1.
Epilepsia ; 65(3): 651-663, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38258618

RESUMO

OBJECTIVE: We aimed to assess the ability of semiautomated electric source imaging (ESI) from long-term video-electroencephalographic (EEG) monitoring (LTM) to determine the epileptogenicity of temporopolar encephaloceles (TEs) in patients with temporal lobe epilepsy. METHODS: We conducted a retrospective study involving 32 temporal lobe epilepsy patients with TEs as potentially epileptogenic lesions in structural magnetic resonance imaging scans. Findings were validated through invasive intracerebral stereo-EEG in six of 32 patients and postsurgical outcome after tailored resection of the TE in 17 of 32 patients. LTM (mean duration = 6 days) was performed using the 10/20 system with additional T1/T2 for all patients and sphenoidal electrodes in 23 of 32 patients. Semiautomated detection and clustering of interictal epileptiform discharges (IEDs) were carried out to create IED types. ESI was performed on the averages of the two most frequent IED types per patient, utilizing individual head models, and two independent inverse methods (sLORETA [standardized low-resolution brain electromagnetic tomography], MUSIC [multiple signal classification]). ESI maxima concordance and propagation in spatial relation to TEs were quantified for sources with good signal quality (signal-to-noise ratio > 2, explained signal > 60%). RESULTS: ESI maxima correctly colocalized with a TE in 20 of 32 patients (62.5%) either at the onset or half-rising flank of at least one IED type per patient. ESI maxima showed propagation from the temporal pole to other temporal or extratemporal regions in 14 of 32 patients (44%), confirming propagation originating in the area of the TE. The findings from both inverse methods validated each other in 14 of 20 patients (70%), and sphenoidal electrodes exhibited the highest signal amplitudes in 17 of 23 patients (74%). The concordance of ESI with the TE predicted a seizure-free postsurgical outcome (Engel I vs. >I) with a diagnostic odds ratio of 2.1. SIGNIFICANCE: Semiautomated ESI from LTM often successfully identifies the epileptogenicity of TEs and the IED onset zone within the area of the TEs. Additionally, it shows potential predictive power for postsurgical outcomes in these patients.


Assuntos
Epilepsia do Lobo Temporal , Humanos , Epilepsia do Lobo Temporal/complicações , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/cirurgia , Eletroencefalografia/métodos , Encefalocele/complicações , Encefalocele/diagnóstico por imagem , Estudos Retrospectivos , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/cirurgia , Imageamento por Ressonância Magnética
2.
Brain ; 146(9): 3898-3912, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37018068

RESUMO

Neurosurgical intervention is the best available treatment for selected patients with drug resistant epilepsy. For these patients, surgical planning requires biomarkers that delineate the epileptogenic zone, the brain area that is indispensable for the generation of seizures. Interictal spikes recorded with electrophysiological techniques are considered key biomarkers of epilepsy. Yet, they lack specificity, mostly because they propagate across brain areas forming networks. Understanding the relationship between interictal spike propagation and functional connections among the involved brain areas may help develop novel biomarkers that can delineate the epileptogenic zone with high precision. Here, we reveal the relationship between spike propagation and effective connectivity among onset and areas of spread and assess the prognostic value of resecting these areas. We analysed intracranial EEG data from 43 children with drug resistant epilepsy who underwent invasive monitoring for neurosurgical planning. Using electric source imaging, we mapped spike propagation in the source domain and identified three zones: onset, early-spread and late-spread. For each zone, we calculated the overlap and distance from surgical resection. We then estimated a virtual sensor for each zone and the direction of information flow among them via Granger causality. Finally, we compared the prognostic value of resecting these zones, the clinically-defined seizure onset zone and the spike onset on intracranial EEG channels by estimating their overlap with resection. We observed a spike propagation in source space for 37 patients with a median duration of 95 ms (interquartile range: 34-206), a spatial displacement of 14 cm (7.5-22 cm) and a velocity of 0.5 m/s (0.3-0.8 m/s). In patients with good surgical outcome (25 patients, Engel I), the onset had higher overlap with resection [96% (40-100%)] than early-spread [86% (34-100%), P = 0.01] and late-spread [59% (12-100%), P = 0.002], and it was also closer to resection than late-spread [5 mm versus 9 mm, P = 0.007]. We found an information flow from onset to early-spread in 66% of patients with good outcomes, and from early-spread to onset in 50% of patients with poor outcome. Finally, resection of spike onset, but not area of spike spread or the seizure onset zone, predicted outcome with positive predictive value of 79% and negative predictive value of 56% (P = 0.04). Spatiotemporal mapping of spike propagation reveals information flow from onset to areas of spread in epilepsy brain. Surgical resection of the spike onset disrupts the epileptogenic network and may render patients with drug resistant epilepsy seizure-free without having to wait for a seizure to occur during intracranial monitoring.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Criança , Humanos , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia/métodos , Epilepsia/cirurgia , Convulsões , Resultado do Tratamento
3.
Epilepsia ; 64(4): 951-961, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36346269

RESUMO

OBJECTIVE: Electric source imaging (ESI) of interictal epileptiform discharges (IEDs) has shown significant yield in numerous studies; however, its implementation at most centers is labor- and cost-intensive. Semiautomatic ESI analysis (SAEA) has been proposed as an alternative and has previously shown benefit. Computer-assisted automatic spike cluster retrieval, averaging, and source localization are carried out for each cluster and are then reviewed by an expert neurophysiologist, to determine their relevance for the individual case. Here, we examine its yield in a prospective single center study. METHOD: Between 2017 and 2022, 122 patients underwent SAEA. Inclusion criteria for the current study were unifocal epilepsy disorder, epilepsy surgery with curative purpose, and postoperative follow-up of 2 years or more. All patients (N=40) had continuous video-electroencephalographic (EEG) monitoring with 37 scalp electrodes, which underwent SAEA. Forty patients matched our inclusion criteria. RESULTS: Twenty patients required intracranial monitoring; 13 were magnetic resonance imaging (MRI)-negative. Mean duration of analyzed EEG was 4.3 days (±3.1 days), containing a mean of 12 749 detected IEDs (±22 324). The sensitivity, specificity, and accuracy of SAEA for localizing the epileptogenic focus of the entire group were 74.3%, 80%, and 75%, respectively, leading to an odds ratio (OR) of 11.5 to become seizure-free if the source was included in the resection volume (p < .05). In patients with extratemporal lobe epilepsy, our results indicated an accuracy of 68% (OR=11.7). For MRI-negative patients (n = 13) and patients requiring intracranial EEG (n = 20), we found a similarly high accuracy of 84.6% (OR=19) and 75% (OR = 15.9), respectively. SIGNIFICANCE: In this prospective study of SAEA of long-term video-EEG, spanning several days, we found excellent localizing information and a high yield, even in difficult patient groups. This compares favorably to high-density ESI, most likely due to marked improved signal-to-noise ratio of the averaged IEDs. We propose including ESI, or SAEA, in the workup of all patients who are referred for epilepsy surgery.


Assuntos
Epilepsias Parciais , Epilepsia , Humanos , Estudos Prospectivos , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Epilepsias Parciais/cirurgia , Convulsões/diagnóstico por imagem , Convulsões/cirurgia , Imageamento por Ressonância Magnética/métodos
4.
Epilepsia ; 63(7): 1619-1629, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35357698

RESUMO

OBJECTIVES: High counts of averaged interictal epileptiform discharges (IEDs) are key components of accurate interictal electric source imaging (ESI) in patients with focal epilepsy. Automated detections may be time-efficient, but they need to identify the correct IED types. Thus we compared semiautomated and automated detection of IED types in long-term video-EEG (electroencephalography) monitoring (LTM) using an extended scalp EEG array and short-term high-density EEG (hdEEG) with visual detection of IED types and the seizure-onset zone (SOZ). METHODS: We prospectively recruited consecutive patients from four epilepsy centers who underwent both LTM with 40-electrode scalp EEG and short-term hdEEG with 256 electrodes. Only patients with a single circumscribed SOZ in LTM were included. In LTM and hdEEG, IED types were identified visually, semiautomatically and automatically. Concordances of semiautomated and automated detections in LTM and hdEEG, as well as visual detections in hdEEG, were compared against visually detected IED types and the SOZ in LTM. RESULTS: Fifty-two of 62 patients with LTM and hdEEG were included. The most frequent IED types per patient, detected semiautomatically and automatically in LTM and visually in hdEEG, were significantly concordant with the most frequently visually identified IED type in LTM and the SOZ. Semiautomated and automated detections of IED types in hdEEG were significantly concordant with visually identified IED types in LTM, only when IED types with more than 50 detected single IEDs were selected. The threshold of 50 detected IED in hdEEG was reached in half of the patients. For all IED types per patient, agreement between visual and semiautomated detections in LTM was high. SIGNIFICANCE: Semiautomated and automated detections of IED types in LTM show significant agreement with visually detected IED types and the SOZ. In short-term hdEEG, semiautomated detections of IED types are concordant with visually detected IED types and the SOZ in LTM if high IED counts were detected.


Assuntos
Epilepsias Parciais , Couro Cabeludo , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Convulsões
5.
Eur J Neurol ; 25(9): 1154-1160, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29751364

RESUMO

BACKGROUND AND PURPOSE: Accurate localization of the epileptic focus is essential for surgical treatment of patients with drug-resistant epilepsy. Electric source imaging (ESI) is increasingly used in pre-surgical evaluation. However, most previous studies have analysed interictal (II) discharges. Prospective studies comparing the feasibility and accuracy of II and ictal (IC) ESI are lacking. METHODS: We prospectively analysed long-term video-electroencephalography recordings (LTM) of patients admitted for pre-surgical evaluation. We performed ESI of II and IC signals using two methods, i.e. equivalent current dipole (ECD) and a distributed source model (DSM). LTM recordings employed the standard 25-electrode array (including inferior temporal electrodes). An age-matched template head model was used for source analysis. Results were compared with intracranial recordings, conventional neuroimaging methods [magnetic resonance imaging (MRI), positron emission tomography (PET), single-photon emission computed tomography (SPECT)] and outcome at 1 year after surgery. RESULTS: A total of 87 consecutive patients were analysed. ECD gave a significantly higher proportion of patients with localized focal abnormalities (94%) compared with MRI (70%), PET (66%) and SPECT (64%). Agreement between the ESI methods and intracranial recording was moderate to substantial (k = 0.56-0.79). A total of 54 patients were operated (47 patients more than 1 year ago) and 62% of them became seizure-free. The localization accuracy of II-ESI was 51% for DSM and 57% for ECD, and that for IC-ESI was 51% for DSM and 62% for ECD. The differences between the ESI methods were not significant. Differences in localization accuracy between ESI and MRI (55%), PET (33%) and SPECT (40%) were not significant. CONCLUSIONS: The II-ESI and IC-ESI of LTM data have high feasibility and their localization accuracy is similar to that of conventional neuroimaging methods.


Assuntos
Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Convulsões/fisiopatologia , Adolescente , Adulto , Mapeamento Encefálico , Criança , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroimagem , Tomografia por Emissão de Pósitrons , Período Pré-Operatório , Estudos Prospectivos , Convulsões/diagnóstico por imagem , Convulsões/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Adulto Jovem
6.
Hum Brain Mapp ; 37(7): 2528-46, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27059157

RESUMO

INTRODUCTION: Surgical treatment of drug-resistant epilepsy relies on the identification of the seizure onset zone (SOZ) and often requires intracranial EEG (iEEG). We have developed a new approach for non-invasive magnetic and electric source imaging of the SOZ (MSI-SOZ and ESI-SOZ) from ictal magnetoencephalography (MEG) and EEG recordings, using wavelet-based Maximum Entropy on the Mean (wMEM) method. We compared the performance of MSI-SOZ and ESI-SOZ with interictal spike source localization (MSI-spikes and ESI-spikes) and clinical localization of the SOZ (i.e., based on iEEG or lesion topography, denoted as clinical-SOZ). METHODS: A total of 46 MEG or EEG seizures from 13 patients were analyzed. wMEM was applied around seizure onset, centered on the frequency band showing the strongest power change. Principal component analysis applied to spatiotemporal reconstructed wMEM sources (0.4-1 s around seizure onset) identified the main spatial pattern of ictal oscillations. Qualitative sublobar concordance and quantitative measures of distance and spatial overlaps were estimated to compare MSI/ESI-SOZ with MSI/ESI-Spikes and clinical-SOZ. RESULTS: MSI/ESI-SOZ were concordant with clinical-SOZ in 81% of seizures (MSI 90%, ESI 64%). MSI-SOZ was more accurate and identified sources closer to the clinical-SOZ (P = 0.012) and to MSI-Spikes (P = 0.040) as compared with ESI-SOZ. MSI/ESI-SOZ and MSI/ESI-Spikes did not differ in terms of concordance and distance from the clinical-SOZ. CONCLUSIONS: wMEM allows non-invasive localization of the SOZ from ictal MEG and EEG. MSI-SOZ performs better than ESI-SOZ. MSI/ESI-SOZ can provide important additional information to MSI/ESI-Spikes during presurgical evaluation. Hum Brain Mapp 37:2528-2546, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Encéfalo/fisiopatologia , Eletrocorticografia , Magnetoencefalografia , Convulsões/diagnóstico , Convulsões/fisiopatologia , Adolescente , Adulto , Encéfalo/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/fisiopatologia , Eletrocorticografia/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Magnetoencefalografia/métodos , Masculino , Modelos Anatômicos , Imagem Multimodal , Cuidados Pré-Operatórios , Análise de Componente Principal , Convulsões/diagnóstico por imagem , Análise de Ondaletas , Adulto Jovem
7.
Epilepsia ; 57(1): 24-31, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26696504

RESUMO

OBJECTIVE: The aim of this study was to investigate the utility of three-dimensional electroencephalography source imaging (3D-ESI) with low-resolution electroencephalographic data in the pediatric noninvasive presurgical evaluation, and to compare the findings with positron emission tomography (PET) and ictal single-photon emission computed tomography (iSPECT). METHODS: We retrospectively selected 60 patients from a database of 594 patients who underwent excisional surgery for drug-resistant epilepsy. Patients were <18 years at time of surgery, had at least one presurgical volumetric brain magnetic resonance imaging (MRI), and at least 1 year of outcome data. 3D-ESI was performed with NeuroScan software CURRY V.7.0. For each patient the surgical resection was planned utilizing 3D-ESI as an adjunctive tool to supplement MRI and electrocorticographic data. Our analyses addressed three critical variables: pathology (focal cortical dysplasia vs. other pathologies), imaging (MRI negative vs. positive cases), and surgery (temporal resection vs. extratemporal and multilobar resections). We also compared the localizing utility and surgical outcome of 3D-ESI findings with PET, iSPECT, and the colocalized surgical resection. Statistical analyses were performed using the Statistical Package for the Social Sciences, Version 20. RESULTS: Mean age at surgery was 11.18 years (range 1-18 years). 3D-ESI showed a strong correlation with the surgical resection cavity (65.0%), particularly within the temporal lobe. 3D-ESI demonstrated better localization in MRI-negative cases (78.6%), which was not statistically significant. 3D-ESI also correlated with a superior surgical outcome profile compared to PET and iSPECT. SIGNIFICANCE: Our findings demonstrate that 3D-ESI data obtained with low-resolution electroencephalography achieves reasonably accurate noninvasive localization of epileptic spikes in pediatric focal epilepsy, especially in temporal lobe and MRI-negative cases, and is comparable to iSPECT and PET. Given its lesser expense and lack of radiation exposure, 3D-ESI is a useful and efficient tool for evaluating surgical candidacy in pediatric epilepsy surgery centers, particularly if PET and iSPECT are unavailable.


Assuntos
Encéfalo/patologia , Encéfalo/cirurgia , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia , Imageamento Tridimensional/métodos , Adolescente , Análise de Variância , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
8.
Brain Topogr ; 29(1): 162-81, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25609211

RESUMO

Distributed inverse solutions aim to realistically reconstruct the origin of interictal epileptic discharges (IEDs) from noninvasively recorded electroencephalography (EEG) and magnetoencephalography (MEG) signals. Our aim was to compare the performance of different distributed inverse solutions in localizing IEDs: coherent maximum entropy on the mean (cMEM), hierarchical Bayesian implementations of independent identically distributed sources (IID, minimum norm prior) and spatially coherent sources (COH, spatial smoothness prior). Source maxima (i.e., the vertex with the maximum source amplitude) of IEDs in 14 EEG and 19 MEG studies from 15 patients with focal epilepsy were analyzed. We visually compared their concordance with intracranial EEG (iEEG) based on 17 cortical regions of interest and their spatial dispersion around source maxima. Magnetic source imaging (MSI) maxima from cMEM were most often confirmed by iEEG (cMEM: 14/19, COH: 9/19, IID: 8/19 studies). COH electric source imaging (ESI) maxima co-localized best with iEEG (cMEM: 8/14, COH: 11/14, IID: 10/14 studies). In addition, cMEM was less spatially spread than COH and IID for ESI and MSI (p < 0.001 Bonferroni-corrected post hoc t test). Highest positive predictive values for cortical regions with IEDs in iEEG could be obtained with cMEM for MSI and with COH for ESI. Additional realistic EEG/MEG simulations confirmed our findings. Accurate spatially extended sources, as found in cMEM (ESI and MSI) and COH (ESI) are desirable for source imaging of IEDs because this might influence surgical decision. Our simulations suggest that COH and IID overestimate the spatial extent of the generators compared to cMEM.


Assuntos
Mapeamento Encefálico , Encéfalo/fisiopatologia , Epilepsias Parciais/patologia , Epilepsias Parciais/fisiopatologia , Teorema de Bayes , Encéfalo/patologia , Eletroencefalografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Magnetoencefalografia , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
9.
Hum Brain Mapp ; 35(9): 4396-414, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24615912

RESUMO

INTRODUCTION: Blood oxygenation level-dependent (BOLD) signal changes at the time of interictal epileptic discharges (IEDs) identify their associated vascular/hemodynamic responses. BOLD activations and deactivations can be found within the epileptogenic zone but also at a distance. Source imaging identifies electric (ESI) and magnetic (MSI) sources of IEDs, with the advantage of a higher temporal resolution. Therefore, the objective of our study was to evaluate the spatial concordance between ESI/MSI and BOLD responses for similar IEDs. METHODS: Twenty-one patients with similar IEDs in simultaneous electroencephalogram/functional magnetic resonance imaging (EEG/fMRI) and in simultaneous EEG/magnetoencephalogram (MEG) recordings were studied. IEDs in EEG/fMRI acquisition were analyzed in an event-related paradigm within a general linear model (GLM). ESI/MSI of averaged IEDs was performed using the Maximum Entropy on the Mean. We assessed the spatial concordance between ESI/MSI and clusters of BOLD activations/deactivations with surface-based metrics. RESULTS: ESI/MSI were concordant with one BOLD cluster for 20/21 patients (concordance with activation: 14/21 patients, deactivation: 6/21 patients, no concordance: 1/21 patients; concordance with MSI only: 3/21, ESI only: 2/21). These BOLD clusters exhibited in 19/20 cases the most significant voxel. BOLD clusters that were spatially concordant with ESI/MSI were concordant with IEDs from invasive recordings in 8/11 patients (activations: 5/8, deactivations: 3/8). CONCLUSION: As the results of BOLD, ESI and MSI are often concordant, they reinforce our confidence in all of them. ESI and MSI confirm the most significant BOLD cluster within BOLD maps, emphasizing the importance of these clusters for the definition of the epileptic focus.


Assuntos
Encéfalo/fisiopatologia , Circulação Cerebrovascular/fisiologia , Eletroencefalografia/métodos , Epilepsias Parciais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/métodos , Adulto , Encéfalo/irrigação sanguínea , Mapeamento Encefálico/métodos , Epilepsias Parciais/tratamento farmacológico , Hemodinâmica , Humanos , Modelos Lineares , Oxigênio/sangue , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Adulto Jovem
10.
Epilepsia Open ; 8(3): 877-887, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37170682

RESUMO

OBJECTIVE: To investigate cost in working hours for initial integration of interictal EEG source localization (ESL) into clinical practice of a tertiary epilepsy center, and to examine concordance of results obtained with three different ESL pipelines. METHODS: This prospective study covered the first year of using ESL in the Epilepsy-Center Berlin-Brandenburg. Patients aged ≥14 years with drug-resistant focal epilepsy referred for noninvasive presurgical evaluation were included. Interictal ESL was based on low-density EEG and individual head models. Source maxima were obtained from two freely available software packages and one commercial provider. One physician and computer scientist documented their working hours for setting up and processing ESL. Additionally, a survey was conducted among epilepsy centers in Germany to assess the current role of ESL in presurgical evaluation. RESULTS: Of 40 patients included, 22 (55%) had enough interictal spikes for ESL. The physician's working times decreased from median 4.7 hours [interquartile range 3.9-6.4] in the first third of cases to 2.0 hours [1.9-2.4] in the remaining two thirds; P < 0.01. In addition, computer scientist and physician spent a total of 35.5 and 33.0 working hours on setting up the digital infrastructure, and on training and testing. Sublobar agreement between all three pipelines was 20%, mean measurement of agreement (kappa) 0.13. Finally, the survey revealed that 53% of epilepsy centers in Germany currently use ESL for presurgical evaluation. SIGNIFICANCE: This study provides information regarding expected effort and costs for integration of ESL into an epilepsy surgery program. Low result agreement across different ESL pipelines calls for further standardization.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Humanos , Eletroencefalografia/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Epilepsia/diagnóstico , Epilepsia/cirurgia , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/cirurgia
11.
Epilepsia Open ; 8(3): 785-796, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36938790

RESUMO

OBJECTIVE: Presurgical high-density electric source imaging (hdESI) of interictal epileptic discharges (IEDs) is only used by few epilepsy centers. One obstacle is the time-consuming workflow both for recording as well as for visual review. Therefore, we analyzed the effect of (a) an automated IED detection and (b) the number of IEDs on the accuracy of hdESI and time-effectiveness. METHODS: In 22 patients with pharmacoresistant focal epilepsy receiving epilepsy surgery (Engel 1) we retrospectively detected IEDs both visually and semi-automatically using the EEG analysis software Persyst in 256-channel EEGs. The amount of IEDs, the Euclidean distance between hdESI maximum and resection zone, and the operator time were compared. Additionally, we evaluated the intra-individual effect of IED quantity on the distance between hdESI maximum of all IEDs and hdESI maximum when only a reduced amount of IEDs were included. RESULTS: There was no significant difference in the number of IEDs between visually versus semi-automatically marked IEDs (74 ± 56 IEDs/patient vs 116 ± 115 IEDs/patient). The detection method of the IEDs had no significant effect on the mean distances between resection zone and hdESI maximum (visual: 26.07 ± 31.12 mm vs semi-automated: 33.6 ± 34.75 mm). However, the mean time needed to review the full datasets semi-automatically was shorter by 275 ± 46 min (305 ± 72 min vs 30 ± 26 min, P < 0.001). The distance between hdESI of the full versus reduced amount of IEDs of the same patient was smaller than 1 cm when at least a mean of 33 IEDs were analyzed. There was a significantly shorter intraindividual distance between resection zone and hdESI maximum when 30 IEDs were analyzed as compared to the analysis of only 10 IEDs (P < 0.001). SIGNIFICANCE: Semi-automatized processing and limiting the amount of IEDs analyzed (~30-40 IEDs per cluster) appear to be time-saving clinical tools to increase the practicability of hdESI in the presurgical work-up.


Assuntos
Epilepsia , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Fluxo de Trabalho , Imageamento por Ressonância Magnética/métodos , Epilepsia/diagnóstico
12.
Front Neurosci ; 17: 1170862, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255753

RESUMO

Magneto- and electroencephalography (M/EEG) are widespread techniques to measure neural activity in-vivo at a high temporal resolution but low spatial resolution. Locating the neural sources underlying the M/EEG poses an inverse problem, which is ill-posed. We developed a new method based on Recursive Application of Multiple Signal Classification (MUSIC). Our proposed method is able to recover not only the locations but, in contrast to other inverse solutions, also the extent of active brain regions flexibly (FLEX-MUSIC). This is achieved by allowing it to search not only for single dipoles but also dipole clusters of increasing extent to find the best fit during each recursion. FLEX-MUSIC achieved the highest accuracy for both single dipole and extended sources compared to all other methods tested. Remarkably, FLEX-MUSIC was capable to accurately estimate the level of sparsity in the source space (r = 0.82), whereas all other approaches tested failed to do so (r ≤ 0.18). The average computation time of FLEX-MUSIC was considerably lower compared to a popular Bayesian approach and comparable to that of another recursive MUSIC approach and eLORETA. FLEX-MUSIC produces only few errors and was capable to reliably estimate the extent of sources. The accuracy and low computation time of FLEX-MUSIC renders it an improved technique to solve M/EEG inverse problems both in neuroscience research and potentially in pre-surgery diagnostic in epilepsy.

13.
Clin Neurophysiol Pract ; 7: 245-251, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36062078

RESUMO

Objective: The goal of this study was to investigate the diagnostic utility of electric source imaging (ESI) in the presurgical evaluation of children with focal cortical dysplasia (FCD) and to compare it with other imaging techniques. Methods: Twenty patients with epilepsy onset before 18 years, surgically treated focal epilepsy with a minimal follow-up of 2 years, and histologically proven FCD were retrospectively selected. All patients underwent MRI, positron emission tomography (PET), and 16 patients also had ictal single-photon emission computed tomography (iSPECT). ESI, using EEG with 64 electrodes or more (HD-ESI), was performed in all 20 patients. We determined sensitivity, specificity and accuracy of ESI, and compared its yield to that of other imaging techniques. Results: Twelve patients were seizure-free post-operatively (60%). Among all patients, highest localization accuracy (80%) was obtained with ESI, followed by PET and iSPECT (75%). When results from ESI and SPECT were concordant 100% of patients achieved Engel I outcome. If ESI and PET showed concordant localization, 90% of patients achieved postoperative seizure freedom. Conclusions: Our findings demonstrate that HD-ESI allows accurate localization of the epileptogenic zone in patients with FCD. Significance: In combination with other imaging modalities, ESI helps with planning a more accurate surgery and therefore, the chances of postoperative seizure control are higher. Since it is based on EEG recordings, it does not require sedation, which is particularly interesting in pediatric patients. ESI represents an important imaging tool in focal epilepsies due to cortical dysplasia, which might be difficult to detect on standard imaging.

14.
Clin Neurophysiol ; 141: 126-138, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-33875376

RESUMO

OBJECTIVE: To assess the utility of interictal magnetic and electric source imaging (MSI and ESI) using dipole clustering in magnetic resonance imaging (MRI)-negative patients with drug resistant epilepsy (DRE). METHODS: We localized spikes in low-density (LD-EEG) and high-density (HD-EEG) electroencephalography as well as magnetoencephalography (MEG) recordings using dipoles from 11 pediatric patients. We computed each dipole's level of clustering and used it to discriminate between clustered and scattered dipoles. For each dipole, we computed the distance from seizure onset zone (SOZ) and irritative zone (IZ) defined by intracranial EEG. Finally, we assessed whether dipoles proximity to resection was predictive of outcome. RESULTS: LD-EEG had lower clusterness compared to HD-EEG and MEG (p < 0.05). For all modalities, clustered dipoles showed higher proximity to SOZ and IZ than scattered (p < 0.001). Resection percentage was higher in optimal vs. suboptimal outcome patients (p < 0.001); their proximity to resection was correlated to outcome (p < 0.001). No difference in resection percentage was seen for scattered dipoles between groups. CONCLUSION: MSI and ESI dipole clustering helps to localize the SOZ and IZ and facilitate the prognostic assessment of MRI-negative patients with DRE. SIGNIFICANCE: Assessing the MSI and ESI clustering allows recognizing epileptogenic areas whose removal is associated with optimal outcome.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Criança , Análise por Conglomerados , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Eletrocorticografia/métodos , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/patologia , Epilepsia/cirurgia , Humanos , Imageamento por Ressonância Magnética , Magnetoencefalografia/métodos , Convulsões/cirurgia
15.
Seizure ; 90: 145-154, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33608134

RESUMO

While most patients with focal epilepsy present with clear structural abnormalities on standard, 1.5 or 3 T MRI, some patients are MRI-negative. For those, quantitative MRI techniques, such as volumetry, voxel-based morphometry, and relaxation time measurements can aid in finding the epileptogenic focus. High-field MRI, just recently approved for clinical use by the FDA, increases the resolution and, in several publications, was shown to improve the detection of focal cortical dysplasias and mild cortical malformations. For those cases without any tissue abnormality in neuroimaging, even at 7 T, scalp EEG alone is insufficient to delimitate the epileptogenic zone. They may benefit from the use of high-density EEG, in which the increased number of electrodes helps improve spatial sampling. The spatial resolution of even low-density EEG can benefit from electric source imaging techniques, which map the source of the recorded abnormal activity, such as interictal epileptiform discharges, focal slowing, and ictal rhythm. These EEG techniques help localize the irritative, functional deficit, and seizure-onset zone, to better estimate the epileptogenic zone. Combining those technologies allows several drug-resistant cases to be submitted to surgery, increasing the odds of seizure freedom and providing a must needed hope for patients with epilepsy.


Assuntos
Encéfalo , Epilepsias Parciais , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Eletroencefalografia , Humanos , Imageamento por Ressonância Magnética , Resultado do Tratamento
16.
Clin Neurophysiol Pract ; 6: 149-154, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35112033

RESUMO

We discuss the achievements of the ACNS critical care EEG nomenclature proposed in 2013 and, from a clinical angle, outline some limitations regarding translation into treatment implications. While the recently proposed updated 2021 version of the nomenclature will probable improve some uncertainty areas, a refined understanding of the mechanisms at the origin of the EEG patterns, and a multimodal integration of the nomenclature to the clinical context may help improving the rationale supporting therapeutic procedures. We illustrate these aspects on prognostication after cardiac arrest.

17.
Epilepsy Res ; 159: 106245, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31846783

RESUMO

BACKGROUND: Electric Source Imaging (ESI) of interictal epileptiform discharges (IED) is increasingly validated for localizing epileptic activity. In children, IED can be absent or multifocal even in cases of a focal epileptogenic zone and additional electrophysiological markers are needed. Here, we investigated ESI of pathological focal slowing (FS) recorded on EEG as a new localizing marker in children with drug-resistant epilepsy. METHODS: We selected 15 children (median: 12; range: 4-18yrs), with high-density EEG (hdEEG), presurgical evaluation and surgical resection. One patient had a non-lesional MRI. ESI of patient-specific focal slow activity was performed (distributed linear inverse solution and individual head model). The maximal average power in the band of interest was considered as the source of focal slowing (ESI-FS). The Euclidian distance between ESI-FS and the resection (5 mm margin) was compared to the localization of maximal ESI of interictal epileptiform discharges (ESI-IED), interictal FDG-PET and ictal SPECT/SISCOM. RESULTS: In 9/15 patients (60%), ESI of focal slowing (ESI-FS) was inside or ≤5 mm from resection margins. The remaining 6/15 cases had distances ≤15 mm. In 9/15 patients with interictal spikes, the ESI-IED was concordant with the resection. 6/15 patients with concordant ESI-FS showed also interictal concordant ESI of IED; in 3/15 patients, ESI-FS but not ESI-IED was concordant with the resection. In 10/15 patients, ESI-FS was concordant with MRI lesion and for ESI-IED this concordance was on 8/15 patients. Maximal hypometabolism and SISCOM were concordant with the resection for 7/15 and 7/12, respectively. CONCLUSION: These findings suggest that "non-epileptiform" EEG activity, such as focal slowing, could be a complementary useful marker to localize the epileptogenic zone. ESI-FS may notably be applied in young patients without focal interictal spikes or multifocal spikes. This potential new marker of brain dysfunction has potential applications to other neurological disorders associated with slow EEG activity.


Assuntos
Encéfalo/fisiopatologia , Epilepsia Resistente a Medicamentos/fisiopatologia , Epilepsias Parciais/fisiopatologia , Adolescente , Mapeamento Encefálico/métodos , Criança , Pré-Escolar , Eletroencefalografia , Feminino , Humanos , Masculino , Tomografia Computadorizada de Emissão de Fóton Único
18.
Clin Neurophysiol Pract ; 5: 16-22, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31909306

RESUMO

OBJECTIVE: In this study, we sought to determine whether visual analysis of high density EEG (HD-EEG) would provide similar localizing information comparable to electrical source imaging (ESI). METHODS: HD-EEG (256 electrodes) recordings from 20 patients suffering from unifocal, drug-resistant epilepsy (13 women, mean age 29.1 ±â€¯2.62 years, 11 with temporal lobe epilepsy) were examined. In the visual analysis condition, we identified the 5 contacts with maximal spike amplitude and determined their localization with respect to the underlying cortex. ESI was computed using the LAURA algorithm of the averaged spikes in the patient's individual MRI. We considered the localization "correct" if all 5 contacts were concordant with the resection volume underneath or if ESI was located within the resection as determined by the postoperative MRI. RESULTS: Twelve patients were postoperatively seizure-free (Engel Class IA), while the remaining eight were in class IB to IV. Visual analysis and ESI showed sensitivity of 58% and 75%, specificity of 75% and 87%, and accuracy of 65% and 80%, respectively. In 70% of cases, visual analysis and ESI provided concordant results. CONCLUSIONS: Localization of the electrodes with maximal spike amplitude provides very good estimation of the localization of the underlying source. However, ESI has a higher accuracy and adds 3D information; therefore, it should remain the tool of choice for presurgical evaluation. SIGNIFICANCE: The present study proposes the possibility to analyze HD-EEG visually, in tandem with ESI or alone, if ESI is not accessible.

19.
Expert Rev Med Devices ; 17(5): 405-412, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32223351

RESUMO

Introduction: Electric source imaging (ESI) refers to the estimation of the cerebral sources of electric signals recorded at the head surface using electroencephalography (EEG). Thanks to the availability of EEG systems with high numbers of electrodes and to progress in software to analyze the signals they collect, ESI can be applied to epilepsy-related pathological EEG signals like interictal spikes and seizures.Areas covered: In this narrative review, we discuss selected original research articles on the use of ESI in epilepsy patients considered for surgery. Epilepsy-related activity can be localized accurately using ESI, as established by comparison to the gold standards of intracranial EEG and seizure control following epilepsy surgery. The information brought by ESI complements successfully that of other techniques like magnetic resonance imaging and positron-emission tomography, and is clinically relevant to patient management.Expert opinion: EEG is a readily available technique to measure brain activity in real time. Given its accuracy and usefulness, ESI should become part of the routine practice of clinical neurophysiology laboratories and epilepsy centers in the presurgical management of epilepsy patients.


Assuntos
Fontes de Energia Elétrica , Epilepsia/cirurgia , Eletrodos , Eletroencefalografia , Epilepsia/diagnóstico por imagem , Humanos , Software , Resultado do Tratamento
20.
Clin Neurophysiol ; 131(3): 734-743, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32007920

RESUMO

OBJECTIVE: To localize the seizure onset zone (SOZ) and irritative zone (IZ) using electric source imaging (ESI) on intracranial EEG (iEEG) and assess their clinical value in predicting epilepsy surgery outcome in children with focal cortical dysplasia (FCD). METHODS: We analyzed iEEG data from 25 children with FCD-associated medically refractory epilepsy (MRE) who underwent surgery. We performed ESI on ictal onset to localize SOZ (ESI-SOZ) and on interictal discharges to localize IZ (ESI-IZ). We tested whether resection of ESI-SOZ and ESI-IZ predicted good surgical outcome (Engel 1). We further compared the prediction performance of ESI-SOZ and ESI-IZ to those of SOZ and IZ defined using conventional methods, i.e. by identifying iEEG-contacts showing ictal onsets (conventional-SOZ) or being the most interictally active (conventional-IZ). RESULTS: The proximity of ESI-SOZ (p = 0.043, odds-ratio = 3.9) and ESI-IZ (p = 0.011, odds-ratio = 7.04) to resection has higher effect on patients' outcome than proximity of conventional-SOZ (p = 0.17, odds-ratio = 1.7) and conventional-IZ (p = 0.038, odds-ratio = 2.6). Resection of ESI-SOZ and ESI-IZ presented higher discriminative power in predicting outcome (68% and 60%) than conventional-SOZ and conventional-IZ (48% and 53%). CONCLUSIONS: Localizing SOZ and IZ via ESI on iEEG offers higher predictive value compared to conventional-iEEG interpretation. SIGNIFICANCE: iEEG-ESI may help surgical planning and facilitate prognostic assessment of children with FCD-associated MRE.


Assuntos
Encéfalo/fisiopatologia , Epilepsia Resistente a Medicamentos/fisiopatologia , Epilepsia/fisiopatologia , Malformações do Desenvolvimento Cortical do Grupo I/fisiopatologia , Adolescente , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Mapeamento Encefálico , Criança , Pré-Escolar , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Malformações do Desenvolvimento Cortical do Grupo I/diagnóstico por imagem , Malformações do Desenvolvimento Cortical do Grupo I/cirurgia , Período Pré-Operatório , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento