Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Case Rep ; 4(6): 336-342, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35495559

RESUMO

Valve-in-valve transcatheter aortic valve replacement for failing surgical bioprosthetic valves becomes troublesome if a stiff vascular prosthesis replaces the ascending aorta. We report the off-label use of a new transcatheter aortic valve for treatment of a patient with a bioprosthetic valve with central regurgitation, a horizontal aorta, and kinking of the aortic prosthesis. (Level of Difficulty: Intermediate.).

2.
JTCVS Open ; 9: 28-38, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36003461

RESUMO

Objective: In this study we aimed to understand the role of interaction of the Medtronic Evolut R transcatheter aortic valve with the ascending aorta (AA) by evaluating the performance of the valve and the pressure recovery in different AA diameters with the same aortic annulus size. Methods: A 26-mm Medtronic Evolut R valve was tested using a left heart simulator in aortic root models of different AA diameter (D): small (D = 23 mm), medium (D = 28 mm), and large (D = 34 mm) under physiological conditions. Measurements of pressure from upstream to downstream of the valve were performed using a catheter at small intervals to comprehensively assess pressure gradient and pressure recovery. Results: In the small AA, the measured peak and mean pressure gradient at vena contracta were 11.5 ± 0.5 mm Hg and 7.8 ± 0.4 mm Hg, respectively, which was higher (P < .01) compared with the medium (8.1 ± 0.4 mm Hg and 5.2 ± 0.4 mm Hg) and large AAs (7.4 ± 1.0 mm Hg and 5.4 ± 0.6 mm Hg). The net pressure gradient was lower for the case with the medium AA (4.1 ± 1.2 mm Hg) compared with the small AA (4.7 ± 0.8 mm Hg) and large AA (6.1 ± 1.4 mm Hg; P < .01). Conclusions: We have shown that small and large AAs can increase net pressure gradient, because of the direct interaction of the Medtronic Evolut R stent with the AA (in small AA) and introducing higher level of turbulence (in large AA). AA size might need to be considered in the selection of an appropriate device for transcatheter aortic valve replacement.

3.
JACC Case Rep ; 3(1): 64-68, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34317470

RESUMO

Transcatheter aortic valve replacement is currently used off-label for noncalcified aortic valve regurgitation and therefore is restricted to selected cases. In this setting we describe a rare complication of Sapien 3 (Edwards Lifesciences, Irvine, California) embolization from the left ventricle to the descending aorta. Given their technical challenges, such procedures require specific considerations and management. (Level of Difficulty: Advanced.).

4.
JTCVS Open ; 6: 41-55.e15, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36003550

RESUMO

Objectives: Atrioventricular conductions disturbances, requiring permanent pacemaker implantation (PPI), represent a potential complication after transcatheter aortic valve implantation (TAVI), However, little is known about the pacemaker dependency after PPI in this patient setting. This systematic review analyses the incidence of PPI, the short-term (1-year) pacing dependency, and predictors for such a state after TAVI. Methods: We performed a systematic search in PUBMED, EMBASE, and MEDLINE to identify potentially relevant literature investigating PPI requirement and dependency after TAVI. Study data, patients, and procedural characteristics were extracted. Odds ratio (OR) with 95% confidence intervals were extracted. Results: Data from 23 studies were obtained that included 18,610 patients. The crude incidence of PPI after TAVI was 17% (range, 8.8%-32%). PPI occurred at a median time of 3.2 days (range, 0-30 days). Pacing dependency at 1-year was 47.5% (range, 7%-89%). Self-expandable prosthesis (pooled OR was 2.14 [1.15-3.96]) and baseline right bundle branch block (pooled OR was 2.01 [1.06-3.83]) showed 2-fold greater risk to maintain PPI dependency at 1 year after TAVI. Conclusions: Although PPI represents a rather frequent event after TAVI, conduction disorders have a temporary nature in almost 50% of the cases with recovery and stabilization after discharge. Preoperative conduction abnormality and type of TAVI are associated with higher PPI dependency at short term.

5.
JTCVS Open ; 6: 26-36, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36003588

RESUMO

Objective: This study sought to investigate the effect of body mass index on outcomes in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation. Methods: A total of 12,381 patients undergoing transfemoral transcatheter aortic valve implantation were divided into body mass index categories: underweight (<18.5 kg/m2), normal weight (18.5-24.9 kg/m2), overweight (25.0-29.9 kg/m2), and obesity (>30 kg/m2). Primary endpoints were differences in 30-day and 1-year all-cause mortality. Secondary endpoints included all other clinical endpoints such as stroke. Univariate and multivariate odds ratios were calculated using logistic and cox regression analyses. Results: Two percent (n = 205) of patients were underweight, 29% (n = 3564) were normal weight, 44% (n = 5460) were overweight, and 25% (n = 3152) were obese. Thirty-day mortality was lower in overweight (5.3%, odds ratio, 0.73; 95% confidence interval, 0.61-0.88; P = .001) and obese patients (5.2%, odds ratio, 0.74; 95% confidence interval, 0.60-0.92; P = .006), but higher in underweight (9.8%, odds ratio, 1.51; 95% confidence interval, 0.92-2.47; P = .010) as compared to normal weight patients (6.9%). After multivariate adjustment, 30-day mortality was not significantly different across body mass index categories. However, 1-year mortality was higher in underweight patients (hazard ratio, 1.52; 95% confidence interval, 1.10-2.09; P = .011). Stroke rates were comparable between body mass index groups. Conclusions: For overweight and obese patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation, there was no 30-day difference in mortality compared with patients with normal weight. However, underweight patients showed higher rates of 1-year mortality after transcatheter aortic valve implantation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA