Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Trop Med Hyg ; 111(3): 617-621, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-38981496

RESUMO

Bangladesh experienced the largest and deadliest dengue outbreak in 2023, after the virus had reappeared in the country 2 decades earlier. A total of 1,705 people died in Bangladesh, representing the highest case fatality rate (0.5%) due to dengue in the world for that year. The severity of dengue infection is to some extent related to the emergence of new circulating serotypes. To identify the possible predominant serotype in 2023, the reverse transcription polymerase chain reaction-based identification technique was used on stored serum samples of suspected dengue patients during the period between July and December 2023. The overall result of molecular serotyping showed that dengue virus (DENV-2) reappeared as the predominant serotype (74.1%), followed by a moderate number of samples with DENV-1 (19.8%) and DENV-3 (6.1%), in 2023. However, DENV-1 was found to be dominant in a few rural areas of Cox's Bazar districts. During the 2019 outbreak, DENV-3 was the dominant serotype, which seemed to be replaced by the DENV-2 serotype; this may have impacted the increased case fatality in 2023.


Assuntos
Vírus da Dengue , Dengue , Surtos de Doenças , Sorogrupo , Bangladesh/epidemiologia , Vírus da Dengue/genética , Vírus da Dengue/classificação , Vírus da Dengue/isolamento & purificação , Humanos , Dengue/epidemiologia , Dengue/virologia , Masculino , Feminino , Adolescente , Sorotipagem , Adulto , Adulto Jovem , Criança , Pré-Escolar , Pessoa de Meia-Idade
2.
Pathogens ; 11(11)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36422640

RESUMO

Amongst the multiple ways to diagnose coronavirus disease-2019 (COVID-19), reverse transcription polymerase chain reaction (RT-PCR) remains the reference gold standard, providing fast and accurate results. This study evaluated and compared the performance of three commercially available COVID-19 RT-PCR kits-Aridia® COVID-19 Real-Time PCR Test (CTK Biotech, Inc., Poway, CA, USA), Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Sansure Biotech Inc., Changsha, China) and AllplexTM 2019-nCoV assay (Seegene Inc., Seoul, Republic of Korea) for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A total of 326 clinically suspected patients were enrolled for the study, and among them, 209 were diagnosed as positive and 117 as negative when tested with the reference method, US CDC 2019-Novel Coronavirus (2019-nCoV) Real Time RT-PCR Diagnostic Panel. The Aridia® kit showed total agreement with the reference test, with a sensitivity of 100% (95% CI: 98.25% to 100.0%) and a specificity of 100% (96.90% to 100.00%). The AllplexTM kit also showed 100% specificity (95% CI: 96.90% to 100.00%), but a lower sensitivity (98.09%, 95% CI: 95.17% to 99.48%). Among the three kits, the Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit showed the worst performance, with a sensitivity of 98.6% (95% CI: 95.9% to 99.7%) and a specificity of 95.73, 95% (CI: 90.31% to 98.60%). While all these kits conform to the requirement for routine molecular diagnosis with high performances, the Aridia® COVID-19 Real-Time PCR Test showed the best performance among the three kits.

3.
J Infect Dev Ctries ; 16(11): 1768-1772, 2022 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-36449650

RESUMO

INTRODUCTION: Malaria is a significant global health concern and adversely affects people in developing countries including Bangladesh. The causative agent Plasmodium falciparum is resistant to several currently available anti-malarial drugs, such as mefloquine, chloroquine, and artemisinin-based combination therapy (ACT), and this has been a major global challenge towards the control of the disease. There is urgent need for novel anti-malarial chemotherapeutic agents. METHODOLOGY: The present study aimed to evaluate antimalarial activity of methanolic extracts of three Bangladeshi medicinal plants- Acorus calamus, Dichapetalum gelonioides and Leucas aspera - against both chloroquine sensitive (3D7) and resistant (Dd2) strains of P. falciparum. Histidine-rich protein 2 (HRP2) based ELISA was used to evaluate the in vitro inhibitory activity of the extracts. RESULTS: D. gelonioides extract showed moderate (IC50 = 19.15 µg/mL) and promising activity (IC50 = 10.43 µg/mL) against 3D7 and Dd2 strains respectively. A. calamus remained inactive against both 3D7 (IC50 = 72.29 µg/mL) and Dd2 strain (IC50 = 67.81 µg/mL). L. aspera initially remained inactive against 3D7 strain (IC50 = 60.51 µg/mL), but displayed promising activity (IC50 = 7.693) against Dd2 strain. CONCLUSIONS: This is the first time these plant materials have been assessed for their in vitro antimalarial properties. It is pivotal to conduct further phytochemical analysis of D. gelonioides and L. aspera to evaluate the presence of potential novel antimalarial drug compounds.


Assuntos
Acorus , Antimaláricos , Malária Falciparum , Humanos , Antimaláricos/farmacologia , Plasmodium falciparum , Cloroquina , Malária Falciparum/tratamento farmacológico
4.
Microbiol Spectr ; 10(6): e0199822, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36453913

RESUMO

Accurate and early diagnoses are prerequisites for prompt treatment. For coronavirus disease 2019 (COVID-19), it is even more crucial. Currently, choice of methods include rapid diagnostic tests and reverse transcription polymerase chain reaction (RT-PCR) using samples mostly of respiratory origin and sometimes saliva. We evaluated two rapid diagnostic tests with three specimen types using viral transport medium (VTM) containing naso-oropharyngeal (NOP) swabs, direct nasal and direct nasopharyngeal (NP) samples from 428 prospective patients. We also performed RT-PCR for 428 NOP VTM and 316 saliva samples to compare results. The sensitivity of the SD Biosensor Standard Q COVID-19 antigen (Ag) test kit drastically raised from an average of 65.55% (NOP VTM) to 85.25% (direct nasal samples), while RT-PCR was the gold standard. For the CareStart kit, the sensitivity was almost similar for direct NP swabs; the average was 84.57%. The specificities were ≥95% for both SD Biosensor Standard Q and CareStart COVID-19 Ag tests in all platforms. The kits were also able to detect patients with different variants as well. Alternatively, RT-PCR results from saliva and NOP VTM samples showed high sensitivities of 96.45% and 95.48% with respect to each other as standard. The overall results demonstrated high performance of the rapid tests, indicating the suitability for regular surveillance at clinical facilities when using direct nasal or direct NP samples rather than NOP VTM. Additionally, the analysis also signifies not showed that RT-PCR of saliva can be used as an choice of method to RT-PCR of NOP VTM, providing an easier, non-invasive sample collection method. IMPORTANCE There are several methods for the diagnosis of coronavirus disease 2019 (COVID-19), and the choice of methods depends mostly on the resources and level of sensitivity required by the user and health care providers. Still, reverse transcription polymerase chain reaction (RT-PCR) has been chosen as the best method using direct naso-oropharyngeal swabs. There are also other methods of fast detection, such as rapid diagnostic tests (RDTs), which offer result within 15 to 20 min and have become quite popular for self-testing and in the clinical setting. The major drawback of the currently used RT-PCR method is compliance, as it may cause irritation, and patients often refuse to test in such a way. RDTs, although inexpensive, suffer from low sensitivity due to technical issues. In this article, we propose saliva as a noninvasive source for RT-PCR samples and evaluate various specimen types at different times after infection for the best possible output from COVID-19 rapid tests.


Assuntos
Teste para COVID-19 , COVID-19 , Humanos , Estudos Prospectivos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Saliva , COVID-19/diagnóstico , Manejo de Espécimes
5.
Diagnostics (Basel) ; 11(12)2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34943537

RESUMO

Accurate diagnosis at the right moment is the prerequisite for treatment of any disease. Failure to correctly diagnose a disease can result in highly detrimental effects, unmistakably a crucial factor during the COVID-19 pandemic. RT-PCR is the gold standard for COVID-19 detection while there are other test procedures available, such as LAMP, X-Ray, and ELISA. However, these tests are expensive, require sophisticated equipment and a highly trained workforce, and multiple hours or even days are often required to obtain the test results. A rapid and cheap detection system can thus render a solution to the screening system on a larger scale and be added as an aid to the current detection processes. Recently, some rapid antigen-based COVID-19 tests devices have been developed and commercialized. In this study, we evaluated the clinical performance of a new rapid detection device (OnSite® COVID-19 Ag Rapid Test by CTK Biotech Inc., Poway, CA, USA) on COVID-19 symptomatic patients (n = 380). The overall sensitivity and specificity were 91.0% (95% CI: 84.8-95.3%) and 99.2% (95% CI: 97.1-99.9), against gold standard RT-PCR. The kit was capable of detecting patients even after 06 days of onset of symptoms and the sensitivity can be maximized to 98% in samples with an average RT-PCR Ct ≤ 26.48, demonstrating a high potential of the kit for clinical diagnosis of symptomatic patients in healthcare facilities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA