Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Arch Psychiatry Clin Neurosci ; 274(2): 343-352, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37532863

RESUMO

BACKGROUND: Prenatal alcohol exposure (PAE) has been linked to severe, adverse child outcomes. However, little is known regarding subclinical outcomes of low/moderate PAE and its longitudinal consequences, especially regarding neurophysiological and neurocognitive development. A newborn biomarker of PAE, meconium ethyl glucuronide (EtG), has been shown to predict cognitive impairments in primary-school-aged children. The current study investigated the ongoing effects of subclinical PAE in adolescence. METHODS: A sample of n = 96 mother-child dyads of the FRAMES/FRANCES cohort were classified into PAE/no PAE using EtG with a 10 ng/g cutoff. Mothers were recruited during pregnancy and children were assessed during primary-school age (M = 7.57, SD = 0.65, range: 6.00-9.92 years) and adolescence (M = 13.26, SD = 0.31, range: 12.79-14.20 years) on three levels: clinical (ADHD rating), neuropsychological (IQ score and performance in a go/nogo task), and neurophysiological (analysis of P3 event-related potentials (ERP) during said go/nogo task). Developmental outcomes and courses following PAE were assessed using rmANCOVAs, controlling for relevant confounders (socioeconomic status (SES), birth weight, and maternal psychopathology). RESULTS: Neurophysiological impairments emerged for exposed children in the form of diminished attentional resource recruiting in childhood and adolescence (reduced go-P3 amplitudes) with no differences in performance. Neuropsychological testing showed a reduced IQ score for both time points with dose-dependent effects in childhood. Clinical ADHD symptoms were not significantly affected. CONCLUSION: Subclinical PAE, as determined by meconium EtG, has negative developmental consequences on cognitive function that persist from childhood to adolescence. These findings suggest that there is no safe limit for alcohol consumption during pregnancy and that more thorough screening of alcohol consumption during pregnancy is necessary for early identification and treatment of at-risk children.


Assuntos
Glucuronatos , Mecônio , Efeitos Tardios da Exposição Pré-Natal , Recém-Nascido , Humanos , Feminino , Adolescente , Gravidez , Criança , Efeitos Tardios da Exposição Pré-Natal/diagnóstico , Etanol , Consumo de Bebidas Alcoólicas/efeitos adversos , Cognição
2.
Epilepsy Behav ; 148: 109454, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37776594

RESUMO

PURPOSE: This study evaluated the impact of a newly established clinic for the diagnosis of pediatric epilepsy in a resource-limited center (Ifakara, Tanzania). METHODS: Patients aged 0-18 years referred to the Pediatric Epilepsy Unit of Saint Francis Referral Hospital were recruited. Demographic and clinical data were collected through Kobo Toolbox and analyzed through a descriptive analysis.. RESULTS: 143 patients were evaluated, and for 48 of them an EEG was recorded (abnormalities were detected in 80.85% of the cases). The diagnosis of epilepsy was confirmed in 87 patients. Focal epilepsy was diagnosed in 57 patients, generalized epilepsy in 24 patients, and forms of unknown onset in 6 patients. Epilepsy was excluded for 9 children. Etiologies included hypoxic-ischemic encephalopathy (39%), central nervous system infections (3.4%), and genetic diseases (3.4%). A specific epilepsy syndrome was diagnosed in 16 patients. 74 patients were under treatment; the most used antiseizure medication (ASM) was phenobarbital (43.36%), followed by carbamazepine (16.08%), sodium valproate (11.19%), phenytoin (2.8%), and lamotrigine (0.7%). Therapeutic changes were proposed to 95 patients, more frequently consisting of withdrawing phenobarbital (39.16%), switching to sodium valproate (27.97%), switching to or adjusting carbamazepine dosage (27.27%), and starting prednisone (2.8%). 76% of the patients with confirmed epilepsy achieved complete seizure freedom at the fourth follow-up consultation. CONCLUSIONS: Our data depicted the epilepsy spectrum and highlighted the prognostic implications of improving the availability of ASMs such as sodium valproate and second- and third-generation ones in resource-limited countries.


Assuntos
Epilepsia , Ácido Valproico , Criança , Humanos , Ácido Valproico/uso terapêutico , Tanzânia/epidemiologia , Epilepsia/diagnóstico , Epilepsia/tratamento farmacológico , Epilepsia/epidemiologia , Anticonvulsivantes/uso terapêutico , Carbamazepina/uso terapêutico , Fenobarbital/uso terapêutico , Benzodiazepinas/uso terapêutico
3.
Philos Trans A Math Phys Eng Sci ; 381(2242): 20210228, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36587822

RESUMO

A predictive model for the electron temperature profile of the H-mode pedestal is described, and its results are compared with the pedestal structure of JET-ILW plasmas. The model is based on a scaling for the gyro-Bohm normalized, turbulent electron heat flux [Formula: see text] resulting from electron temperature gradient (ETG) turbulence, derived from results of nonlinear gyrokinetic (GK) calculations for the steep gradient region. By using the local temperature gradient scale length [Formula: see text] in the normalization, the dependence of [Formula: see text] on the normalized gradients [Formula: see text] and [Formula: see text] can be represented by a unified scaling with the parameter [Formula: see text], to which the linear stability of ETG turbulence is sensitive when the density gradient is sufficiently steep. For a prescribed density profile, the value of [Formula: see text] determined from this scaling, required to maintain a constant electron heat flux [Formula: see text] across the pedestal, is used to calculate the temperature profile. Reasonable agreement with measurements is found for different cases, the model providing an explanation of the relative widths and shifts of the [Formula: see text] and [Formula: see text] profiles, as well as highlighting the importance of the separatrix boundary conditions. Other cases showing disagreement indicate conditions where other branches of turbulence might dominate. This article is part of a discussion meeting issue 'H-mode transition and pedestal studies in fusion plasmas'.

4.
Alcohol Clin Exp Res ; 46(10): 1888-1899, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36031718

RESUMO

BACKGROUND: The serotonin transporter (SERT) mRNA was previously reported to be a quantitative and pathophysiology-based biomarker of heavy drinking in 5HTTLPR:LL genotype-carriers treated with ondansetron. Here, we validated the potential use of SERT mRNA for quantitative prediction of recent alcohol consumption (in the absence of treatment) and compared it with the known biomarkers ethyl glucuronide (EtG) and ethyl sulfate (EtS). METHODS: Binge drinking men and women of European ancestry aged 21 to 65 years were enrolled in a 12-day, in-patient, randomized, double-blind, crossover study, where they were administered three beverage doses (placebo, 0.5 g/kg [0.4 g/kg] ethanol, and 1 g/kg [0.9 g/kg] ethanol for men [women]) individually in three 4-day periods (experiments), separated by minimum 7-day washout period. Diet, sleep, and physical activity were controlled throughout the inpatient experiments. Twenty-nine participants were randomized to receive beverage doses counterbalancing the sequence of treatment and gender within subgroups stratified by SERT genotypes 5HTTLPR:LL+rs25531:AA (LA LA ) versus 5HTTLPR:LS/SS. Peripheral venous blood was collected daily for (1) quantification of SERT mRNA (the primary outcome measure) using qRT-PCR and (2) plasma EtG and EtS levels using tandem mass-spectrometry. RESULTS: The association between administered beverage dose and SERT mRNA from completers of at least one 4-day experiment (N = 18) assessed by a linear mixed model was not statistically significant. Significant positive associations were found with beverage dose and plasma EtG, EtS and EtG/EtS ratio (ß = 5.8, SE = 1.2, p < 0.0001; ß = 1.3, SE = 0.6, p = 0.023; and ß = 3.0, SE = 0.7, p < 0.0001, respectively; the C-statistics for discriminating outcomes were 0.97, 0.8, and 0.92, respectively). Additionally, we observed a sequence effect with a greater placebo effect on SERT mRNA when it was administered during the first experiment (p = 0.0009), but not on EtG/EtS measures. CONCLUSION: The findings do not validate the use of SERT as a biomarker of heavy drinking. Larger and more innovative studies addressing the effects of placebo, race, gender, and response to treatment with serotonergic agents are needed to fully assess the utility of SERT as a biomarker of heavy and binge drinking.


Assuntos
Consumo Excessivo de Bebidas Alcoólicas , Proteínas da Membrana Plasmática de Transporte de Serotonina , Feminino , Humanos , Masculino , Consumo de Bebidas Alcoólicas/genética , Biomarcadores , Estudos Cross-Over , Etanol , Glucuronatos/análise , Ondansetron , RNA Mensageiro/genética , Proteínas da Membrana Plasmática de Transporte de Serotonina/genética , Ésteres do Ácido Sulfúrico/análise , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso
5.
Med J Armed Forces India ; 78(3): 316-321, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35855722

RESUMO

Background: Ethyl glucuronide (EtG) is a phase II metabolite of ethanol and is an upcoming biomarker for recent alcohol intake. Monitoring of alcohol intake in case of alcohol-dependent syndrome is very useful for early intervention and preventing harmful effects. EtG has also been identified as a very useful marker in differentiating antemortem ingestion of alcohol from postmortem production of alcohol. This study was undertaken with an objective of developing a sensitive and specific method for determination of EtG in urine. Methods: Triple quadruple Liquid Chromatography (LC)-Mass Spectrometry (MS) with Electrospray Ionization (ESI) negative mode has been used for developing the multiple reaction monitoring method by using the Polaris 3 C 18-Ether analytical column. A simple sample preparation method was adopted using the Bond Elute Plexa PAX SPE cartridge. The developed method was also tested on actual urine samples from 15 individuals after consumption of 60 and 90 ml of whiskey at different time intervals. Results: A simple method was developed for determination of EtG in urine, with a sensitivity of 100 ppb and a recovery of 75%. Validation of the method on urine samples revealed that EtG could be detected for up to 18 h in individuals who ingested 60 ml of whiskey and up to 24 h in those who ingested 90 ml of whiskey. Conclusion: The simple method was developed for determination of EtG in urine and validated on actual urine samples. This method can now be used in aircraft accident investigation to differentiate postmortem production of alcohol, and the method is also a very useful tool to monitor Alcohol dependent Syndrome (ADS) cases.

6.
Clin Chem Lab Med ; 58(8): 1265-1270, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32112697

RESUMO

Background Urinary ethyl glucuronide (EtG) has emerged as the biomarker of choice for alcohol abstinence monitoring in forensic toxicology and is now used in the listing decision process for liver transplantations (LTs) in the German transplant program. However, EtG analysis in this patient group is challenging due to severely impaired liver function, renal failure, co-morbidities and multidrug regimens. The aim of our study was to evaluate liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based EtG analysis for a precise abstinence monitoring in transplant candidates. Methods EtG and ethyl sulfate (EtS) were analyzed by a commercial LC-MS/MS assay in 1787 spot urine samples of 807 patients (>85% from the Department of Hepatology) using a combination of quantifier and two qualifier mass transitions for each analyte. Influences of bacterial contamination, kidney and liver function were investigated. Results Two hundred and sixty-four urine samples had elevated (≥0.5 mg/L) EtG concentrations when only analyzing one quantifier mass transition. Eleven results (4.2%) were found to be false positive after combining three mass transitions for EtG quantification and verification with parallel analysis of EtS. Decreased kidney function was associated with a significantly higher rate of positive EtG samples. One of the false positive results was caused by bacterial metabolism. Conclusions Multimorbid pre-transplant patients have a high risk of individual analytical disturbances of EtG results obtained by LC-MS/MS. Therefore, EtG and EtS should always be measured by a combination of one quantifier and two qualifiers each and evaluated together.


Assuntos
Consumo de Bebidas Alcoólicas/metabolismo , Cromatografia Líquida/métodos , Glucuronatos/metabolismo , Transplante de Fígado , Síndrome de Abstinência a Substâncias/metabolismo , Espectrometria de Massas em Tandem/métodos , Biomarcadores/metabolismo , Alemanha , Humanos , Testes de Função Renal , Testes de Função Hepática , Masculino , Síndrome de Abstinência a Substâncias/fisiopatologia
7.
Hum Psychopharmacol ; 32(5)2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28685869

RESUMO

INTRODUCTION: The aim of this study was to investigate the usefulness of ethyl glucuronide (EtG) and ethyl sulfate (EtS) as biomarkers of the hangover state. METHODS: Thirty-sixhealthy social drinkers participated in this study, being of naturalistic design. Eighteen participants experience regular hangovers (the hangover group), whereas the other 18 claim to not experience a hangover (the hangover-immune group). On a control day (alcohol-free) day and a post-alcohol day, urine EtG and EtS concentrations were determined and hangover severity assessed. RESULTS: Urinary EtG and EtS concentrations were significantly increased on post-alcohol day compared to the control day (p = .0001). Both EtG and EtS concentrations did not significantly correlate with the overall hangover score, nor with the estimated peak blood alcohol concentrations and number of alcoholic drinks. EtG correlated significantly only with the individual hangover symptom "headache" (p = .033; r = .403). No significant correlations were found with the EtG to EtS ratio. EtG and EtS concentrations significantly correlated with urine ethanol concentrations. CONCLUSIONS: Although urine EtG and EtS concentration did not significantly correlate to estimated peak blood alcohol concentrations or the number of alcoholic drinks consumed, a significant correlation was found with urine ethanol concentration. However, urine EtG and EtS concentrations did not significantly correlate with overall hangover severity.


Assuntos
Transtornos Relacionados ao Uso de Álcool/urina , Glucuronatos/urina , Síndrome de Abstinência a Substâncias/urina , Ésteres do Ácido Sulfúrico/urina , Adolescente , Adulto , Consumo de Bebidas Alcoólicas/sangue , Consumo de Bebidas Alcoólicas/urina , Transtornos Relacionados ao Uso de Álcool/sangue , Biomarcadores/urina , Concentração Alcoólica no Sangue , Feminino , Humanos , Masculino , Síndrome de Abstinência a Substâncias/sangue , Adulto Jovem
8.
Alcohol Clin Exp Res ; 38(7): 2056-65, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24773137

RESUMO

BACKGROUND: The ethanol metabolites, ethyl glucuronide (EtG) and ethyl sulfate (EtS), are biomarkers of recent alcohol consumption that provide objective measures of abstinence. Our goals are to better understand the impact of cutoff concentration on test interpretation, the need for measuring both metabolites, and how best to integrate test results with self-reports in clinical trials. METHODS: Subjects (n = 18) were administered, 1 week apart, 3 alcohol doses calibrated to achieve blood concentrations of 20, 80, and 120 mg/dl, respectively. Urinary EtG/EtS was measured at timed intervals during a 24-hour hospitalization and twice daily thereafter. In addition, participants from 2 clinical trials provided samples for EtG/EtS and drinking histories. Cutoffs for EtG/EtS of 100/50, 200/100, and 500/250 ng/ml were evaluated. RESULTS: Twelve hours following each challenge, EtG was always positive at the 100 and 200 cutoffs, but at 24 hours sensitivity was poor at all cutoffs following the low dose, and poor after 48 hours regardless of dose or cutoff. Similarly, in the clinical trials EtG sensitivity was good for detecting any drinking during the last 24 hours at the 2 lowest cutoffs, but under 40% during the last 24 to 48 hours. Sensitivity was reduced at the 500 ng/ml cutoff. Discrepancies between EtG and EtS were few. Comparison of self-reports of abstinence and EtG-confirmed abstinence indicated underreporting of drinking. CONCLUSIONS: Any drinking the night before should be detectable the following morning with EtG cutoffs of 100 or 200 ng/ml. Twenty-four hours after drinking, sensitivity is poor for light drinking, but good for heavier consumption. At 48 hours, sensitivity is low following 6 drinks or less. Increasing the cutoff to 500 ng/ml leads to substantially reduced sensitivity. Monitoring both EtG and EtS should usually be unnecessary. We recommend EtG-confirmed self-reports of abstinence for evaluation of outcomes in clinical trials.


Assuntos
Ensaios Clínicos Controlados como Assunto , Etanol/administração & dosagem , Etanol/farmacocinética , Glucuronatos/urina , Detecção do Abuso de Substâncias/métodos , Ésteres do Ácido Sulfúrico/urina , Adolescente , Adulto , Biomarcadores/urina , Relação Dose-Resposta a Droga , Etanol/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato , Sensibilidade e Especificidade , Adulto Jovem
9.
Magn Reson Chem ; 52(10): 560-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25142124

RESUMO

Recent discoveries of the role of alkane flexibility in determining liquid-crystal behaviour are surveyed. With the impetus for understanding the alkane conformational problem established, recent model dependent (1)H NMR work on the topic will be reviewed where progress is made but the need to circumvent models eventually becomes evident. A closer look at the rigid basic units of alkanes will provide the way forward where it is shown that the orientational ordering and anisotropic potentials of these molecules dissolved in liquid crystals scale with each other. Once this relationship is established, a series of works using anisotropic and isotropic (1)H NMR spectroscopy to study alkane conformational statistics will be covered, wherein the influence of the gas, isotropic condensed and anisotropic condensed phases will be described.

10.
Front Med (Lausanne) ; 11: 1363012, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38633301

RESUMO

The use of direct alcohol biomarkers (ethylglucuronide and phosphatidylethanol) has recently been implemented in a clinical setting. Due to their low alcohol detection threshold, high sensitivity, and specificity, these tools are very useful in the pre- and post-liver transplantation setting, where the history and physical signs are not always reliable. However, the interpretation of the results can sometimes be misleading and must be integrated into a global clinical evaluation and, more importantly, in the clinical context of each patient. We present here a case report illustrating a false-positive hair ethylglucuronide caused by the application of a capillary gel in an abstinent patient after liver transplantation. This reminds us that even the most accurate laboratory tests must be interpreted with caution.

11.
Drug Test Anal ; 16(1): 65-70, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37162012

RESUMO

The aim was the comparison between the Society of Hair Testing (SoHT) consensus for the use of alcohol markers which powdering hair for the extraction of ethylglucuronide (EtG) in water and extraction using the patented M3 Reagent Test kit on cut hair. Hair samples were cut into small segments and washed twice with methanol and diethyl ether. The SoHT-Consensus entails the extraction of pulverised hair in water. This is obtained by incubation of 25 mg of hair at room temperature overnight and 2 h sonication, even if the overnight incubation is not mandatory. The M3 method entails incubation of 25 mg of cut hair with the M3-Reagent at 100°C for 60 min. After centrifugation, the supernatant is injected into a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Samples (191) were collected in the APSS laboratory in Trento, Italy, between 2021 and 2022. The limit of quantification (LOQ) was set at 5 pg/mg for the pulverised and M3-Reagent methods. Assays showed good linearity above the range of LOQ-300 pg/mg. Precision (within 20%) values were also obtained using both methods. In the Passing-Bablock linear regression, the final regression curve between M3 (y) and the pulverising method (x) showed good agreement; the Bland-Altman analysis did not show any significant bias between the two methods. The M3-Reagent method, due to cut hair use, is easy to perform, saves time and allows for a smaller sample quantity loss with use of nondisposable grinding jars for the ball mill to obtain the extraction of EtG.


Assuntos
Alcoolismo , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cabelo/química , Glucuronatos/análise , Água/análise , Detecção do Abuso de Substâncias/métodos
12.
Drug Test Anal ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38686500

RESUMO

Combined use of alcohol and illicit drugs is a serious health and social problem. In this study, it was examined, whether a relationship between alcohol and drug abuse can be ascertained by comparison of alcohol marker and drug concentrations in hair. In the frame of a social support system for families with parental abuse of illicit drugs, hair samples were analyzed between 2011 and 2022 for methadone, heroin (6-acetylmorphine), cocaine, amphetamine, ecstasy (MDMA), cannabinoids (THC), and the alcohol markers ethyl glucuronide (EtG) and ethyl palmitate (EtPa). For 1314 hair samples from adolescent and adult family members, the hair results show a prevalence of combined occasional or regular drug use and social or abusive alcohol use of 41%-60% except heroin (35%). The drug concentrations were statistically compared in the three categories of abstinence or moderate drinking, social drinking, and alcohol abuse. For the most frequently detected drug cocaine (n = 703), a significant increase of the concentrations with rising alcohol consumption was found. The frequent detection of cocaethylene proved the preferred simultaneous intake of both substances. For THC (n = 489), no significant difference between the alcohol consumer groups was seen. Concerning the less frequently detected methadone (n = 89), 6-acetylmorphine (n = 92), amphetamine (n = 123), and MDMA (n = 105), no clear trend between drug and alcohol marker results was determined. It is concluded that the evaluation of hair results is an appropriate way to study the extent of combined drug-alcohol consumption and complements other studies based on acquisition of consumption data by interview or questionnaire.

13.
Cancers (Basel) ; 16(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38927966

RESUMO

BACKGROUND: The postoperative complication rate is 30-64% among patients undergoing muscle-invasive and recurrent high-risk non-muscle-invasive bladder cancer surgery. Preoperative risky alcohol use increases the risk. The aim was to evaluate the accuracy of markers for identifying preoperative risky alcohol. METHODS: Diagnostic test sub-study of a randomized controlled trial (STOP-OP trial), based on a cohort of 94 patients scheduled for major bladder cancer surgery. Identification of risky alcohol use using Timeline Follow Back interviews (TLFB) were compared to the AUDIT-C questionnaire and three biomarkers: carbohydrate-deficient transferrin in plasma (P-CDT), phosphatidyl-ethanol in blood (B-PEth), and ethyl glucuronide in urine (U-EtG). RESULTS: The correlation between TLFB and AUDIT-C was strong (ρ = 0.75), while it was moderate between TLFB and the biomarkers (ρ = 0.55-0.65). Overall, sensitivity ranged from 56 to 82% and specificity from 38 to 100%. B-PEth showed the lowest sensitivity at 56%, but the highest specificity of 100%. All tests had high positive predictive values (79-100%), but low negative predictive values (42-55%). CONCLUSIONS: Despite high positive predictive values, negative predictive values were weak compared to TLFB. For now, TLFB interviews seem preferable for preoperative identification of risky alcohol use.

14.
Forensic Sci Int ; 363: 112173, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39111057

RESUMO

This study details trends in direct alcohol biomarker concentrations from civil cases within the United Kingdom (UK). Our subject cohort in this study related to family law litigation, where an individual was subject to an alcohol monitoring order by the court. This monitoring was conducted by quantification of alcohol biomarkers Phosphatidlyethanol (PEth) in dried blood spots (DBS) and Ethyl Glucuronide (EtG) and Ethyl Palmitate (EtPa) from hair segments. In total 298 PEth cases predominantly from the South East of England during the period July 2022 to August 2023 were analysed for alcohol biomarkers in DBS and hair. Subjects alcohol intake was classified as abstinence/low alcohol consumption, moderate or excessive alcohol consumption, based on a combination of Society for Hair Testing and PEth Net guidelines. Our results indicate that 33 % of PEth concentrations were consistent with excessive alcohol use (>200 ng/mL DBS), with 36 % consistent with social or moderate alcohol use (20-200 ng/mL DBS). In relation to EtG and EtPa 23 % and 31 % of subjects were classified as excessive alcohol users respectively. This study indicates that DBS sampling of PEth is a more sensitive predictor of alcohol use, in particular, at differentiating between moderate and excessive alcohol use compared to EtG and EtPa testing in hair. The authors suggest that increased frequency in the sampling of PEth in DBS (multiple occasions per month) may provide a more accurate assessment and simplification of the interpretation criteria of alcohol patterns rather than the combined hair testing and DBS sampling that are typically requested by UK courts.


Assuntos
Consumo de Bebidas Alcoólicas , Biomarcadores , Glucuronatos , Glicerofosfolipídeos , Cabelo , Humanos , Glucuronatos/análise , Cabelo/química , Biomarcadores/sangue , Biomarcadores/análise , Masculino , Feminino , Inglaterra , Adulto , Consumo de Bebidas Alcoólicas/legislação & jurisprudência , Glicerofosfolipídeos/sangue , Teste em Amostras de Sangue Seco , Pessoa de Meia-Idade , Adulto Jovem , Detecção do Abuso de Substâncias/métodos , Adolescente , Ácidos Palmíticos
15.
Adv Clin Chem ; 116: 113-181, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37852718

RESUMO

The medical disorders of alcoholism rank among the leading public health problems worldwide and the need for predictive and prognostic risk markers for assessing alcohol use disorders (AUD) has been widely acknowledged. Early-phase detection of problem drinking and associated tissue toxicity are important prerequisites for timely initiations of appropriate treatments and improving patient's committing to the objective of reducing drinking. Recent advances in clinical chemistry have provided novel approaches for a specific detection of heavy drinking through assays of unique ethanol metabolites, phosphatidylethanol (PEth) or ethyl glucuronide (EtG). Carbohydrate-deficient transferrin (CDT) measurements can be used to indicate severe alcohol problems. Hazardous drinking frequently manifests as heavy episodic drinking or in combinations with other unfavorable lifestyle factors, such as smoking, physical inactivity, poor diet or adiposity, which aggravate the metabolic consequences of alcohol intake in a supra-additive manner. Such interactions are also reflected in multiple disease outcomes and distinct abnormalities in biomarkers of liver function, inflammation and oxidative stress. Use of predictive biomarkers either alone or as part of specifically designed biological algorithms helps to predict both hepatic and extrahepatic morbidity in individuals with such risk factors. Novel approaches for assessing progression of fibrosis, a major determinant of prognosis in AUD, have also been made available. Predictive algorithms based on the combined use of biomarkers and clinical observations may prove to have a major impact on clinical decisions to detect AUD in early pre-symptomatic stages, stratify patients according to their substantially different disease risks and predict individual responses to treatment.


Assuntos
Alcoolismo , Humanos , Alcoolismo/diagnóstico , Consumo de Bebidas Alcoólicas/efeitos adversos , Fígado/metabolismo , Biomarcadores , Fatores de Risco , Transferrina/análise , Transferrina/metabolismo , Glucuronatos
16.
Curr Res Toxicol ; 4: 100105, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37102125

RESUMO

In the literature on alcohol use biomarkers, there has been debate as to what a valid and/or utilitarian cut off level should be for various research applications. In this manuscript, we assessed the sensitivity and specificity of multiple cutoff values for phosphatidylethanol (PEth) from bloodspots relative to self-report, the Alcohol Use Disorder Identification Test (AUDIT) scores, and another alcohol use biomarker ethyl glucuronide (EtG) from fingernails in a sample of 222 pregnant women in the Western Cape Province of South Africa. Receiver operating characteristic (ROC) curves were used to assess the area under the curve (AUC) and assess PEth cutoff values of ≥2, ≥4, ≥8, ≥14, and ≥20 nanograms per milliliter (ng/ml). The highest AUC value was attained when PEth was compared to an AUDIT score of 1 or more. Depending on the cutoff used to determine alcohol consumption, PEth identified 47%-70% of the individuals as alcohol-consuming while 62.6%-75.2% were identified by self-reported measures, and 35.6% were identified by EtG. In this sample, sensitivity and accuracy were highest at less stringent PEth cutoffs when compared to self-report, AUDIT score of 1 or more, 5 or more, 8 or more, and EtG ≥ 8 picograms per milligram (pg/mg). For research purposes, less stringent cutoffs, such as PEth ≥ 8 ng/ml, may be considered a valid, positive cutoff for identifying women who consume alcohol during pregnancy in this population. A cutoff of PEth ≥ 20 ng/ml may miss individuals who reported consuming alcohol (false negatives).

17.
Front Chem ; 10: 858205, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35444998

RESUMO

Ethyl glucuronide (EtG) is a minor, non-oxidative ethanol metabolite detectable in several matrices for specific periods of time. In recent years, quantification of EtG in hair has been established as the most reliable biomarker for long-term alcohol consumption, with the Society of Hair Testing offering cut-off values for assessment of both abstinence and heavy drinking. Instrumental constrains and wide inter- and intra-laboratory variability represent the ultimate barriers to widespread acceptance of hair EtG determination in the forensic context. In this study, a new analytical method for hair EtG based on gas chromatographic (GC) separation, electron impact (EI) ionization, and tandem mass spectrometry (MS/MS) detection was developed and validated. At the same time, several parameters for sample pretreatment and instrumental analysis were optimized using real hair samples obtained from different drinking subjects. A full-factorial design-of-experiment approach included procedures for hair washing, pulverization, and extraction. Rigorous multi-step washing proved not to reduce the EtG content extracted in the subsequent sample incubation. Hair pulverization with a ball mill significantly improved the EtG extraction from the keratin matrix and allowed us to reduce the time needed for the subsequent extraction step, without affecting the extraction recovery. The hair extract was derivatized with N-methyl-N-(trimethylsilyl)-trifluoroacetamide. Upon electron impact ionization of the EtG-TMS derivative, triple quadrupole mass analyzers were operated in the selected reaction monitoring (SRM) mode using the fragment m/z 405 as the precursor ion (m/z 410 for the EtG-D5 internal standard), the transitions m/z 405 → 359 and m/z 410 → 359 for quantitation, and m/z 405 → 331 and m/z 405 → 287 for qualification/confirmation, all at 10 V collision energy. The final method was fully validated and then applied to 25 real hair samples. The calibration curve proved linear between 6 and 60 pg/mg. The limit of detection (LOD) was 4 pg/mg. Intra- and inter-assay precision and accuracy tests showed a variability and bias close to 15% or lower over the entire calibration range. The new method is routinely applied in the Italian State Police's toxicology laboratory for hair analyses addressed to exclude excessive alcohol drinking and verify the psycho-physical requirements of the personnel.

18.
Toxics ; 10(11)2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36422890

RESUMO

Ethyl glucuronide (EtG) is a non-volatile, non-oxidative, hydrophilic, and stable ethanol phase II metabolite. EtG is produced through ethanol glucuronidation by UDP-glucuronosyltransferase (UGT), a phase II enzyme. EtG can be extracted from different biological matrices, including keratin ones, such as hair or nails. The purpose of this scoping review is to describe the relationship between EtG levels in hair and some of the most common and frequent pathological conditions and verify whether different reference cut-offs in relation to various pathologies have been identified in the scientific literature. In fact, in-depth knowledge of the influence of pathologies, such as diabetes mellitus, hepatic and renal dysfunction, on EtG production and its storage in keratin matrices would allow a more appropriate interpretation of obtained data and rule out false positives or false negatives. This scoping review is based on bibliographic research carried out on PubMed regarding the quantification of EtG in hair of subjects affected by different pathological conditions. According to the scientific literature, the main and most common pathologies that can affect the concentration of EtG in hair are liver and kidney diseases and diabetes. The EtG quantification analytical data should be interpreted carefully as they may have a great impact in both forensic and clinical contexts.

19.
J Clin Exp Hepatol ; 12(2): 544-550, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35535109

RESUMO

Patients with alcohol-associated liver disease may develop severe forms of presentation of acute-on-chronic liver failure, with a high risk for short-term mortality. Alcoholic hepatitis should be suspected among patients with alcohol-associated liver disease who present with acute-on-chronic liver failure. In this review, we discuss the need and feasibility of liver biopsy in the diagnosis of alcoholic hepatitis and predicting its prognosis among decompensated patients with alcohol-associated liver disease and acute-on-chronic liver failure.

20.
J Clin Exp Hepatol ; 12(6): 1527-1534, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36340306

RESUMO

Alcohol withdrawal syndrome (AWS) is a common condition that is seen in treatment-seeking patients with Alcohol use disorder (AUD) and alcoholic liver disease (ALD). AWS, which typically starts within 4-6 h of the last alcohol use, can range from mild symptoms such as insomnia, tremors, and autonomic hyperactivity to more severe symptoms such as seizures and delirium tremens. Clinical Institute Withdrawal Assessment Scale-Alcohol Revised (CIWA-Ar) is the most commonly used scale to assess AWS in clinical practice. The presence of moderate withdrawal as indicated by a score of more than 8 is an indication for pharmacotherapy. Lorazepam and oxazepam are preferred agents for the management of AWS in the setting of ALD. In severe ALD, benzodiazepines should be used cautiously with monitoring due to the risk of excessive sedation or precipitating hepatic encephalopathy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA