RESUMO
Ultimately, brittle fracture involves breaking atomic bonds. However, we still lack a clear picture of what happens in the highly deformed region around a moving crack tip. Consequently, we still cannot link nanoscale phenomena with the macroscopic toughness of materials. The unsolved challenge is to observe the movement of the crack front at the nanoscale while extracting quantitative information. Here, we address this challenge by monitoring stable crack growth inside a transmission electron microscope. Our analysis demonstrates how phase transformation toughening, previously thought to be effective at the microscale and above, promotes crack deflection at the nanolevel and increases the fracture resistance. The work is a first step to help connecting the atomistic and continuous view of fracture in a way that can guide the design of the next generation of strong and tough materials demanded by technologies as diverse as healthcare, energy generation, or transport.
RESUMO
In this work, we have found that a prenotched double-network (DN) hydrogel, when subjected to tensile loading in a pure-shear geometry, exhibits intriguing stick-slip crack dynamics. These dynamics synchronize with the oscillation of the damage (yielding) zone at the crack tip. Through manipulation of the loading rate and the predamage level of the brittle network in DN gels, we have clarified that this phenomenon stems from the significant amount of energy dissipation required to form the damage zone at the crack tip, as well as a kinetic contrast between the rapid crack extension through the yielding zone (slip process) and the slow formation of a new yielding zone controlled by the external loading rate (stick process).
RESUMO
Pore structures provide extra freedoms for the design of porous media, leading to desirable properties, such as high catalytic rate, energy storage efficiency, and specific strength. This unfortunately makes the porous media susceptible to failure. Deep understanding of the failure mechanism in microstructures is a key to customizing high-performance crack-resistant porous media. However, solving the fracture problem of the porous materials is computationally intractable due to the highly complicated configurations of microstructures. To bridge the structural configurations and fracture responses of random porous media, a unique generative deep learning model is developed. A two-step strategy is proposed to deconstruct the fracture process, which sequentially corresponds to elastic deformation and crack propagation. The geometry of microstructure is translated into a scalar of elastic field as an intermediate variable, and then, the crack path is predicted. The neural network precisely characterizes the strong interactions among pore structures, the multiscale behaviors of fracture, and the discontinuous essence of crack propagation. Crack paths in random porous media are accurately predicted by simply inputting the images of targets, without inputting any additional input physical information. The prediction model enjoys an outstanding performance with a prediction accuracy of 90.25% and possesses a robust generalization capability. The accuracy of the present model is a record so far, and the prediction is accomplished within a second. This study opens an avenue to high-throughput evaluation of the fracture behaviors of heterogeneous materials with complex geometries.
RESUMO
Soft materials fail by crack propagation under external loads. While fracture toughness of a soft material can be enhanced by orders of magnitude, its fatigue threshold remains insusceptible. In this work, we demonstrate a crack tip softening (CTS) concept to simultaneously improve the toughness and threshold of a single polymeric network. Polyacrylamide hydrogels have been selected as a model material. The polymer network is cured by two kinds of crosslinkers: a normal crosslinker and a light-degradable crosslinker. We characterize the pristine sample and light-treated sample by shear modulus, fracture toughness, fatigue threshold, and fractocohesive length. Notably, we apply light at the crack tip of a sample so that the light-sensitive crosslinkers degrade, resulting in a CTS sample with a softer and elastic crack tip. The pristine sample has a fracture toughness of 748.3 ± 15.19 J/m2 and a fatigue threshold of 9.3 J/m2. By comparison, the CTS sample has a fracture toughness of 2,774.6 ± 127.14 J/m2 and a fatigue threshold of 33.8 J/m2. Both fracture toughness and fatigue threshold have been enhanced by about four times. We attribute this simultaneous enhancement to stress de-concentration and elastic shielding at the crack tip. Different from the "fiber/matrix composite" concept and the "crystallization at the crack tip" concept, the CTS concept in the present work provides another option to simultaneously enhance the toughness and threshold, which improves the reliability of soft devices during applications.
RESUMO
Electric vehicles (EVs) are imposing ever-challenging standards on the lifetime and safety of lithium-ion batteries (LIBs); consequently, real-time nondestructive monitoring of battery cell degradation is highly desired. Unfortunately, high-nickel (Ni) layered oxides, the preferred LIB cathodes for EVs, undergo performance degradation originating from microcrack formation during cycling. Entropymetry is introduced as a real-time analytic tool for monitoring the evolution of microcracks in these cathodes along the state of charge. The entropy change of the layered cathode is associated with the lattice configuration and reflects the structural heterogeneity relevant to the evolution of these microcracks. The structural heterogeneity was correlated with peak broadening in in-situ X-ray diffractometry while varying the experimental conditions that affect crack formation such as the upper cutoff voltage during charging and the Ni-content of the active material. Entropymetry, proposed here as a nondestructive diagnostic tool, can contribute greatly to the safe and reliable operation of LIBs for EVs.
RESUMO
Lattice structures, comprising nodes and struts arranged in an array, are renowned for their lightweight and unique mechanical deformation characteristics. Previous studies on lattice structures have revealed that failure often originates from stress concentration points and spreads throughout the material. This results in collapse failure, similar to the accumulation of damage at defects in metallic crystals. Here the precipitation hardening mechanism found in crystalline materials is employed to deflect the initial failure path, through the strategic placement of strengthening units at stress concentration points using the finite element method. Both the mesostructure, inspired by the arrangement of crystals, and the inherent microstructure of the base materials have played crucial roles in shaping the mechanical properties of the macro-lattices. As a result, a groundbreaking multiscale hierarchical design methodology, offering a spectrum of design concepts for engineering materials with desired properties is introduced.
RESUMO
Intragranular cracking within the material structure of Ni-rich (LiNixCoyMn1 - x - y, x ≥0.9) cathodes greatly threatens cathode integrity and causes capacity degradation, yet its atomic-scale incubation mechanism is not completely elucidated. Notably, the physicochemical properties of component elements fundamentally determine the material structure of cathodes. Herein, a diffusion-controlled incubation mechanism of intragranular cracking is unraveled, and an underlying correlation model with Co element is established. Multi-dimensional analysis reveals that oxygen vacancies appear due to the charge compensation from highly oxidizing Co ions in the deeply charged state, driving the transition metal migration to Li layer and layered to rock-salt phase transition. The local accumulation of two accompanying tensile strains collaborates to promote the nucleation and growth of intragranular cracks along the fragile rock-salt phase domain on (003) plane. This study focuses on the potential risks posed by Co to the architectural and thermal stability of Ni-rich cathodes and is dedicated to the compositional design and performance optimization of Ni-rich cathodes.
RESUMO
Lithium-ion batteries (LIBs) has been developed over the last three decades. Increased amount of silicon (Si) is added into graphite anode to increase the energy density of LIBs. However, the amount of Si is limited, due to its structural instability and poor electronic conductivity so a novel approach is needed to overcome these issues. In this work, the synthesized chromium silicide (CrSi2) doped Si nanoparticle anode material achieves an initial capacity of 1729.3 mAh g-1 at 0.2C and retains 1085 mAh g-1 after 500 cycles. The new anode also shows fast charge capability due to the enhanced electronic conductivity provided by CrSi2 dopant, delivering a capacity of 815.9 mAh g-1 at 1C after 1000 cycles with a capacity degradation rate of <0.05% per cycle. An in situ transmission electron microscopy is used to study the structural stability of the CrSi2-doped Si, indicating that the high control of CrSi2 dopant prevents the fracture of Si during lithiation and results in long cycle life. Molecular dynamics simulation shows that CrSi2 doping optimizes the crack propagation path and dissipates the fracture energy. In this work a comprehensive information is provided to study the function of metal ion doping in electrode materials.
RESUMO
To effectively solve the challenges of rapid capacity decay and electrode crushing of silicon-carbon (Si-C) anodes, it is crucial to carefully optimize the structure of Si-C active materials and enhance their electron/ion transport dynamic in the electrode. Herein, a unique hybrid structure microsphere of Si/C/CNTs/Cu with surface wrinkles is prepared through a simple ultrasonic atomization pyrolysis and calcination method. Low-cost nanoscale Si waste is embedded into the pyrolysis carbon matrix, cleverly combined with the flexible electrical conductivity carbon nanotubes (CNTs) and copper (Cu) particles, enhancing both the crack resistance and transport kinetics of the entire electrode material. Remarkably, as a lithium-ion battery anode, the fabricated Si/C/CNTs/Cu electrode exhibits stable cycling for up to 2300 cycles even at a current of 2.0 A g-1, retaining a capacity of ≈700 mAh g-1, with a retention rate of 100% compared to the cycling started at a current of 2.0 A g-1. Additionally, when paired with an NCM523 cathode, the full cell exhibits a capacity of 135 mAh g-1 after 100 cycles at 1.0 C. Therefore, this synthesis strategy provides insights into the design of long-life, practical anode electrode materials with micro/nano-spherical hybrid structures.
RESUMO
Certain legumes provide a special pathway for rhizobia to invade the root and develop nitrogen-fixing nodules, a process known as lateral root base (LRB) nodulation. This pathway involves intercellular infection at the junction of the lateral roots with the taproot, leading to nodule formation in the lateral root cortex. Remarkably, this LRB pathway serves as a backbone for various adaptative symbiotic processes. Here, we describe different aspects of LRB nodulation and highlight directions for future research to elucidate the mechanisms of this as yet little known but original pathway that will help in broadening our knowledge on the rhizobium-legume symbiosis.
Assuntos
Fabaceae , Nodulação , Rhizobium , Simbiose , Nodulação/fisiologia , Fabaceae/microbiologia , Fabaceae/fisiologia , Simbiose/fisiologia , Rhizobium/fisiologia , Raízes de Plantas/microbiologia , Raízes de Plantas/fisiologia , Nódulos Radiculares de Plantas/microbiologia , Nódulos Radiculares de Plantas/fisiologia , Fixação de Nitrogênio/fisiologiaRESUMO
Distal ulna locking bone plates (DLBPs) are commonly employed in the treatment of distal ulna fractures. However, commercially available metallic bone plates experience stress shielding and lack corrosion resistance. Poly lactic acid (PLA) is highly favored biopolymer due to its biocompatible and bioabsorbable nature with human tissues. The use of additive layer manufacturing (ALM) is gaining attention for creating customized implants with intricate structures tailored to patient autonomy. ALM-based PLA bone plates must provide high resistance against impact and torsional forces, necessitating the adjustment of printing process parameters. This study focuses on examining the influence of key printing parameters, on the impact strength and torque-withstanding capability of DLBPs. Experimental results, along with microscopic images, reveal that an increase in infill density (IF) and wall thickness imparts strong resistance to layers against crack propagation under impact and torsional loads. On the contrary, an increase in layer height and printing speed leads to delamination and early fracture of layers during impact and torsional testing. IF significantly contributes to improving the impact strength and torque-withstanding capability of DLBPs by 70.53% and 80.65%, respectively. The study highlights the potential of the ALM technique in developing DLBPs with sufficient mechanical strength for biomedical applications.
Assuntos
Placas Ósseas , Teste de Materiais , Biopolímeros/química , Poliésteres/química , Materiais Biocompatíveis/química , Humanos , Estresse Mecânico , Impressão Tridimensional , Torque , Ortopedia/métodosRESUMO
Drugs have been classified as fast, moderate, and poor crystallizers based on their inherent solid-state crystallization tendency. Differential scanning calorimetry-based heat-cool-heat protocol serves as a valuable tool to define the solid-state crystallization tendency. This classification helps in the development of strategies for stabilizing amorphous drugs. However, microscopic characteristics of the samples were generally overlooked during these experiments. In the present study, we evaluated the influence of microscopic cracks on the crystallization tendency of a poorly water-soluble model drug, celecoxib. Cracks developed in the temperature range of 0-10 °C during the cooling cycle triggered the subsequent crystallization of the amorphous phase. Nanoindentation study suggested minimal differences in mechanical properties between samples, although the cracked sample showed relatively inhomogeneous mechanical properties. Nuclei nourishment experiments suggested crack-assisted nucleation, which was supported by Raman data that revealed subtle changes in intermolecular interactions between cracked and uncracked samples. Celecoxib has been generally classified as class II, i.e., a drug with moderate crystallization tendency. Interestingly, classification of amorphous celecoxib may change depending on the presence or absence of cracks in the amorphous sample. Hence, subtle events such as microscopic cracks should be given due consideration while defining the solid-state crystallization tendency of drugs.
Assuntos
Água , Cristalização , Celecoxib/química , Estabilidade de Medicamentos , Transição de Fase , Varredura Diferencial de Calorimetria , SolubilidadeRESUMO
RESEARCH QUESTION: Embryo blastomeres and the zona pellucida are occasionally damaged during vitrification; is this a result of crack-induced mechanical damage in the glass state, caused by external bending of the device? DESIGN: A stereomicroscope was used to observe external bending-induced cracks in a cryoprotectant. Thereafter, 309 human cleavage-stage embryos derived from abnormally fertilized eggs were used to assess embryo damage under two external bending conditions: forward bending and backward bending, with three bending degrees applied. Three distinct embryo positions were used to examine the correlation between bending and embryo damage. Damage was assessed by looking at blastomere lysis rates, and overall rates of damaged and surviving embryos. RESULTS: A series of parallel cracks were identified in the cryoprotectant used for external bending, which led to damage to the embryo blastomeres. Compared with forward bending and control, the embryos were found to be more easily damaged by backward bending, indicated by significantly higher blastomere lysis and embryo damage rates, and lower embryo survival rate of backward bending than forward bending (P < 0.001). The degree of embryo damage also increased as the degree of external forces increased. Embryo position correlated with degree of embryo damage. CONCLUSIONS: Cryoprotectant crack-induced damage was identified as the cause of embryo damage. Mechanical damage to the glass state occurs because of improper external bending of the cryodevice strip in liquid nitrogen during vitrification. To prevent damage, bending of the strip should be avoided and the embryos should be placed near the tip of the strip.
Assuntos
Blastômeros , Criopreservação , Crioprotetores , Vitrificação , Humanos , Crioprotetores/farmacologia , Feminino , Embrião de Mamíferos/efeitos dos fármacosRESUMO
The fracture behaviour of concrete is studied in various micro- and macro-damage models. This is important for estimating serviceability and stability of concrete structures. However, a detailed understanding of the material behaviour under load is often not available. In order to better interpret the fracture behaviour and pattern, images of lightweight concrete were taken using a high-resolution computed tomography (µ-CT) scanner. The samples were loaded between the taken images and the load was kept constant during the measurement. This study describes the method used and how the data set was analysed to investigate displacements and cracks. It has been shown that displacements and damage to the concrete structure can be detected prior to failure, allowing conclusions to be drawn about the structural behaviour. In principle, the µ-CT measurement can be used to examine different kinds of concrete as well as other systems with inorganic binders and to compare the fracture behaviour of different systems.
RESUMO
Faormamadinium based perovskites have been proposed to replace the methylammonium lead tri-iodide (MAPbI3) perovskite as the light absorbing layer of photovoltaic cells owing to their photo-active and chemically stable properties. However, the crystal phase transition from the photo-activeα-FAPbI3to the non-perovksiteδ-FAPbI3still occurs in un-doped FAPbI3films owing to the existence of crack defects, which degrads the photovoltaic responses. To investigate the crack ratio (CR)-dependent structure and excitonic characteristics of the polycrystalline FAPbI3thin films deposited on the carboxylic acid functionalized ITO/glass substrates, various spectra and images were measured and analyzed, which can be utilized to make sense of the different devices responses of the resultant perovskite based photovoltaic cells. Our experimental results show that the there is a trade-off between the formations of surface defects and trapped iodide-mediated defects, thereby resulting in an optimal crack density or CR of the un-dopedα-FAPbI3active layer in the range from 4.86% to 9.27%. The decrease in the CR (tensile stress) results in the compressive lattice and thereby trapping the iodides near the PbI6octahedra in the bottom region of the FAPbI3perovskite films. When the CR of the FAPbI3film is 8.47%, the open-circuit voltage (short-circuit current density) of the resultant photovoltaic cells significantly increased from 0.773 V (16.62 mA cm-2) to 0.945 V (18.20 mA cm-2) after 3 d. Our findings help understanding the photovoltaic responses of the FAPbI3perovskite based photovoltaic cells on the different days.
RESUMO
Crack cocaine is a highly addictive and potent stimulant drug. Animal studies have shown that the cholinergic system plays a role in neurotoxicity induced by cocaine or its active metabolites inhalation. Behavioral alterations associated with crack cocaine use include hyperactivity, depressed mood, and decreased seizure threshold. Here we evaluate the acetylcholinesterase (AChE) and reactive oxygen species (ROS) activity, behavioral profile, and the threshold for epileptic seizures in rats that received intrahippocampal pilocarpine (H-PILO) followed by exposure to crack cocaine (H-PILO + CRACK). Animals exposed to H-PILO + CRACK demonstrated increased severity and frequency of limbic seizures. The AChE activity was reduced in the groups exposed to crack cocaine alone (CRACK) and H-PILO + CRACK, whereas levels of ROS remained unchanged. In addition, crack cocaine exposure increased vertical locomotor activity, without changing water and sucrose intake. Short-term memory consolidation remained unchanged after H-PILO, H-PILO + CRACK, and CRACK administration. Overall, our data suggest that crack cocaine inhalation reduced the threshold for epileptic seizures in rats submitted to low doses of pilocarpine through the inhibition of AChE. Taken together, our findings can be useful in the development of effective strategies for preventing and treating the harmful effects of cocaine and crack cocaine on the central nervous system.
Assuntos
Acetilcolinesterase , Cocaína Crack , Pilocarpina , Ratos Wistar , Convulsões , Animais , Masculino , Acetilcolinesterase/metabolismo , Ratos , Pilocarpina/toxicidade , Convulsões/induzido quimicamente , Administração por Inalação , Modelos Animais de Doenças , Espécies Reativas de Oxigênio/metabolismo , Atividade Motora/efeitos dos fármacos , Hipocampo/efeitos dos fármacos , Hipocampo/metabolismoRESUMO
The paper investigates a problem concerning the equilibrium of a solid body containing a thin rigid inclusion and a crack. It is assumed that the body is hyperelastic, therefore, it is described within the framework of finite strain theory. One of the peculiarities of this problem is a global injectivity constraint, which prevents the body, the crack faces and the inclusion from both mutual and self penetration. First, the paper deals with the differential formulation of the problem. Next, we consider energy minimization, showing that the latter provides the weak formulation of the former. Finally, the existence of the weak solution is demonstrated through the use of the variational technique.This article is part of the theme issue 'Non-smooth variational problems with applications in mechanics'.
RESUMO
Several studies suggest that crack cocaine users exhibit higher prevalence of both psychiatric and psychosocial problems, with an aggressive pattern of drug use. Nevertheless, few experimental studies attempted to verify the neurotoxicity after crack cocaine exposure, especially when compared with other routes of cocaine administration. This systematic review aimed to verify whether in vitro and/or in vivo crack cocaine exposure is more neurotoxic than cocaine exposure (snorted or injected). A search was performed in the PubMed, EMBASE, Scopus, Web of Science, and LILACS databases for in vitro and in vivo toxicological studies conducted with either rats or mice, with no distinction with regard to sex or age. Other methods including BioRxiv, BDTD, Academic Google, citation searching, and specialist consultation were also adopted. Two independent investigators screened the titles and abstracts of retrieved studies and subsequently performed full-text reading and data extraction. The quality of the included studies was assessed by the Toxicological data Reliability assessment Tool (ToxRTool). The study protocol was registered with the Prospective Registry of Systematic Reviews (PROSPERO; CRD42022332250). Of the twelve studies included, three were in vitro and nine were in vivo studies. According to the ToxRTool, most studies were considered reliable either with or without restrictions, with no one being considered as not reliable. The studies found neuroteratogenic effects, decreased threshold for epileptic seizures, schizophrenic-like symptoms, and cognitive deficits to be associated with crack cocaine exposure. Moreover, both in vitro and in vivo studies reported a worsening in cocaine neurotoxic effect caused by the anhydroecgonine methyl ester (AEME), a cocaine main pyrolysis product, which is in line with the more aggressive pattern of crack cocaine use. This systematic review suggests that crack cocaine exposure is more neurotoxic than other routes of cocaine administration. However, before the scarcity of studies on this topic, further toxicological studies are necessary.
Assuntos
Cocaína Crack , Síndromes Neurotóxicas , Animais , Cocaína Crack/toxicidade , Síndromes Neurotóxicas/etiologia , Humanos , Camundongos , Ratos , Transtornos Relacionados ao Uso de CocaínaRESUMO
BACKGROUND: In recent years, overdoses involving illicit cocaine, methamphetamine, and other stimulants have increased in the U.S. The unintentional consumption of stimulants containing illicit fentanyl is a major risk factor for overdoses, particularly in Massachusetts and Rhode Island. Understanding the drug use patterns and strategies used by people who use stimulants (PWUS) to prevent overdose is necessary to identify risk and protective factors for stimulant and opioid-involved overdoses. Mixed-methods research with people who distribute drugs (PWDD) can also provide critical information into the mechanisms through which fentanyl may enter the stimulant supply, and the testing of drug samples can further triangulate PWUS and PWDD perspectives regarding the potency and adulteration of the drug supply. These epidemiological methods can inform collaborative intervention development efforts with community leaders to identify feasible, acceptable, and scalable strategies to prevent fatal and non-fatal overdoses in high-risk communities. METHODS: Our overall objective is to reduce stimulant and opioid-involved overdoses in regions disproportionately affected by the overdose epidemic. To meet this long-term objective, we employ a multi-pronged approach to identify risk and protective factors for unintentional stimulant and opioid-involved overdoses among PWUS and use these findings to develop a package of locally tailored intervention strategies that can be swiftly implemented to prevent overdoses. Specifically, this study aims to [1] Carry out mixed-methods research with incarcerated and non-incarcerated people who use or distribute illicit stimulants to identify risk and protective factors for stimulant and opioid-involved overdoses; [2] Conduct drug checking to examine the presence and relative quantity of fentanyl and other adulterants in the stimulant supply; and [3] Convene a series of working groups with community stakeholders involved in primary and secondary overdose prevention in Massachusetts and Rhode Island to contextualize our mixed-methods findings and identify multilevel intervention strategies to prevent stimulant-involved overdoses. DISCUSSION: Completion of this study will yield a rich understanding of the social epidemiology of stimulant and opioid-involved overdoses in addition to community-derived intervention strategies that can be readily implemented and scaled to prevent such overdoses in two states disproportionately impacted by the opioid and overdose crises: Massachusetts and Rhode Island.
Assuntos
Overdose de Drogas , Humanos , Overdose de Drogas/prevenção & controle , Overdose de Drogas/epidemiologia , Rhode Island/epidemiologia , Estimulantes do Sistema Nervoso Central/análise , Massachusetts/epidemiologia , Fatores de Risco , Fentanila/intoxicação , Fentanila/análiseRESUMO
Dentin is a biological composite exhibiting multilevel hierarchical structure, which confers excellent damage tolerance to this tissue. Despite the progress in characterization of fracture behavior of dentin, the contribution of composite structure consisting of peritubular dentin (PTD), intertubular dentin (ITD) and tubules to fracture resistance remains elusive. In this study, calculations are carried out for energy release rate associated with crack propagation in the microstructure of dentin. Crack penetration and deflection at the PTD-ITD interface are accounted for in the numerical analyses. It is found that high stiffness of the PTD plays a role in increasing crack driving force, promoting crack growth in the microstructure of dentin. For crack penetration across the PTD-ITD interface, the crack driving force increases with increasing tubule radius; and thick PTD generates amplified crack driving force, thereby leading to weak fracture resistance. The driving force for crack deflection increases with the increase in tubule radius in the case of short cracks, while for long cracks, there is a decrease in driving force with increasing tubule radius. Furthermore, we show that the competition between crack penetration and deflection at the PTD-ITD interface is controlled by the ratio of PTD to ITD elastic modulus, tubule radius and thickness of PTD. High PTD stiffness can increase the propensity of crack deflection. The microstructure of dentin with large tubule radius favors crack deflection and thick PTD is beneficial for crack penetration.