Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Electrophoresis ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38041407

RESUMO

Precisely and accurately determining the magnetic force and its spatial distribution in microfluidic devices is challenging. Typically, magnetic microfluidic devices are designed in a way to both maximize the force within the separation region and to minimize the necessity for knowing such details-such as designing magnetic geometries that create regions of nearly constant magnetic force or that dictate the behavior of the magnetic force to be highly predictable in a specified region. In this work, we present a method to determine the spatial distribution of the magnetic force field in a magnetic microfluidic device by particle tracking magnetophoresis. Polystyrene microparticles were suspended in a paramagnetic fluid, gadolinium, and this suspension was exposed to various magnetic field geometries. Polystyrene particle motion was tracked using a microscope and images processed using Fiji (ImageJ). From a sample with a large spatial distribution of particle tracks, the magnetic force field distribution was calculated. The force field distribution was fitted to nonlinear spatial distribution models. These experimental models are compared to and supported by 3D simulations of the magnetic force field in COMSOL.

2.
Sep Purif Technol ; 2802022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35035269

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) are currently popular materials experiencing rapid development with potential application value, especially in biomedical and chemical engineering fields. Examples include wastewater management, bio-detection, biological imaging, targeted drug delivery and biosensing. While not exclusive, magnetically driven isolation methods are typically required to separate the desired entity from the media in specific applications and in their manufacture and/or quality control. However, due to the nano-size of SPIONs, their magnetic manipulation is affected by Brownian motion, adding considerable complexities. The two most common methods for SPION magnetic separation are high and low gradient magnetic separation (HGMS and LGMS, respectively). Nevertheless, the effect of specific magnetic energy fields on SPIONs, such as horizontal (perpendicular to gravity), high fields and gradients (higher than LGMS) on the horizontal magnetophoresis and vertical sedimentation of SPIONs has only recently been suggested as a way to separate very small particles (5 nm). In this work, we continue those studies on the magnetic separation of 5-30 nm SPIONs by applying fields and gradients perpendicular to gravity. The magnetic field was generated by permanent magnets arranged in quadrupolar configurations (QMS). Different conditions were studied, and multiple variables were evaluated, including the particle size, the initial SPIONs concentration, the temperature, the magnetic field gradient and the magnetic exposure time. Our experimental data show that particles are subjected to horizontal magnetic forces, to particle agglomeration due to dipole-dipole interactions, and to vertical sedimentation due to gravity. The particle size and the type of separator employed (i.e. different gradient and field distribution acting on the particle suspension) have significant effects on the phenomena involved in the separation, whereas the temperature and particle concentration affect the separation to a lesser extent. Finally, the separation process was observed to occur in less than 3 mins for our experimental conditions, which is encouraging considering the long operation time (up to days) necessary to separate particles of similar sizes in LGMS columns that also employ permanent magnets.

3.
Anal Chem ; 92(2): 1956-1962, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31874030

RESUMO

The current clinical method for detecting anemia focuses on measuring the concentration of hemoglobin (Hb) in blood. However, recent developments in particle tracking algorithms and the understanding of the relationship between Hb and magnetism has enabled the quantitative measurement of the Hb content in a single red blood cell, RBC, based on magnetophoretic mobility. To further explore this relationship, 22 human blood samples obtained from 17 healthy volunteers were analyzed by the cell tracking velocimetry system, and the calculated Hb concentration from these measurements was compared to the values measured by UV-visible spectrophotometry, the standard method for measuring Hb in clinical laboratories. The results show close correlations between the mean of the spectrophotometric and magnetophoretic methods; however, single cell analysis with the magnetophoretic mobility method allows further elucidation of the distribution of Hb concentration within RBCs from a donor sample to be determined. Histograms of these magnetophoretic mobility distributions indicate that the fraction of RBCs that are below the bulk Hb concentration that defines anemia varies not only from donor to donor but also in the same donor over time. Consistent with a variable fraction below the anemic Hb concentration, the distribution around the mean has a large range. Previous studies have indicated that RBCs lose Hb during ex vivo storage; however, it is not known if this variability in the distribution of Hb content is a function of the age of the RBCs in a donor, suggesting a variable rate in RBC production between donors, or variability in available iron at the time of RBC formation. We suggest our cell tracking velocimetry system can reveal more information regarding this matter.


Assuntos
Rastreamento de Células/métodos , Hemoglobinas/análise , Reologia/métodos , Adulto , Anemia/diagnóstico , Eritrócitos/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
Sep Purif Technol ; 2482020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32655283

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) are employed in multiple applications, especially within medical and chemical engineering fields. However, their magnetic separation is very challenging as the magnetophoretic motion is hindered by thermal energy and viscous drag. Recent studies have addressed the recovery of SPIONs by a combination of cooperative magnetophoresis and sedimentation. Nevertheless, the effect of horizontal, high fields and gradients on the vertical sedimentation of SPIONs has not been described. In this work, we report, for the first time, the magnetically facilitated sedimentation of 5 nm particles by applying fields and gradients perpendicular to gravity. The magnetic field was generated by quadrupole magnetic sorters and the process was measured with time by tracking the concentration along the length of a channel contacting the 5 nm SPIONs within the quadrupole field. Our experimental data suggest that aggregates of 60-90 particles are formed in the system; thus, particle agglomeration by dipole-dipole interactions was promoted, and these clusters settled down as a result of gravitational forces. Multiple variables and parameters were evaluated, including the initial SPION concentration, the temperature, the magnetic field and gradient and operation time. It was found that the process was improved by decreasing the initial concentration and the temperature, but the magnitude of the magnetic field and gradient did not significantly affect the sedimentation. Finally, the separation process was rapid, with the systems reaching the equilibrium in approximately 20 minutes, which is a significant advantage in comparison to other systems that require longer times and larger particle sizes.

5.
Cytometry A ; 95(5): 478-487, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30958642

RESUMO

The presence of iron in circulating monocytes is well known as they play essential roles in iron recycling. Also, the storage of this metal as well as its incorrect uptake and/or release are important data to diagnose different pathologies. It has been demonstrated that iron storage in human blood cells can be measured through their magnetic behavior with high accuracy; however, the magnetic characteristics of monocytes have not been reported so far to the best of our knowledge. Therefore, in this work, we report, for the first time, the physical and magnetic properties of human monocytes, along with plasma platelets, oxyhemoglobin red blood cells (oxyHb-RBCs), and methemoglobin red blood cells (metHb-RBCs). The different cell populations were separated by Ficoll-density gradient centrifugation, followed by a flow sorting step to isolate monocytes from peripheral blood mononuclear cells. The different fractions were analyzed by Coulter Counter (for determining the size distribution and concentration) and the sorted monocytes were qualitatively analyzed on ImageStream, a state-of-the-art imaging cytometer. The analysis of the Coulter Counter and ImageStream data suggests that although there exists contamination in the monocyte fraction, the integrity of the sorted monocytes appears to be intact and the concentration was high enough to precisely measure their magnetic velocity by Cell Tracking Velocimetry. Surprisingly, monocytes reported the highest magnetic mobility from the four fractions under analysis, with an average magnetic velocity 7.8 times higher than MetHb-RBCs, which is the only type of cells with positive magnetic velocities. This value is equivalent to a susceptibility 2.5 times higher than the value reported by fresh MetHb-RBCs. It should be noted that this is the first study that reports that a subpopulation of human monocytes is much more magnetic than MetHb-RBCs, opening the door to the possible isolation of human monocytes by label-free magnetic techniques. Further, it is suggested that these magnetic monocytes could "contaminate" positively selected, immunomagnetically labeled blood cells (i.e., during a process using magnetically conjugated antibodies targeting cells, such as CD34 positive cells). Conversely, these magnetic monocytes could be inadvertently removed from a desired blood population when one is using a negative magnetic isolation technique to target cells for removal. © 2019 International Society for Advancement of Cytometry.


Assuntos
Sangue/metabolismo , Fenômenos Magnéticos , Monócitos/citologia , Separação Celular , Tamanho Celular , Rastreamento de Células , Centrifugação com Gradiente de Concentração , Citometria de Fluxo , Humanos , Processamento de Imagem Assistida por Computador
6.
Biotechnol Bioeng ; 116(7): 1644-1655, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30906984

RESUMO

This study focuses on different iron regulation mechanisms of glioblastoma (GBM) cancer stem-like cells (CSCs) and non-stem tumor cells (NSTCs) using multiple approaches: cell viability, density, and magnetophoresis. GBM CSCs and NSTCs were exposed to elevated iron concentration, and their magnetic susceptibility was measured using single cell magnetophoresis (SCM), which tracks the magnetic and settling velocities of thousands of individual cells passing through the magnetic field with a constant energy gradient. Our results consistently demonstrate that GBM NSTCs have higher magnetic susceptibility distribution at increased iron concentration compared with CSCs, and we speculate that it is because CSCs have the ability to store a high amount of iron in ferritin, whereas the free iron ions inside the NSTCs lead to higher magnetic susceptibility and reduced cell viability and growth. Further, their difference in magnetic susceptibility has led us to pursue a separate experiment using a quadrupole magnetic separator (QMS), a novel microfluidic device that uses a concentric channel and permanent magnets in a special configuration to separate samples based on their magnetic susceptibilities. GBM CSCs and NSTCs were exposed to elevated iron concentration, stained with two different trackers, mixed and introduced into QMS; subsequently, the separated fractions were analyzed by fluorescent microscopy. The separation results portray a successful label-less magnetic separation of the two populations.


Assuntos
Neoplasias Encefálicas/metabolismo , Glioblastoma/metabolismo , Ferro/metabolismo , Campos Magnéticos , Técnicas Analíticas Microfluídicas , Células-Tronco Neoplásicas/metabolismo , Animais , Neoplasias Encefálicas/patologia , Glioblastoma/patologia , Humanos , Camundongos , Células-Tronco Neoplásicas/patologia
7.
Analyst ; 144(3): 935-942, 2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30617361

RESUMO

This study initially focused on characterizing the aging process of red blood cells by correlating the loss of hemoglobin and the translocation of phosphatidylserine (PS) in expired human red blood cells, hRBCs. Five pre-storage, leukoreduced hRBC units in AS-5 solution were stored between 1 and 6 °C for 42 days. Aliquots from each of these units were stained with Annexin-V FLUOS, which binds to externalized PS, and the hemoglobin within the cells was placed in a methemoglobin state with sodium nitrite, metHb. These aliquots were subsequently sorted into four sub-populations, ranging from no PS expression to high PS expression using a BD FACS ARIAIII. Each of these sub-fractions were introduced into the cell tracking velocimetry apparatus which measured both the magnetically-induced and the gravity-induced velocity. Subsequently, the samples were removed from the cell tracking velocimetry instrument and characterized using the Multisizer 4e Coulter Counter. From the magnetically-induced velocity, the amount of hemoglobin, in pg Hb per cell can be determined, and using an average value of the density of RBCs, the size can be determined. For the PS negative sub-fraction of RBCs, the size of the RBC was as expected but the average hemoglobin, Hb, content was below the threshold which defines anemia. In contrast, unexpected results were observed with the various levels of expression of PS. First, virtually all of the PS expressing cells were significantly smaller, on the order of 1 micron, than a normal RBC after 42 days of storage; yet the density of these small cells/microvesicles was such that they had settling velocities similar to normal-sized RBCs. Further, while the total amount of Hb per small cell/microvesicle was only approximately 25% of the full-sized RBCs, the volume of these small cells/microvesicles is only 1/200 of the PS negative RBCs. This suggests that these PS expressing cells are shrunken RBCs, or shrunken microvesicles from RBCs that concentrated the Hb internally. These results suggest not only a relationship between the loss of hemoglobin and the amount of PS exposed on the cellular outer wall, but also a mechanism by which these aged RBCs break down. It is not known at this time whether this is an artifact of storage or similar mechanisms occur in circulation within the human body.


Assuntos
Rastreamento de Células/métodos , Eritrócitos/metabolismo , Hemoglobinas/análise , Fosfatidilserinas/análise , Reologia/métodos , Análise de Célula Única/métodos , Humanos
8.
J Magn Magn Mater ; 474: 152-160, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-32863537

RESUMO

Paramagnetic constituents of a cell have strong effect on cell's volume magnetic susceptibility even at low volume fraction because of their high susceptibility relative to that of the diamagnetic cell constituents. The effect can be measured at a single cell level by measuring cell terminal velocity in viscous media using a microscope equipped with a well-defined field and gradient magnet configuration (referred to as magnetophoretic analysis by cell tracking velocimetry, CTV). The sensitivity of such a microscopic-scale magnetometry was compared to that of a reference method of superconducting quantum interference-magnetic properties measurement system (SQUID-MPMS) using a red blood cell (RBC) suspension model. The RBC hemoglobin oxygen saturation determines the hemoglobin molecular magnetic susceptibility (diamagnetic when fully oxygenated, paramagnetic when fully deoxygenated or converted to methemoglobin). The SQUID-MPMS measurements were performed on an average of 5,000 RBCs in 20 µL physiological phosphate buffer at room temperature, those by CTV on a single cell track in a mean magnetic field of 1.6 T and mean gradient of 240 T/m, repeated for an average of 1,000 tracks per sample. This suggests 5,000× higher sensitivity of cell susceptometry by magnetophoretic analysis than by SQUID-MPMS. The magnetophoretic mean RBC magnetic susceptibilities were in the range determined by SQUID-MPMS (lower limit) and theory (upper limit). The ability of magnetophoretic analysis to resolve susceptibility peaks in a mixed cell populations was confirmed for an oxy RBC and met RBC mixture. Magnetophoretic analysis by CTV provides new tool for studies of emergence of paramagnetic reaction products in the cell.

9.
Biotechnol Bioeng ; 115(5): 1288-1300, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29337367

RESUMO

Magnetic separation of cells has been, and continues to be, widely used in a variety of applications, ranging from healthcare diagnostics to detection of food contamination. Typically, these technologies require cells labeled with antibody magnetic particle conjugate and a high magnetic energy gradient created in the flow containing the labeled cells (i.e., a column packed with magnetically inducible material), or dense packing of magnetic particles next to the flow cell. Such designs, while creating high magnetic energy gradients, are not amenable to easy, highly detailed, mathematic characterization. Our laboratories have been characterizing and developing analysis and separation technology that can be used on intrinsically magnetic cells or spores which are typically orders of magnitude weaker than typically immunomagnetically labeled cells. One such separation system is magnetic deposition microscopy (MDM) which not only separates cells, but deposits them in specific locations on slides for further microscopic analysis. In this study, the MDM system has been further characterized, using finite element and computational fluid mechanics software, and separation performance predicted, using a model which combines: 1) the distribution of the intrinsic magnetophoretic mobility of the cells (spores); 2) the fluid flow within the separation device; and 3) accurate maps of the values of the magnetic field (max 2.27 T), and magnetic energy gradient (max of 4.41 T2 /mm) within the system. Guided by this model, experimental studies indicated that greater than 95% of the intrinsically magnetic Bacillus spores can be separated with the MDM system. Further, this model allows analysis of cell trajectories which can assist in the design of higher throughput systems.


Assuntos
Bacillus/isolamento & purificação , Separação Celular/métodos , Eritrócitos , Magnetismo/métodos , Microfluídica/métodos , Esporos Bacterianos/isolamento & purificação , Separação Celular/instrumentação , Análise de Elementos Finitos , Magnetismo/instrumentação , Microfluídica/instrumentação , Modelos Teóricos
10.
Biotechnol Bioeng ; 115(6): 1521-1530, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29476625

RESUMO

The ability to separate RBCs from the other components of whole blood has a number of useful clinical and research applications ranging from removing RBCs from typical clinical blood draw, bone marrow transplants to transfusions of these RBCs to patients after significant blood loss. Viewed from a mechanistic/process perspective, there are three routine methodologies to remove RBCs: 1) RBCs lysis, 2) separation of the RBCs from the nucleated cells (i.e., stem cells) based on density differences typically facilitated through centrifugation or sedimentation agents, and 3) antibody based separation in which a targeted RBC is bound with an affinity ligand that facilitates its removal. More recently, several microfluidic based techniques have also been reported. In this report, we describe the performance of continuous RBC separation achieved by the deflection of intrinsically magnetic, deoxygenated RBCs as they flow through a magnetic energy gradient created by quadrupole magnet. This quadrupole magnetic, with aperture of 9.65 mm, has a maximum field of B0 = 1.36 T at the pole tips and a constant field gradient of B0 /r0 = 286 T/m. The annular flow channel, contained within this quadrupole magnet, is 203 mm long, has an inner radius of 3.98 mm, and an inner, outer radius of 4.36 mm, which corresponds to an annulus radius of 380 micrometer. At the entrance and exit to this annular channel, a manifold was designed which allows a cell suspension and sheath fluid to be injected, and a RBC enriched exit flow (containing the magnetically deflected RBCs) and a RBC depleted exit flow to be collected. Guided by theoretical models previously published, a limited number of operating parameters; total flow rate, flow rate ratios of flows in and flow out, and ratios of RBC to polystyrene control beads was tested. The overall performance of this system is consistent with our previously presented, theoretical models and our intuition. As expected, the normalized recovery of RBCs in the RBC exit fraction ranged from approximately 95% down to 60%, as the total flow rate through the system increased from 0.1 to 0.6 ml/min. At the cell concentrations studied, this corresponds to a flow rate of 1.5 × 106 -9 × 106 cells/min. While the throughput of these pilot scale studies are slow for practical applications, the general agreement with theory, and the small cross-sectional area in which the actual separation is achieved, 77 mm2 (annulus radius times the length), and corresponding volume of approximately 2 mls, suggests the potential to scale-up a system for practical applications exists and is actively being pursued.


Assuntos
Separação Celular/métodos , Eritrócitos , Imãs , Separação Celular/instrumentação , Humanos
11.
J Magn Magn Mater ; 427: 325-330, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29104346

RESUMO

Emerging microfluidic-based cell assays favor label-free red blood cell (RBC) depletion. Magnetic separation of RBC is possible because of the paramagnetism of deoxygenated hemoglobin but the process is slow for open-gradient field configurations. In order to increase the throughput, periodic arrangements of the unit magnets were considered, consisting of commercially available Nd-Fe-B permanent magnets and soft steel flux return pieces. The magnet design is uniquely suitable for multiplexing by magnet tessellation, here meaning the tiling of the magnet assembly cross-sectional plane by periodic repetition of the magnet and the flow channel shapes. The periodic pattern of magnet magnetizations allows a reduction of the magnetic material per channel with minimal distortion of the field cylindrical symmetry inside the magnet apertures. A number of such magnet patterns are investigated for separator performance, size and economy with the goal of designing an open-gradient magnetic separator capable of reducing the RBC number concentration a hundred-fold in 1 mL whole blood per hour.

12.
Malar J ; 15: 113, 2016 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-26911917

RESUMO

BACKGROUND: Conventional malaria parasite detection methods, such as rapid diagnostic tests (RDT) and light microscopy (LM), are not sensitive enough to detect low level parasites and identification of gametocytes in the peripheral blood. A modified and sensitive laboratory prototype, Magnetic Deposition Microscopy (MDM) was developed to increase the detection of sub-microscopic parasitaemia and estimation of gametocytes density in asymptomatic school children. METHODS: Blood samples were collected from 303 asymptomatic school children from seven villages in Bagamoyo district in Tanzania. Participants were screened for presence of malaria parasites in the field using RDT and MDM whereas further examination of malaria parasites was done in the laboratory by LM. LM and MDM readings were used to calculate densities and estimate prevalence of asexual and sexual stages of the parasite. RESULTS: Plasmodium falciparum parasites (asexual and sexual stages) were detected in 23 (7.6 %), 52 (17.2 %), and 59 (19.5 %) out of 303 samples by LM, RDT and MDM respectively. Gametocytes were detected in 4 (1.3 %) and 12 (4.0 %) out of the same numbers of samples by LM, and MDM, respectively. Likewise, in vitro results conducted on two laboratory strains of P. falciparum, 3D7 and NF54 to assess MDM sensitivity on gametocytes detection and its application on concentrating gametocytes indicated that gametocytes were enriched by MDM by 10-fold higher than LM. Late stages of the parasite strains, 3D7 and NF54 were enriched by MDM by a factor of 20.5 and 35.6, respectively. MDM was more specific than LM and RDT by 87.5 % (95 %, CI 71.2-89.6 %) and 89.0 % (95 % CI 82.9-91.4) respectively. It was also found that MDM sensitivity was 62.5 % (95 % CI 49.5-71.8) when compared with RDT while with LM was 36.5 % (95 % CI 32.2-60.5). CONCLUSIONS: These findings provide strong evidence that MDM enhanced detection of sub-microscopic P. falciparum infections and estimation of gametocyte density compared to current malaria diagnostic tools. In addition, MDM is superior to LM in detecting sub-microscopic gametocytaemia. Therefore, MDM is a potential tool for low-level parasitaemia identification and quantification with possible application in malaria transmission research.


Assuntos
Malária Falciparum/parasitologia , Microscopia/métodos , Carga Parasitária/métodos , Plasmodium falciparum/isolamento & purificação , Adolescente , Infecções Assintomáticas , Criança , Estudos Transversais , Humanos , Parasitemia/parasitologia , Sensibilidade e Especificidade , Tanzânia
14.
Anal Chem ; 87(19): 9908-15, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26368657

RESUMO

Connective tissue progenitors (CTPs) are a promising therapeutic agent for bone repair. Hyaluronan, a high molecular mass glycosaminoglycan, has been shown by us to be a suitable biomarker for magnetic separation of CTPs from bone marrow aspirates in a canine model. For the therapy to be applicable in humans, the magnetic separation process requires scale-up without compromising the viability of the cells. The scaled-up device presented here utilizes a circular Halbach array of diametrically magnetized, cylindrical permanent magnets. This allows precise control of the magnetic field gradient driving the separation, with theoretical analysis favoring a hexapole field. The separation vessel has the external diameter of a 50 mL conical centrifuge tube and has an internal rod that excludes cells from around the central axis. The magnet and separation vessel (collectively dubbed the hexapole magnet separator or HMS) was tested on four human and four canine bone marrow aspirates. Each CTP-enriched cell product was tested using cell culture bioassays as surrogates for in vivo engraftment quality. The magnetically enriched cell fractions showed statistically significant, superior performance compared to the unenriched and depleted cell fractions for all parameters tested, including CTP prevalence (CTPs per 10(6) nucleated cells), proliferation by colony forming unit (CFU) counts, and differentiation by staining for the presence of osteogenic and chondrogenic cells. The simplicity and speed of the HMS operation could allow both CTP isolation and engraftment during a single surgical procedure, minimizing trauma to patients and lowering cost to health care providers.


Assuntos
Células da Medula Óssea/citologia , Separação Celular/instrumentação , Ácido Hialurônico/análise , Magnetismo/instrumentação , Animais , Diferenciação Celular , Células Cultivadas , Cães , Desenho de Equipamento , Humanos , Células-Tronco/citologia
15.
J Magn Magn Mater ; 380: 201-204, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29353957

RESUMO

Algae were investigated in the past as a potential source of biofuel and other useful chemical derivatives. Magnetic separation of algae by iron oxide nanoparticle binding to cells has been proposed by others for dewatering of cellular mass prior to lipid extraction. We have investigated feasibility of magnetic separation based on the presence of natural iron stores in the cell, such as the ferritin in Auxenochlorella protothecoides (A. p.) strains. The A. p. cell constructs were tested for inserted genes and for increased intracellular iron concentration by inductively coupled plasma atomic absorption (ICP-AA). They were grown in Sueoka's modified high salt media with added vitamin B1 and increasing concentration of soluble iron compound (FeCl3 EDTA, from 1× to 8× compared to baseline). The cell magnetic separation conditions were tested using a thin rectangular flow channel pressed against interpolar gaps of a permanent magnet forming a separation system of a well-defined fluid flow and magnetic fringing field geometry (up to 2.2 T and 1,000 T/m) dubbed "magnetic deposition microscopy", or MDM. The presence of magnetic cells in suspension was detected by formation of characteristic deposition bands at the edges of the magnet interpolar gaps, amenable to optical scanning and microscopic examination. The results demonstrated increasing cellular Fe uptake with increasing Fe concentration in the culture media in wild type strain and in selected genetically-modified constructs, leading to magnetic separation without magnetic particle binding. The throughput in this study is not sufficient for an economical scale harvest.

16.
Anal Bioanal Chem ; 406(6): 1661-70, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24141316

RESUMO

Emerging applications of rare cell separation and analysis, such as separation of mature red blood cells from hematopoietic cell cultures, require efficient methods of red blood cell (RBC) debulking. We have tested the feasibility of magnetic RBC separation as an alternative to centrifugal separation using an approach based on the mechanism of magnetic field-flow fractionation (MgFFF). A specially designed permanent magnet assembly generated a quadrupole field having a maximum field of 1.68 T at the magnet pole tips, zero field at the aperture axis, and a nearly constant radial field gradient of 1.75 T/mm (with a negligible angular component) inside a cylindrical aperture of 1.9 mm (diameter) and 76 mm (length). The cell samples included high-spin hemoglobin RBCs obtained by chemical conversion of hemoglobin to methemoglobin (met RBC) or by exposure to anoxic conditions (deoxy RBC), low-spin hemoglobin obtained by exposure of RBC suspension to ambient air (oxy RBC), and mixtures of deoxy RBC and cells from a KG-1a white blood cell (WBC) line. The observation that met RBCs did not elute from the channel at the lower flow rate of 0.05 mL/min applied for 15 min but quickly eluted at the subsequent higher flow rate of 2.0 mL/min was in agreement with FFF theory. The well-defined experimental conditions (precise field and flow characteristics) and a well-established FFF theory verified by studies with model cell systems provided us with a strong basis for making predictions about potential practical applications of the magnetic RBC separation.


Assuntos
Separação Celular/instrumentação , Eritrócitos/citologia , Fracionamento por Campo e Fluxo/instrumentação , Magnetismo/instrumentação , Separação Celular/métodos , Desenho de Equipamento , Eritrócitos/química , Estudos de Viabilidade , Fracionamento por Campo e Fluxo/métodos , Hemoglobinas/química , Humanos , Leucócitos/citologia , Campos Magnéticos , Magnetismo/métodos , Metemoglobina/química , Oxirredução
17.
Methods ; 64(2): 169-82, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24056212

RESUMO

A variety of enrichment/isolation technologies exist for the characterization of rare cells in the blood of cancer patients. In this article, a negative depletion process is presented and discussed which consists of red blood cell (RBC) lysis and the subsequent removal of CD45 expressing cells through immunomagnetic depletion. Using this optimized assembly on 120 whole blood specimens, from 71 metastatic breast cancer patients, after RBC lysis, the average nucleated cell log depletion was 2.56 with a 77% recovery of the nucleated cells. The necessity of exploring different anti-CD45 antibody clones to label CD45 expressing cells in this enrichment scheme is also presented and discussed. An optimized, four-color immunofluorescence staining is conducted on the cells retained after the CD45-based immunomagnetic depletion process. Different types of rare non-hematopoietic cells are found in these enriched peripheral blood samples and a wide range of external and internal markers have been characterized, which demonstrates the range and heterogeneity of the rare cells.


Assuntos
Separação Imunomagnética/métodos , Antígenos Comuns de Leucócito/imunologia , Células Neoplásicas Circulantes/imunologia , Biomarcadores Tumorais/análise , Neoplasias da Mama/imunologia , Contagem de Células , Linhagem Celular Tumoral , Feminino , Citometria de Fluxo , Imunofluorescência , Humanos
18.
Bioelectromagnetics ; 35(6): 396-405, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24764277

RESUMO

Delayed bone healing has been noted in osteoporosis patients and in the ovariectomized (OVX) rat model of estrogen-depletion osteopenia. Pulsed electromagnetic field (PEMF) devices are clinically approved as an adjunct to cervical fusion surgery in patients at high risk for non-fusion and for the treatment of fracture non-unions. These bone growth stimulating devices also accelerate the healing of fresh fracture repair in skeletally mature normal rats but have not been tested for efficacy to accelerate and/or enhance the delayed bone repair process in OVX rats. The current study tested the hypothesis that daily PEMF treatments would improve the fracture healing response in skeletally mature OVX rats. By 6 weeks of healing, PEMF treatments resulted in improved hard callus elastic modulus across fibula fractures normalizing the healing process in OVX rats with respect to this mechanical property. Radiographic evidence showed an improved hard callus bridging across fibula fractures in OVX rats treated with PEMF as compared to sham treatments. These findings provide a scientific rationale for investigating whether PEMF might improve bone-healing responses in at-risk osteoporotic patients.


Assuntos
Calo Ósseo/fisiopatologia , Consolidação da Fratura/fisiologia , Magnetoterapia/métodos , Fraturas por Osteoporose/terapia , Animais , Doenças Ósseas Metabólicas , Calo Ósseo/diagnóstico por imagem , Modelos Animais de Doenças , Módulo de Elasticidade , Feminino , Fíbula/diagnóstico por imagem , Fíbula/lesões , Fíbula/fisiopatologia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Ovariectomia , Distribuição Aleatória , Ratos Sprague-Dawley , Fatores de Tempo , Microtomografia por Raio-X
19.
Nanoscale ; 16(14): 7041-7057, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38444246

RESUMO

Magnetic nanoparticles (MNPs) have recently gained significant attention in various fields, including chemical and biomedical applications, due to their exceptional properties. However, separating MNPs from solution via magnetophoresis is challenging when MNPs are smaller than 50 nm as Brownian forces become on the order of the magnetic forces. In this study, we successfully separated small MNPs (5-30 nm) by utilizing high magnetic fields and gradients generated by economical permanent magnets. In situ small angle X-ray scattering (SAXS) was used to investigate the time-dependent concentration changes in the ferrofluid, and the results validated that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole-dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm. However, numerical simulations have provided further validation that in the absence of particle-particle interactions, even MNPs with diameters less than 15 nm exhibited magnetophoresis that effectively counteracted the effects of Brownian motion.

20.
IEEE Trans Magn ; 49(1): 309-315, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24910468

RESUMO

The emerging applications of biological cell separation to rare circulating tumor cell (CTC) detection and separation from blood rely on efficient methods of red blood cell (RBC) debulking. The two most widely used methods of centrifugation and RBC lysis have been associated with the concomitant significant losses of the cells of interest (such as progenitor cells or circulating tumor cells). Moreover, RBC centrifugation and lysis are not well adapted to the emerging diagnostic applications, relying on microfluidics and micro-scale total analytical systems. Therefore, magnetic RBC separation appears a logical alternative considering the high iron content of the RBC (normal mean 105 fg) as compared to the white blood cell iron content (normal mean 1.6 fg). The typical magnetic forces acting on a RBC are small, however, as compared to typical forces associated with centrifugation or the forces acting on synthetic magnetic nanoparticles used in current magnetic cell separations. This requires a significant effort in designing and fabricating a practical magnetic RBC separator. Applying advanced designs to the low cost, high power permanent magnets currently available, and building on the accumulated knowledge of the immunomagnetic cell separation methods and devices, an open gradient magnetic red blood cell (RBC) sorter was designed, fabricated and tested on label-free cell mixtures, with potential applications to RBC debulking from whole blood samples intended for diagnostic tests.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA