Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Monit Comput ; 36(2): 419-427, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33559864

RESUMO

BACKGROUND: Driving pressure can be readily measured during assisted modes of ventilation such as pressure support ventilation (PSV) and neurally adjusted ventilatory assist (NAVA). The present prospective randomized crossover study aimed to assess the changes in driving pressure in response to variations in the level of assistance delivered by PSV vs NAVA. METHODS: 16 intubated adult patients, recovering from hypoxemic acute respiratory failure (ARF) and undergoing assisted ventilation, were randomly subjected to six 30-min-lasting trials. At baseline, PSV (PSV100) was set with the same regulation present at patient enrollment. The corresponding level of NAVA (NAVA100) was set to match the same inspiratory peak of airway pressure obtained in PSV100. Therefore, the level of assistance was reduced and increased by 50% in both ventilatory modes (PSV50, NAVA50; PSV150, NAVA150). At the end of each trial, driving pressure obtained in response to four short (2-3 s) end-expiratory and end-inspiratory occlusions was analyzed. RESULTS: Driving pressure at PSV50 (6.6 [6.1-7.8] cmH2O) was lower than that recorded at PSV100 (7.9 [7.2-9.1] cmH2O, P = 0.005) and PSV150 (9.9 [9.1-13.2] cmH2O, P < 0.0001). In NAVA, driving pressure at NAVA50 was reduced compared to NAVA150 (7.7 [5.1-8.1] cmH2O vs 8.3 [6.4-11.4] cmH2O, P = 0.013), whereas there were no changes between baseline and NAVA150 (8.5 [6.3-9.8] cmH2O vs 8.3 [6.4-11.4] cmH2O, P = 0.331, respectively). Driving pressure at PSV150 was higher than that observed in NAVA150 (P = 0.011). CONCLUSIONS: NAVA delivers better lung-protective ventilation compared to PSV in hypoxemic ARF patients. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION: The present trial was prospectively registered at www.clinicatrials.gov (NCT03719365) on 24 October 2018.


Assuntos
Suporte Ventilatório Interativo , Insuficiência Respiratória , Adulto , Estudos Cross-Over , Humanos , Pulmão , Estudos Prospectivos , Respiração , Insuficiência Respiratória/terapia
2.
J Clin Monit Comput ; 34(6): 1223-1231, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31792760

RESUMO

Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated Pes (Pescal) was compared to uncalibrated one acquired at 4 ml-filling volume (PesV4), as per manufacturer recommendation. After a naso-gastric tube equipped with oesophageal balloon was correctly positioned in 21 adult patients undergoing invasive volume-controlled ventilation (VCV) for acute hypoxemic respiratory failure, the balloon was progressively inflated, applying a series of end-inspiratory and end-expiratory holds at each filling volume during VCV and PSV. Upon optimal balloon filling volume (Vbest) was identified, Pescal was computed by correcting the Pes measured at Vbest for the oesophageal wall pressure elicited at same filling volume. Finally, end-expiratory and end-inspiratory PesV4 were recorded too. A total of 42 calibrations, 21 per ventilatory mode, were performed. Vbest was 1.9 ± 1.6 ml in VCV and 1.7 ± 1.6 ml in PSV (p = 0.5217). PesV4 was overestimated compared to Pescal at end-expiration and end-inspiration (p <0.0001 for all comparisons) in both VCV (13.4 ± 3.4 cmH2O and 15.4 ± 3 cmH2O vs. 8.5 ± 2.9 cmH2O and 11.4 ± 3 cmH2O) and PSV (14.7 ± 4.2 cmH2O and 17 ± 3.9 cmH2O vs. 8.9 ± 3.4 cmH2O and 12.4 ± 3.9 cmH2O). In PSV, oesophageal balloon calibration is feasible and allows to obtain a reliable Pes assessment compared to uncalibrated approach.


Assuntos
Respiração com Pressão Positiva , Mecânica Respiratória , Adulto , Calibragem , Humanos , Estudo de Prova de Conceito , Respiração Artificial
3.
Respir Care ; 66(6): 983-993, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33906957

RESUMO

BACKGROUND: The assessment of diaphragmatic kinetics through tissue Doppler imaging (dTDI) was recently proposed as a means to describe diaphragmatic activity in both healthy individuals and intubated patients undergoing weaning from mechanical ventilation. Our primary aim was to investigate whether the diaphragmatic excursion velocity measured with dTDI at the end of a spontaneous breathing trial (SBT) was different in subjects successfully extubated versus those who passed the trial but exhibited extubation failure within 48 h after extubation. METHODS: We enrolled 100 adult subjects, all of whom had successfully passed a 30-min SBT conducted in CPAP of 5 cm H2O. In cases of extubation failure within 48 h after liberation from invasive mechanical ventilation, subjects were re-intubated or supported through noninvasive ventilation. dTDI was performed at the end of the SBT to assess excursion, velocity, and acceleration. RESULTS: Extubation was successful in 79 subjects, whereas it failed in 21 subjects. The median (interquartile range [IQR]) inspiratory peak excursion velocity (3.1 [IQR 2.0-4.3] vs 1.8 [1.3-2.6] cm/s, P < .001), mean velocity (1.6 [IQR 1.2-2.4] vs 1.1 [IQR 0.8-1.4] cm/s, P < .001), and acceleration (8.8 [IQR 5.0-17.8] vs 4.2 [IQR 2.4-8.0] cm/s2, P = .002) were all significantly higher in subjects who failed extubation compared with those who were successfully extubated. Similarly, the median expiratory peak relaxation velocity (2.6 [IQR 1.9-4.5] vs 1.8 [IQR 1.2-2.5] cm/s, P < .001), mean velocity (1.1 [IQR 0.7-1.7] vs 0.9 [IQR 0.6-1.0] cm/s, P = .002), and acceleration (11.2 [IQR 9.1-19.0] vs 7.1 [IQR 4.6-12.0] cm/s2, P = .004) were also higher in the subjects who failed extubation. CONCLUSIONS: In our setting, at the end of SBT, subjects who developed extubation failure within 48 h after extubation experienced a greater diaphragmatic activation compared with subjects who were successfully extubated. (ClinicalTrials.gov registration NCT03962322.).


Assuntos
Extubação , Desmame do Respirador , Adulto , Diafragma/diagnóstico por imagem , Humanos , Cinética , Respiração Artificial
4.
J Crit Care ; 61: 125-132, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33157308

RESUMO

PURPOSE: Optimal esophageal balloon filling volume (Vbest) depends on the intrathoracic pressure. During Sigh breath delivered by the ventilator machine, esophageal balloon is surrounded by elevated intrathoracic pressure that might require higher filling volume for accurate measure of tidal changes in esophageal pressure (Pes). The primary aim of our investigation was to evaluate and compare Vbest during volume controlled and pressure support breaths vs. Sigh breath. MATERIALS AND METHODS: Twenty adult patients requiring invasive volume-controlled ventilation (VCV) for hypoxemic acute respiratory failure were enrolled. After the insertion of a naso-gastric catheter equipped with 10 ml esophageal balloon, each patient underwent three 30-min trials as follows: VCV, pressure support ventilation (PSV), and PSV + Sigh. Sigh was added to PSV as 35 cmH2O pressure-controlled breath over 4 s, once per minute. PSV and PSV + Sigh were randomly applied and, at the end of each step, esophageal balloon calibration was performed. RESULTS: Vbest was higher for Sigh breath (4.5 [3.0-6.8] ml) compared to VCV (1.5 [1.0-2.9] ml, P = 0.0004) and PSV tidal breath (1.0 [0.5-2.4] ml, P < 0.0001). CONCLUSIONS: During Sigh breath, applying a calibrated approach for Pes assessment, a higher Vbest was required compared to VCV and PSV tidal breath.


Assuntos
Respiração com Pressão Positiva , Mecânica Respiratória , Adulto , Calibragem , Estudos Cross-Over , Humanos , Respiração Artificial , Volume de Ventilação Pulmonar
5.
Sci Rep ; 11(1): 13418, 2021 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-34183764

RESUMO

In patients intubated for hypoxemic acute respiratory failure (ARF) related to novel coronavirus disease (COVID-19), we retrospectively compared two weaning strategies, early extubation with immediate non-invasive ventilation (NIV) versus standard weaning encompassing spontaneous breathing trial (SBT), with respect to IMV duration (primary endpoint), extubation failures and reintubations, rate of tracheostomy, intensive care unit (ICU) length of stay and mortality (additional endpoints). All COVID-19 adult patients, intubated for hypoxemic ARF and subsequently extubated, were enrolled. Patients were included in two groups, early extubation followed by immediate NIV application, and conventionally weaning after passing SBT. 121 patients were enrolled and analyzed, 66 early extubated and 55 conventionally weaned after passing an SBT. IMV duration was 9 [6-11] days in early extubated patients versus 11 [6-15] days in standard weaning group (p = 0.034). Extubation failures [12 (18.2%) vs. 25 (45.5%), p = 0.002] and reintubations [12 (18.2%) vs. 22 (40.0%) p = 0.009] were fewer in early extubation compared to the standard weaning groups, respectively. Rate of tracheostomy, ICU mortality, and ICU length of stay were no different between groups. Compared to standard weaning, early extubation followed by immediate NIV shortened IMV duration and reduced the rate of extubation failure and reintubation.


Assuntos
COVID-19/patologia , Ventilação não Invasiva/métodos , Desmame do Respirador/métodos , Idoso , COVID-19/mortalidade , COVID-19/virologia , Comorbidade , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação , Fatores de Tempo , Traqueostomia
6.
Respir Care ; 65(5): 625-635, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32345760

RESUMO

BACKGROUND: Pneumoperitoneum and Trendelenburg position affect respiratory system mechanics and oxygenation during elective pelvic robotic surgery. The primary aim of this randomized pilot study was to compare the effects of a conventional low tidal volume ventilation with PEEP guided by gas exchange (VGas-guided) versus low tidal volume ventilation tailoring PEEP according to esophageal pressure (VPes-guided) on oxygenation and respiratory mechanics during elective pelvic robotic surgery. METHODS: This study was conducted in a single-center tertiary hospital between September 2017 and January 2019. Forty-nine adult patients scheduled for elective pelvic robotic surgery were screened; 28 subjects completed the full analysis. Exclusion criteria were American Society of Anesthesiologists physical status ≥ 3, contraindications to nasogastric catheter placement, and pregnancy. After dedicated naso/orogastric catheter insertion, subjects were randomly assigned to VGas-guided ([Formula: see text] and PEEP set to achieve [Formula: see text] > 94%) or VPes-guided (PEEP tailored to equalize end-expiratory transpulmonary pressure). Oxygenation ([Formula: see text]/[Formula: see text]) was evaluated (1) at randomization, after pneumoperitoneum and Trendelenburg application; (2) at 60 min; (3) at 120 min following randomization; and (4) at end of surgery. Respiratory mechanics were assessed during the duration of the study. RESULTS: Compared to VGas-guided, oxygenation was higher with VPes-guided at 60 min (388 ± 90 vs 308 ± 95 mm Hg, P = .02), at 120 min after randomization (400 ± 90 vs 308 ± 81 mm Hg, P = .008), and at the end of surgery (402 ± 95 vs 312 ± 95 mm Hg, P = .009). Respiratory system elastance was lower with VPes-guided compared to VGas-guided at 20 min (24.2 ± 7.3 vs 33.4 ± 10.7 cm H2O/L, P = .001) and 60 min (24.1 ± 5.4 vs 31.9 ± 8.5 cm H2O/L, P = .006) from randomization. CONCLUSIONS: Oxygenation and respiratory system mechanics were improved when applying a ventilatory strategy tailoring PEEP to equalize expiratory transpulmonary pressure in subjects undergoing pelvic robotic surgery compared to a VGas-guided approach. (ClinicalTrials.gov registration NCT03153592).


Assuntos
Respiração com Pressão Positiva/métodos , Mecânica Respiratória , Idoso , Esôfago/fisiologia , Feminino , Decúbito Inclinado com Rebaixamento da Cabeça , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Pelve/cirurgia , Projetos Piloto , Pneumoperitônio , Estudos Prospectivos , Respiração , Procedimentos Cirúrgicos Robóticos , Volume de Ventilação Pulmonar
7.
Respir Care ; 64(12): 1469-1477, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31455684

RESUMO

BACKGROUND: Early identification of noninvasive ventilation (NIV) outcome predictors in patients with COPD who are experiencing acute hypercapnic respiratory failure consequent to exacerbation or pneumonia is a critical issue. The primary aim of this study was to investigate the feasibility of performing diaphragmatic ultrasound for excursion, thickness, and thickening fraction in highly dyspneic subjects with COPD admitted to the emergency department for exacerbation or pneumonia, before starting NIV (T0) and after the first (T1) and second hour (T2) of treatment. Secondarily, we determined whether these variables predicted early NIV failure. METHODS: Adult subjects with COPD admitted to the emergency department for exacerbation or pneumonia requiring NIV were eligible. Right-sided diaphragmatic excursion, bilateral thickness, thickening fraction, and arterial blood gas analyses were performed at T0, T1, and T2. Feasibility was estimated by considering the number of subjects whose diaphragmatic function could be evaluated at each time point. At T2, subjects were classified in 2 subgroups according to early NIV failure, which was defined as the inability to achieve a pH ≥ 7.35; the ability to achieve pH ≥ 7.35 indicated NIV success. RESULTS: Of the 22 subjects enrolled, 21 underwent complete diaphragm ultrasound evaluation (ie, right excursion and bilateral thickness at T0, T1, and T2) for a total of 63 excursion and 126 thickness assessments. At T2, 12 NIV successes and 9 NIV failures were recorded. Diaphragmatic excursion was greater in NIV successes than in NIV failures at T0 (1.92 [1.22-2.54] cm versus 1.00 [0.60-1.41] cm, P = .02), at T1 (2.14 [1.76-2.77] cm versus 0.93 [0.82-1.27] cm, P = .007), and at T2 (1.99 [1.63-2.54] cm versus 1.20 [0.79-1.41] cm, P = .008), respectively. Diaphragmatic thickness and thickening fraction were similar in both groups. CONCLUSIONS: In our emergency department setting, diaphragm ultrasound was a feasible and reliable tool to monitor highly dyspneic acute hypercapnic respiratory failure subjects with COPD undergoing NIV. (ClinicalTrials.gov registration NCT03314883.).


Assuntos
Hipercapnia/diagnóstico por imagem , Ventilação não Invasiva , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Insuficiência Respiratória/diagnóstico por imagem , Ultrassonografia/métodos , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Diafragma/diagnóstico por imagem , Diafragma/fisiopatologia , Serviço Hospitalar de Emergência , Estudos de Viabilidade , Feminino , Humanos , Masculino , Doença Pulmonar Obstrutiva Crônica/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA