Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Oral Rehabil ; 51(5): 795-804, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38131438

RESUMO

BACKGROUND: Unbalanced alterations of temporomandibular joint morphology were associated with unilaterally masticatory habits. OBJECTIVE: This study aimed to investigate the effect of unilateral mastication on the remodelling of the temporomandibular joint using dynamic joint space. METHODS: Twelve volunteers with non-maxillofacial deformity and healthy temporomandibular joints were recruited. The 3D models of the mandible and the maxilla were reconstructed according to computed tomography. The subjects were asked to masticate French fries and peanuts unilaterally, which was recorded by a 3D motion capture system. The dynamic joint space during unilateral mastication was analysed. RESULTS: During early closure, the joint space reduction on the non-masticatory side was significantly greater than on the masticatory side (p < .05). During later closure, the joint space reduction on the non-masticatory side was significantly lower than that on the masticatory side (p < .05). The difference in joint space reduction between both sides was greater than the French fries while masticating the peanuts. CONCLUSIONS: Unilateral mastication resulted in a different major pressure area on the bilateral TMJs. Therefore, unilateral mastication might be an essential factor in the bilateral asymmetrical remodelling of the TMJ.


Assuntos
Mastigação , Transtornos da Articulação Temporomandibular , Humanos , Articulação Temporomandibular/diagnóstico por imagem , Mandíbula , Maxila
2.
J Vasc Interv Radiol ; 33(4): 375-383.e5, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34952197

RESUMO

PURPOSE: To assess the predictive value of geometric parameters for type Ia endoleak (T1AEL) after endovascular abdominal aortic aneurysm repair and to determine the range of optimal oversizing ratio (OSR) in patients with an elliptical cross-section of the aneurysm neck. MATERIALS AND METHODS: A propensity score-matched case-control study was conducted. Case patients were those who were diagnosed with T1AEL and control patients were those who did not have T1AEL after endovascular aneurysm repair during the period from 2012 to 2018. Geometric and oversizing parameters were compared based on both 2-dimensional (2D) and 3-dimensional measurements. Net reclassification improvement was used to measure the prediction increment of an elliptical model (major axis OSR, neck length, and severe neck angulation) compared with that of the conventional model (OSR 2D, neck length, and severe neck angulation). RESULTS: Nineteen case patients and 111 control patients were included. The median OSR 2D of patients with T1AEL was 17% (interquartile range, 15%-22%), but the median major axis OSR was only 7% (interquartile range, 5%-12%). For the geometric parameters, axis difference had the highest area under the curve (AUC) (0.74; 95% CI, 0.63-0.84) for predicting T1AEL. For the elliptical oversizing parameters, the major axis OSR had an AUC of 0.89 (95% CI, 0.78-0.97), with a cutoff value of 13%. The elliptical model had a higher discriminating ability for T1AEL than the conventional model (AUC 0.91 vs 0.86, respectively; P = .045), with an improved reclassification ability (net reclassification improvement, 27.93%; 95% CI, 19.22%-36.64%; P < .0001). CONCLUSIONS: Elliptical aneurysm neck cross-section, assessed by the difference between axis dimensions in the plane orthogonal to the centerline, was associated with an increased risk of T1AEL. The prescription of major axis oversizing of at least 13% can significantly reduce the risk of T1AEL formation in patients with an elliptical aneurysm neck.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Estudos de Casos e Controles , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
3.
Eur J Vasc Endovasc Surg ; 64(2-3): 155-164, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35605907

RESUMO

OBJECTIVES: This study aimed to derive a novel classification of blood flow pattern in abdominal aortic aneurysms (AAA) based on computational fluid dynamics (CFDs), and to determine the predictive value of flow patterns in AAA rupture. METHODS: This was an age and sex matched case control study. Cases were identified as patients who underwent emergency endovascular or open repair due to ruptured or AAA at risk of impending rupture. Controls were age and sex matched with patients with an AAA who were asymptomatic and had a confirmed unruptured AAA from computed tomography angiography images from the same period. Classification of blood flow pattern (type I: non-helical main flow channel with multiple vortices; type II: non-helical main flow channel with single vortices; and type III, helical main flow channel with helical vortices) and haemodynamic parameters (areas of low wall shear stress [AlowWSS], aneurysm pressure drop [Δ pressure], etc) were derived from CFD analyses. Multivariable regression was used to determine independent AAA rupture risk factors. The incremental discriminant and reclassification abilities for AAA rupture were compared among different models. RESULTS: Fifty-three ruptured and 53 intact AAA patients were included. Ruptured AAA showed a higher prevalence of type III flow pattern than intact AAA (60.4% vs. 15.1%; p < .001). Type III flow pattern was associated with a significantly increased risk of aneurysm rupture (odds ratio 10.22, 95% confidence interval 3.43 - 30.49). Among all predicting models, the combination of AAA diameter, haemodynamic parameters (AlowWSS or Δ pressure), and flow pattern showed highest discriminant abilities in both the overall population (c-index = 0.862) and subgroup patients with AAAs < 55 mm (c-index = 0.972). Compared with AAA diameter, adding the flow pattern could significantly improve the reclassification abilities in both the overall population (net reclassification index [NRI] = 0.321; p < .001) and the subgroup of AAAs < 55 mm (NRI = 0.732; p < .001). CONCLUSION: Type III flow pattern was associated with a significantly increased risk of AAA rupture. The integration of blood flow pattern may improve the identification of high risk aneurysms in both overall population and in those with AAAs < 55 mm.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Humanos , Aneurisma da Aorta Abdominal/complicações , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Estudos de Casos e Controles , Hidrodinâmica , Hemodinâmica , Fatores de Risco
4.
Ann Vasc Surg ; 79: 298-309, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34648850

RESUMO

BACKGROUND: Hemodynamic effects on the retrograde visceral reconstruction (RVR) for thoracoabdominal aortic aneurysms treatment by anastomotic angle remains unclear. This study aims to qualitatively and quantitatively investigate the effects of different anastomotic angles on hemodynamics and patency. METHODS: Three RVR models with 45°, 60° and 90° anastomotic angles were reconstructed respectively by manipulating apostoperative patient-specific model. The manipulated models of the RVRs were numerically simulated and analyzed in terms of hemodynamics including theinstant and cumulative patency, flow pattern and indicators based on wall shear stress (WSS). RESULTS: Although a smaller anastomotic angle may decrease the patency rate of common iliac arteries, it can improve the visceral perfusion during a cardiac cycle. More importantly, RVR with the smallest anastomotic angle experienced a minimal low time-averaged wall shear stress, high oscillatory shear index and relative residence time in the anastomosis region, whereas the largest anastomotic angle can introduce more unfavorable WSS in the graft trunk. Furthermore, a spiral flow pattern was observed in the proximal graft trunk of all three models, where no high-risk shear distribution was detected in this region. CONCLUSION: A smaller anastomotic angle may have more benefits of hemodynamic environment in RVR, especially the WSS distribution and flow pattern in the graft trunk. We may also suggest that additional stents or an extended cuff for the graft can be used to induce spiral flow intentionally, which can further improve local hemodynamic environment and long-term prognosis.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Hemodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Grau de Desobstrução Vascular , Anastomose Cirúrgica , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Estresse Mecânico , Resultado do Tratamento
5.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 39(4): 645-650, 2022 Aug 25.
Artigo em Zh | MEDLINE | ID: mdl-36008327

RESUMO

This study aims to investigate whether displacement force on stents can accurately represents the displacement of the stent after endovascular aneurysm repair (EVAR) by comparing the measured stent displacement with the displacement forces calculated by computational fluid dynamics (CFD). And the effect of cross-limb and parallel-limb EVAR on stent displacements is further studied. Based on our objective, in this study, ten cross-limb EVAR patients and ten parallel-limb EVAR patients in West China Hospital of Sichuan University were enrolled. Patient-specific models were first reconstructed based on the computed tomography angiography images, then the stent displacements were measured, and the displacement forces acting on the stents were calculated by CFD. Finally, the cosα value of the angle between the displacement force and the displacement vector was used to analyze the matching degree between the displacement and the displacement force. The results showed that the displacement forces on cross-limb stents and parallel-limb stents were (2.67 ± 2.14) N and (1.36 ± 0.48) N, respectively. Displacements of stent gravity center, stent displacements relative to vessel, and vessel displacements of cross-limb and parallel-limb stents were (4.43 ± 2.81) mm and (6.39 ± 2.62) mm, (0.88 ± 0.67) mm and (1.11 ± 0.71) mm, (3.55 ± 2.88) mm and (5.28 ± 2.52) mm, respectively. The mean cosα for cross-limb and parallel-limb stents were 0.02 ± 0.66 and - 0.10 ± 0.73, respectively. This study indicates that the displacement force on the stent can't accurately represent the displacement of the stent after EVAR. In addition, the cross-limb EVAR is probably safer and more stable than the parallel-limb EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Humanos , Desenho de Prótese , Estudos Retrospectivos , Stents , Resultado do Tratamento
6.
J Biomech Eng ; 142(12)2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32507897

RESUMO

The purpose of this study was to investigate how sagittal split ramus osteotomy (SSRO) and Le Fort 1 osteotomy affected the stress distribution of the temporomandibular joint (TMJ) during an anterior teeth bite using the three-dimensional (3D) finite element (FE) method. Fourteen orthognathic surgery patients were examined with mandibular prognathism, facial asymmetry, and mandibular retraction. They underwent Le Fort 1 osteotomy in conjunction with SSRO. In addition, ten asymptomatic subjects were recruited as the control group. The 3D models of the mandible, disc, and maxilla were reconstructed according to cone-beam computed tomography (CBCT). Contact was used to simulate the interaction of the disc-condyle, disc-temporal bone, and upper-lower dentition. Muscle forces and boundary conditions corresponding to the anterior occlusions were applied on the models. The stresses on the articular disc and condyle in the pre-operative group were significantly higher than normal. The contact stress and minimum principal stress in TMJ for patients with temporomandibular disorder (TMD) were abnormally higher. The peak stresses of the TMJ of the patients under anterior occlusions decreased after bimaxillary osteotomy. No postoperative TMD symptoms were found. Maxillofacial deformity led to excessive stress on the TMJ. Bimaxillary osteotomy can partially improve the stress distributions of the TMJ and relieve the symptoms of TMD.


Assuntos
Osteotomia Maxilar , Articulação Temporomandibular , Adolescente , Adulto , Humanos , Mandíbula , Adulto Jovem
7.
J Biomech Eng ; 142(9)2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32110795

RESUMO

Central venous catheter (CVC) related thrombosis is a major cause of CVC dysfunction in patients under hemodialysis. The aim of our study was to investigate the impact of CVC insertion on hemodynamics in the central veins and to examine the changes in hemodynamic environments that may be related to thrombus formation due to the implantation of CVC. Patient-specific models of the central veins with and without CVC were reconstructed based on computed tomography images. Flow patterns in the veins were numerically simulated to obtain hemodynamic parameters such as time-averaged wall shear stress (TAWSS), oscillating shear index (OSI), relative residence time (RRT), and normalized transverse wall shear stress (transWSS) under pulsatile flow. The non-Newtonian effects of blood flow were also analyzed using the Casson model. The insertion of CVC caused significant changes in the hemodynamic environment in the central veins. A greater disturbance and increase of velocity were observed in the central veins after the insertion of CVC. As a result, TAWSS and transWSS were markedly increased, but most parts of OSI and RRT decreased. Newtonian assumption of blood flow would overestimate the increase in TAWSS after CVC insertion. High wall shear stress (WSS) and flow disturbance, especially the multidirectionality of the flow, induced by the CVC may be a key factor in initiating thrombosis after CVC insertion. Accordingly, approaches to decrease the flow disturbance during CVC insertion may help restrain the occurrence of thrombosis. More case studies with pre-operative and postoperative modeling and clinical follow-up need to be performed to verify these findings. Non-Newtonian blood flow assumption is recommended in computational fluid dynamics (CFD) simulations of veins with CVCs.


Assuntos
Hemodinâmica , Hidrodinâmica , Modelos Cardiovasculares , Estresse Mecânico , Veias
8.
Ann Vasc Surg ; 59: 308.e1-308.e8, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31075464

RESUMO

BACKGROUND: Pancreaticoduodenal artery aneurysms (PDAAs) with occlusion of the superior mesenteric artery (SMA) are extremely rare. In the present study, we used computational fluid dynamics (CFD) to analyze the hemodynamics of a patient-specific PDAA with occlusion of the SMA preoperatively and then decide the treatment strategy in terms of the potential postoperative hemodynamics. METHODS: A 3D model of a 69-old-year female with PDAA was reconstructed based on CT images. The virtual postoperative models of the aneurysmectomy with or without revascularization were numerically simulated in terms of hemodynamics including the flow field and wall shear stress (WSS). RESULTS: Aneurysmectomy with revascularization would result in the original aneurysm site experiencing abnormally high WSS and pressure, which may possibly lead to the recurrence of PDAA. However, aneurysmectomy without revascularization would lead to stagnant flow in the blocked posterior-inferior pancreaticoduodenal artery (PIPDA). As a result, the PIPDA may soon be completely occluded after surgery and the SMA perfusion would be guaranteed. Finally, aneurysmectomy without revascularization was performed in this patient. The postoperative six-month computed tomography angiography result finely matched to the preoperative CFD simulation result. CONCLUSIONS: This study gained insights into hemodynamics of PDAA. In addition, it demonstrated that utilization of CFD analysis also possibly helps assist the operation strategies for vascular diseases.


Assuntos
Aneurisma/cirurgia , Duodeno/irrigação sanguínea , Hemodinâmica , Artéria Mesentérica Superior/cirurgia , Oclusão Vascular Mesentérica/cirurgia , Pâncreas/irrigação sanguínea , Modelagem Computacional Específica para o Paciente , Circulação Esplâncnica , Idoso , Aneurisma/complicações , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/fisiopatologia , Oclusão Vascular Mesentérica/complicações , Oclusão Vascular Mesentérica/diagnóstico por imagem , Oclusão Vascular Mesentérica/fisiopatologia , Modelos Cardiovasculares , Valor Preditivo dos Testes , Resultado do Tratamento , Grau de Desobstrução Vascular
9.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 35(6): 870-876, 2018 12 25.
Artigo em Zh | MEDLINE | ID: mdl-30583311

RESUMO

This paper aims to explore the feasibility of building a finite element model of left atrial diverticulum (LAD) using reverse engineering software based on computed tomography (CT) images. The study was based on a three-dimensional cardiac CT images of a atrial fibrillation patient with LAD. The left atrium and LAD anatomical features were accurately reproduced by using Geomagic Studio 12 and Mimics 15 reverse engineering software. In addition, one left atrial model with LAD and one without LAD were created with ANSYS finite element analysis software, and the validity of the two models were verified. The results show that it is feasible to establish the LAD finite element model based on cardiac three-dimensional CT images using reverse engineering software. The results of this paper will lay a theoretical foundation for further hemodynamic analysis of LAD.

10.
J Biomech ; 167: 112086, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38615481

RESUMO

Accurate assessment of portacaval pressure gradient (PCG) in patients with portal hypertension (PH) is of great significance both for diagnosis and treatment. This study aims to develop a noninvasive method for assessing PCG in PH patients and evaluate its accuracy and effectiveness. This study recruited 37 PH patients treated with transjugular intrahepatic portosystemic shunt (TIPS). computed tomography angiography was used to create three dimension (3D) models of each patient before and after TIPS. Doppler ultrasound examinations were conducted to obtain the patient's portal vein flow (or splenic vein and superior mesenteric vein). Using computational fluid dynamics (CFD) simulation, the patient's pre-TIPS and post-TIPS PCG was determined by the 3D models and ultrasound measurements. The accuracy of these noninvasive results was then compared to clinical invasive measurements. The results showed a strong linear correlation between the PCG simulated by CFD and the clinical invasive measurements both before and after TIPS (R2 = 0.998, P < 0.001 and R2 = 0.959, P < 0.001). The evaluation accuracy of this noninvasive method reached 94 %, and the influence of ultrasound result errors on the numerical accuracy was found to be marginal if the error was less than 20 %. Furthermore, the information about the hemodynamic environment in the portal system was obtained by this numerical method. Spiral flow patterns were observed in the portal vein of some patients. In a conclusion, this study proposes a noninvasive numerical method for assessing PCG in PH patients before and after TIPS. This method can assist doctors in accurately diagnosing patients and selecting appropriate treatment plans. Additionally, it can be used to further investigate potential biomechanical causes of complications related to TIPS in the future.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Hidrodinâmica , Veia Porta/diagnóstico por imagem , Hipertensão Portal/diagnóstico por imagem , Hemodinâmica
11.
J Biomech ; 163: 111937, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38246010

RESUMO

Transjugular intrahepatic portosystemic shunt (TIPS) relieves cirrhotic complications by reducing portacaval pressure gradient (PCG), but it lacks precision in achieving a targeted post-TIPS PCG simply through diameter adjustment of equal diameter stents. This study aimed to present a controlled-expansion, streamlined, and covered tapered stent, and examined its effects on pressure reduction compared with equal- diameter stents. Twenty-four patients who underwent standardized 8-mm stent TIPS implantation at West China Hospital from December 2017 to February 2021 were included in the current study. Virtual equal-diameter stent graft with different diameter and streamlined tapered stents were created in the post-TIPS 3-dimentional models reconstructed based on computed tomography angiography data. The numerical simulation showed that only two patients achieved targeted post-TIPS PCG consistent with the clinical invasive measurement. When 6-mm and 10-mm equal-diameter stents were employed, simulated post-TIPS PCGs for most patients remained outside the safe range, and recirculating flow was observed at the stent-portal vein anastomosis. In contrast, the use of the new streamlined taper stent resulted in post-TIPS PCGs within the 10-12 mmHg range for 17 out of 24 patients, with no recirculating flow observed at the anastomotic sites. In conclusion, the streamlined tapered stent could pose an effective solution to the problem that the big jump depressurization between two different equal-diameter stents and it would improve the hemodynamics in the region near the PV-stent anchorage. Therefore, the streamlined tapered stent may present a superior alternative for TIPS procedure.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Resultado do Tratamento , Stents , Veia Porta
12.
Comput Methods Biomech Biomed Engin ; 26(2): 209-221, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35414317

RESUMO

The accuracy of the Newtonian model used in retrograde visceral revascularization (RVR) of hybrid surgery for thoracoabdominal aortic aneurysm (TAAA) hemodynamic simulation remains unclear. Noting that an appropriate blood viscosity model is a significant factor to capture hemodynamic changes in numerical studies. Therefore, both Newtonian and non-Newtonian blood viscosity models were adopted in this study to investigate the importance of hemodynamics when non-Newtonian blood property was accounted for in a patient-specific RVR simulation. The results revealed that disturbed flow and unfavorable WSS distribution can be observed in the anastomosis region under both blood viscosity models due to the retrograde flow pattern in the RVR model. However, although the non-Newtonian blood model has negligible effect on flow pattern and pressure drop, there were of significance quantitative and qualitative difference of local normalized helicity and wall shear stress distribution under pulsatile flow condition. In particular, the unfavorable WSS indicators distribution was better matched with a patient-specific follow-up report when non-Newtonian blood viscosity was accounted for. To conclude, the use of a Newtonian blood model is a reasonable approximation to obtain the general features of the flow field under steady flow condition. However, to study the hemodynamic parameters within retrograde flow under pulsatile flow condition, a non-Newtonian model may be more appropriate.


Assuntos
Aneurisma da Aorta Toracoabdominal , Humanos , Modelos Cardiovasculares , Hemodinâmica , Fluxo Pulsátil , Simulação por Computador , Estresse Mecânico , Velocidade do Fluxo Sanguíneo
13.
Bioengineering (Basel) ; 10(2)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36829632

RESUMO

OBJECTIVES: Post-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting inter-data associations. Herein, we propose a method based on the stepwise combination of basic, non-divisible data sets to quickly obtain morphological parameters with high accuracy. METHODS: We performed the 3D reconstruction of 109 post-operative follow-up CT image data from 26 patients using mimics software. By extracting the spatial locations of the basic morphological observation points on the stent, we defined a basic and non-reducible set of observation points. Further, we implemented a fully automatic stent segmentation and an observation point extraction algorithm. We analyzed the stability and accuracy of the algorithms on a test set containing 8 cases and 408 points. Based on this dataset, we calculated three morphological parameters of different complexity for the different spatial structural features exhibited by the stent. Finally, we compared the two measurement schemes in four aspects: data variability, data stability, statistical process complexity and algorithmic error. RESULTS: The statistical results of the two methods on two low-complexity morphological parameters (spatial position of stent end and vascular stent end-slip volume) show good agreement (n = 26, P1, P2 < 0.001, r1 = 0.992, r2 = 0.988). The statistics of the proposed method for the morphological parameters of medium complexity (proximal support ring feature diameter and distal support ring feature diameter) avoid the errors caused by manual extraction, and the magnitude of this correction to the traditional method does not exceed 4 mm with an average correction of 1.38 mm. Meanwhile, our proposed automatic observation point extraction method has only 2.2% error rate on the test set, and the average spatial distance from the manually marked observation points is 0.73 mm. Thus, the proposed method is able to rapidly and accurately measure the stent circumferential deflection angle, which is highly complex and cannot be measured using traditional methods. CONCLUSIONS: The proposed method can significantly reduce the statistical observation time and information processing cost compared to the traditional morphological observation methods. Moreover, when new morphological parameters are required, one can quickly and accurately obtain the target parameters by new "combinatorial functions." Iterative modification of the data set itself is avoided.

14.
Med Phys ; 50(10): 6614-6623, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37227701

RESUMO

BACKGROUND: It was still controversial that whether the increase of splenic vein (SV) diameter increased the risk of portal vein thrombosis (PVT), which was a severe disease with high mortality, in the clinic. PURPOSES: This study, using computational fluid dynamics method, aimed to investigate how the increase of SV diameter affects the portal vein hemodynamics under different anatomical and geometric features of the portal venous system, thus how it induced to PVT. METHODS: The ideal models of the portal system, including different anatomical structures according to the location of left gastric vein (LGV) and inferior mesenteric vein (IMV), and different geometric morphological parameters models were established to carry out numerical simulation in this study. In addition, the morphological parameters of real patients were measured to verify the numerical simulation results. RESULTS: First, the wall shear stress (WSS) and helicity intensity, which were closely related to the occurrence of thrombosis, gradually decreased with the increase of SV diameter in all models. However, the degree of decrease was bigger in following models: (1) the models with LGV and IMV linking to SV compared with them linking to PV; (2) the models with big angle of PV and SV compared with small angle. In addition, the morbidity of PVT was higher when LGV and IMV linked to SV rather than them linked to PV in the real patients. Moreover, the angle of PV and SV was also different between PVT and non-PVT patients (125.53° ± 16.90° vs. 115.03° ± 16.10°, p = 0.01). CONCLUSION: Whether the increase of SV diameter will result in PVT is depended on the anatomical structure of portal system and the angle between PV and SV, this is also the reason leading to the clinical controversy that the increase of SV diameter is the risk factor of PVT.


Assuntos
Trombose , Trombose Venosa , Humanos , Veia Porta/diagnóstico por imagem , Veia Porta/patologia , Veia Esplênica/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Cirrose Hepática , Trombose/diagnóstico por imagem , Trombose/complicações , Estudos Retrospectivos
15.
Comput Methods Programs Biomed ; 230: 107331, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36621070

RESUMO

BACKGROUND AND OBJECTIVE: The occurrence of acute type B aortic dissection (TBAD) remained unclear. This study aimed to investigate the association between flow features and hemodynamic parameters in aortas that demonstrated the risk of TBAD occurrence. METHODS: The geometries of 15 hyperacute TBAD and 12 control patients (with healthy aorta) were reconstructed from computed tomography angiography images. Pre-TBAD models were then obtained by eliminating the dissection flaps. Flow features and hemodynamic parameters, including wall shear stress-related parameters and helicities, were compared between pre-TBAD and control models using computational fluid dynamics. RESULTS: There were no significant differences in baseline characteristics and anatomical parameters between the two groups. Significant contralateral helical blood flow was present in the healthy thoracic aorta, while almost no helical flow was observed in the pre-TBAD group. In addition, the mean normal transverse wall shear stress (NtransWSS) was significantly higher in the pre-TBAD group (aortic arch 0.49±0.09 vs. 0.40±0.05, P = 0.04; descending aorta: 0.46±0.05 vs. 0.33±0.02, P<0.01). Moreover, a significantly negative correlation was found between helicity and NtransWSS in the descending aorta. Moreover, the location of primary tears in 12 pre-TABD subjects matched well with regions of high NtransWSS. CONCLUSIONS: Loss of helical flow in the aortic arch and descending aorta may be a major flow feature in patients with underlying TBAD, resulting in increased flow disturbance and wall lesions.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Aorta , Hemodinâmica , Resultado do Tratamento , Estudos Retrospectivos
16.
Front Physiol ; 14: 1065805, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36818449

RESUMO

Background: Predicting the development of sporadic type B aortic dissection (TBAD) always remains a difficult issue. This study aimed to identify high-risk patients for development of TBAD based on morphological parameters. Methods: This propensity-score-matched case-control study collected and reconstructed the computed tomography angiography of acute TBAD patients and hospital-based control participants without aortic dissection from January 2013 to December 2016. Multivariate regression analysis was used to calculate the adjusted odds ratio (aOR) and 95% confidence interval (CI). Discriminant and reclassification abilities were compared between our model and a previously established model. Results: Our study included 76 acute TBAD patients and 79 control patients (48 cases and 48 controls after propensity-score matching). The degree of question mark (aOR 1.07, 95% CI 1.04-1.11), brachiocephalic trunk diameter (aOR 1.49, 95% CI 1.20-1.85), brachiocephalic trunk angle (aOR 0.97, 95% CI 0.94-0.99), aortic root diameter (aOR 1.31, 95% CI 1.15-1.48), and aortic width (aOR 1.12, 95% CI 1.07-1.17) were associated with a significantly increased risk of TBAD formation. Similar findings were observed in the propensity-score matching and sensitivity analysis only including hyperacute TBAD patients. A novel prediction model was established based on the aforementioned parameters. The new model showed significantly improved discriminant ability compared with the previously established model (c-index 0.78 [95% CI 0.71-0.85] vs. 0.67 [95% CI 0.58-0.75], p = .03), driven by increased reclassification ability in identifying TBAD patients (NRI for events 0.16, 95% CI 0.02-0.30, p = .02). Conclusion: Morphological predictors, including the degree of question mark, aortic width, aortic root diameter, brachiocephalic trunk angle, and brachiocephalic trunk diameter, may be used to identify patients at high risk of TBAD.

17.
J Stomatol Oral Maxillofac Surg ; 124(1S): 101285, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36087916

RESUMO

BACKGROUND: Temporomandibular disorder (TMD) symptoms were found to be common in the patients with maxillofacial deformities. The mandibular structure was in relation with the stress within temporomandibular joint (TMJ). However, the current studies on the TMJ stresses in the patients with different maxillofacial deformities are not comprehensive enough. PURPOSE: The aim of this study was to investigate the compression and morphology of the TMJ in the patients with different maxillofacial deformities under central occlusion. METHODS: 24 patients and 10 asymptomatic individuals were included in this study and divided into patient groups and control group. The 3D models were reconstructed. Muscle forces and boundary conditions corresponding to the central occlusion were applied. Nine morphological parameters of mandible were evaluated. RESULTS: The minimum principal stresses in the articular disc and condyle were significantly greater than those of the control group (P<0.05). For the articular disc, the compression on the non-deviation side was greater than those on the deviation side in patients with asymmetrical mandibles. There was difference between both sides in the mandibular prognathism and retrusion groups. The joint space of patients was significantly lower than that of the control group (P<0.05). CONCLUSIONS: Maxillofacial deformities might change the condylar position within the articular fossa, which decreased the joint space and increased the compression within TMJ. The patients with asymmetry mandible suffered greater pressure within TMJ on the non-deviation side. The bilaterally over-developed and under-developed mandible in patients might also increase the compression within TMJ.


Assuntos
Luxações Articulares , Transtornos da Articulação Temporomandibular , Humanos , Articulação Temporomandibular , Mandíbula , Transtornos da Articulação Temporomandibular/complicações , Transtornos da Articulação Temporomandibular/diagnóstico , Osso Temporal
18.
J Biomech ; 143: 111303, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36126502

RESUMO

Transjugular intrahepatic portosystemic shunt (TIPS) is an effective treatment for portal hypertension (PH). The current study aimed to investigate the effect of stent position on post-TIPS hemodynamic performance using computational fluid dynamics. Patient-specific pre- and post-TIPS models were reconstructed from CT images of two patients, then virtual TIPS models were created by shifting the portal vein (PV) entry site of the stent. Although there were marginal differences the effects of left-sided and right-sided TIPS on post-TIPS portal pressure and shunting flow, right-sided TIPS resulted in a greater proportion of superior mesenteric vein (SMV) flow diverting to stents compared to that for left-sided TIPS. The results also demonstrated that the nearer the entry site of stent to the portal venous bifurcation, the greater and more stable the shunting blood flow. These results suggest that the entry site of the stent should be as close to the portal vein bifurcation as possible during TIPS. TIPS on the right branch of the portal vein may be more likely to result in post-TIPS hepatic encephalopathy than that on the left branch.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Hemodinâmica/fisiologia , Humanos , Hipertensão Portal/cirurgia , Veia Porta/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Estudos Retrospectivos , Stents , Resultado do Tratamento
19.
Bioengineering (Basel) ; 9(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36134992

RESUMO

Purpose: Currently, the displacement force of stent grafts is generally obtained using computational fluid dynamics (CFD), which requires professional CFD knowledge to perform the correct simulation. This study proposes a fast, simple, and clinician-friendly approach to calculating the patient-specific displacement force after endovascular aneurysm repair (EVAR). Methods: Twenty patient-specific post-EVAR computed tomography angiography images were used to reconstruct the patient-specific three-dimensional models, then the displacement forces were calculated using CFD and the proposed approaches, respectively, and their numerical differences were compared and analyzed. Results: Based on the derivation and simplification of the momentum theorem, the patient-specific displacement forces were obtained using the information of the patient-specific pressure, cross-sectional area, and angulation of the two stent graft ends, and the average relative error was no greater than 1.37% when compared to the displacement forces calculated by CFD. In addition, the linear regression analysis also showed good agreement between the displacement force values calculated by the new approach and CFD (R = 0.999). Conclusions: The proposed approach can quickly and accurately calculate the patient-specific displacement force on a stent graft and can therefore help clinicians quickly evaluate the post-EVAR displacement force.

20.
Int J Numer Method Biomed Eng ; 38(9): e3636, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35778375

RESUMO

INTRODUCTION: Left subclavian artery (LSA) bypass surgery is mainly carried out for patients with severe left subclavian occlusion. This article aimed to evaluate the hemodynamic effects of different surgical bypass modes on LSA revascularization. METHODS: Three-dimensional models of the aorta were reconstructed from CTA images of a patient with LSA occlusion, a patient with type B aortic dissection with LSA coverage during thoracic endovascular aortic repair, and a healthy 74-year-old man, resulting in six modes for each person: healthy LSA mode, LSA occlusion mode and four bypass modes. Hemodynamic parameters, including flow field, flow distribution, pressure gradient, and wall shear stress, were calculated using computational fluid dynamics. RESULTS: After LSA bypass surgery, distal LSA blood flow resulting from left common carotid artery (LCCA) to distal LSA bypass was 100% of that in the healthy mode, while the other modes yielded flows at least 91%. Moreover, reversed flow only completely disappeared with LCCA to distal LSA bypass, whereas reverse flow was observed in the other three modes in early systole. CONCLUSION: Left common carotid artery to distal LSA bypass can effectively reduce reverse blood flow in the left vertebral artery, and it is a feasible, effective, and safe option for LSA revascularization in patients with left subclavian occlusion.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Humanos , Masculino , Stents/efeitos adversos , Artéria Subclávia/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA