Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 311(2): e231879, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771185

RESUMO

Background Multiparametric MRI (mpMRI) is effective for detecting prostate cancer (PCa); however, there is a high rate of equivocal Prostate Imaging Reporting and Data System (PI-RADS) 3 lesions and false-positive findings. Purpose To investigate whether fluorine 18 (18F) prostate-specific membrane antigen (PSMA) 1007 PET/CT after mpMRI can help detect localized clinically significant PCa (csPCa), particularly for equivocal PI-RADS 3 lesions. Materials and Methods This prospective study included participants with elevated prostate-specific antigen (PSA) levels referred for prostate mpMRI between September 2020 and February 2022. 18F-PSMA-1007 PET/CT was performed within 30 days of mpMRI and before biopsy. PI-RADS category and level of suspicion (LOS) were assessed. PI-RADS 3 or higher lesions at mpMRI and/or LOS 3 or higher lesions at 18F-PSMA-1007 PET/CT underwent targeted biopsies. PI-RADS 2 or lower and LOS 2 or lower lesions were considered nonsuspicious and were monitored during a 1-year follow-up by means of PSA testing. Diagnostic accuracy was assessed, with histologic examination serving as the reference standard. International Society of Urological Pathology (ISUP) grade 2 or higher was considered csPCa. Results Seventy-five participants (median age, 67 years [range, 52-77 years]) were assessed, with PI-RADS 1 or 2, PI-RADS 3, and PI-RADS 4 or 5 groups each including 25 participants. A total of 102 lesions were identified, of which 80 were PI-RADS 3 or higher and/or LOS 3 or higher and therefore underwent targeted biopsy. The per-participant sensitivity for the detection of csPCa was 95% and 91% for mpMRI and 18F-PSMA-1007 PET/CT, respectively, with respective specificities of 45% and 62%. 18F-PSMA-1007 PET/CT was used to correctly differentiate 17 of 26 PI-RADS 3 lesions (65%), with a negative and positive predictive value of 93% and 27%, respectively, for ruling out or detecting csPCa. One additional significant and one insignificant PCa lesion (PI-RADS 1 or 2) were found at 18F-PSMA-1007 PET/CT that otherwise would have remained undetected. Two participants had ISUP 2 tumors without PSMA uptake that were missed at PET/CT. Conclusion 18F-PSMA-1007 PET/CT showed good sensitivity and moderate specificity for the detection of csPCa and ruled this out in 93% of participants with PI-RADS 3 lesions. Clinical trial registration no. NCT04487847 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Assuntos
Radioisótopos de Flúor , Imageamento por Ressonância Magnética Multiparamétrica , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Niacinamida/análogos & derivados , Oligopeptídeos , Compostos Radiofarmacêuticos , Próstata/diagnóstico por imagem , Sensibilidade e Especificidade
2.
Eur Radiol ; 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38907886

RESUMO

OBJECTIVES: To assess 3-Tesla (3-T) ultra-small superparamagnetic iron oxide (USPIO)-enhanced MRI in detecting lymph node (LN) metastases for resectable adenocarcinomas of the pancreas, duodenum, or periampullary region in a node-to-node validation against histopathology. METHODS: Twenty-seven consecutive patients with a resectable pancreatic, duodenal, or periampullary adenocarcinoma were enrolled in this prospective single expert centre study. Ferumoxtran-10-enhanced 3-T MRI was performed pre-surgery. LNs found on MRI were scored for suspicion of metastasis by two expert radiologists using a dedicated scoring system. Node-to-node matching from in vivo MRI to histopathology was performed using a post-operative ex vivo 7-T MRI of the resection specimen. Sensitivity and specificity were calculated using crosstabs. RESULTS: Eighteen out of 27 patients (median age 65 years, 11 men) were included in the final analysis (pre-surgery withdrawal n = 4, not resected because of unexpected metastases peroperatively n = 2, and excluded because of inadequate contrast-agent uptake n = 3). On MRI 453 LNs with a median size of 4.0 mm were detected, of which 58 (13%) were classified as suspicious. At histopathology 385 LNs with a median size of 5.0 mm were found, of which 45 (12%) were metastatic. For 55 LNs node-to-node matching was possible. Analysis of these 55 matched LNs, resulted in a sensitivity and specificity of 83% (95% CI: 36-100%) and 92% (95% CI: 80-98%), respectively. CONCLUSION: USPIO-enhanced MRI is a promising technique to preoperatively detect and localise LN metastases in patients with pancreatic, duodenal, or periampullary adenocarcinoma. CLINICAL RELEVANCE STATEMENT: Detection of (distant) LN metastases with USPIO-enhanced MRI could be used to determine a personalised treatment strategy that could involve neoadjuvant or palliative chemotherapy, guided resection of distant LNs, or targeted radiotherapy. REGISTRATION: The study was registered on clinicaltrials.gov NCT04311047. https://clinicaltrials.gov/ct2/show/NCT04311047?term=lymph+node&cond=Pancreatic+Cancer&cntry=NL&draw=2&rank=1 . KEY POINTS: LN metastases of pancreatic, duodenal, or periampullary adenocarcinoma cannot be reliably detected with current imaging. This technique detected LN metastases with a sensitivity and specificity of 83% and 92%, respectively. MRI with ferumoxtran-10 is a promising technique to improve preoperative staging in these cancers.

3.
BJU Int ; 129(4): 480-490, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34358388

RESUMO

OBJECTIVE: To assess the outcomes of pre-biopsy magnetic resonance imaging (MRI) pathways, as a tool in biopsy-naïve men with suspicion of prostate cancer, in routine clinical practice. Secondary outcomes included a comparison of transrectal MRI-directed biopsy (TR-MRDB) and transperineal (TP)-MRDB in men with suspicious MRI. PATIENTS AND METHODS: We retrospectively assessed a two-centre cohort of consecutive biopsy-naïve men with suspicion of prostate cancer who underwent a Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) compliant pre-biopsy MRI in a single, high-volume centre between 2015 and 2019 (Centre 1). Men with suspicious MRI scans underwent TR-MRDB in Centre 1 and TP-MRDB with additional random biopsies (RB) in Centre 2. The MRI and histopathology were assessed in the same institution (Centre 1). Outcomes included: (i) overall detection rates of Grade Group (GG) 1, GG ≥2, and GG ≥3 cancer in men with suspicious MRI; (ii) Biopsy-avoidance due to non-suspicious MRI; and (iii) Cancer detection rates and biopsy-related complications between TR- and TP-MRDB. To reduce confounding bias for MRDB comparisons, inverse probability weighting (IPW) was performed for age, digital rectal examination, prostate-specific antigen (PSA), prostate volume, PSA density, and PI-RADS category. RESULTS: Of the 2597 men included, the overall GG 1, GG ≥2, and GG ≥3 prevalence was 8% (210/2597), 27% (697/2597), and 15% (396/2597), respectively. Biopsy was avoided in 57% (1488/2597) of men. After IPW, the GG 1, GG ≥2 and GG ≥3 detection rates after TR- and TP-MRDB were comparable at 24%, 57%, and 32%; and 18%, 64%, and 38%, respectively; with mean differences of -5.7% (95% confidence interval [CI] -13% to 1.4%), 6.1% (95% CI -2.1% to 14%), and 5.7% (95% CI -1.7% to 13%). Complications were similar in TR-MRDB (0.50%) and TP-MRDB with RB (0.62%; mean difference 0.11%, 95% CI -0.87% to 1.1%). CONCLUSION: This high-volume, two-centre study shows pre-biopsy MRI as a decision tool is implementable in daily clinical practice. Compared to recent trials, a substantially higher biopsy avoidance rate was achieved without compromising GG ≥2/GG ≥3 detection and coinciding with lower over detection rates of GG 1 cancer. Prostate cancer detection and complication rates were comparable for TR- and TP-MRDB.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
4.
BMC Cancer ; 20(1): 884, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32928177

RESUMO

BACKGROUND: In recent years, there is increasing evidence showing a beneficial outcome (e.g. progression free survival; PFS) after metastases-directed therapy (MDT) with external beam radiotherapy (EBRT) or targeted surgery for oligometastatic hormone sensitive prostate cancer (oHSPC). However, many patients do not qualify for these treatments due to prior interventions or tumor location. Such oligometastatic patients could benefit from radioligand therapy (RLT) with 177Lu-PSMA; a novel tumor targeting therapy for end-stage metastatic castration-resistant prostate cancer (mCRPC). Especially because RLT could be more effective in low volume disease, such as the oligometastatic status, due to high uptake of radioligands in smaller lesions. To test the hypothesis that 177Lu-PSMA is an effective treatment in oHSPC to prolong PFS and postpone the need for androgen deprivation therapy (ADT), we initiated a multicenter randomized clinical trial. This is globally, the first prospective study using 177Lu-PSMA-I&T in a randomized multicenter setting. METHODS & DESIGN: This study compares 177Lu-PSMA-I&T MDT to the current standard of care (SOC); deferred ADT. Fifty-eight patients with oHSPC (≤5 metastases on PSMA PET) and high PSMA uptake (SUVmax > 15, partial volume corrected) on 18F-PSMA PET after prior surgery and/or EBRT and a PSA doubling time of < 6 months, will be randomized in a 1:1 ratio. The patients randomized to the interventional arm will be eligible for two cycles of 7.4GBq 177Lu-PSMA-I&T at a 6-week interval. After both cycles, patients are monitored every 3 weeks (including adverse events, QoL- and xerostomia questionnaires and laboratory testing) at the outpatient clinic. Twenty-four weeks after cycle two an end of study evaluation is planned together with another 18F-PSMA PET and (whole body) MRI. Patients in the SOC arm are eligible to receive 177Lu-PSMA-I&T after meeting the primary study objective, which is the fraction of patients who show disease progression during the study follow up. A second primary objective is the time to disease progression. Disease progression is defined as a 100% increase in PSA from baseline or clinical progression. DISCUSSION: This is the first prospective randomized clinical study assessing the therapeutic efficacy and toxicity of 177Lu-PSMA-I&T for patients with oHSPC. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT04443062 .


Assuntos
Lutécio/administração & dosagem , Neoplasias Hormônio-Dependentes/tratamento farmacológico , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Neoplasias da Próstata/tratamento farmacológico , Radioisótopos/administração & dosagem , Antagonistas de Androgênios/administração & dosagem , Antagonistas de Androgênios/efeitos adversos , Progressão da Doença , Hormônios/genética , Hormônios/metabolismo , Humanos , Lutécio/efeitos adversos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias Hormônio-Dependentes/patologia , Neoplasias Hormônio-Dependentes/radioterapia , Intervalo Livre de Progressão , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Neoplasias de Próstata Resistentes à Castração/patologia , Neoplasias de Próstata Resistentes à Castração/radioterapia , Qualidade de Vida , Radioisótopos/efeitos adversos , Compostos Radiofarmacêuticos/administração & dosagem , Resultado do Tratamento
5.
Radiology ; 273(3): 879-86, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25061830

RESUMO

PURPOSE: To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. MATERIALS AND METHODS: This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 µg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. RESULTS: Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. CONCLUSION: This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence.


Assuntos
Biópsia por Agulha , Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata/patologia , Idoso , Algoritmos , Automação , Meios de Contraste , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Compostos Organometálicos , Reto , Fatores de Tempo
6.
Acta Neurochir Suppl ; 116: 187-91, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23417478

RESUMO

The introduction of 3 T magnetic resonance imaging (MRI) scanners for neuro-oncological diagnostics showed a general improvement of image quality, especially in terms of the detection and differentiation of intracranial tumors. Among the advantages of 3 T scanners compared to 1.5 T scanners are the possibility of higher spatial image resolution or shorter investigation times and the availability of functional imaging in sufficient quality. Consequently, the use of 3 T MRI for radiosurgery planning is highly desired. Functional MRI techniques (perfusion-weighted imaging, dynamic contrast-enhanced MRI, MR spectroscopy, diffusion-weighted imaging, and diffusion tensor imaging) available at 3 T scanners provide not only better detection and differentiation but also significantly better delineation of intracranial tumors, which is a crucial feature for successful radiosurgical treatment planning. The use of multimodal morphological and functional MRI methods allows identification of the biologically most active parts of the tumors with consecutive changes in therapy planning. On the other hand, there are increased geometric distortions on MRI scans obtained at 3 T compared to 1.5 T, which makes their use limited for now. However, the newest studies show an acceptable degree of geometric distortion on the 3 T planning images using special imaging protocols, while additional investigations on this issue are needed to find the optimal technical solution.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/cirurgia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Meios de Contraste , Humanos , Espectroscopia de Ressonância Magnética , Oxigênio/sangue
7.
Int J Mol Sci ; 14(7): 13842-75, 2013 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-23823804

RESUMO

Knowledge on lymph node metastases is crucial for the prognosis and treatment of prostate cancer patients. Conventional anatomic imaging often fails to differentiate benign from metastatic lymph nodes. Pelvic lymph node dissection is an invasive technique and underestimates the extent of lymph node metastases. Therefore, there is a need for more accurate non-invasive diagnostic techniques. Molecular and functional imaging has been subject of research for the last decades, in this respect. Therefore, in this article the value of imaging techniques to detect lymph node metastases is reviewed. These techniques include scintigraphy, sentinel node imaging, positron emission tomography/computed tomography (PET/CT), diffusion weighted magnetic resonance imaging (DWI MRI) and magnetic resonance lymphography (MRL). Knowledge on pathway and size of lymph node metastases has increased with molecular and functional imaging. Furthermore, improved detection and localization of lymph node metastases will enable (focal) treatment of the positive nodes only.


Assuntos
Linfonodos/patologia , Imagem Molecular/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/patologia , Humanos , Metástase Linfática , Linfografia/métodos , Masculino
8.
Med Phys ; 50(6): 3475-3489, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36879348

RESUMO

BACKGROUND: Among available breast biopsy techniques, ultrasound (US)-guided biopsy is preferable because it is relatively inexpensive and provides live imaging feedback. The availability of magnetic resonance imaging (MRI)-3D US image fusion would facilitate US-guided biopsy even for US occult lesions to reduce the need for expensive and time-consuming MRI-guided biopsy. In this paper, we propose a novel Automated Cone-based Breast Ultrasound Scanning and Biopsy System (ACBUS-BS) to scan and biopsy breasts of women in prone position. It is based on a previously developed system, called ACBUS, that facilitates MRI-3D US image fusion imaging of the breast employing a conical container filled with coupling medium. PURPOSE: The purpose of this study was to introduce the ABCUS-BS system and demonstrate its feasibility for biopsy of US occult lesions. METHOD: The biopsy procedure with the ACBUS-BS comprises four steps: target localization, positioning, preparation, and biopsy. The biopsy outcome can be impacted by 5 types of errors: due to lesion segmentation, MRI-3D US registration, navigation, lesion tracking during repositioning, and US inaccuracy (due to sound speed difference between the sample and the one used for image reconstruction). For the quantification, we use a soft custom-made polyvinyl alcohol phantom (PVA) containing eight lesions (three US-occult and five US-visible lesions of 10 mm in diameter) and a commercial breast mimicking phantom with a median stiffness of 7.6 and 28 kPa, respectively. Errors of all types were quantified using the custom-made phantom. The error due to lesion tracking was also quantified with the commercial phantom. Finally, the technology was validated by biopsying the custom-made phantom and comparing the size of the biopsied material to the original lesion size. The average size of the 10-mm-sized lesions in the biopsy specimen was 7.00 ± 0.92 mm (6.33 ± 1.16 mm for US occult lesions, and 7.40 ± 0.55 mm for US-visible lesions). RESULTS: For the PVA phantom, the errors due to registration, navigation, lesion tracking during repositioning, and US inaccuracy were 1.33, 0.30, 2.12, and 0.55 mm. The total error was 4.01 mm. For the commercial phantom, the error due to lesion tracking was estimated at 1.10 mm, and the total error was 4.11 mm. Given these results, the system is expected to successfully biopsy lesions larger than 8.22 mm in diameter. Patient studies will have to be carried out to confirm this in vivo. CONCLUSION: The ACBUS-BS facilitates US-guided biopsy of lesions detected in pre-MRI and therefore might offer a low-cost alternative to MRI-guided biopsy. We demonstrated the feasibility of the approach by successfully taking biopsies of five US-visible and three US-occult lesions embedded in a soft breast-shaped phantom.


Assuntos
Neoplasias da Mama , Biópsia Guiada por Imagem , Humanos , Feminino , Estudos de Viabilidade , Ultrassonografia , Biópsia Guiada por Imagem/métodos , Mama/diagnóstico por imagem , Biópsia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia de Intervenção/métodos , Neoplasias da Mama/diagnóstico por imagem
9.
Invest Radiol ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37975702

RESUMO

OBJECTIVES: Two advanced imaging modalities used to detect lymph node (LN) metastases in prostate cancer patients are prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography and ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging (MRI). As these modalities use different targets, a subnodal comparison is needed to interpret both their correspondence and their differences. The aim of this explorative study was to compare ex vivo 111In-PSMA µSPECT images with high-resolution 7 T USPIO µMR images and histopathology of resected LN specimens from prostate cancer patients to assess the degree of correspondence at subnodal level. MATERIALS AND METHODS: Twenty primary prostate cancer patients who underwent pelvic LN dissection were included and received USPIO contrast and 111In-PSMA. A total of 41 LNs of interest (LNOIs) were selected for ex vivo imaging based on γ-probe detection or palpation. µSPECT and µMRI acquisition were performed immediately after resection. Overlay of µSPECT images on MR images was performed, and the level of correspondence (LoC) between µSPECT and µMR findings was assessed according to a 4-point Likert classification scheme. RESULTS: Forty-one LNOIs could be matched to an LN on ex vivo µMRI. Coregistration of µSPECT and USPIO-enhanced water-selective multigradient echo MR images was successful for all 41 LNOIs. Ninety percent of the lesions showed excellent correspondence regarding the presence of metastatic tissue and affected subnodal site (LoC 4; 37/41). In only 1 of 41 LNOIs, a small metastasis was misclassified by both techniques. Three LNOIs were classified as LoC 3 (7%) and 1 LNOI as LoC 2. All LoC 2 and LoC 3 lesions had PSMA-expressing metastases on final histopathology. CONCLUSIONS: Coregistration of µSPECT and USPIO-µMRI showed excellent subnodal correspondence in the majority (90%) of LNs. Ex vivo imaging may thus help localize small cancer deposits within resected LNs and could contribute to improved interpretation of in vivo imaging of LNs.

10.
Eur Urol Focus ; 8(6): 1802-1808, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35337778

RESUMO

BACKGROUND: Patients with renal impairment cannot undergo angiography because iodine and gadolinium contrast agents are contraindicated. Iron-containing ultrasmall superparamagnetic iron oxide particles, such as ferumoxtran-10, are not contraindicated in these patients. Thus, patients with renal failure can still undergo angiography with ferumoxtran-10. OBJECTIVE: To evaluate the visibility of pelvic vessels with magnetic resonance angiography (MRA) using ferumoxtran-10 as contrast agent. DESIGN, SETTING, AND PARTICIPANTS: Three hundred and eighty-one patients diagnosed with primary or recurrent prostate cancer underwent pelvic ferumoxtran-10 MRA. Eleven anatomical pelvic-vessel segments per patient were evaluated using qualitative and quantitative criteria for image quality (IQ), vessel visibility (VV), and the contrast-to-noise ratio (CNR). INTERVENTION: Ferumoxtran-10-enhaced MRA. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: IQ, VV, and CNR were assessed on a 5-point scale for each data set/vessel segment (very poor, poor, moderate, good, and excellent). RESULTS AND LIMITATIONS: IQ was good to excellent for 98.2% of the data sets and VV was good to excellent for 97.7% of all vessel segments. The mean CNR for all segments was 88.13 (standard deviation 4.22). Contrast bolus imaging cannot be performed with this technique, so it is impossible to visualize the arterial or venous phase separately. The timing of contrast administration is also a limitation, with MRA performed 1 d after contrast infusion. CONCLUSIONS: Ferumoxtran-10 MRA showed excellent image quality and visibility for pelvic vessels. In addition, the homogeneity of the intraluminal contrast was superior. Patients with preterminal or terminal renal function can benefit from ferumoxtran-10 MRA if visualization of their pelvic vessels is required. PATIENT SUMMARY: Magnetic resonance imaging of blood vessels using a contrast agent called ferumoxtran-10 is a promising technique for patients with impaired kidney function, as it provides high-quality visualization of blood vessels in the pelvis.


Assuntos
Meios de Contraste , Angiografia por Ressonância Magnética , Humanos , Recidiva Local de Neoplasia , Artérias
11.
Invest Radiol ; 57(12): 810-818, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35776432

RESUMO

OBJECTIVES: Ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging (MRI) is a potential diagnostic tool for lymph node assessment in patients with head and neck cancer. Validation by radiologic-pathologic correlation is essential before the method is evaluated in clinical studies. In this study, MRI signal intensity patterns of lymph nodes are correlated to their histopathology to develop a new USPIO-enhanced MRI reading algorithm that can be used for nodal assessment in head and neck cancer patients. MATERIALS AND METHODS: Ten head and neck cancer patients underwent in vivo USPIO-enhanced MRI before neck dissection. An ex vivo MRI of the neck dissection specimen was performed for precise coregistration of in vivo MRI with histopathology. Normal clinical histopathological workup was extended with meticulous matching of all lymph nodes regarded as potentially metastatic based on their in vivo MRI signal intensity pattern. On the basis of histopathology of resected nodes, in vivo MRI signal characteristics were defined separating benign from malignant lymph nodes. RESULTS: Fifteen of 34 node-to-node correlated lymph nodes with remaining signal intensity on T2*-weighted MRI were histopathologically metastatic and 19 were benign. Radiological analysis revealed that metastatic lymph nodes showed equal or higher MRI signal intensity when compared with lipid tissue on T2*-weighted MGRE sequence (15/16 lymph nodes; 94%), whereas healthy lymph nodes showed lower (17/19 lymph nodes; 89%) or complete attenuation of signal intensity (273/279; 98%) when compared with lipid tissue on T2*-weighted MGRE. Histopathology of all resected specimens identified 392 lymph nodes. Six lymph nodes with (micro)metastases were missed with in vivo MRI. Whether these 6 lymph nodes were correlated to a nonmalignant lymph node on in vivo MRI or could not be detected at all is unclear. CONCLUSIONS: We developed a new reading algorithm to differentiate benign from malignant lymph nodes in head and neck cancer patients on the basis of their appearance on high-resolution T2*-weighted USPIO-enhanced MRI. Next steps involve validation of our reading algorithm to further improve the accuracy of neck lymph node staging with USPIO-enhanced MRI in prospective clinical studies with larger number of patients.


Assuntos
Neoplasias de Cabeça e Pescoço , Nanopartículas de Magnetita , Humanos , Meios de Contraste , Óxido Ferroso-Férrico , Metástase Linfática/diagnóstico por imagem , Leitura , Estudos Prospectivos , Dextranos , Imageamento por Ressonância Magnética/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Algoritmos , Lipídeos , Estadiamento de Neoplasias
12.
Methods Protoc ; 5(2)2022 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-35314661

RESUMO

BACKGROUND: In various cancer types, the first step towards extended metastatic disease is the presence of lymph node metastases. Imaging methods with sufficient diagnostic accuracy are required to personalize treatment. Lymph node metastases can be detected with ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging (MRI), but this method needs validation. Here, a workflow is presented, which is designed to compare MRI-visible lymph nodes on a node-to-node basis with histopathology. METHODS: In patients with prostate, rectal, periampullary, esophageal, and head-and-neck cancer, in vivo USPIO-enhanced MRI was performed to detect lymph nodes suspicious of harboring metastases. After lymphadenectomy, but before histopathological assessment, a 7 Tesla preclinical ex vivo MRI of the surgical specimen was performed, and in vivo MR images were radiologically matched to ex vivo MR images. Lymph nodes were annotated on the ex vivo MRI for an MR-guided pathological examination of the specimens. RESULTS: Matching lymph nodes of ex vivo MRI to pathology was feasible in all cancer types. The annotated ex vivo MR images enabled a comparison between USPIO-enhanced in vivo MRI and histopathology, which allowed for analyses on a nodal, or at least on a nodal station, basis. CONCLUSIONS: A workflow was developed to validate in vivo USPIO-enhanced MRI with histopathology. Guiding the pathologist towards lymph nodes in the resection specimens during histopathological work-up allowed for the analysis at a nodal basis, or at least nodal station basis, of in vivo suspicious lymph nodes with corresponding histopathology, providing direct information for validation of in vivo USPIO-enhanced, MRI-detected lymph nodes.

13.
Magn Reson Med ; 66(1): 123-34, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21337422

RESUMO

Magnetic resonance-guided percutaneous interventions with needles require fast pulse sequences with acquisition times less than 1 s to image the needle trajectory within moving organs. To guide the movement of a rigid instrument with high sampling rate, an magnetic resonance imaging method was developed that reduces the acquisition time down to a few hundred milliseconds by restricting the field of view to a small stripe around the instrument trajectory. To maintain the dynamic steady state, saturation pulses for outer volume suppression were inserted into additional repetition time-intervals. These saturation intervals were combined with three sequence variants: a spoiled gradient echo sequence, an echo-shifted steady state free precession and a balanced steady state free precession sequence. The magnetization dynamics were analyzed by means of numerical optimized simulations. Results were compared with phantom experiments and an average signal-to-suppression-ratio of 15.5 could be achieved. With a field of view reduction of up to 12.5% an update rate of six images per second could be achieved. Finally, animal experiments demonstrated the fast and reliable needle tip visualization during percutaneous magnetic resonance-guided interventions with the help of a robotic assistance system.


Assuntos
Imageamento por Ressonância Magnética , Administração Cutânea , Animais , Simulação por Computador , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Tamanho do Órgão , Imagens de Fantasmas , Sus scrofa
14.
J Urol ; 186(6): 2214-20, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22014798

RESUMO

PURPOSE: We developed an effective way to precisely diagnose prostate cancer using a novel prostate biopsy system that integrates pre-interventional magnetic resonance imaging with peri-interventional ultrasound for perineal navigated prostate biopsy. MATERIALS AND METHODS: A total of 106 men with findings suspicious for prostate cancer (median age 66 years, prostate specific antigen 8.0 ng/ml and prostate volume 47 ml) underwent multiparametric 3 Tesla magnetic resonance imaging. Suspicious lesions were marked and data were transferred to the novel biopsy system. Using a custom-made biplane transrectal ultrasound probe mounted on a stepper we gathered 3-dimensional ultrasound data and fused them with magnetic resonance imaging data. As a result, suspicious magnetic resonance imaging lesions were superimposed over the transrectal ultrasound data. Three-dimensional biopsy planning was done, including systematic biopsies. Perineal biopsies were taken under live ultrasound guidance and the precise site of each biopsy was documented in 3 dimensions. We evaluated feasibility, safety and cancer detection. RESULTS: Prostate cancer was detected in 63 of 106 patients (59.4%). Magnetic resonance imaging findings correlated positively with histopathology in 71 of 103 patients (68.9%). In magnetic resonance imaging lesions marked as highly suspicious, the detection rate was 95.8% (23 of 24 cases). Lesion targeted cores had a significantly higher positivity rate than nontargeted cores. The procedural targeting error of the first 2,461 biopsy cores was 1.7 mm. Regarding adverse effects, 2 patients experienced urinary retention and 1 had a perineal hematoma. Urinary tract infections did not develop. CONCLUSIONS: Perineal stereotactic prostate biopsies guided by the combination of magnetic resonance imaging and ultrasound enable effective examination of suspicious magnetic resonance imaging lesions. Each biopsy core taken is documented accurately for its location in 3 dimensions, enabling magnetic resonance imaging validation and tailored treatment planning. The morbidity of the procedure was minimal.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia
15.
Invest Radiol ; 56(1): 42-49, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33156126

RESUMO

The presence or absence of lymph node metastases is a very important prognostic factor in patients with solid tumors. Current invasive and noninvasive diagnostic methods for N-staging like lymph node dissection, morphologic computed tomography/magnetic resonance imaging (MRI), or positron emission tomography-computed tomography have significant limitations because of technical, biological, or anatomical reasons. Therefore, there is a great clinical need for more precise, reliable, and noninvasive N-staging in patients with solid tumors. Using ultrasmall superparamagnetic particles of ironoxide (USPIO)-enhanced MRI offers noninvasive diagnostic possibilities for N-staging of different types of cancer, including the 4 examples given in this work (head and neck cancer, esophageal cancer, rectal cancer, and prostate cancer). The excellent soft tissue contrast of MRI and an USPIO-based differentiation of metastatic versus nonmetastatic lymph nodes can enable more precise therapy and, therefore, fewer side effects, essentially in cancer patients in oligometastatic disease stage. By discussing 3 important questions in this article, we explain why lymph node staging is so important, why the timing for more accurate N-staging is right, and how it can be done with MRI. We illustrate this with the newest developments in magnetic resonance methodology enabling the use of USPIO-enhanced MRI at ultrahigh magnetic field strength and in moving parts of the body like upper abdomen or mediastinum. For prostate cancer, a comparison with radionuclide tracers connected to prostate specific membrane antigen is made. Under consideration also is the use of MRI for improvement of ex vivo cancer diagnostics. Further scientific and clinical development is needed to assess the accuracy of USPIO-enhanced MRI of detecting small metastatic deposits for different cancer types in different anatomical locations and to broaden the indications for the use of (USPIO-enhanced) MRI in lymph node imaging in clinical practice.


Assuntos
Linfonodos , Metástase Linfática , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Neoplasias , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
16.
J Nucl Med ; 62(9): 1258-1263, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33517328

RESUMO

Accurate assessment of lymph node (LN) metastases in prostate cancer (PCa) patients is critical for prognosis and patient management. Both prostate-specific membrane antigen (PSMA) PET/CT and ferumoxtran-10 nanoparticle-enhanced MRI (nano-MRI) are imaging modalities with high potential to identify LN metastases in PCa patients. The aim of this study was to compare the results of these imaging technologies in terms of characteristics and anatomic localization of suspicious LNs in order to assess the feasibility of their complementary use for imaging in PCa patients. Methods: In total, 45 patients with either primary PCa (n = 8) or recurrence (n = 36) were included in this retrospective study. All patients underwent both 68Ga-PSMA PET/CT and nano-MRI between October 2015 and July 2017 within 3 wk. Both scans were performed at the same institution according to local clinical protocols. All scans were analyzed independently by experienced nuclear medicine physicians and radiologists. The size, anatomic location, and level of suspicion were determined for all visible LNs. Subsequently, the findings from 68Ga-PSMA PET/CT and nano-MRI were compared without respect to a reference standard. Results: In total, 179 suspicious LNs were identified. Significantly more suspicious LNs per patient were detected by nano-MRI (P < 0.001): 160 were identified in 33 patients by nano-MRI, versus 71 in 25 patients by 68Ga-PSMA PET/CT. Of all suspicious LNs, 108 were identified only by nano-MRI (60%), 19 (11%) only by 68Ga-PSMA PET/CT, and 52 (29%) by both methods. The mean size of the suspicious LNs as identified by nano-MRI was significantly smaller (5.3 mm) than that by 68Ga-PSMA PET/CT (6.0 mm; P = 0.006). The median level of suspicion did not differ significantly. Both modalities identified suspicious LNs in all anatomic regions of the pelvis. Conclusion: Both modalities identified suspicious LNs that were missed by the other. Both modalities identified suspicious LNs in all anatomic regions of the pelvis; however, nano-MRI appeared to be superior in detecting smaller suspicious LNs. These findings suggest that nano-MRI has a potential role as a complement to PSMA PET/CT. However, since the clinical implications of the different results are not well established yet, further investigation of this complementary use is encouraged.


Assuntos
Neoplasias da Próstata , Idoso , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos
17.
Eur J Radiol ; 138: 109636, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33721766

RESUMO

PURPOSE: To evaluate the initial results of predicting lymph node metastasis in rectal cancer patients detected in-vivo with USPIO-enhanced MRI at 3 T compared on a node-to-node basis with histopathology. METHODS: Ten rectal cancer patients of all clinical stages were prospectively included for an in-vivo 0.85 mm3 isotropic 3D MRI after infusion of Ferumoxtran-10. The surgical specimens were examined ex-vivo with an 0.29 mm3 isotropic MRI examination. Two radiologists evaluated in-vivo MR images with a classification scheme to predict lymph node status. Ex-vivo MRI was used for MR-guided pathology and served as a key link between in-vivo MRI and final histopathology for the node-to-node analysis. RESULTS: 138 lymph nodes were detected by reader 1 and 255 by reader 2 (p = 0.005) on in-vivo MRI with a median size of 2.6 and 2.4 mm, respectively. Lymph nodes were classified with substantial inter-reader agreement (κ = 0.73). Node-to-node comparison was possible for 55 lymph nodes (median size 3.2 mm; range 1.2-12.3), of which 6 were metastatic on pathology. Low true-positive rates (3/26, 11 % for both readers) and high true negative rates were achieved (14/17, 82 %; 19/22, 86 %). Pathological re-evaluations of 20 lymph nodes with high signal intensity on USPIO-enhanced MRI without lymph node metastases (false positives) did not reveal tumor metastasis but showed benign lymph node tissue with reactive follicles. CONCLUSIONS: High resolution MRI visualizes a large number of mesorectal lymph nodes. USPIO-enhanced MRI was not accurate for characterizing small benign versus small tumoral lymph nodes in rectal cancer patients. Suspicious nodes on in-vivo MRI occur as inflammatory as well as metastatic nodes.


Assuntos
Nanopartículas de Magnetita , Neoplasias Retais , Meios de Contraste , Dextranos , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia
18.
Prostate Cancer Prostatic Dis ; 24(2): 423-430, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32999466

RESUMO

BACKGROUND: PSMA-PET is a novel imaging modality for the staging of prostate cancer (PCa). While there are several PSMA ligands available, F-18-PSMA-1007 is particularly of interest as it is not renally excreted and therefore does not impair the imaging of the pelvic area. Hence, this study aimed to investigate the F-18-PSMA-1007-PET for the primary staging of PCa and compared it to multi-parametric (mp) MRI and histopathology. METHODS: A retrospective study was performed of men with intermediate and high-risk PCa patients that underwent a F-18-PSMA-1007-PET after mpMRI with subsequent MR-guided target biopsy (MRGB). Suspicious mpMRI lesions and F-18-PSMA-1007-PET were simultaneously reviewed on both a per patient and per-lesion basis. Results were subsequently evaluated with histopathological outcome of MRGB, and if performed, the radical prostatectomy specimen. RESULTS: A total of 66 suspicious mpMRI lesions were identified in 53 patients and underwent MRGB. Two lesions had a maximum standardized uptake value (SUVmax) less than the mean SUVmax of healthy prostate tissue and were considered as non-PSMA-expressing. All PSMA avid tumors had higher SUVmax than the mean SUVmean of the bladder/urine, therefore all lesions were clearly distinguishable in the pelvic area. Twenty-three patients received a radical prostatectomy of which the histopathology specimens were evaluated. F-18-PSMA-1007-PET/CT correctly staged seminal vesicle invasion (i.e. pT3b) more often than mpMRI (90 vs. 76%), whereas mpMRI more accurately detected extracapsular extension (i.e. pT3a) compared to F-18-PSMA-1007-PET (90% vs 57%). CONCLUSIONS: The present study of a selected cohort suggest that dual imaging with mpMRI and F-18-PSMA-1007-PET may improve staging of primary PCa. F-18-PSMA-1007-PET/CT had low renal clearance, which could assist the evaluation of tumors in proximity of the bladder.


Assuntos
Fluordesoxiglucose F18/metabolismo , Niacinamida/análogos & derivados , Oligopeptídeos/metabolismo , Neoplasias da Próstata/patologia , Idoso , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética Multiparamétrica , Niacinamida/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Compostos Radiofarmacêuticos/metabolismo , Estudos Retrospectivos
19.
Pract Radiat Oncol ; 11(3): 202-211, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33941347

RESUMO

PURPOSE: To assess the intermodality and intertracer variability of gallium-68 (68Ga)- or fluorine-18 (18F)-labeled prostate-specific membrane antigen (PSMA) positron emission tomography (PET) and biparametric magnetic resonance imaging (bpMRI)-based gross tumor volume (GTV) delineation for focal boosting in primary prostate cancer. METHODS: Nineteen prospectively enrolled patients with prostate cancer underwent a PSMA PET/MRI scan, divided into a 1:1 ratio between 68Ga-PSMA-11 and 18F-PSMA-1007, before radical prostatectomy (IWT140193). Four delineation teams performed manual contouring of the GTV based on bpMRI and PSMA PET imaging, separately. Index lesion coverage (overlap%) and interobserver variability were assessed. Furthermore, the distribution of the voxelwise normalized standardized uptake values (SUV%) was determined for the majority-voted (>50%) GTV (GTVmajority) and whole prostate gland to investigate intertracer variability. The median patientwise SUV% contrast ratio (SUV%-CR, calculated as median GTVmajority SUV% / median prostate gland without GTVmajority SUV%) was calculated according to the tracer used. RESULTS: A significant difference in overlap% favoring PSMA PET compared with bpMRI was found in the 18F subgroup (median, 63.0% vs 53.1%; P = .004) but was not present in the 68Ga subgroup (32.5% vs 50.6%; P = .100). Regarding interobserver variability, measured Sørensen-Dice coefficients (0.58 vs 0.72) and calculated mean distances to agreement (2.44 mm vs 1.22 mm) were statistically significantly lower and higher, respectively, for the 18F cohort compared with the 68Ga cohort. For the bpMRI-based delineations, the median Sørensen-Dice coefficient and mean distance to agreement were 0.63 and 1.76 mm, respectively. Median patientwise SUV%-CRs of 1.8 (interquartile range [IQR], 1.6-2.7) for 18F-PSMA and 3.3 (IQR, 2.7-5.9) for 68Ga-PSMA PET images were found. CONCLUSIONS: Both MRI and PSMA PET provided consistent intraprostatic GTV lesion detection. However, the PSMA tracer seems to have a major influence on the contour characteristics, owing to an apparent difference in SUV% distribution in the prostate gland.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Imageamento por Ressonância Magnética , Masculino , Niacinamida/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Carga Tumoral
20.
Trials ; 22(1): 768, 2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34736509

RESUMO

BACKGROUND: The BULLSEYE trial is a multicenter, open-label, randomized controlled trial to test the hypothesis if 177Lu-PSMA is an effective treatment in oligometastatic hormone-sensitive prostate cancer (oHSPC) to prolong the progression-free survival (PFS) and postpone the need for androgen deprivation therapy (ADT). The original study protocol was published in 2020. Here, we report amendments that have been made to the study protocol since the commencement of the trial. CHANGES IN METHODS AND MATERIALS: Two important changes were made to the original protocol: (1) the study will now use 177Lu-PSMA-617 instead of 177Lu-PSMA-I&T and (2) responding patients with residual disease on 18F-PSMA PET after the first two cycles are eligible to receive additional two cycles of 7.4 GBq 177Lu-PSMA in weeks 12 and 18, summing up to a maximum of 4 cycles if indicated. Therefore, patients receiving 177Lu-PSMA-617 will also receive an interim 18F-PSMA PET scan in week 4 after cycle 2. The title of this study was modified to; "Lutetium-177-PSMA in Oligo-metastatic Hormone Sensitive Prostate Cancer" and is now partly supported by Advanced Accelerator Applications, a Novartis Company. CONCLUSIONS: We present an update of the original study protocol prior to the completion of the study. Treatment arm patients that were included and received 177Lu-PSMA-I&T under the previous protocol will be replaced. TRIAL REGISTRATION: ClinicalTrials.gov NCT04443062 . First posted: June 23, 2020.


Assuntos
Antagonistas de Androgênios , Neoplasias de Próstata Resistentes à Castração , Hormônios , Humanos , Lutécio/efeitos adversos , Masculino , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Radioisótopos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA