RESUMO
INTRODUCTION: Glioblastoma (GBM) is the most common central nervous system malignancy in adults. Despite decades of developments in surgical management, radiation treatment, chemotherapy, and tumor treating field therapy, GBM remains an ultimately fatal disease. There is currently no definitive standard of care for patients with recurrent glioblastoma (rGBM) following failure of initial management. OBJECTIVE: In this retrospective cohort study, we set out to examine the relative effects of bevacizumab and Gamma Knife radiosurgery on progression-free survival (PFS) and overall survival (OS) in patients with GBM at first-recurrence. METHODS: We conducted a retrospective review of all patients with rGBM who underwent treatment with bevacizumab and/or Gamma Knife radiosurgery at Roswell Park Comprehensive Cancer Center between 2012 and 2022. Mean PFS and OS were determined for each of our three treatment groups: Bevacizumab Only, Bevacizumab Plus Gamma Knife, and Gamma Knife Only. RESULTS: Patients in the combined treatment group demonstrated longer post-recurrence median PFS (7.7 months) and median OS (11.5 months) compared to glioblastoma patients previously reported in the literature, and showed improvements in total PFS (p=0.015), total OS (p=0.0050), post-recurrence PFS (p=0.018), and post-recurrence OS (p=0.0082) compared to patients who received either bevacizumab or Gamma Knife as monotherapy. CONCLUSION: This study demonstrates that the combined use of bevacizumab with concurrent stereotactic radiosurgery can have improve survival in patients with rGBM.
Assuntos
Neoplasias Encefálicas , Glioblastoma , Radiocirurgia , Adulto , Humanos , Bevacizumab/uso terapêutico , Glioblastoma/radioterapia , Glioblastoma/tratamento farmacológico , Radiocirurgia/efeitos adversos , Estudos Retrospectivos , Neoplasias Encefálicas/tratamento farmacológico , Recidiva Local de Neoplasia/tratamento farmacológico , Resultado do TratamentoRESUMO
Renal perfusion can be quantitatively assessed by multiple magnetic resonance imaging (MRI) methods, including dynamic contrast enhanced (DCE), arterial spin labeling (ASL), and diffusion-weighted imaging with intravoxel incoherent motion (IVIM) analysis. In this review we summarize the advances in the field of renal-perfusion MRI over the past 5 years. The review starts with a brief introduction of relevant MRI methods, followed by a discussion of recent technical developments. In the main section of the review, we examine the clinical and preclinical applications for three disease populations: chronic kidney disease, renal transplant, and renal tumors. The DCE method has been routinely used for assessing renal tumors but not other renal diseases. As a noncontrast alternative, ASL was extensively explored in both preclinical and clinical applications and showed much promise. Protocol standardization for the methods is desperately needed, and then large-scale clinical trials for the methods can be initiated prior to their broad clinical use. Level of Evidence: 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;52:369-379.
Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Meios de Contraste , Humanos , Movimento (Física) , Perfusão , Imagem de Perfusão , Marcadores de SpinRESUMO
Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.
Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Animais , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Humanos , Rim/metabolismo , Imageamento por Ressonância Magnética/normas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendênciasRESUMO
OBJECTIVES: This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS: An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS: Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION: This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.
Assuntos
Circulação Cerebrovascular , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Marcadores de Spin , Pesquisa Translacional Biomédica/tendências , Algoritmos , Consenso , Técnica Delphi , Imagem Ecoplanar , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Transplante de Rim , Angiografia por Ressonância Magnética , Estudos Multicêntricos como Assunto , Perfusão , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-RuídoRESUMO
Peripheral artery disease (PAD) in the lower extremities often leads to intermittent claudication. In the present study, we proposed a low-dose DCE MRI protocol for quantifying calf muscle perfusion stimulated with plantar flexion and multiple new metrics for interpreting perfusion maps, including the ratio of gastrocnemius over soleus perfusion (G/S; for assessing the vascular redistribution between the two muscles) and muscle perfusion normalized by whole body perfusion (for quantifying the muscle's active hyperemia). Twenty-eight human subjects participated in this Institutional Review Board-approved study, with 10 healthy subjects ( group A) for assessing interday reproducibility and 8 healthy subjects ( group B) for exploring the relationship between plantar-flexion load and induced muscle perfusion. In a pilot group of five elderly healthy subjects and five patients with PAD ( group C), we proposed a protocol that measured perfusion for a low-intensity exercise and for an exhaustion exercise in a single MRI session. In group A, perfusion estimates for calf muscles were highly reproducible, with correlation coefficients of 0.90-0.93. In group B, gastrocnemius perfusion increased linearly with the exercise workload ( P < 0.05). With the low-intensity exercise, patients with PAD in group C showed substantially lower gastrocnemius perfusion compared with elderly healthy subjects [43.4 (SD 23.5) vs. 106.7 (SD 73.2) ml·min-1·100 g-1]. With exhaustion exercise, G/S [1.0 (SD 0.4)] for patients with PAD was lower than both its low-intensity level [1.9 (SD 1.3)] and the level in elderly healthy subjects [2.7 (SD 2.1)]. In conclusion, the proposed MRI protocol and the new metrics are feasible for quantifying exercise-induced muscle hyperemia, a promising functional test of PAD. NEW & NOTEWORTHY To quantitatively map exercise-induced hyperemia in calf muscles, we proposed a high-resolution MRI method shown to be highly reproducible and sensitive to exercise load. With the use of low contrast, it is feasible to measure calf muscle hyperemia for both low-intensity and exhaustion exercises in a single MRI session. The newly proposed metrics for interpreting perfusion maps are promising for quantifying intermuscle vascular redistribution or a muscle's active hyperemia.
Assuntos
Exercício Físico , Hiperemia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Adulto , Tornozelo/irrigação sanguínea , Tornozelo/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagemRESUMO
Polycomb repressive complex 2 (PRC2) consists of three core subunits, EZH2, EED and SUZ12, and plays pivotal roles in transcriptional regulation. The catalytic subunit EZH2 methylates histone H3 lysine 27 (H3K27), and its activity is further enhanced by the binding of EED to trimethylated H3K27 (H3K27me3). Small-molecule inhibitors that compete with the cofactor S-adenosylmethionine (SAM) have been reported. Here we report the discovery of EED226, a potent and selective PRC2 inhibitor that directly binds to the H3K27me3 binding pocket of EED. EED226 induces a conformational change upon binding EED, leading to loss of PRC2 activity. EED226 shows similar activity to SAM-competitive inhibitors in blocking H3K27 methylation of PRC2 target genes and inducing regression of human lymphoma xenograft tumors. Interestingly, EED226 also effectively inhibits PRC2 containing a mutant EZH2 protein resistant to SAM-competitive inhibitors. Together, we show that EED226 inhibits PRC2 activity via an allosteric mechanism and offers an opportunity for treatment of PRC2-dependent cancers.
Assuntos
Antineoplásicos/farmacologia , Histonas/metabolismo , Lisina/metabolismo , Complexo Repressor Polycomb 2/antagonistas & inibidores , Sulfonas/química , Sulfonas/farmacologia , Triazóis/química , Triazóis/farmacologia , Regulação Alostérica/efeitos dos fármacos , Animais , Antineoplásicos/química , Sítios de Ligação/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Feminino , Histonas/química , Humanos , Lisina/química , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Modelos Moleculares , Estrutura Molecular , Neoplasias Experimentais/tratamento farmacológico , Neoplasias Experimentais/patologia , Complexo Repressor Polycomb 2/química , Complexo Repressor Polycomb 2/metabolismo , Relação Estrutura-Atividade , Sulfonas/metabolismo , Triazóis/metabolismo , Células Tumorais CultivadasRESUMO
Glomerular fibrosis occurs in the early stages of multiple renal diseases, including hypertensive and diabetic nephropathy. Conventional assessment of glomerular fibrosis relies on kidney biopsy, which is invasive and does not reflect physiological aspects such as blood perfusion. In this study, we sought to assess potential changes of cortical perfusion and microstructure at different degrees of glomerular fibrosis using magnetic resonance imaging (MRI). A rat model of glomerular fibrosis was induced by injecting anti-Thy-1 monoclonal antibody OX-7 to promote mesangial extracellular matrix proliferation. For six rats on day 5 and five rats on day 12 after the induction, we measured renal cortical perfusion and spin-spin relaxation time (T2) in a 3-Tesla MRI scanner. T2 reflects tissue microstructural changes. Glomerular fibrosis severity was evaluated by histological analysis and proteinuria. Four rats without fibrosis were included as controls. In the control rats, the periodic acid-Schiff (PAS)-positive area was 22 ± 1% of total glomerular tuft, which increased significantly to 56 ± 12% and 45 ± 10% in the day 5 and day 12 fibrotic groups, respectively ( P < 0.01). For the three groups (control, day 5, and day 12 after OX-7 injection), cortical perfusion was 7.27 ± 2.54, 3.78 ± 2.17, and 3.32 ± 2.62 ml·min-1·g-1, respectively, decreasing with fibrosis severity ( P < 0.01), and cortical T2 was 75.2 ± 4.6, 84.1 ± 3.0, and 87.9 ± 5.6 ms, respectively ( P < 0.01). In conclusion, extracellular matrix proliferation in glomerular mesangial cells severely diminished blood flow through the glomeruli and also altered cortical microstructure to increase cortical T2. The MRI-measured parameters are proven to be sensitive markers for characterizing glomerular fibrosis.
Assuntos
Mesângio Glomerular/irrigação sanguínea , Mesângio Glomerular/diagnóstico por imagem , Glomerulonefrite/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem de Perfusão/métodos , Circulação Renal , Albuminúria/diagnóstico por imagem , Albuminúria/patologia , Animais , Velocidade do Fluxo Sanguíneo , Proliferação de Células , Modelos Animais de Doenças , Progressão da Doença , Estudos de Viabilidade , Fibrose , Mesângio Glomerular/patologia , Glomerulonefrite/patologia , Glomerulonefrite/fisiopatologia , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Ratos Sprague-Dawley , Índice de Gravidade de Doença , Fatores de TempoRESUMO
Magnetic resonance imaging (MRI) has been used for many years for anatomic evaluation of the kidney. Recently developed methods attempt to go beyond anatomy to give information about the health and function of the kidneys. Several methods, including diffusion-weighted MRI, renal blood oxygen level-dependent MRI, renal MR elastography, and renal susceptibility imaging, show promise for providing unique insight into kidney function and severity of fibrosis. However, substantial limitations in accuracy and practicality limit the immediate clinical application of each method. Further development and improvement are necessary to achieve the ideal of a noninvasive image-based measure of renal fibrosis. Our brief review provides a short explanation of these emerging MRI methods and outlines the promising initial results obtained with each as well as current limitations and barriers to clinical implementation.
Assuntos
Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Fibrose , Humanos , Rim/irrigação sanguínea , Oxigênio/sangueRESUMO
PURPOSE: Blood oxygen level-dependent (BOLD) MRI has been effectively used to monitor changes in renal oxygenation. However, R2* (or T2*) is not specific to blood oxygenation and is dependent on other factors. This study investigates the use of a statistical model that takes these factors into account and maps BOLD MRI measurements to blood pO2. METHODS: Spin echo and gradient echo images were obtained in six Sprague-Dawley rats and R2 and R2* maps were computed. Measurements were made at baseline, post-nitric oxide synthase inhibitor (L-NAME), and post-furosemide administration. A simulation of each region was performed to map R2' (computed as R2*-R2) to blood pO2. RESULTS: At baseline, blood pO2 in the outer medulla was 30.5 ± 1.2 mmHg and 51.9 ± 5.2 mmHg in the cortex, in agreement with previous invasive studies. Blood pO2 was found to decrease within the outer medulla following L-NAME (P < 0.05) and increase after furosemide (P < 0.05). Blood pO2 in the cortex increased following furosemide (P < 0.05). CONCLUSIONS: Model-derived blood pO2 is sensitive to pharmacological challenges, and baseline pO2 is comparable to literature values. Reporting pO2 instead of R2* could lead to a greater clinical impact of renal BOLD MRI and facilitate the identification of hypoxic regions. Magn Reson Med 78:297-302, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Rim/diagnóstico por imagem , Rim/metabolismo , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Animais , Furosemida/administração & dosagem , Rim/efeitos dos fármacos , Masculino , NG-Nitroarginina Metil Éster/administração & dosagem , Oximetria/métodos , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
MRI can provide excellent detail of renal structure and function. Recently, novel MR contrast mechanisms and imaging tools have been developed to evaluate microscopic kidney structures including the tubules and glomeruli. Quantitative MRI can assess local tubular function and is able to determine the concentrating mechanism of the kidney noninvasively in real time. Measuring single nephron function is now a near possibility. In parallel to advancing imaging techniques for kidney microstructure is a need to carefully understand the relationship between the local source of MRI contrast and the underlying physiological change. The development of these imaging markers can impact the accurate diagnosis and treatment of kidney disease. This study reviews the novel tools to examine kidney microstructure and local function and demonstrates the application of these methods in renal pathophysiology.
Assuntos
Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Néfrons/diagnóstico por imagem , Animais , Humanos , Rim/patologia , Rim/fisiopatologia , Nefropatias/patologia , Nefropatias/fisiopatologia , Néfrons/patologia , Néfrons/fisiopatologiaRESUMO
Dynamic contrast-enhanced (DCE) MRI can provide key insight into renal function. DCE MRI is typically achieved through an injection of a gadolinium (Gd)-based contrast agent, which has desirable T1 quenching and tracer kinetics. However, significant T2* blooming effects and signal voids can arise when Gd becomes very concentrated, especially in the renal medulla and pelvis. One MRI sequence designed to alleviate T2* effects is the ultrashort echo time (UTE) sequence. In the present study, we observed T2* blooming in the inner medulla of the mouse kidney, despite using UTE at an echo time of 20 microseconds and a low dose of 0.03 mmol/kg Gd. We applied quantitative susceptibility mapping (QSM) and resolved the signal void into a positive susceptibility signal. The susceptibility values [in parts per million (ppm)] were converted into molar concentrations of Gd using a calibration curve. We determined the concentrating mechanism (referred to as the concentrating index) as a ratio of maximum Gd concentration in the inner medulla to the renal artery. The concentrating index was assessed longitudinally over a 17-wk course (3, 5, 7, 9, 13, 17 wk of age). We conclude that the UTE-based DCE method is limited in resolving extreme T2* content caused by the kidney's strong concentrating mechanism. QSM was able to resolve and confirm the source of the blooming effect to be the large positive susceptibility of concentrated Gd. UTE with QSM can complement traditional magnitude UTE and offer a powerful tool to study renal pathophysiology.
Assuntos
Rim/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Animais , Meios de Contraste , Rim/patologia , CamundongosRESUMO
Dynamic contrast-enhanced (DCE) MRI is widely used for the measurement of tissue perfusion and to assess organ function. MR renography, which is acquired using a DCE sequence, can measure renal perfusion, filtration and concentrating ability. Optimization of the DCE acquisition protocol is important for the minimization of the error propagation from the acquired signals to the estimated parameters, thus improving the precision of the parameters. Critical to the optimization of contrast-enhanced T1 -weighted protocols is the balance of the T1 -shortening effect across the range of gadolinium (Gd) contrast concentration in the tissue of interest. In this study, we demonstrate a Monte Carlo simulation approach for the optimization of DCE MRI, in which a saturation-recovery T1 -weighted gradient echo sequence is simulated and the impact of injected dose (D) and time delay (TD, for saturation recovery) is tested. The results show that high D and/or high TD cause saturation of the peak arterial signals and lead to an overestimation of renal plasma flow (RPF) and glomerular filtration rate (GFR). However, the use of low TD (e.g. 100 ms) and low D leads to similar errors in RPF and GFR, because of the Rician bias in the pre-contrast arterial signals. Our patient study including 22 human subjects compared TD values of 100 and 300 ms after the injection of 4 mL of Gd contrast for MR renography. At TD = 100 ms, we computed an RPF value of 157.2 ± 51.7 mL/min and a GFR of 33.3 ± 11.6 mL/min. These results were all significantly higher than the parameter estimates at TD = 300 ms: RPF = 143.4 ± 48.8 mL/min (p = 0.0006) and GFR = 30.2 ± 11.5 mL/min (p = 0.0015). In conclusion, appropriate optimization of the DCE MRI protocol using simulation can effectively improve the precision and, potentially, the accuracy of the measured parameters. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Taxa de Filtração Glomerular/fisiologia , Compostos Heterocíclicos/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Rim/metabolismo , Imageamento por Ressonância Magnética/métodos , Método de Monte Carlo , Compostos Organometálicos/farmacocinética , Simulação por Computador , Meios de Contraste/farmacocinética , Feminino , Gadolínio/farmacocinética , Humanos , Aumento da Imagem/métodos , Rim/diagnóstico por imagem , Masculino , Modelos Biológicos , Modelos Estatísticos , Renografia por Radioisótopo/métodos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
PURPOSE: To assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease. MATERIALS AND METHODS: Thirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 30 ± 27 days of MRI. RESULTS: ADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5) ). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P = 0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P = 0.3/0.03; medulla r/P = 0.27/0.05) and ADC (cortex r/P = 0.28/0.04; medulla r/P = 0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P = 0.32/10(-3) ) and with ADC (r/P = 0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P = -0.38/0.004) and D*×PF (r/P = -0.34/0.01). CONCLUSION: The weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.
Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Rim/diagnóstico por imagem , Rim/fisiopatologia , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Idoso , Algoritmos , Simulação por Computador , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
PURPOSE: To evaluate the performance of an edge-based registration technique in correcting for respiratory motion artifacts in magnetic resonance renographic (MRR) data and to examine the efficiency of a semiautomatic software package in processing renographic data from a cohort of clinical patients. MATERIALS AND METHODS: The developed software incorporates an image-registration algorithm based on the generalized Hough transform of edge maps. It was used to estimate glomerular filtration rate (GFR), renal plasma flow (RPF), and mean transit time (MTT) from 36 patients who underwent free-breathing MRR at 3T using saturation-recovery turbo-FLASH. The processing time required for each patient was recorded. Renal parameter estimates and model-fitting residues from the software were compared to those from a previously reported technique. Interreader variability in the software was quantified by the standard deviation of parameter estimates among three readers. GFR estimates from our software were also compared to a reference standard from nuclear medicine. RESULTS: The time taken to process one patient's data with the software averaged 12 ± 4 minutes. The applied image registration effectively reduced motion artifacts in dynamic images by providing renal tracer-retention curves with significantly smaller fitting residues (P < 0.01) than unregistered data or data registered by the previously reported technique. Interreader variability was less than 10% for all parameters. GFR estimates from the proposed method showed greater concordance with reference values (P < 0.05). CONCLUSION: These results suggest that the proposed software can process MRR data efficiently and accurately. Its incorporated registration technique based on the generalized Hough transform effectively reduces respiratory motion artifacts in free-breathing renographic acquisitions.
Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Nefropatias/patologia , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos TestesRESUMO
The four receptors of the Notch family are widely expressed transmembrane proteins that function as key conduits through which mammalian cells communicate to regulate cell fate and growth. Ligand binding triggers a conformational change in the receptor negative regulatory region (NRR) that enables ADAM protease cleavage at a juxtamembrane site that otherwise lies buried within the quiescent NRR. Subsequent intramembrane proteolysis catalysed by the gamma-secretase complex liberates the intracellular domain (ICD) to initiate the downstream Notch transcriptional program. Aberrant signalling through each receptor has been linked to numerous diseases, particularly cancer, making the Notch pathway a compelling target for new drugs. Although gamma-secretase inhibitors (GSIs) have progressed into the clinic, GSIs fail to distinguish individual Notch receptors, inhibit other signalling pathways and cause intestinal toxicity, attributed to dual inhibition of Notch1 and 2 (ref. 11). To elucidate the discrete functions of Notch1 and Notch2 and develop clinically relevant inhibitors that reduce intestinal toxicity, we used phage display technology to generate highly specialized antibodies that specifically antagonize each receptor paralogue and yet cross-react with the human and mouse sequences, enabling the discrimination of Notch1 versus Notch2 function in human patients and rodent models. Our co-crystal structure shows that the inhibitory mechanism relies on stabilizing NRR quiescence. Selective blocking of Notch1 inhibits tumour growth in pre-clinical models through two mechanisms: inhibition of cancer cell growth and deregulation of angiogenesis. Whereas inhibition of Notch1 plus Notch2 causes severe intestinal toxicity, inhibition of either receptor alone reduces or avoids this effect, demonstrating a clear advantage over pan-Notch inhibitors. Our studies emphasize the value of paralogue-specific antagonists in dissecting the contributions of distinct Notch receptors to differentiation and disease and reveal the therapeutic promise in targeting Notch1 and Notch2 independently.
Assuntos
Anticorpos/farmacologia , Anticorpos/uso terapêutico , Neoplasias/tratamento farmacológico , Neoplasias/metabolismo , Receptores Notch/antagonistas & inibidores , Inibidores da Angiogênese/imunologia , Inibidores da Angiogênese/farmacologia , Inibidores da Angiogênese/uso terapêutico , Animais , Anticorpos/efeitos adversos , Anticorpos/imunologia , Especificidade de Anticorpos/imunologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Células Caliciformes/efeitos dos fármacos , Células Caliciformes/patologia , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Células NIH 3T3 , Neoplasias/irrigação sanguínea , Neoplasias/patologia , Neovascularização Patológica/tratamento farmacológico , Biblioteca de Peptídeos , Leucemia-Linfoma Linfoblástico de Células T Precursoras/tratamento farmacológico , Leucemia-Linfoma Linfoblástico de Células T Precursoras/metabolismo , Leucemia-Linfoma Linfoblástico de Células T Precursoras/patologia , Receptor Notch1/antagonistas & inibidores , Receptor Notch1/imunologia , Receptor Notch2/antagonistas & inibidores , Receptor Notch2/imunologia , Receptores Notch/genética , Receptores Notch/imunologia , Receptores Notch/metabolismo , Transdução de Sinais/efeitos dos fármacosRESUMO
BACKGROUND: Although it is evident that zoster vaccination reduces postherpetic neuralgia (PHN) risk by reducing herpes zoster (HZ) occurrence, it is less clear whether the vaccine protects against PHN among patients who develop HZ despite previous vaccination. METHODS: This cohort study included immunocompetent patients with HZ. The vaccinated cohort included 1155 individuals who were vaccinated against HZ at age ≥60 years and had an HZ episode after vaccination. Vaccinated patients were matched 1:1 by sex and age with unvaccinated patients. Trained medical residents reviewed the full medical record to determine the presence of HZ-related pain at 1, 2, 3, and 6 months after HZ diagnosis. The incidence of PHN was compared between vaccinated and unvaccinated -patients. RESULTS: Thirty vaccinated women (4.2%) experienced PHN, compared with 75 unvaccinated women (10.4%), with an adjusted relative risk of 0.41 (95% confidence interval, .26-.64). PHN occurred in 26 vaccinated men (6.0%) versus 25 unvaccinated men (5.8%), with an adjusted relative risk of 1.06 (.58-1.94). These associations did not differ significantly by age. CONCLUSIONS: Among persons experiencing HZ, prior HZ vaccination is associated with a lower risk of PHN in women but not in men. This sex-related difference may reflect differences in healthcare-seeking patterns and deserve further investigation.
Assuntos
Vacina contra Herpes Zoster/imunologia , Herpes Zoster/prevenção & controle , Herpesvirus Humano 3/imunologia , Neuralgia Pós-Herpética/prevenção & controle , Vacinação , Idoso , California/epidemiologia , Estudos de Coortes , Feminino , Herpes Zoster/epidemiologia , Herpes Zoster/imunologia , Humanos , Imunocompetência , Incidência , Masculino , Pessoa de Meia-Idade , Neuralgia Pós-Herpética/epidemiologia , Neuralgia Pós-Herpética/imunologia , RiscoRESUMO
PURPOSE: To compare fitting methods and sampling strategies, including the implementation of an optimized b-value selection for improved estimation of intravoxel incoherent motion (IVIM) parameters in breast cancer. METHODS: Fourteen patients (age, 48.4 ± 14.27 years) with cancerous lesions underwent 3 Tesla breast MRI examination for a HIPAA-compliant, institutional review board approved diffusion MR study. IVIM biomarkers were calculated using "free" versus "segmented" fitting for conventional or optimized (repetitions of key b-values) b-value selection. Monte Carlo simulations were performed over a range of IVIM parameters to evaluate methods of analysis. Relative bias values, relative error, and coefficients of variation (CV) were obtained for assessment of methods. Statistical paired t-tests were used for comparison of experimental mean values and errors from each fitting and sampling method. RESULTS: Comparison of the different analysis/sampling methods in simulations and experiments showed that the "segmented" analysis and the optimized method have higher precision and accuracy, in general, compared with "free" fitting of conventional sampling when considering all parameters. Regarding relative bias, IVIM parameters fp and Dt differed significantly between "segmented" and "free" fitting methods. CONCLUSION: IVIM analysis may improve using optimized selection and "segmented" analysis, potentially enabling better differentiation of breast cancer subtypes and monitoring of treatment.
Assuntos
Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Movimento (Física)RESUMO
Blood oxygen level-dependent (BOLD) MRI data of kidney, while indicative of tissue oxygenation level (Po2), is in fact influenced by multiple confounding factors, such as R2, perfusion, oxygen permeability, and hematocrit. We aim to explore the feasibility of extracting tissue Po2 from renal BOLD data. A method of two steps was proposed: first, a Monte Carlo simulation to estimate blood oxygen saturation (SHb) from BOLD signals, and second, an oxygen transit model to convert SHb to tissue Po2. The proposed method was calibrated and validated with 20 pigs (12 before and after furosemide injection) in which BOLD-derived tissue Po2 was compared with microprobe-measured values. The method was then applied to nine healthy human subjects (age: 25.7 ± 3.0 yr) in whom BOLD was performed before and after furosemide. For the 12 pigs before furosemide injection, the proposed model estimated renal tissue Po2 with errors of 2.3 ± 5.2 mmHg (5.8 ± 13.4%) in cortex and -0.1 ± 4.5 mmHg (1.7 ± 18.1%) in medulla, compared with microprobe measurements. After injection of furosemide, the estimation errors were 6.9 ± 3.9 mmHg (14.2 ± 8.4%) for cortex and 2.6 ± 4.0 mmHg (7.7 ± 11.5%) for medulla. In the human subjects, BOLD-derived medullary Po2 increased from 16.0 ± 4.9 mmHg (SHb: 31 ± 11%) at baseline to 26.2 ± 3.1 mmHg (SHb: 53 ± 6%) at 5 min after furosemide injection, while cortical Po2 did not change significantly at â¼58 mmHg (SHb: 92 ± 1%). Our proposed method, validated with a porcine model, appears promising for estimating tissue Po2 from renal BOLD MRI data in human subjects.
Assuntos
Córtex Renal/metabolismo , Medula Renal/metabolismo , Rim/irrigação sanguínea , Oxigênio/sangue , Adulto , Animais , Simulação por Computador , Feminino , Furosemida/farmacologia , Hemoglobinas/metabolismo , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Método de Monte Carlo , Pressão Parcial , SuínosRESUMO
Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury, and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics.
Assuntos
Nefropatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Nefrologia/tendências , Animais , HumanosRESUMO
Total amount of creatine (Cr) and phosphocreatine, or total creatine (tCr), may have a significant impact on the performance of skeletal muscles. In sports such as bodybuilding, it is popular to take Cr supplements to maintain tCr level. However, no study has explored the quantitative relationship between exercise intensity and the induced change in muscle's tCr. In this well-controlled study, straight-leg plantar flexion with specific load and duration was performed by 10 healthy subjects inside an MRI scanner, immediately followed by 1H MR spectroscopy (MRS) for measuring tCr concentration in gastrocnemius. For repeatability assessment, the experiment was repeated for each subject on two different days. Across all the subjects, baseline tCr was 46.6 ± 2.4 mM, ranging from 40.6 to 50.1 mM; with exercise, tCr significantly decreased by 10.9% ± 1.0% with 6-lb load and 21.0% ± 1.3% with 12-lb load (p < 0.0001). Between two different days, baseline tCr, percentage decrease induced by exercise with a 6-lb and 12-lb load differed by 2.2% ± 2.3%, 11.7% ± 6.0% and 4.9% ± 3.2%, respectively. In conclusion, the proposed protocol of controlled exercise stimulation and MRS acquisition can reproducibly monitor tCr level and its exercise-induced change in skeletal muscles. The measured tCr level is sensitive to exercise intensity, so can be used to quantitatively assess muscle performance or fatigue.