Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Magn Reson Imaging ; 39(2): 419-26, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23682041

RESUMO

PURPOSE: To prospectively evaluate comfort and image quality of prostate MRI using two different endorectal (ER) coils. MATERIALS AND METHODS: Thirty consecutive patients were prospectively randomized to receive prostate MRI using either a prostate endocoil (PEC) or colorectal endocoil (CEC). Patients and operators were surveyed with regard to endocoil placement. Four Body MRI trained radiologists rated image quality for each examination and additional selected blinded coronal T2 weighted images. RESULTS: Average patient discomfort (on a 0-10 pain scale) was greater with the PEC (5.0 for PEC and 2.7 for CEC) with a statistically significant difference (P < 0.03). Ability to identify the neurovascular bundle (NVB) was 5.8 times more likely to be rated excellent with the CEC compared with the PEC (P < 0.003). Image quality with CEC was 3.5 times more highly rated (P < 0.04). In particular, signal-to-noise ratio (SNR) with the CEC was 3.0 times more highly rated than with the PEC (P < 0.05). CONCLUSION: The smaller CEC was better tolerated by patients than the traditional PEC, and resulted in at least equivalent, and in some instances improved image quality. This may result in fewer aborted cases and lead to decreased procedural intolerance to endorectal coil MRI.


Assuntos
Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Dor/etiologia , Satisfação do Paciente , Neoplasias da Próstata/patologia , Transdutores/efeitos adversos , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Dor/prevenção & controle , Medição da Dor , Neoplasias da Próstata/complicações , Reto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
MedEdPublish (2016) ; 13: 14, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37736237

RESUMO

BACKGROUND: In the United States, patients with limited English proficiency face significant barriers to comprehending and acting upon health-related information, particularly during the COVID-19 pandemic. The ability of health professionals to communicate COVID-19-related information to Mandarin-speaking patients has proved critical in discussions about vaccine efficacy, side effects, and post-vaccine protection. METHODS: The authors created a one-hour educational module to help Mandarin-speaking medical students better convey COVID-19 vaccine information to Mandarin-only speakers. The module is composed of an educational guide, which introduced key terminology and addressed commonly asked questions, and pre- and post-surveys. The authors recruited 59 Mandarin-speaking medical students all of whom had previously completed a medical Mandarin elective. The module and surveys were distributed and completed in August 2021. Data analysis measured the change in aggregate mean for subjective five-point Likert-scale questions and change in percent accuracy for objective knowledge-based questions. RESULTS: 86.4% of participants were primary English speakers with variable levels of Mandarin proficiency. The educational module significantly improved participants' subjective comfort level in discussing the COVID-19 vaccine in English and Mandarin. The largest improvement in both English and Mandarin was demonstrated in participants' ability to explain differences between the COVID-19 vaccines, with an aggregate mean improvement of 0.39 for English and 1.48 for Mandarin. Survey respondents also demonstrated increased percent accuracy in knowledge-based objective questions in Mandarin. CONCLUSIONS: This module provides Mandarin-learning medical students with skills to deliver reliable information to the general population and acts as a model for the continued development of educational modules for multilingual medical professionals.

3.
PLoS One ; 17(8): e0272333, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35951646

RESUMO

BACKGROUND/OBJECTIVE: To evaluate the development of intra- and post-operative retinal breaks after pars plana vitrectomy (PPV) for macular hole (MH) and/or vitreomacular traction (VMT). SUBJECTS/METHODS: Medical records of patients who underwent PPV at Kellogg Eye Center between 1/1/2005-6/30/2018, were evaluated in three groups: group 1, MH/VMT (n = 136); group 2, epiretinal membrane (ERM) without VMT (n = 270); and group 3, diagnostic vitrectomy (DV) or vitreous opacities (n = 35). Statistical analyses were conducted using SAS. RESULTS: 20.6% of patients with MH/VMT, 8.5% of patients with ERM, and 5.7% of patients with DV or vitreous opacities had either intra-operative or post-operative breaks. Indication of MH/VMT versus ERM was a significant predictor for this outcome (p = .0112). The incidence of retinal breaks was higher in operations using 23-gauge versus 25-gauge PPV (25.0% vs. 7.4%, p < .0001). CONCLUSIONS: The presence of MH and/or VMT is a significant risk factor for retinal breaks from PPV, as is use of 23-gauge vitrectomy.


Assuntos
Membrana Epirretiniana , Perfurações Retinianas , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Humanos , Perfurações Retinianas/cirurgia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Tração , Transtornos da Visão/cirurgia , Vitrectomia/efeitos adversos
4.
Radiology ; 237(2): 641-6, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16170015

RESUMO

PURPOSE: To retrospectively determine the accuracy of low-dose (20-mAs) computed tomography (CT) in the diagnosis of acute appendicitis in children by using a technique that enables the simulation of human CT scans acquired at a lower tube current given the image acquired at a standard dose. MATERIALS AND METHODS: Institutional review board approval was obtained, informed consent was not required, and the study was HIPAA compliant. The authors reviewed 100 standard-dose pediatric abdominal-pelvic CT scans (50 positive and 50 negative scans) obtained in 100 patients and corresponding simulated low-dose (20-mAs) scans. The standard-dose scans were obtained for evaluation in patients suspected of having appendicitis. Scans were reviewed in randomized order by four experienced pediatric radiologists. The patients with positive findings included 21 girls (mean age, 9.2 years) and 29 boys (mean age, 8.4 years). The patients with negative findings included 28 girls (mean age, 9.2 years) and 22 boys (mean age, 8.4 years). Simulation was achieved by adding noise patterns from repeated 20-mAs scans of a pediatric pelvis phantom to the original scans obtained with a standard tube current. Observers recorded their confidence in the diagnosis of appendicitis by using a six-point scale. Dose-related changes were analyzed with generalized estimating equations and the nonparametric sign test. RESULTS: There was a statistically significant (P < .001, sign test) decrease in both sensitivity and accuracy with a lower tube current, from 91.5% with the original tube current to 77% with the lower tube current. A low dose was the only statistically significant (P < .001) risk factor for a false-negative result. The specificity was unchanged at 94% for both the images obtained with the original tube current and the simulated low-dose images. The overall accuracy decreased from 92% with the original dose to 86% with the low dose. CONCLUSION: Preliminary findings indicate that it is feasible to optimize the CT dose used to evaluate appendicitis in children by using phantom-based computer simulations.


Assuntos
Apendicite/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Adolescente , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Masculino , Doses de Radiação , Radiografia Abdominal , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA