surgery. Intraoperative nerve imaging is an example where contrast agent and instrument development come together as a result of clinical need.


Assuntos
Compostos de Anilina , Meios de Contraste , Diagnóstico por Imagem/métodos , Bainha de Mielina/patologia , Nervos Periféricos/patologia , Sulfonamidas , Administração Intravenosa , Compostos de Anilina/síntese química , Compostos de Anilina/química , Compostos de Anilina/farmacocinética , Animais , Bovinos , Meios de Contraste/síntese química , Meios de Contraste/química , Meios de Contraste/farmacocinética , Relação Dose-Resposta a Droga , Período Intraoperatório , Masculino , Camundongos , Proteína Básica da Mielina/metabolismo , Fenômenos Ópticos , Especificidade de Órgãos , Solventes/química , Espectrometria de Fluorescência , Sulfonamidas/síntese química , Sulfonamidas/química , Sulfonamidas/farmacocinética , Cirurgia Assistida por Computador
19.
J Phys Chem B ; 115(39): 11530-5, 2011 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-21866928

RESUMO

Two-photon (2P) optical properties of cyanine dyes were evaluated using a 2P fluorescence spectrophotometer with 1.55 µm excitation. We report the 2P characteristics of common NIR polymethine dyes, including their 2P action cross sections and the 2P excited fluorescence lifetime. One of the dyes, DTTC, showed the highest 2P action cross-section (∼103 ± 19 GM) and relatively high 2P excited fluorescence lifetime and can be used as a scaffold for the synthesis of 2P molecular imaging probes. The 2P action cross-section of DTTC and the lifetime were also highly sensitive to the solvent polarity, providing other additional parameters for its use in optical imaging and the mechanism for probing environmental factors. Overall, this study demonstrated the quantitative measurement of 2P properties of NIR dyes and established the foundation for designing molecular probes for 2P imaging applications in the NIR region.


Assuntos
Corantes/química , Animais , Rim/anatomia & histologia , Camundongos , Microscopia de Fluorescência , Fótons , Teoria Quântica , Solventes/química
20.
J Biomed Opt ; 15(2): 020509, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20459220

RESUMO

Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovascular mapping in a preclinical model of myocardial ischemia. Our system uses fiber optic delivery of laser diode excitation, custom optics with high collection efficiency, and compact consumer-grade cameras as a low-cost and compact alternative to open surgical FIGS systems. Dramatic size and weight reduction increases flexibility and access, and allows for handheld use or unobtrusive positioning over the surgical field.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Aumento da Imagem/instrumentação , Microscopia de Fluorescência/instrumentação , Isquemia Miocárdica/patologia , Isquemia Miocárdica/cirurgia , Cirurgia Assistida por Computador/instrumentação , Animais , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Miniaturização , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade