RESUMO
AIMS: Heyde syndrome is the co-occurrence of aortic stenosis, acquired von Willebrand syndrome, and gastrointestinal bleeding. Aortic valve replacement has been demonstrated to resolve all three associated disorders. A systematic review and meta-analysis were performed to obtain best estimates of the effect of aortic valve replacement on acquired von Willebrand syndrome and gastrointestinal bleeding. METHODS AND RESULTS: A literature search was performed to identify articles on Heyde syndrome and aortic valve replacement up to 25 October 2022. Primary outcomes were the proportion of patients with recovery of acquired von Willebrand syndrome within 24 h (T1), 24-72 h (T2), 3-21 days (T3), and 4 weeks to 2 years (T4) after aortic valve replacement and the proportion of patients with cessation of gastrointestinal bleeding. Pooled proportions and risk ratios were calculated using random-effects models. Thirty-three studies (32 observational studies and one randomized controlled trial) on acquired von Willebrand syndrome (n = 1054), and 11 observational studies on gastrointestinal bleeding (n = 300) were identified. One study reported on both associated disorders (n = 6). The pooled proportion of Heyde patients with acquired von Willebrand syndrome recovery was 86% (95% CI, 79%-91%) at T1, 90% (74%-96%) at T2, 92% (84%-96%) at T3, and 87% (67%-96%) at T4. The pooled proportion of Heyde patients with gastrointestinal bleeding cessation was 73% (62%-81%). Residual aortic valve disease was associated with lower recovery rates of acquired von Willebrand syndrome (RR 0.20; 0.05-0.72; P = 0.014) and gastrointestinal bleeding (RR 0.57; 0.40-0.81; P = 0.002). CONCLUSION: Aortic valve replacement is associated with rapid recovery of the bleeding diathesis in Heyde syndrome and gastrointestinal bleeding cessation. Residual valve disease compromises clinical benefits.
Assuntos
Angiodisplasia , Estenose da Valva Aórtica , Doenças de von Willebrand , Humanos , Valva Aórtica/cirurgia , Angiodisplasia/complicações , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Doenças de von Willebrand/complicações , Hemorragia Gastrointestinal/cirurgia , Hemorragia Gastrointestinal/complicações , Síndrome , Fator de von WillebrandRESUMO
BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.
RESUMO
Background: If surgical revascularization is not feasible, high-risk PCI is a viable option for patients with complex coronary artery disease. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) provides hemodynamic support in patients with a high risk for periprocedural cardiogenic shock. Objective: This study aims to provide data about short-term outcomes of elective high-risk PCI with ECMO support. Methods: A retrospective single-center registry was performed on patients with high-risk PCI receiving VA-ECMO support. The short-term outcome was defined as the incidence of major adverse cardiac events (MACE) during the hospital stay and within 60 days after discharge. Results: Between January 2020 and December 2021, 14 patients underwent high-risk PCI with ECMO support. The mean age was 66.5 (±2.5) and the majority was male (71.4%) with a mean left ventricular ejection fraction of 33% (±3.0). Complexity indexes were high (STS-PROM risk score: 2.9 (IQR 1.5-5.8), SYNTAX score I: 35.5 (±2.0), SYNTAX score II (PCI): 49.8 (±3.2)). Femoral artery ECMO cannulation was performed in 13 patients (92.9%) requiring additional antegrade femoral artery cannula in one patient because of periprocedural limb ischemia. The mean duration of the ECMO run was 151 (±32) minutes. One patient required prolonged ECMO support and was weaned after 2 days. Successful revascularization was achieved in 13 patients (92.8%). Procedural success was achieved in 12 patients (85.7%) due to one unsuccessful revascularization and one procedural death. MACE during hospital stay occurred in 4 patients (28.6%) and within 60 days after discharge in 2 patients (16.7%). Conclusion: High-risk PCI with hemodynamic support using VA-ECMO is a feasible treatment option, if surgical revascularization is considered very high risk. Larger and prospective studies are awaited to confirm the benefits of ECMO support in elective high-risk PCI comparing ECMO with other mechanical circulatory support devices, including coaxial left cardiac support devices and IABP. Trial Registration. This trial is registered with NCT05387902.
Assuntos
Oxigenação por Membrana Extracorpórea , Intervenção Coronária Percutânea , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/cirurgia , Volume Sistólico , Função Ventricular EsquerdaRESUMO
BACKGROUND AND AIM OF THE STUDY: The coronavirus disease 2019 (COVID-19) pandemic has put an enormous strain on healthcare systems and intensive care unit (ICU) capacity, leading to suspension of most elective procedures, including transcatheter aortic valve replacement (TAVR). However, deferment of TAVR is associated with significant wait-time mortality in patients with severe aortic valve stenosis. Conversely, there is currently no data available regarding the safety and feasibility of a continued TAVR program during this unprecedented crisis. The aim of this study is to evaluate the safety and feasibility of patients undergoing TAVR during the COVID-19 pandemic in our center, with specific emphasis on COVID-19 related outcomes. METHODS: All patients who underwent TAVR in our center between February 27, 2020, and June 30, 2020, were evaluated. Clinical outcomes were described in terms of Valve Academic Research Consortium 2 definitions. Patient follow-up was done by chart review and telephone survey. RESULTS: A total of 71 patients have undergone TAVR during the study period. Median age was 80 years, 63% were men, and 25% were inpatients. Procedural success was 99%. After TAVR, 30% involved admission to the ICU, and 94% were ultimately discharged to the cardiac care unit on the same day. Two patients (3%) had confirmed COVID-19 a few days after TAVR, and both died of COVID-19 pneumonia within 2 weeks after hospital discharge. CONCLUSIONS: A continued TAVR program during the COVID-19 pandemic is feasible despite limited hospital resources. However, COVID-19 related mortality after TAVR is of concern.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , COVID-19/epidemiologia , Pandemias , SARS-CoV-2 , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Comorbidade , Feminino , Humanos , Masculino , Países Baixos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
OBJECTIVES: To investigate the relative performance of treatment with a paclitaxel-eluting balloon (PEB) compared with an everolimus-eluting stent (EES) for in-stent restenosis (ISR) in patients with diabetes mellitus (DM). BACKGROUND: ISR remains a challenge in contemporary clinical practice, particularly in patients with DM. METHODS: In the multicenter randomized DARE trial, patients with BMS or DES ISR were randomized in a 1:1 fashion to treatment with a PEB or an EES. Patients underwent angiographic follow-up after 6 months. For the purpose of this analysis, the relative performance of PEB versus EES in diabetic patients was investigated. RESULTS: Of 278 patients enrolled in DARE, 88 (32%) had DM, of whom 46 were randomized to EES and 42 to PEB treatment. Of patients with DM, 48 (55%) had DES-ISR. Angiographic follow-up was available in 30 patients (72%) in the PEB group and 36 patients (78%) in the DES group. There were no differences in terms of 6-months minimal lumen diameter in diabetic patients treated with EES (1.46 ± 0.66 mm) versus PEB (1.78 ± 0.58 mm, P = 0.15). Adverse events at one year follow-up were similar in both groups, with Major Adverse Events (MAE, death, target vessel MI, or TVR) occurring in 17.4% in the EES group versus 11.9% in the PEB group, P = 0.44. CONCLUSIONS: In patients with ISR and DM, use of a PEB resulted in similar 6-months in-segment minimal lumen diameter and comparable rates of MAE. In-segment late loss at 6 months was significantly lower in the PEB arm. Although larger trials in DM patients with ISR are necessary, PEB is a promising treatment option obviating the need for additional stent implantation.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Diabetes Mellitus , Stents Farmacológicos , Everolimo/administração & dosagem , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Diabetes Mellitus/diagnóstico , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Transcatheter aortic valve replacement (TAVR) is the standard of care in aortic stenosis with results comparable to surgical aortic valve replacement. However, paravalvular regurgitation (PVR) is more common after TAVR. With the alteration of devices and implantation techniques, the incidence of moderate or more PVR has declined. Mild PVR is still common in around 30% of TAVR patients in low-risk trials. Progression of AS causes myocardial hypertrophy and varying degrees of diastolic dysfunction which may cause heart failure even in combination with small volumes of PVR. Any degree of PVR is associated with an increased risk of overall and cardiovascular mortality. Predictors of PVR are annular eccentricity, severe calcification of the aortic valve, bicuspid aortic valves, and type of prosthesis where balloon-expandable devices are associated with less PVR. PVR is diagnosed using echocardiography, aortic angiogram with or without videodensitometry, haemodynamic parameters, or cardiac magnetic resonance. PVR can be treated using post-dilation, interventional treatment using a vascular plug, or implantation of a second device. Successful post-dilation depends on balloon size which should at least be equal to or >95% of the mean annulus diameter. Implantation of a second device to reduce PVR is successful in â¼90% of cases, either through lengthening of the sealing skirt in case of inadequate position or through further expansion of the index device. Implantation of a vascular plug can successfully reduce PVR and reduce mortality.
RESUMO
AIMS: To compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: Two-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.
Assuntos
Insuficiência da Valva Aórtica , Imagem Cinética por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Feminino , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Estudos Prospectivos , Idoso de 80 Anos ou mais , Idoso , Imagem Cinética por Ressonância Magnética/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo , Complicações Pós-Operatórias/diagnóstico por imagem , Índice de Gravidade de Doença , Estudos de CoortesRESUMO
BACKGROUND: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement, posing an increased risk of heart failure and mortality. Accurate intraprocedural quantification of PVR is challenging. Both hemodynamic indices and videodensitometry can be used for intraprocedural assessment of PVR. We compared the predictive value of the isolated versus combined use of the hemodynamic index diastolic delta (DD) and videodensitometry for the incidence of relevant PVR 1 month after transcatheter aortic valve replacement. METHODS AND RESULTS: In this prospective cohort study, patients underwent periprocedural PVR assessment by DD and videodensitometry (using left ventricular outflow tract-aortic regurgitation [LVOT-AR]). Cardiac magnetic resonance served as reference modality for PVR assessment. Relevant PVR was defined as cardiac magnetic resonance-regurgitant fraction >20%. Fifty-one patients were enrolled in this study. Mean age was 80.6±5.2 years and 45.1% of patients were men. Mean LVOT-AR and cardiac magnetic resonance-regurgitant fraction were 8.2%±7.8% and 11.7%±9.6%, respectively. The correlation between DD and LVOT-AR was weak (r=-0.36). DD and LVOT-AR showed a comparable accuracy to predict relevant PVR (area under the curve 0.82, 95% CI: 0.69-0.95 versus area area under the time-density curve 0.80, 95% CI: 0.62-0.99). The combination of DD and LVOT-AR improved the prediction of relevant PVR (area under the time-density curve, 0.90, 95% CI: 0.81-0.99), and resulted in an increased concordance (86.3%) and positive predictive value (75%) compared with DD alone (76.5% and 40%, respectively), or LVOT-AR alone (82.3% and 50%, respectively). CONCLUSIONS: DD and videodensitometry are both accurate and feasible modalities for the assessment of PVR after transcatheter aortic valve replacement. The synergistic use of both techniques increases the predictive value for relevant PVR after transcatheter aortic valve replacement. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04281771.
Assuntos
Insuficiência da Valva Aórtica , Valor Preditivo dos Testes , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Diástole , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnósticoRESUMO
Background The femoral vein is commonly used as a pacemaker access site during transcatheter aortic valve replacement (TAVR). Using an upper arm vein as an alternative access site potentially causes fewer bleeding complications and shorter time to mobilization. We aimed to assess the safety and efficacy of an upper arm vein as a temporary pacemaker access site during TAVR. Methods We evaluated all patients undergoing TAVR in our center between January 2020 and January 2023. Upper arm, femoral, and jugular vein pacemaker access was used in 255 (45.8%), 191 (34.3%), and 111 (19.9%) patients, respectively. Clinical outcomes were analyzed according to pacemaker access in the overall population and in a propensity-matched population involving 165 upper arm and 165 femoral vein patients. Primary endpoint was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 pacemaker access site-related bleeding. Results In the overall population, primary endpoint was lowest for upper arm, followed by femoral and jugular vein access (2.4% vs. 5.8% vs. 10.8%, p = 0.003). Time to mobilization was significantly longer (p < 0.001) in the jugular cohort compared with the other cohorts. In the propensity-matched cohort, primary endpoint showed a trend toward lower occurrence in the upper arm compared with the femoral cohort (2.4% vs. 6.1%, p = 0.10). Time to mobilization was significantly shorter (480 vs. 1140 min, p < 0.001) in the upper arm cohort, with a comparable skin-to-skin time (83 vs. 85 min, p = 0.75). Cross-over from upper arm pacemaker access was required in 17 patients (6.3% of attempted cases via an upper arm vein). Conclusions Using an upper arm vein as a temporary pacemaker access site is safe and feasible. Its use might be associated with fewer bleeding complications and shorter time to mobilization compared with the femoral vein.
RESUMO
Non-culprit coronary artery lesions are commonly present in patients presenting with an acute coronary syndrome (ACS). Additional stenting of non-culprit lesions in addition to the culprit lesion intends to prevent secondary events caused by these lesions. At the same time, multiple trials have demonstrated the potential of proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors in reducing plaque size and changing plaque composition of non-culprit lesions. Whether intensive low-density lipoprotein cholesterol (LDL-C) reduction with PCSK9 inhibitor evolocumab improves non-culprit vessel hemodynamics, reduces the risk of plaque rupture of important non-culprit lesions, and might obviate the need for additional stenting has not been investigated. The "Functional Improvement of non-infarcT related coronary artery stenosis by Extensive LDL-C Reduction with a PCSK9 Antibody" (FITTER) trial is a multi-center, randomized, double-blind, placebo-controlled clinical trial for patients presenting with ACS and multivessel disease (MVD). After treatment of the culprit lesion, fractional flow reserve (FFR) is performed in non-culprit vessels amenable for percutaneous coronary intervention (PCI). Coronary intervention in patients with hemodynamically important non-critical lesions (FFR: 0.67-0.85) is staged after baseline imaging using near-infrared spectroscopy (NIRS) and intravascular ultrasound (IVUS). Eligible patients are randomized and treated for 12 weeks with either evolocumab or placebo, in addition to high-intensity statin therapy. Follow-up angiography with repeat FFR and IVUS-NIRS is scheduled at 12 weeks. Staged PCI is performed at the operator's discretion.The FITTER trial is the first study to evaluate the effect of maximal LDL-C reduction by the PCSK9 inhibitor evolocumab on invasively measured FFR, plaque size, and plaque composition in hemodynamically important non-culprit lesions, during a treatment period of just 12 weeks after an ACS. Currently, all patients have been included (August 2023) and data analysis is ongoing. Trial registration number: clinicaltrials.gov NCT04141579.
RESUMO
BACKGROUND: Transfemoral access is often used when large-bore guide catheters are required for percutaneous coronary intervention (PCI) of complex coronary lesions, especially when large-bore transradial access is contraindicated. Whether the risk of access site complications for these procedures may be reduced by ultrasound-guided puncture is unclear. AIMS: We aimed to show the superiority of ultrasound-guided femoral puncture compared to fluoroscopy-guided access in large-bore complex PCI with regard to access site-related Bleeding Academic Research Consortium 2, 3 or 5 bleeding and/or vascular complications requiring intervention during hospitalisation. METHODS: The ULTRACOLOR Trial is an international, multicentre, randomised controlled trial investigating whether ultrasound-guided large-bore femoral access reduces clinically relevant access site complications compared to fluoroscopy-guided large-bore femoral access in PCI of complex coronary lesions. RESULTS: A total of 544 patients undergoing complex PCI mandating large-bore (≥7 Fr) transfemoral access were randomised at 10 European centres (median age 71; 76% male). Of these patients, 68% required PCI of a chronic total occlusion. The primary endpoint was met in 18.9% of PCI with fluoroscopy-guided access and 15.7% of PCI with ultrasound-guided access (p=0.32). First-pass puncture success was 92% for ultrasound-guided access versus 85% for fluoroscopy-guided access (p=0.02). The median time in the catheterisation laboratory was 102 minutes versus 105 minutes (p=0.43), and the major adverse cardiovascular event rate at 1 month was 4.1% for fluoroscopy-guided access and 2.6% for ultrasound-guided access (p=0.32). CONCLUSIONS: As compared to fluoroscopy-guided access, the routine use of ultrasound-guided access for large-bore transfemoral complex PCI did not significantly reduce clinically relevant bleeding or vascular access site complications. A significantly higher first-pass puncture success rate was demonstrated for ultrasound-guided access. CLINICALTRIALS: gov identifier: NCT04837404.
Assuntos
Artéria Femoral , Intervenção Coronária Percutânea , Ultrassonografia de Intervenção , Humanos , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , Artéria Femoral/diagnóstico por imagem , Idoso , Fluoroscopia , Pessoa de Meia-Idade , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento , Punções , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Idoso de 80 Anos ou maisRESUMO
Importance: An upper-extremity approach for secondary access during transfemoral transcatheter aortic valve implantation (TAVI) may reduce clinically relevant secondary access site-related bleeding. Objective: To investigate the safety and efficacy of an upper-extremity approach compared with a lower-extremity approach in patients undergoing TAVI. Design, Setting, and Participants: The TAVI XS trial was a randomized clinical trial performed between November 28, 2022, and November 15, 2023, with a 30-day follow-up, in 4 TAVI centers in the Netherlands. Eligibility was determined first, and only those patients with severe aortic stenosis and no contraindication for upper- or lower-extremity secondary access were informed about the study and asked to participate. Intervention: Participants were randomized 1:1 between the upper-extremity approach (radial artery diagnostic access and upper-arm vein for temporary pacing lead placement) and lower-extremity approach (femoral artery diagnostic access and femoral vein for temporary pacing lead placement) for secondary access during TAVI. Main Outcomes and Measures: Primary end point was clinically relevant bleeding (Bleeding Academic Research Consortium type 2, 3, or 5) of the randomized secondary access. Secondary end points included any clinically relevant bleeding, time to mobilization, duration of hospitalization, secondary access failure, and procedural time. Results: Of a total of 324 eligible patients, 238 patients undergoing transfemoral TAVI (mean [SD] age, 79.4 [6.5] years; 150 male [63.0%]; median European System for Cardiac Operative Risk Evaluation II score, 2.2% [IQR, 1.5%-3.5%]) were included. The primary end point occurred in 5 of 119 patients (4.2%) in the upper-extremity group and 16 of 119 (13.4%) in the lower-extremity group (odds ratio [OR], 0.28 [95% CI, 0.10-0.80]; P = .01). Incidence of any clinically relevant bleeding was decreased in the upper-extremity group (25 of 119 [21.0%] vs 41 of 119 [34.5%] patients; OR, 0.51 [95% CI, 0.28-0.91]; P = .02). There was no difference in time to mobilization or duration of hospitalization. Secondary access failure (14 of 119 [11.8%] vs 1 of 119 [0.8%] patients; OR, 15.73 [95% CI, 2.03-121.69]; P = .001) and procedural time (60.0 [IQR, 39.0-88.0; 95% CI, 53.0-70.0] vs 48.0 [IQR, 34.0-64.0; 95% CI, 40.0-55.0] minutes; P = .002) were higher in the upper-extremity cohort. Conclusion and Relevance: In this randomized clinical trial of patients undergoing transfemoral TAVI, the upper-extremity approach for secondary access was associated with less clinically relevant access site-related bleeding compared with the conventional lower-extremity approach and should be considered to reduce periprocedural bleeding complications. Trial Registration: ClinicalTrials.gov Identifier: NCT05672823.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/cirurgia , Extremidade Superior/irrigação sanguínea , Extremidade Superior/cirurgia , Países Baixos , Artéria Radial/cirurgia , Veia FemoralRESUMO
The percutaneous treatment of structural, valvular, and non-valvular heart disease (SHD) is rapidly evolving. The Core Curriculum (CC) proposed by the EAPCI describes the knowledge, skills, and attitudes that define competency levels required by newly trained SHD interventional cardiologists (IC) and provides guidance for training centres. SHD ICs are cardiologists who have received complete interventional cardiology training. They are multidisciplinary team specialists who manage adult SHD patients from diagnosis to follow-up and perform percutaneous procedures in this area. They are competent in interpreting advanced imaging techniques and master planning software. The SHD ICs are expected to be proficient in the aortic, mitral, and tricuspid areas. They may have selective skills in either the aortic area or mitral/tricuspid areas. In this case, they must still have common transversal competencies in the aortic, mitral, and tricuspid areas. Additional SHD domain competencies are optional. Completing dedicated SHD training, aiming for full aortic, mitral, and tricuspid competencies, requires at least 18 months. For full training in the aortic area, with basic competencies in mitral/tricuspid areas, the training can be reduced to 1 year. The same is true for training in the mitral/tricuspid area, with competencies in the aortic area. The SHD IC CC promotes excellence and homogeneous training across Europe and is the cornerstone of future certifications and patient protection. It may be a reference for future CC for national associations and other SHD specialities, including imaging and cardiac surgery.
RESUMO
The percutaneous treatment of structural, valvular, and non-valvular heart disease (SHD) is rapidly evolving. The Core Curriculum (CC) proposed by the EAPCI describes the knowledge, skills, and attitudes that define competency levels required by newly trained SHD interventional cardiologists (IC) and provides guidance for training centres. SHD ICs are cardiologists who have received complete interventional cardiology training. They are multidisciplinary team specialists who manage adult SHD patients from diagnosis to follow-up and perform percutaneous procedures in this area. They are competent in interpreting advanced imaging techniques and master planning software. The SHD ICs are expected to be proficient in the aortic, mitral, and tricuspid areas. They may have selective skills in either the aortic area or mitral/tricuspid areas. In this case, they must still have common transversal competencies in the aortic, mitral, and tricuspid areas. Additional SHD domain competencies are optional. Completing dedicated SHD training, aiming for full aortic, mitral, and tricuspid competencies, requires at least 18 months. For full training in the aortic area, with basic competencies in mitral/tricuspid areas, the training can be reduced to 1 year. The same is true for training in the mitral/tricuspid area, with competencies in the aortic area. The SHD IC CC promotes excellence and homogeneous training across Europe and is the cornerstone of future certifications and patient protection. It may be a reference for future CC for national associations and other SHD specialities, including imaging and cardiac surgery.
RESUMO
AIMS: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement (TAVR) that poses an increased risk of rehospitalization for heart failure and mortality. The aim of this study was to assess the accuracy of haemodynamic indices to predict relevant PVR. METHODS AND RESULTS: In this prospective single-centre clinical trial, four haemodynamic indices of PVR measured during TAVR were assessed for their correlation with gold standard cardiac magnetic resonance (CMR)-derived regurgitant fraction (CMR-RF) at 1 month follow-up: diastolic delta (DD), heart rate-adjusted diastolic delta (HR-DD), aortic regurgitation index (ARI), and aortic regurgitation index ratio (ARI ratio). These haemodynamic indices were analysed for their ability to predict relevant PVR (defined as CMR-RF > 20%) using receiver operating characteristic (ROC) curves with corresponding area under the ROC curves (AUCs). A total of 77 patients were included and had CMR performed 41 ± 14 days after TAVR. Mean CMR-RF was 12.4 ± 9.3%. Fifteen (19.5%) patients had CMR-RF > 20%. DD had the best correlation with CMR-RF and the highest AUC to predict relevant PVR (0.82; 95% CI, 0.72-0.92), followed by HR-DD (AUC 0.78; 95% CI, 0.67-0.89), ARI (AUC 0.78; 95% CI, 0.66-0.89), and ARI ratio (AUC 0.65; 95% CI, 0.49-0.81). The optimal cut-off value for DD was 32 mmHg, with sensitivity of 69% and specificity of 77% in predicting relevant PVR. CONCLUSION: DD measured during TAVR best predicts relevant PVR. Correction for heart rate (HR-DD) or systolic blood pressure (ARI, ARI ratio) did not improve this predictive value.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Espectroscopia de Ressonância Magnética/efeitos adversos , Estudos Prospectivos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
BACKGROUND: Left ventricular ejection fraction (LVEF) demonstrates limited prognostic value for post-transcatheter aortic valve replacement (TAVR) outcomes. Evidence regarding the potential role of left ventricular global longitudinal strain (LV-GLS) in this setting is inconsistent. OBJECTIVES: The aim of this systematic review and meta-analysis of aggregated data was to evaluate the prognostic value of preprocedural LV-GLS for post-TAVR-related morbidity and mortality. METHODS: The authors searched PubMed, Embase, and Web of Science for studies investigating the association between preprocedural 2-dimensional speckle-tracking-derived LV-GLS and post-TAVR clinical outcomes. An inversely weighted random effects meta-analysis was adopted to investigate the association between LV-GLS vs primary (ie, all-cause mortality) and secondary (ie, major cardiovascular events [MACE]) post-TAVR outcomes. RESULTS: Of the 1,130 identified records, 12 were eligible, all of which had a low-to-moderate risk of bias (Newcastle-Ottawa scale). On average, 2,049 patients demonstrated preserved LVEF (52.6% ± 1.7%), but impaired LV-GLS (-13.6% ± 0.6%). Patients with a lower LV-GLS had a higher all-cause mortality (pooled HR: 2.01; 95% CI: 1.59-2.55) and MACE (pooled odds ratio [OR]: 1.26; 95% CI: 1.08-1.47) risk compared with patients with higher LV-GLS. In addition, each percentage point decrease of LV-GLS (ie, toward 0%) was associated with an increased mortality (HR: 1.06; 95% CI: 1.04-1.08) and MACE risk (OR: 1.08; 95% CI: 1.01-1.15). CONCLUSIONS: Preprocedural LV-GLS was significantly associated with post-TAVR morbidity and mortality. This suggests a potential clinically important role of pre-TAVR evaluation of LV-GLS for risk stratification of patients with severe aortic stenosis. (Prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis undergoing Transcatheter Aortic Valve Implantation: a meta-analysis; CRD42021289626).
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Função Ventricular Esquerda , Prognóstico , Volume Sistólico , Deformação Longitudinal Global , Estudos Retrospectivos , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgiaRESUMO
Background The use of large-bore (LB) arterial access and guiding catheters has been advocated for complex percutaneous coronary intervention. However, the impact of LB transradial access (TRA) and transfemoral access (TFA) on extremity dysfunction is currently unknown. Methods and Results The predefined substudy of the COLOR (Complex Large-Bore Radial PCI) trial aimed to assess upper and lower-extremity dysfunction after LB radial and femoral access. Upper-extremity function was assessed in LB TRA-treated patients by the Quick Disabilities of the Arm, Shoulder, and Hand questionnaire and lower-extremity function in LB TFA-treated patients by the Lower Extremity Functional Scale questionnaire. Extremity pain and effect of access site complications and risk factors on extremity dysfunction was also analyzed. There were 343 patients who completed analyzable questionnaires. Overall, upper and lower-extremity function did not decrease over time when LB TRA and TFA were used for complex percutaneous coronary intervention, as represented by the median Quick Disabilities of the Arm, Shoulder, and Hand score (6.8 at baseline and 2.1 at follow-up, higher is worse) and Lower Extremity Functional Scale score (56 at baseline and 58 at follow-up, lower is worse). Clinically relevant extremity dysfunction occurred in 6% after TRA and 9% after TFA. A trend for more pronounced upper-limb dysfunction was present in female patients after LB TRA (P=0.05). Lower-extremity pain at discharge was significantly higher in patients with femoral access site complications (P=0.02). Conclusions Following LB TRA and TFA, self-reported upper and lower-limb function did not decrease over time in the majority of patients. Clinically relevant limb dysfunction occurs in a small minority of patients regardless of radial or femoral access. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03846752.
Assuntos
Cateterismo Periférico , Intervenção Coronária Percutânea , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Feminino , Artéria Femoral , Humanos , Extremidade Inferior , Dor/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Artéria Radial , Resultado do Tratamento , Extremidade SuperiorRESUMO
INTRODUCTION: Although recently published evidence favours transradial access (TRA) when using large-bore guiding catheters for percutaneous coronary intervention (PCI) of complex coronary lesions, the femoral artery will still be used in a considerate proportion of patients undergoing complex PCI, especially in PCI of chronic total occlusions (CTO). Ultrasound-guided puncture of the femoral artery may reduce clinically relevant access site complications, but robust evidence is lacking up to date. METHODS AND ANALYSIS: A total of 542 patients undergoing complex PCI, defined as PCI of CTO, complex bifurcation, heavy calcified lesion or left main, in which the 7-F or 8-F transfemoral access is required, will be randomised to ultrasound-guided puncture or fluoroscopy-guided puncture. The primary outcome is the incidence of the composite end-point of clinically relevant access site related bleeding and/or vascular complications requiring intervention. Access site complications and major adverse cardiovascular events up to 1 month will also be compared between both groups. ETHICS AND DISSEMINATION: Ethical approval for the study was granted by the local Ethics Committee ('Medisch Ethische Toetsing Commissie Isala Zwolle') for all Dutch sites, 'Comité Medische Ethiek Ziekenhuis Oost-Limburg' for Hospital Oost-Limburg, 'Comité d'éthique CHU-Charleroi-ISPPC' for Centre Hospilatier Universitaire de Charleroi and 'Ethik Kommission de Ärztekammer Nordrhein' for Elisabeth-Krankenhaus). The trial outcomes will be published in peer-reviewed journals of the concerned literature. The ultrasound guided transfemoral access in complex large bore PCI trial has been administered in the ClinicalTrials.gov database, reference number: NCT03846752. REGISTRATION DETAILS: ClinicalTrials.gov identifier: NCT03846752.
Assuntos
Intervenção Coronária Percutânea , Doenças Vasculares , Humanos , Punções , Artéria Femoral , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: Heyde syndrome is the co-occurrence of aortic stenosis and gastrointestinal bleeding secondary to angiodysplasias. Surgical aortic valve replacement effectively reduces bleeding, but the effects of transcatheter aortic valve implantation (TAVI) are largely unknown. This study aimed to describe the reduction of gastrointestinal bleeding in patients with Heyde syndrome after TAVI and to identify the factors associated with rebleeding. METHODS: We enrolled patients with Heyde syndrome from a prospective TAVI registry. Gastrointestinal bleeding episodes were assessed by the Bleeding Academic Research Consortium classification, and cumulative incidence functions were used to calculate cessation rates. Factors potentially associated with rebleeding were analyzed using logistic regression. Differences between Heyde and non-Heyde patients were assessed through a case-cohort study. RESULTS: Between December 2008 and June 2020, 1111 patients underwent TAVI. There were 70 patients with Heyde syndrome (6.3%). In the first year following TAVI, gastrointestinal bleeding ceased in 46 of 70 patients (62% [95% CI, 50%-74%]). Bleeding episodes decreased from 3.2 (95% CI, 2.5-4.2) to 1.6 ([95% CI, 1.2-2.2] P=0.001) and hemoglobin levels increased from 10.3 (95% CI, 10.0-10.8) to 11.3 (95% CI, 10.8-11.6) g/dL (P=0.007). Between 1 and 5 years after TAVI (35 [interquartile range, 21-51] months), 53 of 62 patients (83% [95% CI, 72%-92%]) no longer experienced gastrointestinal bleeding. Paravalvular leakage (≥mild) was associated with rebleeding risk (odds ratio, 3.65 [95% CI, 1.36-9.80]; P=0.010). Periprocedural bleeding was more common in Heyde than in control patients (adjusted odds ratio, 2.55 [95% CI, 1.37-4.73]; P=0.003). CONCLUSIONS: Patients with Heyde syndrome are at increased risk for periprocedural bleeding. Post-TAVI, gastrointestinal bleeding disappears in the majority of patients. Paravalvular leakage may curtail these clinical benefits.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Prospectivos , Fatores de Risco , Síndrome , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has emerged as the preferred management strategy for elderly patients with severe symptomatic aortic valve stenosis. These patients are often at high risk of postoperative delirium (POD), which is associated with morbidity and mortality. Since POD may be prevented in a considerable part of these patients, identification of patients at risk is essential. The aim of current study was to identify geriatric assessment tools associated with delirium after TAVI, and long-term mortality. METHODS: Consecutive patients were preoperatively assessed by a geriatrician between 2012 and 2017. Geriatric assessment tools consisted of cognitive, functional, mobility, and nutritional tests. POD was prospectively assessed during hospitalization after TAVI. Mortality tracking was performed by consulting municipal registries. RESULTS: A total of 511 patients were included. Median age was 80 [76-84] years, 44.8% (n = 229) were male, and 14.1% (n = 72) had a history of POD. Delirium was observed in 66 (12.9%) patients. Impaired mobility was the strongest geriatric assessment tool associated with POD (adjusted odds ratio, 2.1 [1.1-4.2], P = .028) and 2-year mortality (adjusted hazard ratio, 2.5 [1.4-4.5], P = .003). Two-year survival was reduced with more than 10% in patients with impaired mobility before TAVI (79.4% vs 91.4%, P = .013). CONCLUSIONS: This study shows that impaired mobility is currently the best single predictor for POD and 2-year mortality in high-risk patients undergoing TAVI. Prospective multicenter studies are needed to optimize and to further explore the facilitation of routine use of POD predictors in TAVI pathways of care, and subsequent preventive interventions.