RESUMO
PURPOSE: This series assessed the clinical and radiographic outcomes of total hip arthroplasty (THA) with femoral shortening osteotomy for the management of patients with Crowe type IV hip dysplasia. METHODS: Only patients with Crowe type IV hip dysplasia who underwent primary THA combined with a subtrochanteric transverse osteotomy with an uncemented monoblock conical stem were included. The clinical and radiographic evaluations were performed before and immediately after surgery, and at last follow-up. The hip function was assessed with the Harris Hip Score (HHS). RESULTS: Seventy-four patients (102 hips) with a mean age of 53.9 (range, 20-83) were evaluated at an average follow-up of 11.3 years (range, 5-25). Stem revision occurred in two (1.9%) cases, with a survivorship of 95.9% (95%IC, 91.9-99.9%) at ten years. The average HHS increased from 44 (range, 15-78) pre-operatively to 90.3 (range, 62-100) at last follow-up (p < 0.001). Osteotomy site non-union and early dislocation were observed in 3.9 and 3.8%, respectively. No cases of nerve palsy were reported. CONCLUSIONS: THA with a monoblock conical stem associated with subtrochanteric transverse osteotomy provides good long-term survival, clinical and radiographic results. It may be considered an effective management of patients with Crowe IV hip dysplasia.
Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Osteotomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Luxação Congênita de Quadril/classificação , Luxação Congênita de Quadril/diagnóstico por imagem , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Adulto JovemRESUMO
BACKGROUND: The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. HYPOTHESIS: The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. MATERIALS AND METHODS: Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. RESULTS: Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. CONCLUSIONS: There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. LEVEL OF EVIDENCE: IV, retrospective study.