Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Anal Bioanal Chem ; 411(29): 7771-7781, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31667563

RESUMO

While the targeted analysis of mercapturic acid (MA) metabolites in human urine is used to assess exposure to selected chemicals, this compound class has only rarely been addressed in non-target screening utilizing diagnostic neutral loss liquid chromatography tandem mass spectrometry (LC-MS/MS). Additionally, this type of analysis is severely affected by matrix effects (MEs) causing poor comparability of samples and distortion of signal intensities. However, MEs have been neglected in urinary MA non-target screening so far. Therefore, we developed a non-target screening method relying on neutral loss scanning for MAs using post column infusion of an isotope-labelled standard. For signal correction, we synthesized a structural analogue to MAs, N-acetyl-S-methyl-homocysteine-D3, lacking the characteristic neutral loss of the MAs. For method development, 16 structurally different model MA compounds and 20 spiked urine samples were used. Twelve out of the 16 model compounds could be analysed by the developed method. We found severe matrix effects (largely signal suppression) for the spiked model compounds, with only 34% of all peaks' intensities changing by less than a factor of two. This could be compensated by the post column internal standard infusion with now 68% of all peaks' intensities changing by less than a factor of two. For three compounds, an over-compensation was observed resulting in an increase of signal of up to a factor of 16. In the 20 urine samples, altogether 558 native MAs (between 74 and 175 per sample) could be detected after ME compensation. These results indicate that a large number of so far uncharacterized MAs are present in urine, which yield a potential for biomarker discovery and pattern characterisation. Graphical Abstract.


Assuntos
Acetilcisteína/urina , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Acetilcisteína/normas , Homocisteína/análogos & derivados , Homocisteína/urina , Humanos , Padrões de Referência
2.
J Am Soc Mass Spectrom ; 35(3): 590-602, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38379502

RESUMO

Untargeted metabolomics based on reverse phase LC-MS (RPLC-MS) plays a crucial role in biomarker discovery across physiological and disease states. Standardizing the development process of untargeted methods requires paying attention to critical factors that are under discussed or easily overlooked, such as injection parameters, performance assessment, and matrix effect evaluation. In this study, we developed an untargeted metabolomics method for plasma and fecal samples with the optimization and evaluation of these factors. Our results showed that optimizing the reconstitution solvent and sample injection amount was critical for achieving the balance between metabolites coverage and signal linearity. Method validation with representative stable isotopically labeled standards (SILs) provided insights into the analytical performance evaluation of our method. To tackle the issue of the matrix effect, we implemented a postcolumn infusion (PCI) approach to monitor the overall absolute matrix effect (AME) and relative matrix effect (RME). The monitoring revealed distinct AME and RME profiles in plasma and feces. Comparing RME data obtained for SILs through postextraction spiking with those monitored using PCI compounds demonstrated the comparability of these two methods for RME assessment. Therefore, we applied the PCI approach to predict the RME of 305 target compounds covered in our in-house library and found that targets detected in the negative polarity were more vulnerable to the RME, regardless of the sample matrix. Given the value of this PCI approach in identifying the strengths and weaknesses of our method in terms of the matrix effect, we recommend implementing a PCI approach during method development and applying it routinely in untargeted metabolomics.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Metabolômica/métodos , Fezes
3.
J Sep Sci ; 36(13): 2185-95, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23650216

RESUMO

Pesticide residue analysis is an important part of food quality control. Three of the most widely used methods are the DFG S19 (extraction with acetone), the ChemElut method (extraction with methanol), and QuEChERS (quick, easy, cheap, effective, rugged, safe; acetonitrile-based). Despite many developments in the field of sample preparation, matrix effects are still one of the most disturbing problems in routine analysis. In this study, we compare the matrix effects in LC-MS analysis after using these three methods in pesticide analysis. Using postcolumn infusion, we were able to visualize all suppressions over the whole chromatogram in matrix-effect profiles. Recently, we also presented a system for the determination of up to 300 pesticides from various kinds of fruit and vegetables. For the measurement, we injected an aliquot of a raw acetonitrile extract. The subsequent cleanup was carried out fully automated by a multidimensional LC. Matrix compounds and analytes are separated in the first dimension on a hydrophilic interaction LC column. In this study, we also compared this new approach with the classical methods. The matrix-effect profiles showed less suppression with the hydrophilic interaction LC-based cleanup. A final evaluation of the partitioning steps of all methods confirmed the benefits of the chromatographic cleanup approach.


Assuntos
Automação , Cromatografia Líquida/métodos , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos
4.
J Chromatogr A ; 1698: 464001, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37087856

RESUMO

Reliable analysis of ultratrace antibiotics in bacterial cells may become a new means to elucidate the antibacterial mechanism, drug resistance and environmental fate. In this work, an ultrahigh-sensitive, accurate and enhanced liquid chromatography-tandem mass spectrometric method was first developed for chiral separation and detection of racemic closantel, as an antibacterial adjuvant. Optimizing acetonitrile-water-formic acid system that is compatible with mass spectrometry as a mobile phase, the baseline separation of two enantiomers was achieved by using EnantioPak® Y1-R chiral column, and the resolution of the two analytes was more than 1.95. Further adopt the strategy of postcolumn infusion of ammonia, the mobile phase pH was reversed from acidic condition suitable for the optimal chromatographic separation of R- and S-closantel to alkaline, so that closantel could realize efficient electrospray ionization under the preferred negative ion mode. The bacterial cells were subjected to be frozen-cracked, and the analytes were extracted with acetonitrile after clipping the pointed bottom of the Eppendorf tube into a new tube. The method was linear over concentration ranges of 0.5-50 pg/mL (r2≥0.99) for R- and S-closantel. The detection limits of target analytes were all 0.15 pg/mL in bacterial cells. The average recoveries of two enantiomers ranged from 81.2% to 107.8% with relative standard deviations below 15%. The method proposed might be important support for the deep research of the stereoselectivity of biological activity, toxicity and metabolism of closantel enantiomers.


Assuntos
Amônia , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Antibacterianos/toxicidade , Bactérias , Cromatografia Líquida de Alta Pressão/métodos
5.
J Pharm Biomed Anal ; 236: 115640, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-37683372

RESUMO

Prefilled plastic packaging is time- and cost-effective in hospital pharmacy because it prevents waste, preparation errors, dosage errors, microbial contamination and accidents. This packaging mostly includes prefilled syringes (PFS), intravenous (IV) bags and vials intended for long-term storage that can be used for immediate treatment. There is a rising availability in the market for prefilled drug products due to their practical approach. Leachable compounds could be evaluated in hospital pharmacy-prepared prefilled drug solutions. The Pharmacy Department at the Lausanne University Hospital has developed an innovative, highly sensitive, and generic method by postcolumn infusion based on ultrahigh-performance liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) for the analysis of plastic additives in hospital pharmacies. The postcolumn infusion solution was developed with 2% ammonium hydroxide in methanol on a representative set of 30 candidate compounds with different physical-chemical properties, such as log P and molecular structure, to represent the most important categories of additives. The LODs obtained for all compounds ranged from 0.03 to 7.91 ng/mL with linearity up to 250 ng/mL. Through this screening method, plastic additives can be rapidly identified due to the combined use of retention time, exact mass (including isotopic pattern) and MS/MS spectra. In addition, the users can screen for vast categories of plastic additives, including plasticizers, epoxy monomers, antioxidants, UV stabilizers, and others. The screening is facilitated by assessments of a complex in-house-built database for extractable and leachable trace assessment (DELTA), containing 205 compounds for unambiguous identification. Relative response factors were established for all analytes to obtain a semiquantitation of compounds. Moreover, the database also contains valuable estimative toxicology information, which was obtained through calculating their permissible dose exposure threshold; thus, estimative toxicology assessment can be performed for identified compounds in prefilled drug products. This method and the database were applied to a hospital pharmacy-prepared prefilled vancomycin syringe for paediatric use. Ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) was used to prepare the samples for leachable analysis. As a result, 17 plastic additives were formally identified, and their concentrations were estimated. A toxicology assessment was performed by comparing their concentrations with their theoretical PDE thresholds. In conclusion, the prefilled drug solution released a negligible amount of known leachables that appeared to be safe for use in neonates and children.


Assuntos
Serviço de Farmácia Hospitalar , Espectrometria de Massas em Tandem , Recém-Nascido , Humanos , Criança , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Embalagem de Medicamentos/métodos , Cromatografia Líquida de Alta Pressão/métodos
6.
Food Chem ; 173: 897-904, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25466104

RESUMO

An automated, size-exclusion solid phase extraction (SPE)-UPLC-MS/MS protocol without pre-treatment of samples was developed to screen for four mycotoxins (OTA, ZEN, AFB1, and AFM1) in liquid milk and milk powder. Firstly, a mixed macropore-silica gel cartridge was established as a size-exclusion SPE column. The proposed methodology could be a candidate in green analytical chemistry because it saves on manpower and organic solvent. Permanent post-column infusion of mycotoxin standards was used to quantify matrix effects throughout the chromatographic run. Matrix-matched calibration could effectively compensate for matrix effects, which may be caused by liquid milk or milk powder matrix. Recovery of the four mycotoxins in fortified liquid milk was in the range 89-120% and RSD 2-9%. The LOD for the four mycotoxins in liquid milk and milk powder were 0.05-2 ng L(-1) and 0.25-10 ng kg(-1), respectively. The LOQ for the four mycotoxins in liquid milk and milk powder were 0.1-5 ng L(-1) and 0.5-25 ng kg(-1), respectively.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Alimentos/análise , Leite/química , Micotoxinas/química , Micotoxinas/isolamento & purificação , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Bovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA