Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 445
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 92(6): 2491-2505, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39155401

RESUMO

PURPOSE: To develop a novel framework to improve the visualization of distal arteries in arterial spin labeling (ASL) dynamic MRA. METHODS: The attenuation of ASL blood signal due to the repetitive application of excitation RF pulses was minimized by splitting the acquisition volume into multiple thin 2D (M2D) slices, thereby reducing the exposure of the arterial blood magnetization to RF pulses while it flows within the brain. To improve the degraded vessel visualization in the slice direction due to the limited minimum achievable 2D slice thickness, a super-resolution (SR) convolutional neural network (CNN) was trained by using 3D time-of-flight (TOF)-MRA images from a large public dataset. And then, we applied domain transfer from 3D TOF-MRA to M2D ASL-MRA, while avoiding acquiring a large number of ASL-MRA data required for CNN training. RESULTS: Compared to the conventional 3D ASL-MRA, far more distal arteries were visualized with higher signal intensity by using M2D ASL-MRA. In general, however, the vessel visualization with a conventional interpolation was prone to be blurry and unclear due to the limited spatial resolution in the slice direction, particularly in small vessels. Application of CNN-based SR transferred from 3D TOF-MRA to M2D ASL-MRA successfully addressed such a limitation and achieved clearer visualization of small vessels than conventional interpolation. CONCLUSION: This study demonstrated that the proposed framework provides improved visualization of distal arteries in later dynamic phases, which will particularly benefit the application of this approach in patients with cerebrovascular disease who have slow blood flow.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Redes Neurais de Computação , Marcadores de Spin , Humanos , Angiografia por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Masculino , Adulto , Feminino , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Processamento de Imagem Assistida por Computador/métodos , Circulação Cerebrovascular/fisiologia , Artérias Cerebrais/diagnóstico por imagem , Pessoa de Meia-Idade , Algoritmos
2.
Magn Reson Med ; 92(2): 761-771, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38523590

RESUMO

PURPOSE: This study evaluated the velocity-selective (VS) MRA with different VS labeling modules, including double refocused hyperbolic tangent, eight-segment B1-insensitive rotation, delay alternating with nutation for tailored excitation, Fourier transform-based VS saturation, and Fourier transform-based inversion. METHODS: These five VS labeling modules were evaluated first through Bloch simulations, and then using VSMRA directly on various cerebral arteries of healthy subjects. The relative signal ratios from arterial ROIs and surrounding tissues as well as relative arteria-tissue contrast ratios of different methods were compared. RESULTS: Double refocused hyperbolic tangent and eight-segment B1-insensitive rotation showed very similar labeling effects. Delay alternating with nutation for tailored excitation yielded high arterial signal but with residual tissue signal due to the spatial banding effect. Fourier transform-based VS saturation with half the time of other techniques serves as an efficient nonsubtractive VSMRA method, but the remaining tissue signal still obscured some small distal arteries that were delineated by other subtraction-based VSMRA, allowing more complete cancelation of static tissue. Fourier transform-based inversion produced the highest arterial signal in VSMRA with minimal tissue background. CONCLUSION: This is the first study that angiographically compared five different VS labeling modules. Their labeling characteristics on arteries and tissue and implications for VSMRA and VS arterial spin labeling are discussed.


Assuntos
Artérias Cerebrais , Análise de Fourier , Angiografia por Ressonância Magnética , Humanos , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiologia , Angiografia por Ressonância Magnética/métodos , Adulto , Masculino , Feminino , Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Marcadores de Spin , Angiografia Cerebral/métodos , Circulação Cerebrovascular/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos
3.
Magn Reson Med ; 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39344291

RESUMO

PURPOSE: To develop a highly accelerated non-contrast-enhanced 4D-MRA technique by combining stack-of-stars golden-angle radial acquisition with a modified self-calibrated low-rank subspace reconstruction. METHODS: A low-rank subspace reconstruction framework was introduced in radial 4D MRA (SUPER 4D MRA) by combining stack-of-stars golden-angle radial acquisition with control-label k-space subtraction-based low-rank subspace modeling. Radial 4D MRA data were acquired and reconstructed using the proposed technique on 12 healthy volunteers and 1 patient with steno-occlusive disease. The performance of SUPER 4D MRA was compared with two temporally constrained reconstruction methods (golden-angle radial sparse parallel [GRASP] and GRASP-Pro) at different acceleration rates in terms of image quality and delineation of blood dynamics. RESULTS: SUPER 4D MRA outperformed the other two reconstruction methods, offering superior image quality with a clear background and detailed delineation of cerebrovascular structures as well as great temporal fidelity in blood flow dynamics. SUPER 4D MRA maintained excellent performance even at higher acceleration rates. CONCLUSIONS: SUPER 4D MRA is a promising technique for highly accelerating 4D MRA acquisition without comprising both temporal fidelity and image quality.

4.
NMR Biomed ; 37(4): e5079, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38054247

RESUMO

A technique for combined time-of-flight (TOF) MR angiography (MRA) and quantitative susceptibility mapping (QSM) was developed with key features of standard three-dimensional (3D) TOF acquisitions, including multiple overlapping thin slab acquisition (MOTSA), ramped RF excitation, and venous saturation. The developed triple-echo 3D TOF-QSM sequence enabled TOF-MRA, susceptibility-weighted imaging (SWI), QSM, and R2* mapping. The effects of ramped RF, resolution, flip angle, venous saturation, and MOTSA were studied on QSM. Six volunteers were scanned at 3 T with the developed sequence, conventional TOF-MRA, and conventional SWI. Quantitative comparison of susceptibility values on QSM and normalized arterial and venous vessel-to-background contrasts on TOF and SWI were performed. The ramped RF excitation created an inherent phase variation in the raw phase. A generic correction factor was computed to remove the phase variation to obtain QSM without artifacts from the TOF-QSM sequence. No statistically significant difference was observed between the developed and standard QSM sequence for susceptibility values. However, maintaining standard TOF features led to compromises in signal-to-noise ratio for QSM and SWI, arising from the use of MOTSA rather than one large 3D slab, higher TOF spatial resolution, increased TOF background suppression due to larger flip angles, and reduced venous signal from venous saturation. In terms of vessel contrast, veins showed higher normalized contrast on SWI derived from TOF-QSM than the standard SWI sequence. While fast flowing arteries had reduced contrast compared with standard TOF-MRA, no statistical difference was observed for slow flowing arteries. Arterial contrast differences largely arise from the longer TR used in TOF-QSM over standard TOF-MRA to accommodate additional later echoes for SWI. In conclusion, although the sequence has a longer TR and slightly lower arterial contrast, provided an adequate correction is made for ramped RF excitation effects on phase, QSM may be performed from a multiecho sequence that includes all key TOF features, thus enabling simultaneous TOF-MRA, SWI, QSM, and R2* map computation.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Artérias , Razão Sinal-Ruído , Veias/diagnóstico por imagem
5.
J Magn Reson Imaging ; 59(3): 1045-1055, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37259904

RESUMO

BACKGROUND: Lenticulostriate artery (LSA) obstruction is a potential cause of subcortical infarcts. However, MRI LSA evaluation at 3T is challenging. PURPOSE: To investigate middle cerebral artery (MCA) plaque characteristics and LSA morphology associated with subcortical infarctions in LSA territories using 7-T vessel wall MRI (VW-MRI) and time-of-flight MR angiography (TOF-MRA). STUDY TYPE: Prospective. POPULATION: Sixty patients with 80 MCA atherosclerotic plaques (37 culprit and 43 non-culprit). FIELD STRENGTH/SEQUENCE: 7-T with 3D TOF-MRA and T1-weighted 3D sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) sequences. ASSESSMENT: Plaque distribution (superior, inferior, ventral, or dorsal walls), LSA origin involvement, LSA morphology (numbers of stems, branches, and length), and plaque characteristics (normalized wall index, maximal wall thickness, plaque length, remodeling index, intraplaque hemorrhage, and plaque surface morphology (regular or irregular)) were assessed. STATISTICAL TESTS: Least absolute shrinkage and selection operator regression, generalized estimating equations regression, receiver operating characteristic curve, independent t-test, Mann-Whitney U test, Chi-square test, Fisher's exact test, and intra-class coefficient. A P value <0.05 was considered statistically significant. RESULTS: Plaque irregular surface, superior wall plaque, longer plaque length, LSA origin involvement, fewer LSA stems, and shorter total and average lengths of LSAs were significantly associated with culprit plaques. Multivariable logistic analysis confirmed that LSA origin involvement (OR, 28.51; 95% CI, 6.34-181.02) and plaque irregular surface (OR, 8.32; 95% CI, 1.41-64.73) were independent predictors in differentiating culprit from non-culprit plaques. A combination of LSA origin involvement and plaque irregular surface (area under curve = 0.92; [95% CI, 0.86-0.98]) showed good performance in identifying culprit plaques, with sensitivity and specificity of 86.5% and 86.0%, respectively. DATA CONCLUSION: 7-T VW-MRI and TOF-MRA can demonstrate plaque involvement with LSA origins. MCA plaque characteristics derived from 7-T VW-MRI showed good diagnostic accuracy in determining the occurrence of subcortical infarctions. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.


Assuntos
Artéria Cerebral Média , Placa Aterosclerótica , Humanos , Estudos Prospectivos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Infarto Cerebral , Angiografia por Ressonância Magnética
6.
J Cardiovasc Magn Reson ; 26(2): 101046, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810732

RESUMO

BACKGROUND: Three-dimensional (3D) contrast-enhanced magnetic resonance angiography (CEMRA) is routinely used for vascular evaluation. With existing techniques for CEMRA, diagnostic image quality is only obtained during the first pass of the contrast agent or shortly thereafter, whereas angiographic quality tends to be poor when imaging is delayed to the equilibrium phase. We hypothesized that prolonged blood pool contrast enhancement could be obtained by imaging with a balanced T1 relaxation-enhanced steady-state (bT1RESS) pulse sequence, which combines 3D balanced steady-state free precession (bSSFP) with a saturation recovery magnetization preparation to impart T1 weighting and suppress background tissues. An electrocardiographic-gated, two-dimensional-accelerated version with isotropic 1.1-mm spatial resolution was evaluated for breath-hold equilibrium phase CEMRA of the thoracic aorta and heart. METHODS: The study was approved by the institutional review board. Twenty-one subjects were imaged using unenhanced 3D bSSFP, time-resolved CEMRA, first-pass gated CEMRA, followed by early and late equilibrium phase gated CEMRA and bT1RESS. Nine additional subjects were imaged using equilibrium phase 3D bSSFP and bT1RESS. Images were evaluated for image quality, aortic root sharpness, and visualization of the coronary artery origins, as well as using standard quantitative measures. RESULTS: Equilibrium phase bT1RESS provided better image quality, aortic root sharpness, and coronary artery origin visualization than gated CEMRA (P < 0.05), and improved image quality and aortic root sharpness versus unenhanced 3D bSSFP (P < 0.05). It provided significantly larger apparent signal-to-noise and apparent contrast-to-noise ratio values than gated CEMRA and unenhanced 3D bSSFP (P < 0.05) and provided ninefold better fluid suppression than equilibrium phase 3D bSSFP. Aortic diameter and main pulmonary artery diameter measurements obtained with bT1RESS and first-pass gated CEMRA strongly correlated (P < 0.05). CONCLUSIONS: We found that using bT1RESS greatly prolongs the useful duration of blood pool contrast enhancement while improving angiographic image quality compared with standard CEMRA techniques. Although further study is needed, potential advantages for vascular imaging include eliminating the current requirement for first-pass imaging along with better reliability and accuracy for a wide range of cardiovascular applications.

7.
Neuroradiology ; 66(7): 1203-1212, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38581636

RESUMO

PURPOSE: Endovascular treatment of direct carotid cavernous fistula (DCCF) requires invasive diagnostic cerebral angiography for diagnosis and planning; however, a less invasive modality like magnetic resonance angiography (MRA) can be useful, especially in high-risk cases. This single-centre study evaluated a newer MR angiography (MRA) sequence, silent MRA and the traditional time of flight (TOF) MRA for pre-procedural treatment planning of DCCF. METHODS: All consecutive DCCF patients who underwent TOF, silent MRA and diagnostic cerebral angiography were included in the study. Angiographic features like rent size, location, draining veins and collateral communicating arteries were analysed and compared between the two MRA sequences, with digital subtraction angiography (DSA) as the gold standard. RESULTS: Fifteen patients were included in the study. TOF MRA exhibited better sensitivity (76.9% vs 69.2%) in identifying the rent location, correctly pinpointing the location in 93.3% compared to 73.3% with silent MRA. Both MRA sequences showed good agreement with DSA for primary sac and rent size. TOF MRA correctly identified 86.2% of 210 total venous structures compared to 96% by silent MRA. Silent MRA demonstrated higher sensitivity (90% vs 76%) and accuracy (87.69 vs 94.36) in visualisation of involved veins compared to TOF MRA. CONCLUSION: Arterial characteristics of DCCF like rent location and rent size were better assessed by TOF MRA. Although both MRA identified venous features, silent MRA correlated better with DSA irrespective of the size and proximity to the site of the fistula. Combining both sequences can evaluate various angioarchitectural features of DCCF useful for therapeutic planning.


Assuntos
Angiografia Digital , Fístula Carótido-Cavernosa , Angiografia por Ressonância Magnética , Sensibilidade e Especificidade , Humanos , Masculino , Angiografia por Ressonância Magnética/métodos , Feminino , Fístula Carótido-Cavernosa/diagnóstico por imagem , Pessoa de Meia-Idade , Angiografia Digital/métodos , Adulto , Idoso , Angiografia Cerebral/métodos , Estudos Retrospectivos
8.
Neurosurg Focus ; 56(3): E9, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38428003

RESUMO

OBJECTIVE: The pathogenesis of intracranial dural arteriovenous fistulas (icDAVFs) is controversial. Cerebral vein thrombosis (CVT) and venous hypertension are recognized predisposing factors. This study aimed to evaluate the incidence of association between icDAVF and CVT and describe baseline aggressiveness and clinical outcomes for icDAVFs associated with CVT. The authors also performed a literature review of studies reporting icDAVF associated with CVT. METHODS: Two hundred sixty-three consecutive patients in two university hospitals with confirmed icDAVFs were included. A double-blind imaging review was performed to determine the presence or absence of CVT close or distant to the icDAVF. Location, type (using the Cognard classification), aggressiveness of the icDAVF, clinical presentation, treatment modality, and clinical and/or angiographic outcomes at 6 months were also collected. All prior brain imaging was analyzed to determine the natural history of onset of the icDAVF. RESULTS: Among the 263 included patients, 75 (28.5%) presented with a CVT concomitant to their icDAVF. For 18 (78.3%) of 23 patients with previous brain imaging available, CVT preceding the icDAVF was proven (6.8% of the overall population). Former/active smoking (OR 2.0, 95% CI 1.079-3.682, p = 0.022) and prothrombogenic status (active inflammation or cancer/coagulation trouble) were risk factors for CVT associated with icDAVF (OR 3.135, 95% CI 1.391-7.108, p = 0.003). One hundred eighty-seven patients (71.1%) had a baseline aggressive icDAVF, not linked to the presence of a CVT (p = 0.546). Of the overall population, 11 patients (4.2%) presented with spontaneous occlusion of their icDAVF at follow-up. Seven patients (2.7%) died during the follow-up period. Intracranial DAVF + CVT was not associated with a worse prognosis (modified Rankin Scale score at 3-6 months: 0 [interquartile range {IQR} 0-1] for icDAVF + CVT vs 0 [IQR 0-0] for icDAVF alone; p = 0.055). CONCLUSIONS: This was one of the largest studies focused on the incidence of CVT associated with icDAVF. For 6.8% of the patients, a natural history of CVT leading to icDAVF was proven, corresponding to 78.3% of patients with previous imaging available. This work offers further insights into icDAVF pathophysiology, aiding in identifying high-risk CVT patients for long-term follow-up imaging. Annual imaging follow-up using noninvasive vascular imaging (CT or MR angiography) for a minimum of 3 years after the diagnosis of CVT should be considered in high-risk patients, i.e., smokers and those with prothrombogenic status.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Veias Cerebrais , Trombose Intracraniana , Trombose Venosa , Humanos , Estudos Retrospectivos , Malformações Vasculares do Sistema Nervoso Central/complicações , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/epidemiologia , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/epidemiologia , Prognóstico , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia , Trombose Venosa/terapia , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
Emerg Radiol ; 31(4): 447-453, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38769220

RESUMO

PURPOSE: To evaluate the multisystem factors contributing to redundant neurovascular orders in the ED. METHODS: This was an IRB-approved, retrospective study, performed at a single institution examining a 5-year history of redundant CTA/MRA head and neck (HN) exams performed in the ED for patients with no documented clinical change in mental status/neurological exam necessitating additional imaging. Factors contributing to redundant ordering including provider experience, synchronous order placement, and radiologist recommendations were examined. Additionally, the impact of duplicative imaging in terms of medical cost and ED length of stay was evaluated. RESULTS: 250 patients met inclusion criteria with both CTA/MRA of the HN performed during a single ED encounter (total 500 exams). 190 (76%) redundant exams were not recommended by a radiologist and contributed to an added ED length of stay of 3.6 h on average. Provider experience was not a significant contributing factor. 60 (24%) of redundant exams were recommended by a radiologist and were most frequently CTAs needed to clarify an area of artifact/high-grade stenosis/occlusion on a primary MRA exam. CONCLUSION: Evaluation of contributing factors to redundant CTA/MRA HN exams ordering has highlighted multiple associated factors including provider experience, recommendations by radiologists for clarification of MRA findings, as well as systems processes related to synchronous CTA/MRA order placement.


Assuntos
Angiografia por Tomografia Computadorizada , Serviço Hospitalar de Emergência , Angiografia por Ressonância Magnética , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Procedimentos Desnecessários , Tempo de Internação/estatística & dados numéricos , Angiografia Cerebral
10.
Magn Reson Med ; 90(2): 432-443, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37010811

RESUMO

PURPOSE: To develop an accelerated 3D intracranial time-of-flight (TOF) magnetic resonance angiography (MRA) sequence with wave-encoding (referred to as 3D wave-TOF) and to evaluate two variants: wave-controlled aliasing in parallel imaging (CAIPI) and compressed-sensing wave (CS-wave). METHODS: A wave-TOF sequence was implemented on a 3 T clinical scanner. Wave-encoded and Cartesian k-space datasets from six healthy volunteers were retrospectively and prospectively undersampled with 2D-CAIPI sampling and variable-density Poisson disk sampling. 2D-CAIPI, wave-CAIPI, standard CS, and CS-wave schemes were compared at various acceleration factors. Flow-related artifacts in wave-TOF were investigated, and a set of practicable wave parameters was developed. Quantitative analysis of wave-TOF and traditional Cartesian TOF MRA was performed by comparing the contrast-to-background ratio between the vessel and background tissue in source images, and the structural similarity index measure (SSIM) between the maximum intensity projection images from accelerated acquisitions and their respective fully sampled references. RESULTS: Flow-related artifacts caused by the wave-encoding gradients in wave-TOF were eliminated by properly chosen parameters. Images from wave-CAIPI and CS-wave acquisitions had a higher SNR and better-preserved contrast than traditional parallel imaging (PI) and CS methods. Maximum intensity projection images from wave-CAIPI and CS-wave acquisitions had a cleaner background, with vessels that were better depicted. Quantitative analyses indicated that wave-CAIPI had the highest contrast-to-background ratio, SSIM, and vessel-masked SSIM among the sampling schemes studied, followed by the CS-wave acquisition. CONCLUSION: 3D wave-TOF improves the capability of accelerated MRA and provides better image quality at higher acceleration factors compared to traditional PI- or CS-accelerated TOF, suggesting the potential use of wave-TOF in cerebrovascular disease.


Assuntos
Artefatos , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Aceleração , Voluntários Saudáveis , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos
11.
NMR Biomed ; 36(7): e4901, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36632695

RESUMO

The purpose of the current study was to develop spatially and velocity-selective (SVS) magnetization preparation pulses for noncontrast-enhanced peripheral MR angiography (MRA) to provide comparisons with velocity-selective (VS) MRA with comparison to velocity-selective (VS). VS preparation pulses were designed by concatenating multiple excitation steps, each of which was a combination of a hard RF pulse, VS unipolar gradient pulses, and refocusing RF pulses. SVS preparation pulses were designed by replacing the hard RF pulse with a sinc-shaped RF pulse combined with a symmetric tripolar gradient pulse (which does not perturb the velocity encoding by the VS unipolar gradient pulses). Numerical simulations were performed to verify the intended hybrid excitation selectivity of SVS pulses taking account of tissue relaxation, magnetic field errors, and eddy currents. In vivo experiments were performed in healthy subjects to verify the hybrid excitation selectivity, as well as to demonstrate the visualization of the entire peripheral arteries using six-station protocols. As demonstrated by numerical simulations, SVS preparation yielded a notch-shaped longitudinal magnetization (Mz )-velocity response within the spatial stopband (the same as VS preparation) and preserved the Mz of spins outside the stopband, regardless of its velocity. We confirmed these observations also through in vivo tests with good agreement in normalized arterial and muscle signal intensities. In six-station peripheral MRA experiments, the proposed SVS-MRA yielded significantly higher arterial signal-to-noise ratio (SNR) (51.6 ± 14.3 vs. 38.9 ± 10.9; p < 0.001) and contrast-to-noise ratio (CNR) (41.2 ± 13.0 vs. 31.3 ± 10.5; p < 0.001) compared with VS-MRA. The proposed SVS-MRA improves arterial SNR and CNR compared with VS-MRA by mitigating undesired presaturation of arterial blood upstream the imaging field of view.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Razão Sinal-Ruído
12.
J Magn Reson Imaging ; 57(6): 1815-1818, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36315131

RESUMO

BACKGROUND: Ferumoxytol, an intravenous iron supplement, is commonly used to treat anemia in pregnancy. Ferumoxytol-enhanced magnetic resonance angiography (Fe-MRA) is a viable off-label alternative to gadolinium-enhanced MRA for assessment of pulmonary embolism (PE) in pregnancy. PURPOSE: To describe our clinical experience with Fe-MRA in pregnant women with suspected PE. STUDY TYPE: Retrospective, observational, cohort. POPULATION: A total of 98 Fe-MRA exams (consecutive sample) performed in 94 pregnant women. FIELD STRENGTH/SEQUENCE: A 1.5 T and 3.0 T, 3D T1-weighted MRA. ASSESSMENT: After IRB approval including a waiver of informed consent, electronic health records were reviewed retrospectively for all Fe-MRA exams performed at our institution in pregnant between January, 2017 and March, 2022. The Fe-MRA protocol included 3D-MRA for assessment of pulmonary arteries, and T1-weighted imaging for ancillary findings. Fe-MRA exam duration was measured from image time stamps. Fe-MRA exams were reviewed by three cardiovascular imagers using a 4-point Likert scale for image quality and confidence for PE diagnosis (score 4 = best, 1 = worst), and tabulation of ancillary findings. STATISTICAL TESTS: Continuous data are presented as mean ± standard deviation. The overall image quality and confidence score is given as the mean of three readers. RESULTS: The 98 Fe-MRA exams were performed in 94 pregnant women (age 30 ± 6, range 19-48 years, gestational week 23 ± 10, range 3-38 weeks), with four undergoing two Fe-MRA exams during their pregnancy. Median Fe-MRA exam durration was 8 minutes (interquantile range 6 minutes). Overall image quality score was 3.3 ± 0.9. Confidence score for diagnosing PE was 3.5 ± 0.8. One subject was positive for PE (1/94, 1%); 42 of the 94 (45%) subjects Fe-MRA had ancillary findings including hydronephrosis or pneumonia. CONCLUSION: Ferumoxytol enhanced MRA is a radiation- and gadolinium-free alternative for diagnosis of PE during pregancy. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 5.


Assuntos
Óxido Ferroso-Férrico , Embolia Pulmonar , Gravidez , Humanos , Feminino , Lactente , Angiografia por Ressonância Magnética/métodos , Meios de Contraste , Estudos Retrospectivos , Pulmão , Embolia Pulmonar/diagnóstico por imagem
13.
J Magn Reson Imaging ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37937684

RESUMO

Arterial spin labeling (ASL) is a noninvasive imaging technique that labels the proton spins in arterial blood and uses them as endogenous tracers. Brain perfusion imaging with ASL is becoming increasingly common in clinical practice, and clinical applications of ASL for intracranial magnetic resonance angiography (MRA) have also been demonstrated. Unlike computed tomography (CT) angiography and cerebral angiography, ASL-based MRA does not require contrast agents. ASL-based MRA overcomes most of the disadvantages of time-of-flight (TOF) MRA. Several schemes have been developed for ASL-based MRA; the most common method has been pulsed ASL, but more recently pseudo-continuous ASL, which provides a higher signal-to-noise ratio (SNR), has been used more frequently. New methods that have been developed include direct intracranial labeling methods such as velocity-selective ASL and acceleration-selective ASL. MRA using an extremely short echo time (eg, silent MRA) or ultrashort echo-time (TE) MRA can suppress metal susceptibility artifacts and is ideal for patients with a metallic device implanted in a cerebral vessel. Vessel-selective 4D ASL MRA can provide digital subtraction angiography (DSA)-like images. This review highlights the principles, clinical applications, and characteristics of various ASL-based MRA techniques. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.

14.
J Magn Reson Imaging ; 58(4): 1110-1122, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36757267

RESUMO

BACKGROUND: Bright-blood lumen and black-blood vessel wall imaging are required for the comprehensive assessment of aortic disease. These images are usually acquired separately, resulting in long examinations and potential misregistration between images. PURPOSE: To characterize the performance of an accelerated and respiratory motion-compensated three-dimensional (3D) cardiac MRI technique for simultaneous contrast-free aortic lumen and vessel wall imaging with an interleaved T2 and inversion recovery prepared sequence (iT2Prep-BOOST). STUDY TYPE: Prospective. POPULATION: A total of 30 consecutive patients with aortopathy referred for a clinically indicated cardiac MRI examination (9 females, mean age ± standard deviation: 32 ± 12 years). FIELD STRENGTH/SEQUENCE: 1.5-T; bright-blood MR angiography (diaphragmatic navigator-gated T2-prepared 3D balanced steady-state free precession [bSSFP], T2Prep-bSSFP), breath-held black-blood two-dimensional (2D) half acquisition single-shot turbo spin echo (HASTE), and 3D bSSFP iT2Prep-BOOST. ASSESSMENT: iT2Prep-BOOST bright-blood images were compared to T2prep-bSSFP images in terms of aortic vessel dimensions, lumen-to-myocardium contrast ratio (CR), and image quality (diagnostic confidence, vessel sharpness and presence of artifacts, assessed by three cardiologists on a 4-point scale, 1: nondiagnostic to 4: excellent). The iT2Prep-BOOST black-blood images were compared to 2D HASTE images for quantification of wall thickness. A visual comparison between computed tomography (CT) and iT2Prep-BOOST was performed in a patient with chronic aortic dissection. STATISTICAL TESTS: Paired t-tests, Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), Bland-Altman analysis. A P value < 0.05 was considered statistically significant. RESULTS: Bright-blood iT2Prep-BOOST resulted in significantly improved image quality (mean ± standard deviation 3.8 ± 0.5 vs. 3.3 ± 0.8) and CR (2.9 ± 0.8 vs. 1.8 ± 0.5) compared with T2Prep-bSSFP, with a shorter scan time (7.8 ± 1.7 minutes vs. 12.9 ± 3.4 minutes) while providing a complementary 3D black-blood image. Aortic lumen diameter and vessel wall thickness measurements in bright-blood and black-blood images were in good agreement with T2Prep-bSSFP and HASTE images (<0.02 cm and <0.005 cm bias, respectively) and good intrareader (ICC > 0.96) and interreader (ICC > 0.94) agreement was observed for all measurements. DATA CONCLUSION: iT2Prep-BOOST might enable time-efficient simultaneous bright- and black-blood aortic imaging, with improved image quality compared to T2Prep-bSSFP and HASTE imaging, and comparable measurements for aortic wall and lumen dimensions. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.


Assuntos
Doenças da Aorta , Angiografia por Ressonância Magnética , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Doenças da Aorta/diagnóstico por imagem , Miocárdio , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes
15.
J Magn Reson Imaging ; 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37916957

RESUMO

BACKGROUND: Previous in vitro studies have described sub-linear longitudinal and heightened transverse H2 O relaxivities of gadolinium-based contrast agents (GBCAs) in blood due to their extracellular nature. However, in vivo validation is lacking. PURPOSE: Validate theory describing blood behavior of R1 and R2 * in an animal model. STUDY TYPE: Prospective, animal. ANIMAL MODEL: Seven swine (54-65 kg). FIELD STRENGTH/SEQUENCE: 1.5 T; time-resolved 3D spoiled gradient-recalled echo (SPGR) and quantitative Look-Locker and multi-echo fast field echo sequences. ASSESSMENT: Seven swine were each injected three times with 0.1 mmol/kg intravenous doses of one of three GBCAs: gadoteridol, gadobutrol, and gadobenate dimeglumine. Injections were randomized for rate (1, 2, and 3 mL/s) and order, during which time-resolved aortic 3D SPGR imaging was performed concurrently with aortic blood sampling via an indwelling catheter. Time-varying [GBCA] was measured by mass spectrometry of sampled blood. Predicted signal intensity (SI) was determined from a model incorporating sub-linear R1 and R2 * effects (whole-blood model) and simpler models incorporating linear R1 , with and without R2 * effects. Predicted SIs were compared to measured aortic SI. STATISTICAL TESTS: Linear correlation (coefficient of determination, R2 ) and mean errors were compared across the SI prediction models. RESULTS: There was an excellent correlation between predicted and measured SI across all injections and swine when accounting for the non-linear dependence of R1 and high blood R2 * (regression slopes 0.91-1.04, R2 ≥ 0.91). Simplified models (linear R1 with and without R2 * effects) showed poorer correlation (slopes 0.67-0.85 and 0.54-0.64 respectively, both R2 ≥ 0.89) and higher averaged mean absolute and mean square errors (128.4 and 177.4 vs. 42.0, respectively, and 5506 and 11,419 vs. 699, respectively). DATA CONCLUSION: Incorporating sub-linear R1 and high first-pass R2 * effects in arterial blood models allows accurate SPGR SI prediction in an in vivo animal model, and might be utilized when modeling MR blood SI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 1.

16.
J Magn Reson Imaging ; 58(5): 1521-1530, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36847756

RESUMO

BACKGROUND: The clinical application of coronary MR angiography (MRA) remains limited due to its long acquisition time and often unsatisfactory image quality. A compressed sensing artificial intelligence (CSAI) framework was recently introduced to overcome these limitations, but its feasibility in coronary MRA is unknown. PURPOSE: To evaluate the diagnostic performance of noncontrast-enhanced coronary MRA with CSAI in patients with suspected coronary artery disease (CAD). STUDY TYPE: Prospective observational study. POPULATION: A total of 64 consecutive patients (mean age ± standard deviation [SD]: 59 ± 10 years, 48.4% females) with suspected CAD. FIELD STRENGTH/SEQUENCE: A 3.0-T, balanced steady-state free precession sequence. ASSESSMENT: Three observers evaluated the image quality for 15 coronary segments of the right and left coronary arteries using a 5-point scoring system (1 = not visible; 5 = excellent). Image scores ≥3 were considered diagnostic. Furthermore, the detection of CAD with ≥50% stenosis was evaluated in comparison to reference standard coronary computed tomography angiography (CTA). Mean acquisition times for CSAI-based coronary MRA were measured. STATISTICAL TESTS: For each patient, vessel and segment, sensitivity, specificity, and diagnostic accuracy of CSAI-based coronary MRA for detecting CAD with ≥50% stenosis according to coronary CTA were calculated. Intraclass correlation coefficients (ICCs) were used to assess the interobserver agreement. RESULTS: The mean MR acquisition time ± SD was 8.1 ± 2.4 minutes. Twenty-five (39.1%) patients had CAD with ≥50% stenosis on coronary CTA and 29 (45.3%) patients on MRA. A total of 885 segments on the CTA images and 818/885 (92.4%) coronary MRA segments were diagnostic (image score ≥3). The sensitivity, specificity, and diagnostic accuracy were as follows: per patient (92.0%, 84.6%, and 87.5%), per vessel (82.9%, 93.4%, and 91.1%), and per segment (77.6%, 98.2%, and 96.6%), respectively. The ICCs for image quality and stenosis assessment were 0.76-0.99 and 0.66-1.00, respectively. DATA CONCLUSION: The image quality and diagnostic performance of coronary MRA with CSAI may show good results in comparison to coronary CTA in patients with suspected CAD. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: 2.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Feminino , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Constrição Patológica , Inteligência Artificial , Angiografia Coronária , Sensibilidade e Especificidade
17.
J Magn Reson Imaging ; 57(3): 727-737, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35808987

RESUMO

BACKGROUND: Pulmonary hypertension (PH) contributes to restricted flow through the pulmonary circulation characterized by elevated mean pulmonary artery pressure acquired from invasive right heart catheterization (RHC). MRI may provide a noninvasive alternative for diagnosis and characterization of PH. PURPOSE: To characterize PH via quantification of regional pulmonary transit times (rPTT). STUDY TYPE: Retrospective. POPULATION: A total of 43 patients (58% female); 24 controls (33% female). RHC-confirmed patients classified as World Health Organization (WHO) subgroups 1-4. FIELD STRENGTH/SEQUENCE: A 1.5 T/time-resolved contrast-enhanced MR Angiography (CE-MRA). ASSESSMENT: CE-MRA data volumes were combined into a 4D matrix (3D resolution + time). Contrast agent arrival time was defined as the peak in the signal-intensity curve generated for each voxel. Average arrival times within a vessel region of interest (ROI) were normalized to the main pulmonary artery ROI (t0 ) for eight regions to define rPTT for all subjects. Subgroup analysis included grouping the four arterial and four venous regions. Intraclass correlation analysis completed for reproducibility. STATISTICAL TESTS: Analysis of covariance with age as covariate. A priori Student's t-tests or Wilcoxon rank-sum test; α = 0.05. Results compared to controls unless noted. Significant without listing P value. ICC ran as two-way absolute agreement model with two observers. RESULTS: PH patients demonstrated elevated rPTT in all vascular regions; average rPTT increase in arterial and venous branches was 0.85 ± 0.15 seconds (47.7%) and 1.0 ± 0.18 seconds (16.9%), respectively. Arterial rPTT was increased for all WHO subgroups; venous regions were elevated for subgroups 2 and 4 (group 1, P = 0.86; group 3, P = 0.32). No significant rPTT differences were found between subgroups (P = 0.094-0.94). Individual vessel ICC values ranged from 0.58 to 0.97. DATA CONCLUSION: Noninvasive assessment of PH using standard-of-care time-resolved CE-MRA can detect increased rPTT in PH patients of varying phenotypes compared to controls. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Assuntos
Hipertensão Pulmonar , Feminino , Masculino , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Artéria Pulmonar/diagnóstico por imagem , Meios de Contraste
18.
Childs Nerv Syst ; 39(11): 3249-3254, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37185695

RESUMO

PURPOSE: To evaluate clinical and imaging characteristics of pediatric brain aneurysms. MATERIALS AND METHODS: A retrospective review of 1458 MR angiograms of pediatric patients (≤18 years old) obtained between 2006 and 2021 was performed. A non-infundibular arterial luminal outpouching larger than 1mm in size was identified as an "Intracranial aneurysm." Patient demographics, clinical presentations, and predisposing risk factors, including family history and underlying medical conditions, were reviewed. MRA images were analyzed for aneurysm location, number, maximum diameter, and interval changes on follow-up. RESULTS: Forty-nine (3.3%) patients (30 females, 19 males) with 64 intracranial aneurysms were identified with an average age of 13.71 ± 3.67 years. Eleven (22.4%) patients had multiple aneurysms. An underlying systemic illness was observed in 81.6% (40/49) cases, with sickle cell disease as the most frequent (25/49, 51%) diagnosis. A first-degree family history of intracranial aneurysms was recognized in 36/1458 (2.5%) patients. However, no intracranial aneurysm was found in this group. While 02/49 (4%) patients presented with acute SAH, headache was the most common (16/49, 32.7%) symptom at presentation in unruptured cases. The majority (47/64, 73.4%) of the aneurysms were located in the anterior circulation, with the ICA ophthalmic segment being most frequently (24/47, 51%) involved. Most (54/64, 84.4%) aneurysms were smaller than 4mm in size at the time of diagnosis. At least one follow-up MRA was obtained in 72.3% (34/47) of the unruptured aneurysms cohort. There was no change in the aneurysm size and morphology in 31/34 (91.2 %) patients over an average imaging follow-up of 39.6 months. Three (6%) patients demonstrated an interval increase in the aneurysm size. SAH patients (n=2) and two unruptured aneurysm patients with an interval increase in size were successfully treated with endovascular techniques. CONCLUSION: Female predominance with a higher frequency of small and unruptured intracranial aneurysms was recognized in our cohort. A higher incidence of an underlying systemic illness, especially sickle cell disease, was also noted. Most intracranial aneurysms in children appear to remain stable. However, there seems to be the risk of an aneurysm size increase which warrants regular clinical and imaging follow-up.


Assuntos
Anemia Falciforme , Aneurisma Roto , Aneurisma Intracraniano , Masculino , Humanos , Feminino , Criança , Adolescente , Aneurisma Intracraniano/cirurgia , Fatores de Risco , Estudos Retrospectivos , Encéfalo , Angiografia
19.
Surg Radiol Anat ; 45(10): 1301-1304, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37572148

RESUMO

The temporopolar artery (TPA) originates directly from the sphenoidal segment of the middle cerebral artery (MCA). Its originating from the M1 segment of the MCA as a branch of the anterior temporal artery is not uncommon. However, internal carotid artery origination is a very rare variation of the TPA. Here, we report a very rare case of the variant origin of the TPA and the presence of saccular aneurysm at this origin.


Assuntos
Artéria Carótida Interna , Aneurisma Intracraniano , Humanos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/anormalidades , Artéria Cerebral Média/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico por imagem , Artérias Temporais , Angiografia Cerebral
20.
Ideggyogy Sz ; 76(7-8): 233-244, 2023 07 30.
Artigo em Húngaro | MEDLINE | ID: mdl-37471200

RESUMO

Background and purpose:

In our collaborative project, called MRI First!, every patient arriving with neurological symptoms of acute stroke and without contraindications was examined by MRI. Our aim was to detect the symptomatic lesions, to obtain appropriate information about the brain parenchyma and to analyse parenchymal perfusion and brain vasculature.

. Methods:

The examinations were conduc­ted on a Philips Ingenia 1.5 Tesla scanner with the following protocol: DWI-ADC, FLAIR, T2 FFE/SWI, PWI, and contrast-enhanced MRA. 415 patients were examined between January 2020 and May 2021. 179 patients arrived within-, and 136 patients after 4.5 hours symptoms onset time, while 100 patients had “wake-up” stroke.

. Results:

Within the 4.5 hours group, 81 cases had acute ischemic lesion, 48 of them received reperfusion therapy. Acute ische­mic lesion was found in 64 patients in the wake-up stroke group and in 64 in the 4.5-24 hours group. In these groups 10 and 12 patients obtained reperfusion therapy, respectively. Further 117 cases were considered as stroke mimics, in which cases unnecessary intravenous thrombolysis was avoidable.

. Conclusion:

MRI is accepted as a sensitive diagnostic modality providing detailed information regarding the brain parenchyma, its perfusion and vasculature. Nonetheless, its worldwide utilization in acute stroke is low and further information should be collected on which patient groups would gain the most benefit from acute MR imaging. Our continuous work is aimed at that goal.

.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Imageamento por Ressonância Magnética/métodos , Encéfalo/patologia , Isquemia Encefálica/diagnóstico , Imagem de Difusão por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA