Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38400388

RESUMO

In this work, an evanescent Bragg grating sensor inscribed in a few-mode planar polymer waveguide was integrated into microchannel structures and characterized by various chemical applications. The planar waveguide and the microchannels consisted of epoxide-based polymers. The Bragg grating structure was postprocessed by using point-by-point direct inscription technology. By monitoring the central wavelength shift of the reflected Bragg signal, the sensor showed a temperature sensitivity of -47.75 pm/K. Moreover, the functionality of the evanescent field-based measurements is demonstrated with two application examples: the refractive index sensing of different aqueous solutions and gas-phase hydrogen concentration detection. For the latter application, the sensor was additionally coated with a functional layer based on palladium nanoparticles. During the refractive index sensing measurement, the sensor achieved a sensitivity of 6.5 nm/RIU from air to 99.9% pure isopropyl alcohol. For the gas-phase hydrogen detection, the coated sensor achieved a reproducible concentration detection up to 4 vol% hydrogen. According to the reported experimental results, the integrated Bragg-grating-based waveguide sensor demonstrates high potential for applications based on the lab-on-a-chip concept.

2.
J Microsc ; 290(3): 153-160, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36916012

RESUMO

In this paper, an optical waveguide evanescent field fluorescence microscopy is studied. Based on Maxwell's equation, a seven-layer theoretical analysis model is developed for the evaluation of an optical waveguide excitation fluorescence microscopy. The optical waveguide excitation fluorescence microscopy structure is systematically and comprehensively analysed at the wavelengths of 488, 532 and 646 nm for fluorescent dyes. The analysis results provide some useful suggestions, which will be beneficial to the research of an optical waveguide evanescent field fluorescence microscopy.

3.
Proc Natl Acad Sci U S A ; 117(28): 16143-16148, 2020 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-32601234

RESUMO

Matter's sensitivity to light polarization is characterized by linear and circular polarization effects, corresponding to the system's anisotropy and handedness, respectively. Recent investigations into the near-field properties of evanescent waves have revealed polarization states with out-of-phase transverse and longitudinal oscillations, resulting in trochoidal, or cartwheeling, field motion. Here, we demonstrate matter's inherent sensitivity to the direction of the trochoidal field and name this property trochoidal dichroism. We observe trochoidal dichroism in the differential excitation of bonding and antibonding plasmon modes for a system composed of two coupled dipole scatterers. Trochoidal dichroism constitutes the observation of a geometric basis for polarization sensitivity that fundamentally differs from linear and circular dichroism. It could also be used to characterize molecular systems, such as certain light-harvesting antennas, with cartwheeling charge motion upon excitation.

4.
Sensors (Basel) ; 23(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38139642

RESUMO

As the focus tilts toward online detection methodologies for transformer oil aging, bypassing challenges associated with traditional offline methods, such as sample contamination and misinterpretation, fiber optic sensors are gaining traction due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances that are typical in high-voltage environments. This study delves into the sensitivity analysis of intensity-modulated plastic optical fiber sensors. The investigation encompasses key determinants such as the influence of optical source wavelengths, noise response dynamics, ramifications of varying sensing lengths, and repeatability assessments. Our findings highlight that elongating sensing length detrimentally affects both linearity response and repeatability, largely attributed to a diminished resistance to noise. Additionally, the choice of the optical source wavelength proved to be a critical variable in assessing sensor sensitivity.

5.
Sensors (Basel) ; 23(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37448026

RESUMO

We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the refractive index of analytes. Enlarging the ring resonator size is a solution for amplifying the interactions between the evanescent field and biomolecules to obtain a higher refractive index sensitivity of the attached analytes. However, it requires a large platform of a hundred square millimeters, and 99% of the cavity area would not involve evanescent field sensing. In this report, we demonstrate the novel design of a Si-based S-shaped double-spiral resonator on a silicon-on-insulator substrate for which the cavity size was 41.6 µm × 88.4 µm. The proposed resonator footprint was reduced by 680 times compared to a microring resonator with the same cavity area. The fabricated resonator exposed more sensitive optical characteristics for refractive index biosensing thanks to the enhanced contact interface by a long cavity length of DSR structures. High quality factors of 1.8 × 104 were demonstrated for 1.2 mm length DSR structures, which were more than two times higher than the quality factors of microring resonators. A bulk sensitivity of 1410 nm/RIU was calculated for detecting 1 µL IPA solutions inside a 200 µm wide microchannel by using the DSR cavity, which had more than a 10-fold higher sensitivity than the sensitivity of the microring resonators. A DSR device was also used for the detection of 100 ppm acetone gas inside a closed bottle.


Assuntos
Técnicas Biossensoriais , Refratometria , Silício/química
6.
Sensors (Basel) ; 23(20)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37896633

RESUMO

In this study, a novel technique for the quantification of the human chorionic gonadotropin (hCG) hormone using localized surface plasmons and a tapered optical fiber decorated with gold nanoparticles (Au-NPs) is reported. The tapered optical fiber fabrication process involves stretching a single-mode optical fiber using the flame-brushing system. The waist of the tapered optical fiber reaches a diameter of 3 µm. Decoration of the taper is achieved through the photodeposition of 100 nm Au-NPs using the drop-casting technique and a radiation source emitting at 1550 nm. The presence of the hCG hormone in the sample solutions is verified by Fourier-transform infrared spectroscopy (FTIR), revealing the presence of bands related to functional groups, such as C=O (1630 cm-1), which are associated with proteins and lipids, components of the hCG hormone. Quantification tests for hormone concentrations were carried out by measuring the optical power response of the tapered optical fiber with Au-NPs under the influence of hCG hormone concentrations, ranging from 1 mIU/mL to 100,000 mIU/mL. In the waist of the tapered optical fiber, the evanescent field is amplified because of localized surface plasmons generated by the nanoparticles and the laser radiation through the optical fiber. Experimental results demonstrated a proportional relationship between measured radiation power and hCG concentration, with the optical power response decreasing from 4.45 mW down to 2.5 mW, as the hCG hormone concentration increased from 1 mIU/mL up to 100,000 mIU/mL. Furthermore, the spectral analysis demonstrated a spectral shift of 14.2 nm with the increment of the hCG hormone concentration. The measurement system exhibits promising potential as a sensor for applications in the biomedical and industrial fields.

7.
Chemistry ; 27(69): 17331-17335, 2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34609776

RESUMO

Different cell membrane domains play different roles in many cell processes, and the discrimination of these domains is of considerable importance for the elucidation of cellular functions. However, the strategies available for distinguishing these cell membrane domains are limited. A novel technique called plasmon coupling enhanced micro-spectroscopy and imaging to discriminate basal and lateral membrane domains of a single cell combines the application of an additional plasmonic silver film for surface plasmon (SP) excitation to selectively excite and enhance the basal membranes in the near-field with directional enhanced microscopic imaging and spectroscopy. The SP and critical evanescent fields are induced upon excitation through a silver-coated semitransparent coverslip at the surface plasmon resonance and critical angles, respectively. The basal and lateral membrane domains located within the SP and critical evanescent fields can be selectively excited and distinguished by adjusting the incident angle of laser irradiation. Moreover, the brighter images and more intense spectra of membrane-targeting fluorescence-Raman probes under directional excitation than in conventional EPI mode allow clear identification of the membrane domains.


Assuntos
Corantes Fluorescentes , Ressonância de Plasmônio de Superfície , Diagnóstico por Imagem , Prata , Análise Espectral
8.
Chem Eng J ; 407: 127143, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33013189

RESUMO

Portable devices, which can detect and characterize the individual nanoparticles in real time, are of insignificant interest for early diagnosis, homeland security, semiconductor manufacturing and environmental monitoring. Optical microfibers present a good potential in this field, however, are restricted by the sensitivity limit. This study reports the development of a 3D plasmonic nanointerface, which is made of a Cu-BTC framework supporting Cu3-xP nanocrystals, enhancing the optical microfiber for real-time detection and sizing of single nanoparticles. The Cu3-xP nanocrystals are successfully embedded in the 3D Cu-BTC framework. The localized-surface plasmon resonance is tuned to coincide with the evanescent field of the optical microfiber. The 3D Cu-BTC framework, as the scaffold of nanocrystals, confines the local resonance field on the microfiber with three dimensions, at which the binding of target nanoparticles occurs. Based on the evanescent field confinement and surface enhancement by the nanointerface, the optical microfiber sensor overcomes its sensitivity limit, and enables the detection and sizing of the individual nanoparticles. The compact size and low optical power supply of the sensor confirm its suitability as a portable device for the real-time single-nanoparticle characterization, especially for the convenient evaluation of the ultrafine particles in the environment. This work opens up an approach to overcome the sensitivity limit of the optical microfibers, as long with stimulating the portable real-time single-nanoparticle detection and sizing.

9.
Anal Bioanal Chem ; 412(14): 3317-3349, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32313998

RESUMO

Direct optical detection has proven to be a highly interesting tool in biomolecular interaction analysis to be used in drug discovery, ligand/receptor interactions, environmental analysis, clinical diagnostics, screening of large data volumes in immunology, cancer therapy, or personalized medicine. In this review, the fundamental optical principles and applications are reviewed. Devices are based on concepts such as refractometry, evanescent field, waveguides modes, reflectometry, resonance and/or interference. They are realized in ring resonators; prism couplers; surface plasmon resonance; resonant mirror; Bragg grating; grating couplers; photonic crystals, Mach-Zehnder, Young, Hartman interferometers; backscattering; ellipsometry; or reflectance interferometry. The physical theories of various optical principles have already been reviewed in detail elsewhere and are therefore only cited. This review provides an overall survey on the application of these methods in direct optical biosensing. The "historical" development of the main principles is given to understand the various, and sometimes only slightly modified variations published as "new" methods or the use of a new acronym and commercialization by different companies. Improvement of optics is only one way to increase the quality of biosensors. Additional essential aspects are the surface modification of transducers, immobilization strategies, selection of recognition elements, the influence of non-specific interaction, selectivity, and sensitivity. Furthermore, papers use for reporting minimal amounts of detectable analyte terms such as value of mass, moles, grams, or mol/L which are difficult to compare. Both these essential aspects (i.e., biochemistry and the presentation of LOD values) can be discussed only in brief (but references are provided) in order to prevent the paper from becoming too long. The review will concentrate on a comparison of the optical methods, their application, and the resulting bioanalytical quality.


Assuntos
Técnicas Biossensoriais/instrumentação , Dispositivos Ópticos , Animais , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Humanos , Interferometria/instrumentação , Interferometria/métodos , Luz , Refratometria/instrumentação , Refratometria/métodos , Ressonância de Plasmônio de Superfície/instrumentação , Ressonância de Plasmônio de Superfície/métodos , Transdutores
10.
Anal Bioanal Chem ; 412(14): 3447-3456, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32236656

RESUMO

During recent years, mid-infrared (MIR) spectroscopy has matured into a versatile and powerful sensing tool for a wide variety of analytical sensing tasks. Attenuated total reflection (ATR) techniques have gained increased interest due to their potential to perform non-destructive sensing tasks close to real time. In ATR, the essential component is the sampling interface, i.e., the ATR waveguide and its material properties interfacing the sample with the evanescent field ensuring efficient photon-molecule interaction. Gallium arsenide (GaAs) is a versatile alternative material vs. commonly used ATR waveguide materials including but not limited to silicon, zinc selenide, and diamond. GaAs-based internal reflection elements (IREs) are a new generation of semiconductor-based waveguides and are herein used for the first time in direct spectroscopic applications combined with conventional Fourier transform infrared (FT-IR) spectroscopy. Next to the characterization of the ATR waveguide, exemplary surface reactions were monitored, and trace-level analyte detection via signal amplification taking advantage of surface-enhanced infrared absorption (SEIRA) effects was demonstrated. As an example of real-world relevance, the mycotoxin aflatoxin B1 (AFB1) was used as a model analyte in food and feed safety analysis. Graphical abstract.


Assuntos
Arsenicais/química , Gálio/química , Semicondutores , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Aflatoxina B1/análise , Desenho de Equipamento , Análise de Alimentos/instrumentação , Propriedades de Superfície
11.
Proc Natl Acad Sci U S A ; 114(42): 11087-11091, 2017 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-28973939

RESUMO

We examine the motion of periodically driven and optically tweezed microspheres in fluid and find a rich variety of dynamic regimes. We demonstrate, in experiment and in theory, that mean particle motion in 2D is rarely parallel to the direction of the applied force and can even exhibit elliptical orbits with nonzero orbital angular momentum. The behavior is unique in that it depends neither on the nature of the microparticles nor that of the excitation; rather, angular momentum is introduced by the particle's interaction with the anisotropic fluid and optical trap environment. Overall, we find this motion to be highly tunable and predictable.

12.
Sensors (Basel) ; 20(9)2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-32354093

RESUMO

The evanescent fields along multimode fibers are usually relatively weak. To enhance the sensitivity of the resulting sensors, skew rays have been exploited for their larger number of total internal reflections and their more comprehensive spread over the fiber surface. The uniform distribution of light-matter interactions across the fiber surface facilitates high sensitivity through an increased interaction area, while mitigating the risk of laser-induced coating-material damage and photobleaching. Power-dependent measurements are less susceptible to temperature effects than interferometric techniques, and place loose requirements on the laser source. This review highlights the key developments in this area, while discussing the benefits, challenges as well as future development.

13.
Sensors (Basel) ; 19(18)2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31510108

RESUMO

A sensor for trinitrotoluene (TNT) detection was developed by using a combination of optical micro-ring technology and a receptor coating based on molecularly imprinted sol-gel layers. Two techniques for deposition of receptor layers were compared: Airbrush technology and electrospray ionization. A concentration of less than 5 ppb for TNT in the gas-phase, using electrospray deposition of the receptor layer, was detected. The cross-sensitivities to organic substances and further nitro-based explosives were compared. As a result, the sensitivity to TNT is about one order of magnitude higher in comparison to the explosives 2,4-dinitrotoluene (DNT) or 1,3-dinitrobenzene (DNB) and about four orders of magnitude higher than the organic substances phenol, ethanol, and acetone. The signal response of the sensor is fast, and the compact sensor design enables the deposition of different receptor layers on multiple optical micro-rings on one chip, which allows a more precise analysis and reduction of side effects and false alarms.

14.
Sensors (Basel) ; 19(5)2019 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-30818872

RESUMO

In this paper the concept and design of an integrated optical device featuring evanescent field sensing and spectrometric analysis is presented. The device, termed integrated optics sensing spectrometer (IOSS), consists of a modified arrayed waveguide grating (AWG) which arms are engineered into two sets having different focal points. Half of the arms are exposed to the outer media, while the other half are left isolated, thus the device can provide both sensing and reference spectra. Two reference designs are provided for the visible and near-infrared wavelengths, aimed at the determination of the concentration of known solutes through absorption spectroscopy.

15.
Sensors (Basel) ; 19(17)2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31438601

RESUMO

A portable sensor system for the simultaneous detection of multiple environmentally relevant volatile organic compounds (VOCs) in real seawater based on Fourier transform infrared fiber-optic evanescent wave spectroscopy (FT-IR-FEWS) was developed. A cylindrical silver halide (AgX) fiber with an ethylene/propylene copolymer (E/P-co) coated flattened segment was used as an active optical transducer. The polymer membrane enriches the hydrophobic analytes, while water is effectively excluded from the penetration depth of the evanescent field. Determination of multicomponent mixtures (i.e., 10 VOCs in real-world seawater samples) collected in Arcachon Bay, France revealed a high accuracy and reproducibility with detection limits down to 560 ppb. The measurement showed no significant influence from changing water conditions (e.g., salinity, turbidity, and temperature or other interfering substances). The time constants for 90% saturation of the polymer ranged from 20 to 60 min. The sensor system is capable of being transported for on-site monitoring of environmental pollutants in aqueous matrices with efficient long-term stability, thus showing great potential to be utilized as an early warning system.

16.
Sensors (Basel) ; 19(1)2018 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-30583517

RESUMO

Etched fiber Bragg grating (EFBG)-based sensors are used as evanescent field sensors for refractive index detection. When the fiber thickness is thin and the refractive index sensitivity increases, the number of propagating modes increases, resulting in a spectral enlargement that complicates the interrogation of the sensor. In this work, we present a method to analyze the spectrum of a multimode etched fiber Bragg grating (MMEFBG) in the wavelet domain, which analyzes the amount of spectral density independently from the peak reflectivity value. The proposed interrogation method permits defining the integral of the spectral density as a novel and unconventional estimator. With respect to the conventional estimators based on wavelength shift, this estimator can better exploit the larger amount of information given by the spectral enlargement typical of multimode behavior. Results were obtained by etching an MMEFBG in hydrofluoric acid and using water/sucrose mixtures to evaluate the refractive index sensitivity, validating the interrogation method.

17.
Sensors (Basel) ; 18(8)2018 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-30072611

RESUMO

In this paper, different core structures of microstructured optical fibers (MOFs) for low-finesse Fabry⁻Pérot (FP) sensors are experimentally compared to get the highest sensitivity. These devices are designed for volatile organic compounds (VOCs) measurements. Indium tin oxide (ITO) thin films were deposited by sputtering on the MOFs and different optical fast Fourier transform (FFT) phase responses from the FP were measured for saturated atmospheres of ethanol. It has been demonstrated that the sensitivities of the developed sensors depend strongly on the geometry and the dimensions of the MOF-cores. The sensors show recovery times shorter than 100 s and the baselines are fully recovered after every exposure to ethanol vapors.

18.
Appl Phys B ; 123(1): 48, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-32214689

RESUMO

We discuss and measure the phase shift imposed onto a radially polarized light beam when focusing it onto an 174 Yb + ion. In the derivation of the expected phase shifts, we include the properties of the involved atomic levels. Furthermore, we emphasize the importance of the scattering cross section and its relation to the efficiency for coupling the focused light to an atom. The phase shifts found in the experiment are compatible with the expected ones when accounting for known deficiencies of the focusing optics and the motion of the trapped ion at the Doppler limit of laser cooling (Hänsch and Schawlow in Opt Commun 13:68-69, 1975).

19.
Nano Lett ; 16(12): 7333-7337, 2016 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-27960530

RESUMO

Single-mode optical nanofibers are a central component of a broad range of applications and emerging technologies. Their fabrication has been extensively studied over the past decade, but imaging of the final submicrometer products has been restricted to destructive or low-precision techniques. Here, we demonstrate an optical scattering-based scanning method that uses a probe nanofiber to locally scatter the evanescent field of a sample nanofibre. The method does not damage the sample nanofiber and is easily implemented by only using the same equipment as in a standard fiber-puller setup. We demonstrate the subnanometer radial resolution at video rates (0.7 nm in 10 ms) on single mode nanofibers, allowing for a complete high-precision profile to be obtained within minutes of fabrication. The method thus enables nondestructive, fast, and precise characterization of optical nanofibers, with applications ranging from optical sensors and cold atom traps to nonlinear optics.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38934269

RESUMO

Nowadays, volatile organic compound (VOC) detection is imperative to ensure environmental safety in industry and indoor environments, as well as to monitor human health in medical diagnosis. Gas sensors with the best sensor response, selectivity, and stability are in high demand. Simultaneously, the advancement of nanotechnology facilitates novel nanomaterial-based gas sensors with superior sensor characteristics and low power consumption. Recently, boron nitride, a 2D material, has emerged as an excellent candidate for gas sensing and demonstrated exceptional sensing characteristics for new-generation gas sensing devices. Herein, ultrathin porous boron nitride nanosheets (BNNSs) with large lateral sizes were synthesized using a facile synthesis approach, and their material characteristics were investigated utilizing a variety of analytical techniques, including X-ray diffraction, Fourier transform infrared spectroscopy, ultraviolet spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy. A BNNS-coated cladding-modified fiber optic sensor (FOS) probe was prepared and employed for VOC (ammonia, ethanol, and acetone) sensing across concentrations varying from 0 to 300 ppm. The BNNSs-coated FOS demonstrated better selectivity toward 300 ppm ammonia, and specifically annealed BNNSs displayed a maximum sensor response of 55% along with a response/recovery times of 15 s/34 s compared to its counterparts. The superior ammonia sensing performances could be attributed to the formation of ultrathin nanosheets and a porous surface with slit-like features in hexagonal boron nitride.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA