Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Neurooncol ; 140(2): 341-349, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30132164

RESUMO

PURPOSE/OBJECTIVE(S): To compare the performance of five prognostic models [RTOG recursive partitioning analysis (RPA), Score Index for Radiosurgery in Brain Metastases (SIR), Barnholtz-Sloan-Kattan nomogram (BSKN), diagnosis-specific Graded Prognostic Assessment (dsGPA), and Graded Prognostic Assessment for Lung Cancer Using Molecular Markers (Lung-molGPA)] against actual survival in patients with brain metastases treated with SRS +/- WBRT. MATERIALS/METHODS: 100 consecutive patients treated with SRS +/- WBRT between January 2006 and July 2012 were retrospectively analyzed. Patients were binned according to 33 percentiles of the predicted survival distribution for the BSKN and dsGPA models to compare with LungmolGPA, RPA and SIR. Pearson's correlation coefficients between predicted and observed survival were estimated to quantify the proportion of variance in observed survival. RESULTS: Median survival for the entire cohort was 13.5 months, with predicted vs actual MS by BSKN, SIR, dsGPA, RPA, adenocarcinoma Lung-molGPA, and nonadenocarcinoma Lung-molGPA was 3.8 vs 15.6 months, 7 vs 13.5 months, 9.4 vs 13.5 months, 10.3 vs 13.5 months, 13.7 vs 13.7 months, and 9.8 vs 9.7 months, respectively. The BSKN model and adenocarcinoma LungmolGPA created three groups with a statistically significantly different MS (p = 0.002 and p = 0.01, respectively). CONCLUSION: All models under-predicted MS and only the BSKN and Lung-molGPA model stratified patients into three risk groups with statistically significant actual MS. The prognostic groupings of the adenocarcinoma Lung-molGPA group was the best predictor of MS, and showed that we are making improvements in our prognostic ability by utilizing molecular information that is much more widely available in the current treatment era.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/radioterapia , Irradiação Craniana , Radiocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Prognóstico , Estudos Retrospectivos , Análise de Sobrevida
2.
Med Phys ; 39(10): 5882-90, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23039627

RESUMO

PURPOSE: Rotational IMRT has been adopted by many clinics for its promise to deliver treatments in a shorter amount of time than other conventional IMRT techniques. In this paper, the authors investigate whether RapidArc is more susceptible to delivery uncertainties than dynamic IMRT using fixed fields. METHODS: Dosimetric effects of delivery uncertainties in dose rate, gantry angle, and MLC leaf positions were evaluated by incorporating these uncertainties into RapidArc and sliding window IMRT (SW IMRT) treatment plans for five head-and-neck and five prostate cases. Dose distributions and dose-volume histograms of original and modified plans were recalculated and compared using Gamma analysis and dose indices of planned treatment volumes (PTV) and organs at risk (OAR). Results of Gamma analyses using passing criteria ranging from 1%-1 mm up to 5%-3 mm were reported. RESULTS: Systematic shifts in MLC leaf bank positions of SW-IMRT cases resulted in 2-4 times higher average percent differences than RapidArc cases. Uniformly distributed random variations of 2 mm for active MLC leaves had a negligible effect on all dose distributions. Sliding window cases were much more sensitive to systematic shifts in gantry angle. Dose rate variations during RapidArc must be much larger than typical machine tolerances to affect dose distributions significantly; dynamic IMRT is inherently not susceptible to such variations. CONCLUSIONS: RapidArc deliveries were found to be more tolerant to variations in gantry position and MLC leaf position than SW IMRT. This may be attributed to the fact that the average segmental field size or MLC leaf opening is much larger for RapidArc. Clinically acceptable treatments may be delivered successfully using RapidArc despite large fluctuations in dose rate and gantry position.


Assuntos
Radioterapia de Intensidade Modulada/métodos , Incerteza , Artefatos , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Aceleradores de Partículas , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
3.
Med Phys ; 39(9): 5557-66, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22957622

RESUMO

PURPOSE: Dose-rate-regulated tracking (DRRT) is a tumor tracking strategy that programs the MLC to track the tumor under regular breathing and adapts to breathing irregularities during delivery using dose rate regulation. Constant-dose-rate tracking (CDRT) is a strategy that dynamically repositions the beam to account for intrafractional 3D target motion according to real-time information of target location obtained from an independent position monitoring system. The purpose of this study is to illustrate the differences in the effectiveness and delivery accuracy between these two tracking methods in the presence of breathing irregularities. METHODS: Step-and-shoot IMRT plans optimized at a reference phase were extended to remaining phases to generate 10-phased 4D-IMRT plans using segment aperture morphing (SAM) algorithm, where both tumor displacement and deformation were considered. A SAM-based 4D plan has been demonstrated to provide better plan quality than plans not considering target deformation. However, delivering such a plan requires preprogramming of the MLC aperture sequence. Deliveries of the 4D plans using DRRT and CDRT tracking approaches were simulated assuming the breathing period is either shorter or longer than the planning day, for 4 IMRT cases: two lung and two pancreatic cases with maximum GTV centroid motion greater than 1 cm were selected. In DRRT, dose rate was regulated to speed up or slow down delivery as needed such that each planned segment is delivered at the planned breathing phase. In CDRT, MLC is separately controlled to follow the tumor motion, but dose rate was kept constant. In addition to breathing period change, effect of breathing amplitude variation on target and critical tissue dose distribution is also evaluated. RESULTS: Delivery of preprogrammed 4D plans by the CDRT method resulted in an average of 5% increase in target dose and noticeable increase in organs at risk (OAR) dose when patient breathing is either 10% faster or slower than the planning day. In contrast, DRRT method showed less than 1% reduction in target dose and no noticeable change in OAR dose under the same breathing period irregularities. When ±20% variation of target motion amplitude was present as breathing irregularity, the two delivery methods show compatible plan quality if the dose distribution of CDRT delivery is renormalized. CONCLUSIONS: Delivery of 4D-IMRT treatment plans, stemmed from 3D step-and-shoot IMRT and preprogrammed using SAM algorithm, is simulated for two dynamic MLC-based real-time tumor tracking strategies: with and without dose-rate regulation. Comparison of cumulative dose distribution indicates that the preprogrammed 4D plan is more accurately and efficiently conformed using the DRRT strategy, as it compensates the interplay between patient breathing irregularity and tracking delivery without compromising the segment-weight modulation.


Assuntos
Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Respiração , Humanos , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Órgãos em Risco/efeitos da radiação , Neoplasias Pancreáticas/fisiopatologia , Neoplasias Pancreáticas/radioterapia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Reprodutibilidade dos Testes , Fatores de Tempo
4.
Med Phys ; 39(8): 5118-26, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22894437

RESUMO

PURPOSE: In intensity-modulated radiation therapy (IMRT) planning, reducing the pencil-beam size may lead to a significant improvement in dose conformity, but also increase the time needed for the dose calculation and plan optimization. The authors develop and evaluate a postoptimization refinement (POpR) method, which makes fine adjustments to the multileaf collimator (MLC) leaf positions after plan optimization, enhancing the spatial precision and improving the plan quality without a significant impact on the computational burden. METHODS: The authors' POpR method is implemented using a commercial treatment planning system based on direct aperture optimization. After an IMRT plan is optimized using pencil beams with regular pencil-beam step size, a greedy search is conducted by looping through all of the involved MLC leaves to see if moving the MLC leaf in or out by half of a pencil-beam step size will improve the objective function value. The half-sized pencil beams, which are used for updating dose distribution in the greedy search, are derived from the existing full-sized pencil beams without need for further pencil-beam dose calculations. A benchmark phantom case and a head-and-neck (HN) case are studied for testing the authors' POpR method. RESULTS: Using a benchmark phantom and a HN case, the authors have verified that their POpR method can be an efficient technique in the IMRT planning process. Effectiveness of POpR is confirmed by noting significant improvements in objective function values. Dosimetric benefits of POpR are comparable to those of using a finer pencil-beam size from the optimization start, but with far less computation and time. CONCLUSIONS: The POpR is a feasible and practical method to significantly improve IMRT-plan quality without compromising the planning efficiency.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Simulação por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Humanos , Neoplasias Orofaríngeas/radioterapia , Imagens de Fantasmas , Radiometria/métodos , Reprodutibilidade dos Testes , Distribuição Tecidual
5.
Med Phys ; 37(8): 4186-92, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20879579

RESUMO

PURPOSE: Digital tomosynthesis (DTS) recently gained extensive research interests in both diagnostic and radiation therapy fields. Conventional DTS images are generated by scanning an x-ray source and flat-panel detector pair on opposite sides of an object, with the scanning trajectory on a one-dimensional curve. A novel tomosynthesis method named solid-angle tomosynthesis (SAT) is proposed, where the x-ray source scans on an arbitrary shaped two-dimensional surface. METHODS: An iterative algorithm in the form of total variation regulated expectation maximization is developed for SAT image reconstruction. The feasibility and effectiveness of SAT is corroborated by computer simulation studies using three-dimensional (3D) numerical phantoms including a 3D Shepp-Logan phantom and a volumetric CT image set of a human breast. RESULTS: SAT is able to cover more space in Fourier domain more uniformly than conventional DTS. Greater coverage and more isotropy in the frequency domain translate to fewer artifacts and more accurately restored features in the in-plane reconstruction. CONCLUSIONS: Comparing with conventional DTS, SAT allows cone-shaped x-ray beams to project from more solid angles, thus provides more coverage in the spatial-frequency domain, resulting in better quality of reconstructed image.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Med Phys ; 37(11): 5593-603, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21158271

RESUMO

PURPOSE: Dose calculation is a key component in radiation treatment planning systems. Its performance and accuracy are crucial to the quality of treatment plans as emerging advanced radiation therapy technologies are exerting ever tighter constraints on dose calculation. A common practice is to choose either a deterministic method such as the convolution/superposition (CS) method for speed or a Monte Carlo (MC) method for accuracy. The goal of this work is to boost the performance of a hybrid Monte Carlo convolution/superposition (MCCS) method by devising a graphics processing unit (GPU) implementation so as to make the method practical for day-to-day usage. METHODS: Although the MCCS algorithm combines the merits of MC fluence generation and CS fluence transport, it is still not fast enough to be used as a day-to-day planning tool. To alleviate the speed issue of MC algorithms, the authors adopted MCCS as their target method and implemented a GPU-based version. In order to fully utilize the GPU computing power, the MCCS algorithm is modified to match the GPU hardware architecture. The performance of the authors' GPU-based implementation on an Nvidia GTX260 card is compared to a multithreaded software implementation on a quad-core system. RESULTS: A speedup in the range of 6.7-11.4x is observed for the clinical cases used. The less than 2% statistical fluctuation also indicates that the accuracy of the authors' GPU-based implementation is in good agreement with the results from the quad-core CPU implementation. CONCLUSIONS: This work shows that GPU is a feasible and cost-efficient solution compared to other alternatives such as using cluster machines or field-programmable gate arrays for satisfying the increasing demands on computation speed and accuracy of dose calculation. But there are also inherent limitations of using GPU for accelerating MC-type applications, which are also analyzed in detail in this article.


Assuntos
Neoplasias/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Gráficos por Computador , Computadores , Humanos , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Radioterapia (Especialidade)/métodos , Dosagem Radioterapêutica , Interface Usuário-Computador
7.
Med Phys ; 37(5): 1966-75, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20527530

RESUMO

PURPOSE: Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for both rigid and nonrigid respiration-induced target motion based on 4D computed tomography (4DCT) data sets. METHODS: A set of MLC apertures and weights was first optimized on a reference phase of a 4DCT data set. At each beam angle, the apertures were morphed from the reference phase to each of the remaining phases according to the relative shape changes in the beam's eye view of the target. Three different planning schemes were evaluated for two lung cases and one pancreas patient: (1) Individually optimizing each breathing phase; (2) optimizing the reference phase and shifting the optimized apertures to other breathing phases based on a rigid-body image registration; and (3) optimizing the reference phase and deforming the optimized apertures to the other phases based on the deformation and translation of target contours. Planning results using scheme 1 serves as the "gold standard" for plan quality assessment; scheme 2 is the method previously proposed in the literature; and scheme 3 is the method the authors proposed in this article. The optimization results were compared between the three schemes for all three cases. RESULTS: The proposed scheme 3 is comparable to scheme 1 in plan quality, and provides improved target coverage and conformity with similar normal tissue dose compared with scheme 2. CONCLUSIONS: Direct aperture deformation method for 4D IMRT planning improves upon methods that only consider rigid-body motion and achieves a plan quality close to that optimized for each of the phases.


Assuntos
Movimento , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Modelos Biológicos , Neoplasias Pancreáticas/fisiopatologia , Neoplasias Pancreáticas/radioterapia , Respiração , Fatores de Tempo
8.
Med Phys ; 37(6): 2435-40, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20632553

RESUMO

PURPOSE: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT). This technique, called verification of real-time tracking with EPID (VORTE), can potentially be used for both on-line and off-line quality assurance (QA) of MLC-based dynamic tumor tracking. METHODS: The shape and position of target as a function of time, which is assumed to be known, is projected onto the EPID plane. This projected sequence of apertures as a function of time (target motion) is then used as the reference. The accuracy of dynamic MLC tracking can then be assessed by how well the delivered beam follows this projected target motion without the use of a physical moving phantom. The beam apertures controlled by DRRT (aperture motion) is detected by the EPID as a function of time. The aperture motion is compared to the target motion to evaluate tracking error introduced by DRRT. The accuracy of VORTE was measured using film measurements of ten static fields. The VORTE for dynamic tumor tracking was tested with several target motions, including (1) rigid-body two-dimensional (2-D) cyclic motion in the superior-inferior direction with various period and amplitude; (2) the above 2-D cyclic motion plus cyclic deformation; and (3) 2-D cyclic motion with both deformation and rotation. For each target motion, the controlled aperture motion resulting from DRRT was acquired at approximately 8 Hz using EPID in the continuous-acquisition mode. Leaf positions in all captured frames were measured from the EPID and compared to their expected positions. The passing rate of 2 mm criteria for all leaves from all frames was calculated for each of the four patterns of tumor motion. Additionally, the root-mean-square (RMS) deviations of the centroid of the apertures between the designed and delivered beams were calculated for all three cases. RESULTS: The accuracy of MLC-leaf position determination by VORTE is 0.5 mm (1 standard deviation) by comparison to film measurements. With DRRT, the passing rates using the 2 mm criteria for all acquired frames are 100% for the 2-D displacement, 99% for the 2-D displacement with deformation, and 88% for the 2-D displacement combined with both deformation and rotation. The RMS deviations are 0.6 mm for the 2-D displacement, 1.0 mm for the 2-D displacement with deformation, and 1.1 mm for the 2-D displacement combined with both deformation and rotation. CONCLUSIONS: The VORTE can measure the accuracy of MLC-based tumor tracking without the necessity of employing a moving phantom. Moreover, it can be used for complex target motion (i.e., 2-D displacement combined with deformation and rotation) that is difficult to create with physical moving phantoms. Therefore, the VORTE and the novel QA process illustrated by this study have a great potential for verifying real-time tumor tracking.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Ecrans Intensificadores para Raios X , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Neoplasias/radioterapia , Radiografia , Radiometria/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Med Phys ; 47(9): 3928-3934, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32640039

RESUMO

PURPOSE: Studies on Lattice radiotherapy (LRT) for breast cancer have been largely lacking. This study investigates the dosimetric feasibility of using Gamma Pod, a stereotactic radiotherapy apparatus originally designed for breast SBRT, to deliver LRT to large, bulky breast tumor as a noninvasive treatment option. METHODS: The GammaPod-based LRT was simulated using Geant4 Gate Monte Carlo software. The simulated GammaPod was equipped with 5 mm diameter non-coplanar circular beams that span 28° latitudinally from 18° to 43° off the horizontal plane. Two degrees longitudinal intervals were used to simulate rotating sources. To simulate the treatments to different breast sizes, three water-equivalent hemisphere volumes with diameters of 10, 15, and 20 cm were analyzed. The lattice was planned by spacing focal points 2 cm apart in the transverse and sagittal planes and 2.5 cm in the coronal plane. This resulted in 22-172 shots for full breast treatment. The maximum dose for each individual shot was 20 Gy. The peak-to-valley dose differences and skin dose were analyzed. To verify the feasibility of delivering LRT, a test plan was created and delivered to a commercial diode array dose verification device using a clinical GammaPod system with 15 mm collimators. RESULTS: The dose profiles showed the average peak-to-valley dose percent differences of 94.10% in the 10 cm hemispherical volume, 88.95% in the 15 cm hemispherical volume, and 83.60% in the 20 cm hemispherical volume. Average skin dose was 1.27, 1.72, and 2.13 Gy for the 10, 15, and 20 cm irradiation volumes, respectively. The LRT plan delivered using a clinical GammaPod system with larger collimators verified the feasibility of LRT plan delivery. CONCLUSION: GammaPod-based lattice radiotherapy is a viable treatment option and its application can be extended to treating large bulky breast tumors.


Assuntos
Neoplasias da Mama , Radiocirurgia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
10.
Med Phys ; 36(10): 4433-9, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19928074

RESUMO

Kilovoltage x-ray projection images (kV images for brevity) are increasingly available in image guided radiotherapy (IGRT) for patient positioning. These images are two-dimensional (2D) projections of a three-dimensional (3D) object along the x-ray beam direction. Projecting a 3D object onto a plane may lead to ambiguities in the identification of anatomical structures and to poor contrast in kV images. Therefore, the use of kV images in IGRT is mainly limited to bony landmark alignments. This work proposes a novel subtraction technique that isolates a slice of interest (SOI) from a kV image with the assistance of a priori information from a previous CT scan. The method separates structural information within a preselected SOI by suppressing contributions to the unprocessed projection from out-of-SOI-plane structures. Up to a five-fold increase in the contrast-to-noise ratios (CNRs) was observed in selected regions of the isolated SOI, when compared to the original unprocessed kV image. The tomographic image via background subtraction (TIBS) technique aims to provide a quick snapshot of the slice of interest with greatly enhanced image contrast over conventional kV x-ray projections for fast and accurate image guidance of radiation therapy. With further refinements, TIBS could, in principle, provide real-time tumor localization using gantry-mounted x-ray imaging systems without the need for implanted markers.


Assuntos
Algoritmos , Artefatos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Raios X
11.
Radiother Oncol ; 88(1): 67-76, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18207595

RESUMO

PURPOSE: To compare target coverage and doses to rectum and bladder in IMRT of localized prostate cancer in the supine versus prone position, with the inclusion of image guidance. MATERIALS AND METHODS: Twenty patients with early stage localized prostate carcinoma who received external beam radiotherapy in the supine and prone positions underwent approximately 10 serial CT examinations in their respective treatment position in non-consecutive days, except for one patient who was treated prone but serially imaged supine. The prostate, bladder and rectum were contoured on all CT scans. A PTV was generated on the first scan of each patient's CT series by expanding the prostate with a 5mm margin and an IMRT plan was created. The resultant IMRT plan was then applied to that patient's remaining serial CT scans by aligning the initial CT image set with the subsequent serial CT image sets using (1) skin marks, (2) bony anatomy and (3) center of mass of the prostate. The dosimetric results from these three alignments were compared between the supine and prone groups. To account for the uncertainties associated with prostate delineation and intra-fractional geometric changes, a fictional "daily PTV" was generated by expanding the prostate with a 3mm margin on each serial CT scan. Thus, a more realistic target coverage index, V95, was quantified as the fraction of the daily PTV receiving at least 95% of the prescription dose. Dose-volume measures of the organs at risk were also compared. The fraction of the daily PTV contained by the initial PTV after each alignment method was quantified on each patient's serial CT scan, and is defined as PTV overlap index. RESULTS: As expected, alignment based on skin marks yielded unacceptable dose coverage for both groups of patients. Under bony alignment, the target coverage index, V95, was 97.3% and 93.6% for prone and supine patients (p<0.0001), respectively. The mean PTV overlap indices were 90.7% and 84.7% for prone and supine patients (p<0.0002), respectively. In the supine position 36% of cases showed a V95<95% after bony alignment, while only 12.5% of prone patients with V95<95% following bony alignment. Under soft-tissue alignment matching the center of mass of the prostate, the mean V95 was 99.3% and 98.6% (p<0.03) and the PTV overlap index was 97.7% and 94.8% (p<0.0002) for prone and supine groups, respectively. CONCLUSIONS: Soft-tissue alignment combined with 5mm planning margins is appropriate in minimizing treatment planning and delivery uncertainties in both the supine and prone positions. Alignment based on bony structures showed improved results over the use of skin marks for both supine and prone setups. Under bony alignment, the dose coverage and PTV overlap index for prone setup were statistically better than for supine setup, illustrating a more consistent geometric relationship between the prostate and the pelvic bony structures when patients were treated in the prone position.


Assuntos
Decúbito Ventral/fisiologia , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Decúbito Dorsal/fisiologia , Humanos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Radiografia Intervencionista , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Reto/efeitos da radiação , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Bexiga Urinária/efeitos da radiação
12.
Med Phys ; 35(12): 5233-41, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19175082

RESUMO

Intensity modulated radiation therapy (IMRT) is an advanced form of external beam radiation therapy. IMRT offers an additional dimension of freedom as compared with field shaping in three-dimensional conformal radiation therapy because the radiation intensities within a radiation field can be varied according to the preferences of locations within a given beam direction from which the radiation is directed to the tumor. This added freedom allows the treatment planning system to better shape the radiation doses to conform to the target volume while sparing surrounding normal structures. The resulting dosimetric advantage has shown to translate into clinical advantages of improving local and regional tumor control. It also offers a valuable mechanism for dose escalation to tumors while simultaneously reducing radiation toxicities to the surrounding normal tissue and sensitive structures. In less than a decade, IMRT has become common practice in radiation oncology. Looking forward, the authors wonder if IMRT has matured to such a point that the room for further improvement has diminished and so it is pertinent to ask what the future will hold for IMRT. This article attempts to look from the perspective of the current state of the technology to predict the immediate trends and the future directions. This article will (1) review the clinical experience of IMRT; (2) review what we learned in IMRT planning; (3) review different treatment delivery techniques; and finally, (4) predict the areas of advancements in the years to come.


Assuntos
Neoplasias/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Desenho de Equipamento , Humanos , Radioterapia (Especialidade)/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/tendências , Reprodutibilidade dos Testes , Software , Resultado do Tratamento
13.
Med Phys ; 35(9): 3955-62, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18841846

RESUMO

The authors have developed a new method for real-time tumor tracking with dynamic multileaf-collimator (MLC) motion under condition of free breathing. Unlike other previously proposed tumor-tracking methods, their new method uses a preprogrammed dynamic MLC sequence in combination with real-time dose-rate control. This new scheme circumvents the technical challenge in MLC-based tumor tracking of having to control the MLC motion in real time, based on real-time detected tumor motion. With their new method, the movement of the tumor, as a function of breathing phase, amplitude, or tidal volume, is reflected in the preprogrammed MLC sequence. The irregularity of breathing during treatment is handled by real-time regulation of the machine dose rate, which effectively speeds up or slows down the delivery of radiation as needed. This method is based on the fact that all of the parameters in dynamic radiation delivery, including MLC motion, are enslaved to the cumulative dose, which, in turn, can be accelerated or decelerated by varying the dose rate. Because commercially available MLC systems do not allow the MLC delivery sequence to be modified in real time based on the patient's breathing signal, previously proposed tumor-tracking techniques using a MLC cannot be readily implemented in the clinic today. By using a preprogrammed MLC sequence to handle the required motion, the task for real-time control is greatly simplified. With their new scheme, which they call dose-rate-regulated tracking (DRRT), it is possible to use existing linear accelerators that have dynamic MLC capability to achieve real-time tumor tracking, provided that the beam dose rate can be controlled externally. Tracking-error evaluation for 13 patients out of 14 resulted in a tracking error of less than 1 mm (1 sigma), if the effect of the response time of the treatment machine on the dose-rate modulation can be neglected. Film measurements on a moving phantom with variable breathing patterns and DRRT delivery showed that 97% of the measurement points have gamma values less than 1 (for 3% and 2-mm criteria), while non-DRRT delivery showed only 87%. This study shows that real-time tracking is feasible with DRRT even when the patient breathing frequency is irregular. Effects of the variation of breathing amplitude and of base line drift on the tracking error with DRRT are discussed; pending further study, a criterion is suggested for patient selection in the application of this new technique in the clinic.


Assuntos
Movimento (Física) , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Planejamento da Radioterapia Assistida por Computador/instrumentação
14.
Med Phys ; 35(1): 61-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18293562

RESUMO

Intensity-modulated arc therapy (IMAT) is a rotational IMRT technique. It uses a set of overlapping or nonoverlapping arcs to create a prescribed dose distribution. Despite its numerous advantages, IMAT has not gained widespread clinical applications. This is mainly due to the lack of an effective IMAT leaf-sequencing algorithm that can convert the optimized intensity patterns for all beam directions into IMAT treatment arcs. To address this problem, we have developed an IMAT leaf-sequencing algorithm and software using graph algorithms in computer science. The input to our leaf-sequencing software includes (1) a set of (continuous) intensity patterns optimized by a treatment planning system at a sequence of equally spaced beam angles (typically 10 degrees apart), (2) a maximum leaf motion constraint, and (3) the number of desired arcs, k. The output is a set of treatment arcs that best approximates the set of optimized intensity patterns at all beam angles with guaranteed smooth delivery without violating the maximum leaf motion constraint. The new algorithm consists of the following key steps. First, the optimized intensity patterns are segmented into intensity profiles that are aligned with individual MLC leaf pairs. Then each intensity profile is segmented into k MLC leaf openings using a k-link shortest path algorithm. The leaf openings for all beam angles are subsequently connected together to form 1D IMAT arcs under the maximum leaf motion constraint using a shortest path algorithm. Finally, the 1D IMAT arcs are combined to form IMAT treatment arcs of MLC apertures. The performance of the implemented leaf-sequencing software has been tested for four treatment sites (prostate, breast, head and neck, and lung). In all cases, our leaf-sequencing algorithm produces efficient and highly conformal IMAT plans that rival their counterpart, the tomotherapy plans, and significantly improve the IMRT plans. Algorithm execution times ranging from a few seconds to 2 min are observed on a laptop computer equipped with a 2.0 GHz Pentium M processor.


Assuntos
Algoritmos , Radioterapia de Intensidade Modulada/métodos , Simulação por Computador , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/radioterapia , Feminino , Cabeça/diagnóstico por imagem , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Masculino , Pescoço/diagnóstico por imagem , Próstata/diagnóstico por imagem , Radiografia , Planejamento da Radioterapia Assistida por Computador , Software , Tomografia
15.
Med Phys ; 35(8): 3607-15, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18777921

RESUMO

Ability of online adaptive replanning is desirable to correct for interfraction anatomic changes. A full-scope replanning/reoptimization with the current planning techniques takes too long to be practical. A novel online replanning strategy to correct for interfraction anatomic changes in real time is presented. The scheme consists of three steps: (1) rapidly delineating targets and organs at risk on the computed tomography of the day by modifying original planning contours using robust tools in a semiautomatic manner, (2) online segment aperture morphing (SAM) (adjusting beam/ segment apertures) by applying the spatial relationship between the planning target contour and the apertures to the new target contour, and (3) performing segment weight optimization (SWO) for the new apertures if necessary. The entire scheme was tested for direct-aperture-based IMRT on representative prostate and abdomen cases. Dose volume histograms obtained with the online scheme are practically equivalent to those obtained with full-scope reoptimization. For the days of small to moderate organ deformations, only the SAM is necessary, while for the large deformation days, both SAM and SWO are required to adequately account for the deformation. Both the SAM and SWO programs can be completed within 1 min, and the overall process can be completed within 10 min. The proposed SAM-SWO scheme is practically comparable to full-scope reoptimization, but is fast enough to be implemented for on-line adaptive replanning, enabling dose-guided RT.


Assuntos
Neoplasias Pancreáticas , Neoplasias da Próstata , Radiografia Abdominal/efeitos da radiação , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Automação , Fracionamento da Dose de Radiação , Humanos , Masculino , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/radioterapia , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Doses de Radiação , Reto/diagnóstico por imagem , Reto/patologia , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia
16.
Phys Med Biol ; 53(16): 4269-83, 2008 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-18653925

RESUMO

A systematic study on the sources of drift in a turbine-based spirometer (VMM-400) is presented. The study utilized an air-tight cylinder to pump air through the spirometer in a precise and programmable manner. Factors contributing to the drift were isolated and quantified. The drift due to imbalance in the electronics and the mechanical blade increased from 1% per breathing cycle to as much as 10% when the flow rate decreased from 0.24 to 0.08 l s(-1). A temperature difference of 16 degrees between the ambient and the air in the cylinder contributed about 3.5%. Most significantly, a difference in the breathing between inhalation and exhalation could produce a drift of 40% per breathing cycle, or even higher, depending on the extent of the breathing asymmetry. The origin of this drift was found to be rooted in the differential response of the spirometer to the different flow rate. Some ideas and suggestions for a correction strategy are provided for future work. The present work provides an important first step for eventual utilization of a spirometer as a stand-alone breathing surrogate for gating or tracking radiation therapy.


Assuntos
Artefatos , Análise de Falha de Equipamento , Espirometria/instrumentação , Desenho de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Phys Med Biol ; 53(17): 4733-46, 2008 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-18701770

RESUMO

Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5 degrees -10 degrees . But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently interpolated into finer angular intervals for dose calculation to mimic the continuous arc delivery. Since MCKS uses random sampling of photons, the dose computation time only increased insignificantly for the interpolated-static-beam plans that may involve up to 720 beams. Ten past IMRT cases were selected for this study. Each case took approximately 15-30 min to compute on a single CPU running Mac OS X using the MCKS method. The need for a finer beam spacing is dictated by how fast the beam weights and aperture shapes change between the adjacent static planning beam angles. MCKS, however, obviates the concern by allowing hundreds of beams to be calculated in practically the same time as for a few beams. For more than 43 beams, MCKS usually takes less CPU time than the collapsed-cone algorithm used by the Pinnacle(3) planning system.


Assuntos
Imageamento Tridimensional/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Computadores , Humanos , Modelos Estatísticos , Método de Monte Carlo , Fótons , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Software , Processos Estocásticos
18.
Phys Med Biol ; 53(22): 6291-303, 2008 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-18936519

RESUMO

Arc-modulated radiation therapy (AMRT) is a novel rotational intensity-modulated radiation therapy (IMRT) technique developed for a clinical linear accelerator that aims to deliver highly conformal radiation treatment using just one arc of gantry rotation. Compared to fixed-gantry IMRT and the multiple-arc intensity-modulated arc therapy (IMAT) techniques, AMRT promises the same treatment quality with a single-arc delivery. In this paper, we present a treatment planning scheme for AMRT, which addresses the challenges in inverse planning, leaf sequencing and dose calculation. The feasibility and performance of this AMRT treatment planning scheme have been verified with multiple clinical cases of various sites on Varian linear accelerators.


Assuntos
Radioterapia de Intensidade Modulada/métodos , Estudos de Viabilidade , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Software
19.
Med Dosim ; 32(2): 92-101, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17472888

RESUMO

The localization of treatment targets is of utmost importance for patients receiving stereotactic body radiation therapy (SBRT), where the dose per fraction is large. While both setup or respiration-induced motion components affect the localization of the treatment volume, the purpose of this work is to describe our management of the intrafraction localization uncertainty induced by normal respiration. At our institution, we have implemented gated computed tomography (CT) acquisition with an active breathing control system (ABC), and 4-dimensional (4D) CT using a skin-based marker and retrospective respiration phase-based image sorting. During gated simulation, 3D CT images were acquired corresponding to end-inhalation and end-exhalation. For 4D CT imaging, 3D CT images were acquired corresponding to 8 phases of the respiratory cycle. In addition to gated or 4D CT images, we acquired a conventional free-breathing CT (FB). For both gated and 4D CT images, the target contours were registered to the FB scan in the planning system. These contours were then combined in the FB image set to form the internal target volume (ITV). Dynamic conformal arc treatment plans were generated for the ITV using the FB scan and the gated or 4D scans with an additional 7-mm margin for patient setup uncertainty. We have described our results for a pancreas and a lung tumor case. Plans were normalized so that the PTV received 95% of the prescription dose. The dose distribution for all the critical structures in the pancreas and lung tumor cases resulted in increased sparing when the ITV was defined using gated or 4D CT images than when the FB scan was used. Our results show that patient-specific target definition using gated or 4D CT scans lead to improved normal tissue sparing.


Assuntos
Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pancreáticas/radioterapia
20.
Phys Med Biol ; 62(4): 1480-1500, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28052050

RESUMO

This study introduces a practical four-dimensional (4D) planning scheme of IMAT using 4D computed tomography (4D CT) for planning tumor tracking with dynamic multileaf beam collimation. We assume that patients can breathe regularly, i.e. the same way as during 4D CT with an unchanged period and amplitude, and that the start of 4D-IMAT delivery can be synchronized with a designated respiratory phase. Each control point of the IMAT-delivery process can be associated with an image set of 4D CT at a specified respiratory phase. Target is contoured at each respiratory phase without a motion-induced margin. A 3D-IMAT plan is first optimized on a reference-phase image set of 4D CT. Then, based on the projections of the planning target volume in the beam's eye view at different respiratory phases, a 4D-IMAT plan is generated by transforming the segments of the optimized 3D plan by using a direct aperture deformation method. Compensation for both translational and deformable tumor motion is accomplished, and the smooth delivery of the transformed plan is ensured by forcing connectivity between adjacent angles (control points). It is envisioned that the resultant plans can be delivered accurately using the dose rate regulated tracking method which handles breathing irregularities (Yi et al 2008 Med. Phys. 35 3955-62).This planning process is straightforward and only adds a small step to current clinical 3D planning practice. Our 4D planning scheme was tested on three cases to evaluate dosimetric benefits. The created 4D-IMAT plans showed similar dose distributions as compared with the 3D-IMAT plans on a single static phase, indicating that our method is capable of eliminating the dosimetric effects of breathing induced target motion. Compared to the 3D-IMAT plans with large treatment margins encompassing respiratory motion, our 4D-IMAT plans reduced radiation doses to surrounding normal organs and tissues.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA