Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anticancer Drugs ; 33(10): 989-998, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36206129

RESUMO

Oovarian cancer is a common lethal gynecological malignancy with a high occurrence and dismal prognosis on account of its drug resistance. MicroRNAs (miRNAs) are widely involved in the chemotherapy resistance of tumors, including miR-30a-5p. Herein, we probed the functional role and molecular mechanism of miR-30a-5p in the chemoresistance of ovarian cancer. We enrolled 48 ovarian cancer patients in this study. Statistical analysis and a series of experiments including quantitative reverse transcription polymerase chain reaction, western blot, methyl thiazolyl tetrazolium assay, colony formation assay, flow cytometry analysis, Transwell assay, luciferase reporter assay, RNA pull-down assay and TOP/FOP flash assay were explored in the study. Animal experiments were performed to verify the role of miR-30a-5p in vivo . In our study, miR-30a-5p showed a prominently low level in ovarian cancer tissues and cells. Importantly, its expression in cisplatin-resistant cell lines was more downregulated than in cisplatin-sensitive ones. Additionally, miR-30a-5p overexpression inhibited proliferative, migratory and invasive abilities of ovarian cancer cells while enhancing cell apoptosis and improving cell sensitivity to cisplatin in ovarian cancer. Further, miR-30a-5p targeted to chromodomain helicase DNA binding protein 1 (CHD1) and inhibited the expression of CHD1 in ovarian cancer. Moreover, rescue experiments manifested that miR-30a-5p weakened cisplatin resistance and the cellular process of ovarian cancer by mediating CHD1. Besides, miR-30a-5p regulated CHD1 expression to suppress Wnt/ß-catenin signaling in ovarian cancer. The findings were verified by in vivo experiments. This article elucidated that miR-30a-5p/CHD1 axis inhibited the cellular process and enhanced cisplatin sensitivity of ovarian cancer cells through the Wnt/ß-catenin pathway, which may provide a useful direction for the targeted chemotherapy of ovarian cancer.


Assuntos
DNA Helicases , Proteínas de Ligação a DNA , MicroRNAs , Neoplasias Ovarianas , Animais , Feminino , Humanos , beta Catenina/metabolismo , Linhagem Celular Tumoral , Proliferação de Células , Cisplatino/farmacologia , Cisplatino/uso terapêutico , DNA Helicases/genética , DNA Helicases/metabolismo , Proteínas de Ligação a DNA/genética , Proteínas de Ligação a DNA/metabolismo , Regulação Neoplásica da Expressão Gênica , Luciferases/genética , Luciferases/metabolismo , MicroRNAs/genética , MicroRNAs/metabolismo , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/genética , Via de Sinalização Wnt
2.
Anesth Analg ; 135(2): 376-384, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35245225

RESUMO

BACKGROUND: Emergency front-of-neck access (FONA) is particularly challenging with impalpable neck anatomy. We compared 2 techniques that are based on a vertical midline neck incision, followed by finger dissection and then either a cannula or scalpel puncture to the cricothyroid membrane. METHODS: A manikin simulation scenario of impalpable neck anatomy and bleeding was created. Sixty-five anesthesiologists undergoing cricothyrotomy training performed scalpel-finger-cannula (SFC) and scalpel-finger-bougie (SFB) cricothyrotomy in random order. Primary outcomes were time to oxygen delivery and first-attempt success; data were analyzed using multilevel mixed-effects models. RESULTS: SFC was associated with a shorter time to oxygen delivery on univariate (median time difference, -61.5 s; 95% confidence interval [CI], -84.7 to -38.3; P < .001) and multivariable (mean time difference, -62.1 s; 95% CI, -83.2 to -41.0; P < .001) analyses. Higher first-attempt success was reported with SFC than SFB (47 of 65 [72.3%] vs 18 of 65 [27.7%]). Participants also had higher odds at achieving first-attempt success with SFC than SFB (odds ratio [OR], 10.7; 95% CI, 3.3-35.0; P < .001). Successful delivery of oxygen after the "can't intubate, can't oxygenate" (CICO) declaration within 3 attempts and 180 seconds was higher (84.6% vs 63.1%) and more likely with SFC (OR, 5.59; 95% CI, 1.7-18.9; P = .006). Analyzing successful cases only, SFC achieved a shorter time to oxygen delivery (mean time difference, -24.9 s; 95% CI, -37.8 to -12.0; P < .001), but a longer time to cuffed tube insertion (mean time difference, +56.0 s; 95% CI, 39.0-73.0; P < .001). After simulation training, most participants preferred SFC in patients with impalpable neck anatomy (75.3% vs 24.6%). CONCLUSIONS: In a manikin simulation of impalpable neck anatomy and bleeding, the SFC approach demonstrated superior performance in oxygen delivery and was also the preferred technique of the majority of study participants. Our study findings support the use of a cannula-based FONA technique for achieving oxygenation in a CICO situation, with the prerequisite that appropriate training and equipment are available.


Assuntos
Manuseio das Vias Aéreas , Cânula , Manuseio das Vias Aéreas/métodos , Cartilagem Cricoide/cirurgia , Estudos Cross-Over , Humanos , Intubação Intratraqueal , Manequins , Oxigênio
3.
J Clin Monit Comput ; 36(4): 1139-1145, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34347225

RESUMO

We compared the hyperangulated McGrath X-blade with the Macintosh-type CMAC videolaryngoscope through the use of manual in-line stabilization on patients. The primary hypothesis was that the McGrath X-blade has a similar first-attempt success rate as the CMAC videolaryngoscope. 210 patients of ASA physical status I to III, aged 21 to 80 years old, undergoing general anesthesia requiring tracheal intubation were prospectively recruited into this two-centre randomized controlled trial, from June 2016 to April 2019. Patients with history of or predicted difficult airway, pre-existing dental risks, BMI > 35 kg/m2, cervical spondylosis or myelopathy, aspiration risks, patients who declined to participate or lacked the mental capacity to give consent were excluded. Participants were intubated using either hyperangulated McGrath X-blade (MGX) or Macintosh-type CMAC (CM) videolaryngoscopy, with manual in-line stabilization. Primary outcome measured was first-attempt tracheal intubation success. Secondary outcomes included overall successful intubation within 2 attempts or 120 s, time to intubation, glottic view obtained and intubation-related complications. First-attempt success rates were 71.4% in the MGX group vs. 79.0% in the CM group (p = 0.26), with an absolute difference of -7.6% (95%CI -20%, 5.0%, p value = 0.26), but this trial was underpowered to detect a difference. Overall success was 91.4% (MGX) vs. 92.4% (CM) (p > 0.99). The Cormack & Lehane laryngeal grade was superior in the MGX group compared to CM group (Grade I: MGX 44%, CM 23%; Grade II: MGX 53%, CM 45%; Grade III: MGX 3%, CM 32%; p < 0.001). The median time to intubation using the MGX was longer than the CM [MGX 55.5 s (42.1-78.3), CM 43.8 s (38-55.3); p < 0.001]. Our study did not demonstrate a significant difference in efficacy between the McGrath X-blade and the CMAC videolaryngoscope. In patients with manual in-line stabilization, no anticipated airway difficulty and in the hands of experienced operators, the McGrath X-blade provided superior glottic views but conferred no advantage over the C-MAC, with a longer median time to intubation compared to the CMAC videolaryngoscope.Trial registration: Australian New Zealand Clinical Trial Registry (ACTRN12616000668404).


Assuntos
Laringoscópios , Laringoscopia , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Glote , Humanos , Intubação Intratraqueal , Pessoa de Meia-Idade , Gravação em Vídeo , Adulto Jovem
4.
J Clin Monit Comput ; 35(3): 443-447, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32274646

RESUMO

General anaesthesia is sometimes favoured over regional anaesthesia in ophthalmic surgery. The use of supraglottic airway (SGA) or laryngeal mask airway (LMA) as the primary airway device is increasing due to numerous advantages over tracheal intubation. Compared with 1st generation SGAs, 2nd generation SGAs have an added benefit of isolating the airway from the alimentary tract. However, the vertical profile of SGAs may encroach into the surgical field and hence interfere with surgery. We investigated the vertical projections of 1st generation SGAs (LMA Classic, Ambu AuraFlex) and commonly used 2nd generation SGAs in our institution (LMA ProSeal, LMA Supreme, LMA Protector, Ambu AuraGain and I-gel) in a manikin model. Each device was connected to a corrugated catheter mount or angled connector following insertion as per usual clinical practice in our institutions. Vertical projections of all devices were measured from the chin using a centimetre ruler. Securing of airway device to the chin with an adhesive tape was possible for the LMA Classic and Ambu AuraFlex with straight corrugated connector, whereas the stiffer 2nd generations SGAs required the addition of an angled connector or straight corrugated tubing to direct the airway tube caudally, away from the surgical field. The LMA ProSeal had the lowest vertical projection amongst the 2nd generation SGAs and may be the suitable choice for ophthalmic surgery. We also describe a novel technique of utilising a 1st generation SGA with placement of an orogastric tube, although with some reservations. This study has several limitations and transferability of our findings into clinical practice is questionable as the use of a manikin may not fully imitate the real condition of the patient. Our study is the first study comparing vertical projected height of different SGAs in manikin, but future studies should investigate the use of SGA in the clinical setting during ophthalmic surgery.


Assuntos
Máscaras Laríngeas , Manequins , Anestesia Geral , Face , Humanos , Intubação Intratraqueal
5.
Can J Respir Ther ; 53(2): 29-32, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-30996627

RESUMO

BACKGROUND: Cricothyrotomy can either be performed by an "open" cricothyrotomy technique, or by a needle (Seldinger) technique. Clinical uncertainty exists regarding which technique is more effective. We compared three different techniques for cricothyrotomy, performed by anesthesiologists on a manikin. METHODS: The techniques studied include an open surgical technique, the Melker Cricothyrotomy kit (Cook), and the Portex Cricothyroidotomy Kit (Smiths Medical). Participants were randomized to the order they performed each technique. Each procedure was videotaped and the time to first ventilation recorded. The participants completed a 10-point scale following the performance of all techniques to assess the subjective level of difficulty of each technique and to indicate which technique they would prefer in a real clinical CICO scenario. RESULTS: Mean time to ventilation was significantly faster with the surgical cricothyrotomy technique, when compared with both the Portex and Melker techniques (Mean difference: Portex-surgical = 18 s, 95% CI (1, 36) and Melker-surgical = 42 s, 95% CI (31, 54)). The Portex technique was significantly faster than the Melker technique (Melker-Portex = 24 s, 95% CI (11, 37)). Six of the 11 (55%) participants preferred the Melker procedure, four (36%) preferred the surgical procedure, and only one anesthesiologist (9%) preferred the Portex procedure. DISCUSSION: The surgical technique was faster than both the Portex and Melker techniques. The surgical technique was also more successful than the Melker technique. The preferred technique among the participants was the Melker technique, despite being the slowest, least successful, and rated most difficult by participants and observers. This suggests that although the surgical technique may not be preferred by many airway practitioners, it has been shown to be the most likely technique to achieve the primary goal of the procedure: establishing oxygenation and preventing death. IMPLICATION STATEMENT: This research examines three techniques for cricothyrotomy in the "Can't Intubate, Can't Oxygenate" scenario. Our data, as well as data from other studies, suggest that a practice shift towards a surgical technique, and away from needle based techniques, may be warranted.

7.
Can J Anaesth ; 62(5): 495-503, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25637060

RESUMO

PURPOSE: We sought to determine the rate of successful identification of the cricothyroid membrane by anesthesia residents and staff at a Canadian institution. METHODS: In this prospective study, healthy adult volunteer subjects were positioned supine with their necks placed in neutral position. There were 12 subjects, half of whom were non-obese (body mass index < 30.0 kg·m(2)) and half of whom were obese. There were equal numbers of male and female subjects in each of the obese and non-obese groups. Anesthesia staff and resident participants were allowed to palpate multiple subjects but with only one attempt per subject. For each subject, ultrasonography was used to identify the superior and inferior borders of the cricothyroid membrane, which were then marked with "invisible" ink that could be made visible with ultraviolet light. The midline was also marked with invisible ink. Identification of the cricothyroid membrane was considered correct if the mark was between the superior and inferior borders and within 0.5 cm of the midline. RESULTS: Altogether, 61 participants palpated 12 subjects, resulting in 186 identifications. The success rates for the subgroups were as follows: non-obese men 72% (95% confidence interval [CI] 59 to 85%); obese men 39% (95% CI 26 to 54%); non-obese women 24% (95% CI 12 to 36%); obese women 35% (95% CI 21 to 49%). CONCLUSION: Success rates for correct identification of the cricothyroid membrane were poor in this Canadian institution.


Assuntos
Anestesiologia/métodos , Cartilagem Cricoide/anatomia & histologia , Obesidade/metabolismo , Cartilagem Tireóidea/anatomia & histologia , Adulto , Canadá , Competência Clínica , Cartilagem Cricoide/diagnóstico por imagem , Feminino , Humanos , Internato e Residência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cartilagem Tireóidea/diagnóstico por imagem , Ultrassonografia , Adulto Jovem
8.
Sensors (Basel) ; 15(6): 13522-32, 2015 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-26066989

RESUMO

C2H2, C2H4, and C2H6 are important oil-dissolved gases in power transformers. Detection of the composition and content of oil-dissolved gases in transformers is very significant in the diagnosis and assessment of the state of transformer operations. The commonly used oil-gas analysis methods have many disadvantages, so this paper proposes a Ni-doped carbon nanotube (Ni-CNT) gas sensor to effectively detect oil-dissolved gases in a transformer. The gas-sensing properties of the sensor to C2H2, C2H4, and C2H6 were studied using the test device. Based on the density functional theory (DFT) the adsorption behaviors of the three gases on intrinsic carbon nanotubes (CNTs) and Ni-CNTs were calculated. The adsorption energy, charge transfer, and molecular frontier orbital of the adsorption system were also analyzed. Results showed that the sensitivity of the CNT sensor to the three kinds of gases was in the following order: C2H2 > C2H4 > C2H6. Moreover, the doped Ni improved the sensor response, and the sensor response and gas concentration have a good linear relationship.

10.
Food Chem ; 453: 139560, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-38761721

RESUMO

Baijiu authenticity has been a frequent problem driven by economic interests in recent years, so it is important to discriminate against baijiu with different origins. Herein, we proposed a simple and efficient esters-targeted colorimetric sensor array mediated by hydroxylamine hydrochloride. Esters undergo a nucleophilic addition reaction with hydroxylamine hydrochloride to form hydroxamic acid, which rapidly forms a purplish red ferric hydroxamate under FeCl3·6H2O. Bromophenol blue and rhodamine B enrich the color effects. The array detected 12 esters with a detection limit on the order of 10-5 of most esters and 16 mixed esters with R2 > 0.999 and recoveries close to 100%. Otherwise, for discriminating 34 strong-aroma baijius (SABs), the array has an accuracy of 98% according to the origin, and 95% according to the grades, with a response time of 1 min. This study provides a new strategy for authenticity determination and quality control of baijiu.


Assuntos
Colorimetria , Ésteres , Colorimetria/instrumentação , Colorimetria/métodos , Ésteres/química , Ésteres/análise , Bebidas Alcoólicas/análise , Odorantes/análise
11.
Food Chem ; 447: 138968, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38489877

RESUMO

Given the severe problem of Baijiu authenticity, it is essential to discriminate Baijiu from different origins quickly and effectively. As organic acids (OAs) are the most dominant taste-imparting substances in Baijiu, we proposed a simple, fast, and effective OAs-targeted colorimetric sensor array based on the colorimetric reaction of 4-aminophenol (AP)/4-amino-3-chlorophenol (ACP) under oxidation of Cu(NO3)2 for the rapid discrimination of origins of Baijiu with three main aroma types. Hydrogen ions ionized from OAs induced the protonation of the amino group, which blocked the colorimetric reaction, and the different levels of OAs in Baijiu enabled the array to discriminate different origins of Baijiu. The array was implemented to analyze 10 simple OAs and 16 mixed OAs and further for the discrimination of 42 Baijius with an accuracy of 98%. This method provided an efficient research strategy for a basis for rapid quality analysis of Baijiu.


Assuntos
Clorofenóis , Odorantes , Compostos Orgânicos Voláteis , Odorantes/análise , Colorimetria , Cromatografia Gasosa-Espectrometria de Massas/métodos , Compostos Orgânicos Voláteis/análise , Ácidos/análise
12.
Sensors (Basel) ; 13(11): 14764-76, 2013 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-24177728

RESUMO

The detection of partial discharge and analysis of SF6 gas components in gas-insulated switchgear (GIS) is important for the diagnosis and operating state assessment of power equipment. The use of a Pt-doped TiO2 nanotube arrays sensor for detecting sulfur hexafluoride (SF6) decomposition products is proposed in this paper. The electrochemical pulse deposition method is employed to prepare the sensor array. The sensor's response to the main characteristic gaseous decomposition products of SF6 is evaluated. The gas sensing characteristic curves of the Pt-doped TiO2 nanotube sensor and intrinsic TiO2 nanotube arrays sensor are compared. The mechanism of the sensitive response is discussed. Test results showed that the Pt-doped nanoparticles not only change the gas sensing selectivity of the TiO2 nanotube arrays sensor with respect to the main characteristic SF6 decomposition products, but also reduce the operating temperature of the sensor.


Assuntos
Análise em Microsséries/instrumentação , Nanotecnologia/instrumentação , Nanotubos/química , Platina/química , Hexafluoreto de Enxofre/análise , Titânio/química , Nanotecnologia/métodos , Hexafluoreto de Enxofre/química
13.
Singapore Med J ; 64(12): 728-731, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34628800

RESUMO

Introduction: Post-anaesthesia care unit (PACU) delirium affects 5%-45% of patients after surgery and is associated with postoperative delirium and increased mortality. Up to 40% of PACU delirium is preventable, but it remains under-recognised due to a lack of awareness of its diagnosis. The nursing delirium screening scale (Nu-DESC) has been validated for diagnosing PACU delirium, but is not routinely used locally. This study aimed to use Nu-DESC to establish the incidence and risk factors of PACU delirium in patients undergoing non-cardiac surgery in the surgical population. Methods: We conducted an audit of eligible patients undergoing major surgery in three public hospitals in Singapore over 1 week. Patients were assessed for delirium 30-60 min following their arrival in PACU using Nu-DESC, with a total score of ≥2 indicative of delirium. Results: A total of 478 patients were assessed. The overall incidence rate of PACU delirium was 18/478 (3.8%), and the incidence was 9/146 (6.2%) in patients aged > 65 years. Post-anaesthesia care unit delirium was more common in females, patients with malignancy and those who underwent longer operations. Logistic regression analysis showed that the use of bispectral index (P < 0.001) and the presence of malignancy (P < 0.001) were significantly associated with a higher incidence of PACU delirium. Conclusion: In this first local study, the incidence of PACU delirium was 3.8%, increasing to 6.2% in those aged > 65 years. Understanding these risk factors will form the basis for which protocols can be established to optimise resource management and prevent long-term morbidities and mortality in PACU delirium.


Assuntos
Anestesia , Delírio , Neoplasias , Feminino , Humanos , Delírio/diagnóstico , Delírio/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Singapura/epidemiologia , Estudos Prospectivos , Anestesia/efeitos adversos , Fatores de Risco
14.
Sensors (Basel) ; 12(3): 3302-13, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22737009

RESUMO

The detection of partial discharge through analysis of SF(6) gas components in gas-insulated switchgear, is significant for the diagnosis and assessment of the operating state of power equipment. The present study proposes the use of a TiO(2) nanotube array sensor for detecting the SF(6) decomposition product SO(2), and the application of the anodic oxidation method for the directional growth of highly ordered TiO(2) nanotube arrays. The sensor response of 10-50 ppm SO(2) gas is tested, and the sensitive response mechanism is discussed. The test results show that the TiO(2) nanotube sensor array has good response to SO(2) gas, and by ultraviolet radiation, the sensor can remove attached components very efficiently, shorten recovery time, reduce chemical poisoning, and prolong the life of the components.


Assuntos
Técnicas Eletroquímicas/métodos , Nanotubos/química , Dióxido de Enxofre/análise , Hexafluoreto de Enxofre/química , Titânio/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Gases/análise , Nanotubos/ultraestrutura , Oxirredução , Temperatura
15.
Materials (Basel) ; 15(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35591431

RESUMO

In this work, two isothermal sections of the Co-Ta-Si ternary system at 900 °C and 1100 °C are constructed in the whole composition range via phase equilibrium determination with the help of electron probe microanalysis (EPMA) and X-ray diffraction (XRD) techniques. Firstly, several reported ternary phases G (Co16Ta6Si7), G″ (Co4TaSi3), E (CoTaSi), L (Co3Ta2Si) and V (Co4Ta4Si7) are all re-confirmed again. The G″ phase is found to be a kind of high-temperature compound, which is unstable at less than 1100 °C. Additionally, the L phase with a large composition range (Co32-62Ta26-36Si10-30) crystallizes with a hexagonal crystal structure (space group: P63/mmc, C14), which is the same as that of the binary high-temperature λ1-Co2Ta phase. It can be reasonably speculated that the ternary L phase results from the stabilization toward low-temperature of the binary λ1-Co2Ta through adding Si. Secondly, the binary CoTa2 and SiTa2 phases are found to form a continuous solid solution phase (Co, Si)Ta2 with a body-centered tetragonal structure. Thirdly, the elemental Si shows a large solid solubility for Co-Ta binary compounds while the Ta and Co are hardly dissolved in Co-Si and Ta-Si binary phases, respectively.

16.
Materials (Basel) ; 15(19)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36234050

RESUMO

Fe additives may play an important role in the preparation of aluminum-based hydrolysis hydrogen powder, with high hydrogen yield, low cost, and good oxidation resistance. Therefore, it is necessary to ascertain the effect of Fe on the hydrogen production performance of Al-Bi-Sn composite powders. According to the calculated vertical cross-section of the Al-10Bi-7Sn-(0~6)Fe (wt.%) quasi-binary system, Al-10Bi-7Sn-xFe (x = 0, 0.5, 1.5, 3) wt.% composite powders for hydrogen production were prepared by the gas-atomization method. The results showed that the Al-10Bi-7Sn-1.5Fe (wt.%) powder exhibited an extremely fast hydrogen generation rate at 50 °C, which reached 1105 mL·g-1 in 27 min in distilled water, 1086 mL·g-1 in 15 min in 0.1 mol·L-1 NaCl solution, and 1086 mL·g-1 in 15 min in 0.1 mol·L-1 CaCl2 solution. In addition, the antioxidant properties of these powders were also investigated. The results showed that the hydrogen production performance of the Al-10Bi-7Sn-1.5Fe (wt.%) powder could retain 91% of its hydrogen production activity, even though the powder was exposed to 25 °C and 60 RH% for 72 h. The addition of Fe not only promoted the hydrogen generation rate of the Al-Bi-Sn composite powders, but also improved their oxidation resistance. The Al-10Bi-7Sn-1.5Fe (wt.%) composite powder shows great potential for mobile hydrogen source scenarios with rapid hydrogen production.

17.
Ann Acad Med Singap ; 51(2): 87-95, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35224604

RESUMO

INTRODUCTION: Post-anaesthesia care unit (PACU) delirium is a potentially preventable condition that results in a significant long-term effect. In a multicentre prospective cohort study, we investigate the incidence and risk factors of postoperative delirium in elderly patients undergoing major non-cardiac surgery. METHODS: Patients were consented and recruited from 4 major hospitals in Singapore. Research ethics approval was obtained. Patients older than 65 years undergoing non-cardiac surgery >2 hours were recruited. Baseline perioperative data were collected. Preoperative baseline cognition was obtained. Patients were assessed in the post-anaesthesia care unit for delirium 30-60 minutes after arrival using the Nursing Delirium Screening Scale (Nu-DESC). RESULTS: Ninety-eight patients completed the study. Eleven patients (11.2%) had postoperative delirium. Patients who had PACU delirium were older (74.6±3.2 versus 70.6±4.4 years, P=0.005). Univariate analysis showed those who had PACU delirium are more likely to be ASA 3 (63.6% vs 31.0%, P=0.019), had estimated glomerular filtration rate (eGFR) of >60mL/min/1.73m2 (36.4% vs 10.6%, P=0.013), higher HbA1C value (7.8±1.2 vs 6.6±0.9, P=0.011), raised random blood glucose (10.0±5.0mmol/L vs 6.5±2.4mmol/L, P=0.0066), and moderate-severe depression (18.2% vs 1.1%, P=0.033). They are more likely to stay longer in hospital (median 8 days [range 4-18] vs 4 days [range 2-8], P=0.049). Raised random blood glucose is independently associated with increased PACU delirium on multivariate analysis.


Assuntos
Anestesia , Delírio , Idoso , Período de Recuperação da Anestesia , Delírio/diagnóstico , Delírio/epidemiologia , Delírio/etiologia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Fatores de Risco
18.
A A Pract ; 15(4): e01436, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33783373

RESUMO

A patient with ankylosing spondylitis in a "can't intubate, can't oxygenate" situation was rescued with cannula cricothyrotomy and transtracheal jet oxygenation. The case revealed clinical and systematic weaknesses, leading to standardization and reorganization of our equipment. Prepackaged cannula cricothyrotomy sets were placed in standardized locations in the operating rooms in line with our institution's "cannula first" policy. Cognitive aids specific to emergency front-of-neck access (eFONA) were created and placed strategically with the eFONA equipment to prompt and guide operators during airway emergencies. The aids have also been incorporated into our training curriculum to encourage their use.


Assuntos
Emergências , Espondilite Anquilosante , Manuseio das Vias Aéreas , Cânula , Cognição , Humanos
19.
Anaesth Intensive Care ; 49(5): 395-403, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34550812

RESUMO

The Ambu® AuraGain™ (Ambu A/S, Ballerup, Denmark) is a newer phthalate-free, single-use supraglottic device with the advantage of a facility for tracheal intubation if necessary intraoperatively. We compared the oropharyngeal leak pressures and other performance variables between the AMBU AuraGain and the LMA® Supreme™ (Teleflex Medical, Athlone, Co. Westmeath, Ireland) in patients undergoing laparoscopic cholecystectomy and preperitoneoscopic inguinal herniorrhaphy with carbon dioxide insufflation under controlled ventilation. We recruited 120 American Society of Anesthesiologists physical status class I-3 patients between the ages of 21 and 80 years undergoing laparoscopic cholecystectomy or preperitoneoscopic inguinal herniorrhaphy into this single-centre randomised controlled trial. The primary outcome measure was the oropharyngeal leak pressures. Secondary outcomes included insertion parameters, ventilatory characteristics and postoperative sequelae. The AuraGain had slightly but significantly higher oropharyngeal leak pressures than the LMA Supreme (mean (standard deviation) 26.1 (6.9) versus 21.4 (4.7) cmH2O, P < 0.010). The overall insertion success of the AuraGain was comparable to the LMA Supreme (AuraGain 58/60 (96.7%); LMA Supreme 56/59 (94.9%), P = 0.679). The AuraGain was deemed more difficult to insert than the LMA Supreme, with 26/60 (43.3%) of AuraGain insertions graded easy versus 48/59 (81.4%) of LMA Supreme, P < 0.001. The mean time to insertion of the AuraGain was slightly longer than the LMA Supreme, 32.2 (10.5) versus 28.3 (12.0) s, P < 0.001. Intraoperative device failure occurred following carbon dioxide insufflation in one AuraGain and three LMA Supremes, bringing the perioperative success rate of AuraGain and LMA Supreme to 95% and 89.8%, respectively, P = 0.322. No cases of regurgitation and aspiration occurred, and minor postoperative complications were similar. The AuraGain exhibited higher oropharyngeal leak pressures than the LMA Supreme, but was slightly more difficult to insert. The higher oropharyngeal leak pressures suggest that ventilation might be less affected by high peak inspiratory pressures when using the AuraGain than the LMA Supreme.


Assuntos
Laparoscopia , Máscaras Laríngeas , Adulto , Idoso , Idoso de 80 Anos ou mais , Manuseio das Vias Aéreas , Humanos , Intubação Intratraqueal , Máscaras Laríngeas/efeitos adversos , Pessoa de Meia-Idade , Pressão , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA