Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BMC Musculoskelet Disord ; 24(1): 648, 2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37573304

RESUMO

PURPOSE: Postoperative limb length discrepancy (LLD) is a common complication of total hip arthroplasty, and several methods exist to prevent LLD, but each has its benefits and drawbacks. The study investigates the application of intraoperative lower limb length measurement in preventing postoperative LLD. METHODS: This study retrospectively analyzed 70 patients who underwent total hip arthroplasty from October 2018 to July 2022. The length of the lower limb on the operated side was measured intraoperatively using a sterilized paper ruler after the fitting of the trial mould and compared with the healthy side. Then the prosthesis size, depth and neck length were adjusted accordingly. RESULTS: The absolute value of postoperative LLD was found to be 6.68 ± 4.48 mm, of which 53 cases (75.7%) were less than or equal to 10 mm, while 30 patients (42.9%) were less than or equal to 5 mm. CONCLUSION: The use of intraoperative measurement is effective in reducing LLD after total hip arthroplasty.


Assuntos
Artroplastia de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/prevenção & controle , Desigualdade de Membros Inferiores/cirurgia , Extremidade Inferior/cirurgia , Período Pós-Operatório
2.
J Cell Physiol ; 234(11): 19895-19910, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30963578

RESUMO

Circular RNAs (circRNAs) are a new class of RNAs, and many studies have identified thousands of circRNAs in tumor cells. Fibronectin type III domain-containing protein 3B (FNDC3B) circular RNA (circFNDC3B, circBase ID: hsa_circ_0006156) circularizes with exons 5 and 6. Gibson Assembly DNA technology was used to construct a circFNDC3B expression vector without a splice site and restriction enzyme site. We showed that circFNDC3B increased migration and invasion in gastric cancer (GC). Ectopic expression of circFNDC3B reduced the level of E-cadherin protein to promote the epithelial-mesenchymal transition in GC. RNA immunoprecipitation assays and RNA pull-down assays confirmed that circFNC3B increased CD44 expression, which was associated with cell adhesion, via the formation of a ternary complex of circFNDC3B-IGF2BP3-CD44 mRNA. These results indicated that circFNDC3B was associated with the degree of malignancy to highlight the specific characteristics of cell invasion.


Assuntos
Antígenos CD/genética , Caderinas/genética , Movimento Celular/genética , Regulação Neoplásica da Expressão Gênica , Receptores de Hialuronatos/genética , RNA Circular/metabolismo , Neoplasias Gástricas/genética , Neoplasias Gástricas/patologia , Antígenos CD/metabolismo , Sequência de Bases , Caderinas/metabolismo , Linhagem Celular Tumoral , Humanos , Receptores de Hialuronatos/metabolismo , Invasividade Neoplásica , RNA Circular/genética , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Proteínas de Ligação a RNA/metabolismo
3.
Zhongguo Gu Shang ; 27(12): 1015-8, 2014 Dec.
Artigo em Zh | MEDLINE | ID: mdl-25638889

RESUMO

OBJECTIVE: To explore clinical effects of suturing-assisted locking plate in treating elderly proximal humeral fractures. METHODS: From January 2005 to January 2013, 55 elderly patients with three- and four-part fractures of proximal humeral fractures were divided into treatment group and control group. In treatment group, there were 31 patients including 12 males, and 19 females aged from 65 to 85 with an average of (74.00±5.42) years old, and treated with suturing-assisted locking plates; 19 patients were Neer 3-part fractures, and 12 patients were Neer 4-part fractures of proximal humerus; 23 patients were suffered from low-energy injuries and 8 patients were caused by high-energy injuries. In control group, there were 24 patients including 7 males, and 17 females aged from 65 to 85 with an average of (72.79±5.34) years old, and treated with locking plates; 16 patients were Neer 3-part fractures, and 8 patients were Neer 4-part fractures of proximal humerus; 17 patients were suffered from low-energy injuries and 7 patients were caused by high-energy injuries. Operative time, blood loss during operation, and bone healing time between two groups were observed and compared. Postoperative Neer scoring were used to evaluate recovery of shoulder joint function. RESULTS: All patients were followed up from 6 to 24 months with an average of 16.1 months. In treatment group, blood loss was (495.806±143.150) ml, function of Neer scoring was 22.645±2.443, range of action was 18.194±2.613, anatomy was 7.935±1.504 and total score of Neer scoring was 77.161±8.335; while in control group, blood loss was (641.667±169.851) ml, function of Neer scoring was 13.958±1.989, range of action was 13.083±2.165, anatomy was 5.500±1.978 and total score of Neer scoring was 58.792±7.313. There were sigificant difference between two groups in these indexes. CONCLUSION: Suturing-assisted locking plate for the treatment of proximal humerus fractures in elderly, has advantages of less blood loss, simple fracture reduction and rapid recovery of shoulder joint, and is a effective method.


Assuntos
Placas Ósseas , Fraturas do Ombro/cirurgia , Suturas , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Recuperação de Função Fisiológica , Fraturas do Ombro/fisiopatologia , Articulação do Ombro/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA