Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Cardiovasc Dis ; 108(4): 227-34, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25682547

RESUMO

BACKGROUND: The finger-toe pathway could be a good alternative for assessing arterial stiffness conveniently. AIM: To evaluate the accuracy of the pOpmètre®--a new device that measures finger-toe pulse wave velocity (ft-PWV). METHODS: The pOpmètre has two photodiode sensors, positioned on the finger and the toe. Pulse waves are recorded continuously for 20 seconds, and the difference in pulse wave transit time between toe and finger (ft-TT) is calculated. The travelled distance is estimated using subject height. Study 1 compared ft-PWV with carotid-femoral PWV (cf-PWV) obtained by the reference method (SphygmoCor®) in 86 subjects (mean age 53±20 years), including 69 patients with various pathologies and 17 healthy normotensives. Study 2 compared changes in ft-PWV and cf-PWV during a cold pressor test in 10 healthy subjects. Study 3 assessed repeatability in 45 patients. RESULTS: ft-PWV correlated significantly with cf-PWV (R2=0.43; P<0.0001). A better correlation was found in terms of transit time (R2=0.61; P<0.0001). The discrepancy between transit times was related to age. The cold pressor test induced parallel changes in cf-PWV and ft-PWV, with increased aortic stiffness that was reversible during recovery. Intra-session repeatability was very good, with a coefficient of variation of 4.52%. CONCLUSION: The pOpmètre® allows measurement of arterial stiffness in routine clinical practice. The greatest advantages of ft-PWV are simplicity, rapidity, feasibility, acceptability by patients and correct agreement with the reference technique. Further studies are needed to adjust for bias and to validate the pOpmètre in larger populations.


Assuntos
Dedos/irrigação sanguínea , Análise de Onda de Pulso/instrumentação , Dedos do Pé/irrigação sanguínea , Rigidez Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Transtornos Cognitivos/fisiopatologia , Temperatura Baixa , Desenho de Equipamento , Feminino , França , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA