Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Strahlenther Onkol ; 194(8): 727-736, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29556677

RESUMO

PURPOSE: To evaluate feasibility, disease control, survival, and toxicity after adaptive 18F-fluorodeoxyglucose (FDG) positron emisson tomography (PET) guided radiotherapy in patients with recurrent and second primary head and neck squamous cell carcinoma. METHODS: A prospective trial investigated the feasibility of adaptive intensity modulated radiotherapy (IMRT) ± concomitant cetuximab in 10 patients. The primary endpoint was achieving a 2-year survival free of grade >3 toxicity in ≥30% of patients. Three treatment plans based on 3 PET/CT scans were consecutively delivered in 6 weeks. The range of dose painting was 66.0-85.0 Gy in the dose-painted tumoral volumes in 30 fractions. RESULTS: Two-year locoregional and distant control rates were 38 and 76%, respectively. Overall and disease-free survival at 2 years was 20%. No grade 4 or 5 acute toxicity was observed in any of the patients, except for arterial mucosal hemorrhage in 1 patient. Three months after radiotherapy, grade 4 dysphagia and mucosal wound healing problems were observed in 1/7 and 1/6 of patients, respectively. Grade 5 toxicity (fatal bleeding) was seen in 2 patients, at 3.8 and 4.1 months of follow-up. Data on 2­year toxicity could only be assessed in 1 of the 2 surviving patients, in whom grade 4 mucosal wound healing problems were observed; no other grade >3 toxicity was observed. In this respect, a 30% 2­year survival free of grade >3 toxicity will not be achieved. CONCLUSIONS: Adaptive PET-guided reirradiation is feasible. However, due to slow accrual and treatment results that seemed inconsistent with achieving the primary endpoint, the trial was stopped early.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Recidiva Local de Neoplasia/radioterapia , Neoplasias Induzidas por Radiação/radioterapia , Segunda Neoplasia Primária/radioterapia , Neoplasias Otorrinolaringológicas/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Carcinoma de Células Escamosas/mortalidade , Cetuximab/uso terapêutico , Feminino , Fluordesoxiglucose F18 , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Neoplasias Induzidas por Radiação/mortalidade , Segunda Neoplasia Primária/mortalidade , Neoplasias Otorrinolaringológicas/mortalidade , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Lesões por Radiação/etiologia , Lesões por Radiação/mortalidade , Planejamento da Radioterapia Assistida por Computador
2.
Oncologist ; 20(3): 279-90, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25673104

RESUMO

BACKGROUND: We report on a retrospective analysis of 147 patients with early and locoregionally advanced squamous cell head and neck cancer (SCCHN) treated with helical tomotherapy (HT). PATIENTS AND METHODS: Included were patients with SCCHN of the oral cavity (OC), oropharynx (OP), hypopharynx (HP), or larynx (L) consecutively treated in one radiotherapy center in 2008 and 2009. The prescribed HT dose was 60-66 Gy in the postoperative setting (group A) and 66-70 Gy when given as primary treatment (group B). HT was given alone, concurrent with systemic therapy (ST), that is, chemotherapy, biotherapy, or both, and with or without induction therapy (IT). Acute and late toxicities are reported using standard criteria; locoregional failure/progression (LRF), distant metastases (DM), and second primary tumors (SPT) were documented, and event-free survival (EFS) and overall survival (OS) were calculated from the start of HT. RESULTS: Group A patients received HT alone in 22 cases and HT + ST in 20 cases; group B patients received HT alone in 17 cases and HT + ST in 88 cases. Severe (grade ≥ 3) acute mucosal toxicity and swallowing problems increased with more additional ST. After a median follow-up of 44 months, grade ≥2 late toxicity after HT + ST was approximately twice that of HT alone for skin, subcutis, pharynx, and larynx. Forty percent had grade ≥2 late xerostomia, and 29% had mucosal toxicity. At 3 years, LRF/DM/SPT occurred in 7%/7%/17% and 25%/13%/5% in groups A and B, respectively, leading to a 3-year EFS/OS of 64%/74% and 56%/63% in groups A and B, respectively. CONCLUSION: The use of HT alone or in combination with ST is feasible and promising and has a low late fatality rate. However, late toxicity is nearly twice as high when ST is added to HT.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia de Intensidade Modulada/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica , Terapia Combinada , Progressão da Doença , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Segunda Neoplasia Primária , Dosagem Radioterapêutica , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
3.
Phys Imaging Radiat Oncol ; 29: 100525, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38204910

RESUMO

Background and purpose: Treatment plans in radiotherapy are subject to measurement-based pre-treatment verifications. In this study, plan complexity metrics (PCMs) were calculated per beam and used as input features to develop a predictive model. The aim of this study was to determine the robustness against differences in machine type and institutional-specific quality assurance (QA). Material and methods: A number of 567 beams were collected, where 477 passed and 90 failed the pre-treatment QA. Treatment plans of different anatomical regions were included. One type of linear accelerator was represented. For all beams, 16 PCMs were calculated. A random forest classifier was trained to distinct between acceptable and non-acceptable beams. The model was validated on other datasets to investigate its robustness. Firstly, plans for another machine type from the same institution were evaluated. Secondly, an inter-institutional validation was conducted on three datasets from different centres with their associated QA. Results: Intra-institutionally, the PCMs beam modulation, mean MLC gap, Q1 gap, and Modulation Complexity Score were the most informative to detect failing beams. Eighty-tree percent of the failed beams (15/18) were detected correctly. The model could not detect over-modulated beams of another machine type. Inter-institutionally, the model performance reached higher accuracy for centres with comparable equipment both for treatment and QA as the local institute. Conclusions: The study demonstrates that the robustness decreases when major differences appear in the QA platform or in planning strategies, but that it is feasible to extrapolate institutional-specific trained models between centres with similar clinical practice. Predictive models should be developed for each machine type.

4.
Oncologist ; 18(6): 697-706, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23723331

RESUMO

A decade after its first introduction into the clinic, little is known about the clinical impact of helical tomotherapy (HT) on head and neck cancer (HNC) treatment. Therefore, we analyzed the basics of this technique and reviewed the literature regarding HT's potential benefit in HNC. The past two decades have been characterized by a huge technological evolution in photon beam radiotherapy (RT). In HNC, static beam intensity-modulated radiotherapy (IMRT) has shown superiority over three-dimensional conformal RT in terms of xerostomia and is considered the standard of care. However, the next-generation IMRT, the rotational IMRT, has been introduced into the clinic without any evidence of superiority over static beam IMRT other than being substantially faster. Of these rotational techniques, HT is the first system especially developed for IMRT in combination with image-guided RT. HT is particularly promising for the treatment of HNC because its sharp dose gradients maximally spare the many radiosensitive organs at risk nearby. In addition, HT's integrated computed tomography scan assures a very precise dose administration and allows for some adaptive RT. Because HT is specifically developed for IMRT in combination with (integrated) image-guidance, it allows for precise dose distribution ("dose painting"), patient setup, and dose delivery. As such, it is an excellent tool for difficult HNC irradiation. The literature on the clinical results of HT in HNC all show excellent short-term (≤2 years) results with acceptable toxicity profiles. However, properly designed trials are still warranted to further substantiate these results.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Dosagem Radioterapêutica , Ensaios Clínicos Controlados Aleatórios como Assunto , Tomografia Computadorizada por Raios X
5.
Phys Imaging Radiat Oncol ; 28: 100494, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37809056

RESUMO

Background and Purpose: Clinical Artificial Intelligence (AI) implementations lack ground-truth when applied on real-world data. This study investigated how combined geometrical and dose-volume metrics can be used as performance monitoring tools to detect clinically relevant candidates for model retraining. Materials and Methods: Fifty patients were analyzed for both AI-segmentation and planning. For AI-segmentation, geometrical (Standard Surface Dice 3 mm and Local Surface Dice 3 mm) and dose-volume based parameters were calculated for two organs (bladder and anorectum) to compare AI output against the clinically corrected structure. A Local Surface Dice was introduced to detect geometrical changes in the vicinity of the target volumes, while an Absolute Dose Difference (ADD) evaluation increased focus on dose-volume related changes. AI-planning performance was evaluated using clinical goal analysis in combination with volume and target overlap metrics. Results: The Local Surface Dice reported equal or lower values compared to the Standard Surface Dice (anorectum: (0.93 ± 0.11) vs (0.98 ± 0.04); bladder: (0.97 ± 0.06) vs (0.98 ± 0.04)). The ADD metric showed a difference of (0.9 ± 0.8)Gy for the anorectum D1cm3. The bladder D5cm3 reported a difference of (0.7 ± 1.5)Gy. Mandatory clinical goals were fulfilled in 90 % of the DLP plans. Conclusions: Combining dose-volume and geometrical metrics allowed detection of clinically relevant changes, applied to both auto-segmentation and auto-planning output and the Local Surface Dice was more sensitive to local changes compared to the Standard Surface Dice. This monitoring is able to evaluate AI behavior in clinical practice and allows candidate selection for active learning.

6.
J Natl Cancer Cent ; 3(2): 135-140, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39035727

RESUMO

Objective: NCT01780675, a multicenter randomized phase III trial of prophylactic cranial irradiation (PCI) versus PCI with hippocampal sparing in small cell lung cancer (SCLC) investigated neurocognitive decline and safety. As part of quality assurance, we evaluated if hippocampal avoidance (HA)-PCI was performed according to the NCT01780675 trial protocol instructions, and performed a safety analysis to study the incidence and location of brain metastases for patients treated with HA-PCI. Methods: This retrospective analysis evaluated the quality of the irradiation given in the randomized controlled trial (RCT) comparing SCLC patients receiving PCI with or without hippocampal avoidance, using intensity modulated radiotherapy (IMRT) or volumetric modulated arc therapy (VMAT). The dose distribution for each patient receiving HA-PCI was retrieved and analyzed to evaluate if the treatment dose constraints were met. A questionnaire was sent out to all participating sites, and data on radiotherapy technique, pre-treatment dummy runs, phantom measurements and treatment electronic portal imaging device (EPID) dosimetry were collected and analyzed. As part of the safety analysis, the follow-up magnetic resonance imaging (MRI) or computerized tomography (CT) scans on which cranial disease progression was first diagnosed were collected and matched to the radiotherapy planning dose distribution. The matched scans were reviewed to analyze the location of the brain metastases in relation to the prescribed dose. Results: A total of 168 patients were randomized in the NCT01780675 trial in 10 centers in the Netherlands and Belgium from April 2013 until March 2018. Eighty two patients receiving HA-PCI without evidence of brain metastases were analyzed. All patients were treated with 25 Gy in 10 fractions. Dummy runs and phantom measurements were performed in all institutions prior to enrolling patients into the study. The radiotherapy (RT) plans showed a median mean bilateral hippocampal dose of 8.0 Gy, range 5.4-11.4 (constraint ≤ 8.5 Gy). In six patients (7.3%) there was a protocol violation of the mean dose in one or both hippocampi. In four of these six patients (4.9%) the mean dose to both hippocampi exceeded the constraint, in 1 patient (1.2%) only the left and in 1 patient (1.2%) only the right hippocampal mean dose was violated (average median dose left and right 8.9 Gy). All patients met the trial dose constraint of V 115% PTV ≤ 1%; however the D max PTV constraint of ≤ 28.75 Gy was violated in 22.0% of the patients. The safety analysis showed that 14 patients (17.1%) developed cranial progression. No solitary brain metastases in the underdosed region were found. Two out of 11 patients with multiple brain metastasis developed metastasis in the underdosed region(s). Conclusions: The radiotherapy quality within the HA-PCI trial is performed according to the protocol guidelines. The dose constraints to the hippocampi are met in the vast majority of cases. In all patients, the volume of the brain for which a higher dose was accepted, is according to the trial. However, within this volume there are small areas with higher doses than advised.

7.
Artigo em Inglês | MEDLINE | ID: mdl-36039333

RESUMO

Purpose: A fully independent, machine learning-based automatic treatment couch parameters prediction was developed to support surface guided radiation therapy (SGRT)-based patient positioning protocols. Additionally, this approach also acts as a quality assurance tool for patient positioning. Materials/Methods: Setup data of 183 patients, divided into four different groups based on used setup devices, was used to calculate the difference between the predicted and the acquired treatment couch value. Results: Couch parameters can be predicted with high precision µ = 0.90 , σ = 0.92 . A significant difference (p < 0.01) between the variances of Lung and Brain patients was found. Outliers were not related to the prediction accuracy, but are due to inconsistencies during initial patient setup. Conclusion: Couch parameters can be predicted with high accuracy and can be used as starting point for SGRT-based patient positioning. In case of large deviations (>1.5 cm), patient setup has to be verified to optimally use the surface scanning system.

8.
Phys Med Biol ; 67(11)2022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35561701

RESUMO

Objective.The output of a deep learning (DL) auto-segmentation application should be reviewed, corrected if needed and approved before being used clinically. This verification procedure is labour-intensive, time-consuming and user-dependent, which potentially leads to significant errors with impact on the overall treatment quality. Additionally, when the time needed to correct auto-segmentations approaches the time to delineate target and organs at risk from scratch, the usability of the DL model can be questioned. Therefore, an automated quality assurance framework was developed with the aim to detect in advance aberrant auto-segmentations.Approach. Five organs (prostate, bladder, anorectum, femoral head left and right) were auto-delineated on CT acquisitions for 48 prostate patients by an in-house trained primary DL model. An experienced radiation oncologist assessed the correctness of the model output and categorised the auto-segmentations into two classes whether minor or major adaptations were needed. Subsequently, an independent, secondary DL model was implemented to delineate the same structures as the primary model. Quantitative comparison metrics were calculated using both models' segmentations and used as input features for a machine learning classification model to predict the output quality of the primary model.Main results. For every organ, the approach of independent validation by the secondary model was able to detect primary auto-segmentations that needed major adaptation with high sensitivity (recall = 1) based on the calculated quantitative metrics. The surface DSC and APL were found to be the most indicated parameters in comparison to standard quantitative metrics for the time needed to adapt auto-segmentations.Significance. This proposed method includes a proof of concept for the use of an independent DL segmentation model in combination with a ML classifier to improve time saving during QA of auto-segmentations. The integration of such system into current automatic segmentation pipelines can increase the efficiency of the radiotherapy contouring workflow.


Assuntos
Aprendizado Profundo , Órgãos em Risco , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Masculino , Órgãos em Risco/diagnóstico por imagem , Próstata , Planejamento da Radioterapia Assistida por Computador/métodos
9.
Phys Med Biol ; 66(5): 055003, 2021 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-33470973

RESUMO

We demonstrate the application of mixture density networks (MDNs) in the context of automated radiation therapy treatment planning. It is shown that an MDN can produce good predictions of dose distributions as well as reflect uncertain decision making associated with inherently conflicting clinical tradeoffs, in contrast to deterministic methods previously investigated in the literature. A two-component Gaussian MDN is trained on a set of treatment plans for postoperative prostate patients with varying extents to which rectum dose sparing was prioritized over target coverage. Examination on a test set of patients shows that the predicted modes follow their respective ground truths well, both spatially and in terms of their dose-volume histograms. A special dose mimicking method based on the MDN output is used to produce deliverable plans and thereby showcase the usability of voxel-wise predictive densities. Thus, this type of MDN may serve to support clinicians in managing clinical tradeoffs and has the potential to improve the quality of plans produced by an automated treatment planning pipeline.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Automação , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Probabilidade , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Reto/efeitos dos fármacos
10.
Phys Med Biol ; 65(15): 155006, 2020 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-32330917

RESUMO

Modelling of the multi-leaf collimator (MLC) in treatment planning systems (TPS) is crucial for the dose calculation accuracy of intensity-modulated radiation therapy plans. However, no standardised methodology for their configuration exists to date. In this study we present a method that separates the effect of each dosimetric characteristic of the MLC, offering comprehensive equations for the determination of the configuration parameters used in the TPS model. The main advantage of the method is that it only requires prior knowledge of the nominal leaf width and is based on doses measured with a Farmer chamber, which is a very well established and robust methodology. Another significant advantage is the required time, since measuring the tests takes only about 30 minutes per energy. Firstly, we provide a theoretical general formalism in terms of the primary fluence constructed from the transmission map obtained from an MLC model for synchronous and asynchronous sweeping beams. Secondly, we apply the formalism to the RayStation TPS as a proof of concept and we derive analytical expressions that allow the determination of the configuration parameters (leaf tip width, tongue-and-groove width, x-position offset and MLC transmission) and describe how they intertwine. Finally, we apply the method to Varian's Millennium120 and HD120 MLCs in a TrueBeam linear accelerator for different energies and determine the optimal configuration parameters. The proposed procedure is much faster and streamlined than the typical trial-and-error methods and increases the accuracy of dose calculation in clinical plans. Additionally, the procedure can be useful for standardising the MLC configuration process and it exposes the limitations of the implemented MLC model, providing guidance for further improvement of these models in TPSs.


Assuntos
Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Humanos , Modelos Biológicos , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
11.
Clin Transl Radiat Oncol ; 24: 65-70, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32642561

RESUMO

BACKGROUND: To investigate progression free survival (PFS), local control (LC) and overall survival (OS) outcomes for patients treated with spine hypofractionated stereotactic ablative radiotherapy (SABR) and to evaluate possible predictors of rapid progression in view of a correct patient selection for this potentially curative SABR. MATERIALS AND METHODS: A cohort of 59 patients with spinal metastases were treated with SABR. Patient selection criteria were the following: histologically proven diagnosis of a solid tumor, a World Health Organization (WHO) score ≤ 2, life expectancy > 6 months, Spinal Instability Neoplastic Score (SINS) ≤ 12 points and presenting with radically treated oligometastatic disease (≤5 lesions) or stable polymetastatic disease with an oligoprogressive lesion. RESULTS: From March 2015 to June 2019, 59 patients were treated with Linac-based SABR to 64 spinal metastases with a median follow-up of 55 months. SABR was standard delivered every other day in 3 to 10 fractions with median prescription dose of 27 Gy (range 21-49 Gy).The 1-,2- and 5-year PFS was 98%, 85% and 75% for all patients. OS at 5 years for all patients was 92%. Metachronous lesions (p < 0.01; HR = 7.1) and oligometastatic (vs. oligoprogressive) lesions (p = 0.02; HR = 0.3) were associated with higher PFS in uni- and multivariate Cox regression analysis. No significant predictors in multivariate analysis were demonstrated for rapid progressors.Vertebral compression fractures developed de novo in 6.3% (4/64) of cases. The median time to fracture was 11 months (range 7-15) after treatment. No other adverse events ≥ 3 grade were observed. CONCLUSIONS: Tumor control and toxicity after high-dose hypofractionated SABR was evaluated in patients with spinal oligometastases. High rates of efficacy and minimal toxicity were demonstrated. Oligometastatic patients with metachronous spinal metastases seem to benefit the most from SABR.

12.
Radiother Oncol ; 142: 217-223, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31767472

RESUMO

BACKGROUND AND PURPOSE: In 2017 the ACROP guideline on SBRT for peripherally located early stage NSCLC was published. Later that year ICRU-91 about prescribing, recording and reporting was published. The purpose of this study is to quantify the current variation in prescription practice in the institutions that contributed to the ACROP guideline and to establish the link between the ACROP and ICRU-91 recommendations. MATERIAL AND METHODS: From each of the eight participating centres, 15 SBRT plans for stage I NSCLC were analyzed. Plans were generated following the institutional protocol, centres prescribed 3 × 13.5 Gy, 3 × 15 Gy, 3 × 17 Gy or 3 × 18 Gy. Dose parameters of the target volumes were reported as recommended by ICRU-91 and also converted to BED10Gy. RESULTS: The intra-institutional variance in D98%, Dmean and D2% of the PTV and GTV/ITV is substantially smaller than the inter-institutional spread, indicating well protocollised planning procedures are followed. The median values per centre ranged from 56.1 Gy to 73.1 Gy (D2%), 50.4 Gy to 63.3 Gy (Dmean) and 40.5 Gy to 53.6 Gy (D98%) for the PTV and from 57.1 Gy to 73.6 Gy (D2%), 53.7 Gy to 68.7 Gy (Dmean) and 48.5 Gy to 62.3 Gy (D98%) for the GTV/ITV. Comparing the variance in PTV D98% with the variance in GTV Dmean per centre, using an F-test, shows that four centres have a larger variance in GTV Dmean, while one centre has a larger variance in PTV D98% (p values <0.01). This shows some centres focus on achieving a constant PTV coverage while others aim at a constant GTV coverage. CONCLUSION: More detailed recommendations for dose planning and reporting of lung SBRT in line with ICRU-91 were formulated, including a minimum PTV D98% of 100 Gy BED10Gy and minimum GTV/ITV mean dose of 150 Gy BED10Gy and a D2% in the range of 60-70 Gy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Radiocirurgia/normas , Planejamento da Radioterapia Assistida por Computador/normas , Fidelidade a Diretrizes , Humanos , Guias de Prática Clínica como Assunto , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
13.
Radiat Oncol ; 10: 191, 2015 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-26377574

RESUMO

BACKGROUND: Modulation factor (MF) and pitch have an impact on Helical TomoTherapy (HT) plan quality and HT users mostly use vendor-recommended settings. This study analyses the effect of these two parameters on both plan quality and treatment time for plans made with TomoEdge planning software by using the concept of Pareto optimal fronts. METHODS: More than 450 plans with different combinations of pitch [0.10-0.50] and MF [1.2-3.0] were produced. These HT plans, with a field width (FW) of 5 cm, were created for five head and neck patients and homogeneity index, conformity index, dose-near-maximum (D2), and dose-near-minimum (D98) were analysed for the planning target volumes, as well as the mean dose and D2 for most critical organs at risk. For every dose metric the median value will be plotted against treatment time. A Pareto-like method is used in the analysis which will show how pitch and MF influence both treatment time and plan quality. RESULTS: For small pitches (≤0.20), MF does not influence treatment time. The contrary is true for larger pitches (≥0.25) as lowering MF will both decrease treatment time and plan quality until maximum gantry speed is reached. At this moment, treatment time is saturated and only plan quality will further decrease. CONCLUSION: The Pareto front analysis showed optimal combinations of pitch [0.23-0.45] and MF > 2.0 for a FW of 5 cm. Outside this range, plans will become less optimal. As the vendor-recommended settings fall within this range, the use of these settings is validated.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Software , Humanos , Órgãos em Risco , Neoplasias Orofaríngeas/radioterapia , Dosagem Radioterapêutica
14.
Radiat Oncol ; 10: 261, 2015 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-26701749

RESUMO

BACKGROUND: The last few years, in radiotherapy there has been a growing focus on speed of treatment delivery (largely driven by economical and commercial interests). This study investigates the influence of treatment time on plan quality for helical tomotherapy (HT), using delivery times with Volumetric Modulated Arc Therapy (VMAT; Rapid Arc [RA]) as reference. METHODS: In a previous study, double arc RA (Eclipse) and standard HT plans (TomoHD™) were created for five oropharyngeal cancer patients and reported according to ICRU 83 guidelines. By modifying the beam width from 2.5 to 5.0 cm, elevating the pitch and lowering the modulation factor, "TomoFast" (TF) plans were generated with treatment times equal to RA plans. To quantify the impact of TF's craniocaudal gradient, similar plans were generated on TomoEdge(TM) (TomoEdgeFast;TEF). The homogeneity index (HI), conformity index (CI), mean dose, Dnear-max (D2) and Dnear-min (D98) of the PTVs were analyzed as well as the mean dose, specific critical doses and volumes of 26 organs at risk (OARs). Data were analyzed using repeated measures ANOVA. RESULTS: With a mean treatment time of 3.05 min (RA), 2.89 min (TF) and 2.95 min (TEF), PTVtherapeutic coverage was more homogeneous with TF (HI.07;SE.01) and TEF (HI.08;SE.01) compared to RA (HI.10;SE.01), while PTVprophylactic was most homogeneous with RA. Mean doses to parotid glands were comparable for RA, TF, TEF: 25.62, 25.34, 23.09 Gy for contralateral and 32.02, 31.96, 30.01 Gy for ipsilateral glands, respectively. OARs' mean doses varied between different approaches not favoring a particular technique. TF's higher dose to OARs at the cranial-caudal edges of the PTVs and its higher integral dose, both due to the extended cranial-caudal gradient, seems to be solved by the new TomoEdge™ software. However, all these faster techniques lose part of standard TomoHD's OAR sparing capacity CONCLUSION: It is possible to treat oropharyngeal cancer patients using HT (TF/TEF) within time-frames observed for RA maintaining comparable target coverage and sparing of OARs. This study indicates that treatment time is not technology specific, rather an operator's decision on balancing efficiency and quality.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tempo para o Tratamento , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA