RESUMO
Zero echo time (ZTE) sequence is recent advanced magnetic resonance technique that utilizes ultrafast readouts to capture signals from short-T2 tissues. This sequence enables T2- and T2* weighted imaging of tissues with short intrinsic relaxation times by using an extremely short TE, and are increasingly used in the musculoskeletal system. We review the imaging physics of these sequences, practical limitations, and image reconstruction, and then discuss the clinical utilities in various disorders of the musculoskeletal system. ZTE can be readily incorporated into the clinical workflow, and is a promising technique to avoid unnecessary radiation exposure, cost, and time-consuming by computed tomography in some cases. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.
Assuntos
Processamento de Imagem Assistida por Computador , Sistema Musculoesquelético , Humanos , Processamento de Imagem Assistida por Computador/métodos , Sistema Musculoesquelético/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodosRESUMO
ABSTRACT: We obtained breath-hold zero TE (ZTE) magnetic resonance imaging for the evaluation of pulmonary arteriovenous malformations before and after embolotherapy. To the best of our knowledge, there have been no reports of ZTE for the entire lung imaging in single breath-hold scan time such as 20 seconds. Breath-hold ZTE magnetic resonance imaging can be a useful technique for magnetic resonance-based follow-up of vascular lung diseases without using contrast media, reducing the undesired artifacts from metallic devices.
Assuntos
Fístula Arteriovenosa , Malformações Arteriovenosas , Embolização Terapêutica , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Humanos , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Suspensão da Respiração , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , ArtefatosRESUMO
A 60-year-old woman with a 37-year history of rheumatoid arthritis (RA) had a sudden onset of headache. Head MRI showed acute multiple infarctions in the vertebrobasilar region, and MR angiography showed stenosis of the right vertebral artery (VA). 3D-CT angiography of the craniovertebral junction showed atlantoaxial subluxation and stenosis of the right VA just distal to the transverse foramen of C2, which was due to osteophytes and degenerative changes secondary to RA. Digital subtraction angiography clearly demonstrated occlusion of the right VA during rightward head rotation. Based on those findings, rotatory instability at C1-2 was considered as the primary cause of the vertebrobasilar infarctions, and Bow Hunter's syndrome was diagnosed. The patient underwent C1-5 posterior fixation, and brain infarction has not recurred.
Assuntos
Artrite Reumatoide , Mucopolissacaridose II , Insuficiência Vertebrobasilar , Artrite Reumatoide/complicações , Artrite Reumatoide/diagnóstico por imagem , Feminino , Humanos , Infarto , Pessoa de Meia-Idade , Artéria Vertebral/diagnóstico por imagem , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/etiologiaRESUMO
BACKGROUND AND PURPOSE: Parkinson disease is a prevalent disease, with olfactory dysfunction recognized as an early nonmotor manifestation. It is sometimes difficult to differentiate Parkinson disease from atypical parkinsonism using conventional MR imaging and motor symptoms. It is also known that olfactory loss occurs to a lesser extent or is absent in atypical parkinsonism. To the best of our knowledge, no study has examined olfactory bulb changes to differentiate Parkinson disease from atypical parkinsonism, even in an early diagnosis, and its association with conventional MR imaging findings. Hence, we aimed to assess the utility of olfactory bulb measurements in differentiating Parkinson disease from atypical parkinsonism even in the early stage. MATERIALS AND METHODS: In this retrospective study, we enrolled 108 patients with Parkinson disease, 13 with corticobasal syndrome, 15 with multiple system atrophy, and 17 with progressive supranuclear palsy who developed parkinsonism. Thirty-nine age-matched healthy subjects served as controls. All subjects underwent conventional MR imaging and 3D FIESTA for olfactory bulb measurements using manual ROI quantification of the cross-sectional olfactory bulb area using the coronal plane. Bilateral olfactory bulb measurements were averaged. For group comparisons, we used the Welch t test, and we assessed diagnostic accuracy using receiver operating characteristic analysis. RESULTS: Patients with Parkinson disease had a mean olfactory bulb area of 4.2 (SD, 1.0 mm2), significantly smaller than in age-matched healthy subjects (6.6 [SD, 1.7 mm2], P < .001), and those with corticobasal syndrome (5.4 [SD, 1.2 mm2], P < .001), multiple system atrophy (6.5 [SD, 1.2 mm2], P < .001), and progressive supranuclear palsy (5.4 [SD, 1.2 mm2], P < .001). The receiver operating characteristic analysis for the olfactory bulb area measurements showed good diagnostic performance in differentiating Parkinson disease from atypical parkinsonism, with an area under the curve of 0.87, an optimal cutoff value of 5.1 mm2, and a false-positive rate of 18%. When we compared within 2 years of symptom onset, the olfactory bulb in Parkinson disease (4.2 [SD, 1.1 mm2]) remained significantly smaller than in atypical parkinsonism (versus corticobasal syndrome (6.1 [SD, 0.7 mm2]), P < .001; multiple system atrophy (6.3 [SD, 1.4 mm2]), P < .001; and progressive supranuclear palsy (5.2 [1.3 mm2], P = .003, respectively). CONCLUSIONS: 3D FIESTA-based olfactory bulb measurement holds promise for distinguishing Parkinson disease from atypical parkinsonism, especially in the early stage.
Assuntos
Imageamento por Ressonância Magnética , Bulbo Olfatório , Doença de Parkinson , Transtornos Parkinsonianos , Humanos , Bulbo Olfatório/diagnóstico por imagem , Bulbo Olfatório/patologia , Masculino , Feminino , Doença de Parkinson/diagnóstico por imagem , Idoso , Diagnóstico Diferencial , Estudos Retrospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Transtornos Parkinsonianos/diagnóstico por imagem , Imageamento Tridimensional/métodos , Sensibilidade e Especificidade , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Atrofia de Múltiplos Sistemas/diagnóstico por imagemRESUMO
PURPOSE: The purpose of our study is to develop deep convolutional neural network (DCNN) for detecting hip fractures using CT and MRI as a gold standard, and to evaluate the diagnostic performance of 7 readers with and without DCNN. METHODS: The study population consisted of 327 patients who underwent pelvic CT or MRI and were diagnosed with proximal femoral fractures. All radiographs were manually checked and annotated by radiologists referring to CT and MRI for selecting ROI. At first, a DCNN with the GoogLeNet model was trained by 302 cases. The remaining 25 cases and 25 control subjects were used for the observer performance study and for the testing of DCNN. Seven readers took part in this study. A continuous rating scale was used to record each observer's confidence level. Subsequently, each observer interpreted with the DCNN outputs and rated them again. The area under the curve (AUC) was used to compare the fracture detection. RESULTS: The average AUC of the 7 readers was 0.832. The AUC of DCNN alone was 0.905. The average AUC of the 7 readers with DCNN outputs was 0.876. The AUC of readers with DCNN output were higher than those without(pâ¯<â¯0.05). The AUC of the 2 experienced readers with DCNN output exceeded the AUC of DCNN alone. CONCLUSION: For detecting the hip fractures on radiographs, DCNN developed using CT and MRI as a gold standard by radiologists improved the diagnostic performance including the experienced readers.