Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Emerg Infect Dis ; 22(2): 210-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26812466

RESUMO

Rapid diagnostic methods are essential in control of Ebola outbreaks and lead to timely isolation of cases and improved epidemiologic surveillance. Diagnosis during Ebola outbreaks in West Africa has relied on PCR performed in laboratories outside this region. Because time between sampling and PCR results can be considerable, we assessed the feasibility and added value of using the Xpert Ebola Assay in an Ebola control program in Guinea. A total of 218 samples were collected during diagnosis, treatment, and convalescence of patients. Median time for obtaining results was reduced from 334 min to 165 min. Twenty-six samples were positive for Ebola virus. Xpert cycle thresholds were consistently lower, and 8 (31%) samples were negative by routine PCR. Several logistic and safety issues were identified. We suggest that implementation of the Xpert Ebola Assay under programmatic conditions is feasible and represents a major advance in diagnosis of Ebola virus disease without apparent loss of assay sensitivity.


Assuntos
Ebolavirus/genética , Doença pelo Vírus Ebola/diagnóstico , Doença pelo Vírus Ebola/virologia , Tipagem Molecular/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Genes Virais , Guiné , Doença pelo Vírus Ebola/epidemiologia , Doença pelo Vírus Ebola/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Tipagem Molecular/normas , RNA Viral , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
2.
BMC Infect Dis ; 14: 553, 2014 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-25330812

RESUMO

BACKGROUND: CD4+ T-cell testing of blood specimens collected in standard EDTA Vacutainer tubes and transported at ambient temperature, must be completed within 48 hours with the BD FACSCount™ flow cytometer, restricting specimen collection in remote clinics with no on-site testing and limited specimen transport services. We conducted a study in Buhera District, Zimbabwe, to assess the stability and accuracy of CD4+ T-cell results of samples collected in Stabilization Tubes (ST) and stored at ambient temperature for varying time periods. METHODS: Paired EDTA and ST samples were collected from 51 HIV-positive patients aged 18 years and older. CD4+ T-cell testing was done on arrival in the laboratory (Day 0). ST samples were retested on Days 3, 5, and 7. Nineteen ST samples were stored for an additional week and retested on Day 14. RESULTS: There was a strong correlation between absolute CD4+ T-cell counts measured in the EDTA Day 0 reference sample and Day 7 ST sample (Spearman's rho: 0.9778; mean difference: -4.9 cells/µL and limits of agreement (LOA): 98.5 and 88.7 cells/µL); and the reference sample and Day 14 ST sample (Spearman's rho: 0.9632; mean difference 5.1 cells/µL and LOA: -99.6 and 109.8 cells/µL. Using a 350 cells/µL threshold, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were all 100% on Day 7, and 83.3%, 100%, 100% and 92.9% on Day 14. Using a 500 cells/µL threshold, the sensitivity, specificity, PPV and NVP were 100%, 88.5%, 88.5% and 100% on Day 7 and 88.9%, 80.0%, 80.0% and 88.9% on Day 14. CONCLUSIONS: CD4 ST can be used and stored up to 7 days as a reliable alternative to standard EDTA tubes in settings where CD4+ T-cell testing within 48 hours is not feasible. Despite the small sample size, results suggest that ST may be stored up to 14 days at room temperature for CD4 testing, without compromising accuracy. However, further studies with larger sample sizes are needed to confirm this preliminary finding.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Infecções por HIV/sangue , Adulto , Anticoagulantes/química , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Contagem de Linfócito CD4/instrumentação , Contagem de Linfócito CD4/métodos , Contagem de Linfócito CD4/normas , Linfócitos T CD4-Positivos/imunologia , Ácido Edético/química , Feminino , Citometria de Fluxo , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , População Rural , Sensibilidade e Especificidade , Meios de Transporte , Zimbábue
3.
J Immunol ; 184(11): 6367-77, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20421647

RESUMO

IL-17-producing T lymphocytes play a crucial role in inflammation, but their possible implication in fibrosis remains to be explored. In this study, we examined the involvement of these cells in a mouse model of lung inflammation and fibrosis induced by silica particles. Upregulation of IL-17A was associated with the development of experimental silicosis, but this response was markedly reduced in athymic, gammadelta T cell-deficient or CD4(+) T cell-depleted mice. In addition, gammadelta T lymphocytes and CD4(+) T cells, but not macrophages, neutrophils, NK cells or CD8 T cells, purified from the lungs of silicotic mice markedly expressed IL-17A. Depletion of alveolar macrophages or neutralization of IL-23 reduced upregulation of IL-17A in the lung of silicotic mice. IL-17R-deficient animals (IL-17R(-/-)) or IL-17A Ab neutralization, but not IL-22(-/-) mice, developed reduced neutrophil influx and injury during the early lung response to silica. However, chronic inflammation, fibrosis, and TGF-beta expression induced by silica were not attenuated in the absence of IL-17R or -22 or after IL-17A Ab blockade. In conclusion, a rapid lung recruitment of IL-17A-producing T cells, mediated by macrophage-derived IL-23, is associated with experimental silicosis in mice. Although the acute alveolitis induced by silica is IL-17A dependent, this cytokine appears dispensable for the development of the late inflammatory and fibrotic lung responses to silica.


Assuntos
Interleucina-17/imunologia , Pneumonia/imunologia , Fibrose Pulmonar/imunologia , Silicose/imunologia , Subpopulações de Linfócitos T/imunologia , Linfócitos T/imunologia , Animais , Separação Celular , Modelos Animais de Doenças , Citometria de Fluxo , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos DBA , Pneumonia/patologia , Reação em Cadeia da Polimerase , Fibrose Pulmonar/patologia , RNA Mensageiro/análise , Receptores de Antígenos de Linfócitos T gama-delta , Silicose/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA