Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Orthop J Sports Med ; 10(9): 23259671221119173, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36119121

RESUMO

Background: Investigations on the biomechanical characteristics of the anterior horn of the lateral meniscus (AHLM) related to anterior cruciate ligament (ACL) tibial tunnel reaming have revealed increased contact pressure between the femur and tibia, decreased attachment area, and decreased ultimate failure strength. Purpose/Hypothesis: The purpose of this study was to investigate the influence of a complete radial tear of the AHLM on force distribution in response to applied anterior and posterior drawer forces and internal and external rotation torques. We hypothesized that the AHLM plays an important role in knee stability, primarily at lower knee flexion angles. Study Design: Controlled laboratory study. Methods: A total of 9 fresh-frozen cadaveric knee specimens and a robotic testing system were used. Anterior and posterior drawer forces up to 89 N and internal and external rotation torques up to 4 N·m were applied at 0°, 30°, 60°, and 90° of knee flexion. A complete AHLM tear was then made 10 mm from the lateral border of the tibial attachment of the ACL, and the same tests performed in the intact state were repeated. Next, the recorded intact knee motion was reproduced in the AHLM-torn knee, and the change in the resultant force after an AHLM tear was determined by calculating the difference between the 2 states. Results: In the torn AHLM, the reduction in the resultant force at 0° for external rotation torque (34.8 N) was larger than that at 60° (5.2 N; P < .01) and 90° (6.7 N; P < .01). Conclusion: The AHLM played a role in facilitating knee stability against an applied posterior drawer force of 89 N and external rotation torque of 4 N·m, especially at lower knee flexion angles. Clinical Relevance: This study provides information about the effects of AHLM injuries that may occur during single-bundle ACL reconstruction using a round tunnel.

2.
Orthop J Sports Med ; 10(12): 23259671221139876, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36545379

RESUMO

Background: For skeletally immature patients, over-the-top (OTT) anterior cruciate ligament (ACL) reconstruction (ACLR) is preferred. However, increased anterior laxity at deep knee flexion angles remains concerning. We modified the procedure to proximally shift the graft fixation site on the femur to prevent graft loosening at higher knee flexion angles and named it the supra-OTT procedure. Purpose: To compare anterior laxity and in situ forces of the ACL graft between conventional OTT and supra-OTT ACLR in a cadaveric model. Study Design: Controlled laboratory study. Methods: A total of 11 fresh-frozen cadaveric knee specimens underwent 4 robotic testing conditions: ACL intact, ACL resected, conventional OTT, and supra-OTT. For each condition, a 100-N load was applied at 0°, 15°, 30°, 60°, and 90° of knee flexion to simulate the Lachman test or anterior drawer test. In addition, a combined load of 5-N·m internal tibial torque and 10-N·m valgus torque was applied at 15° and 30° of knee flexion as a simulated pivot-shift test. Anterior tibial translation and in situ graft forces were recorded. The only difference between conventional OTT and supra-OTT ACLR was the graft fixation site on the femur. For conventional OTT ACLR, graft fixation was performed just on the proximal and lateral ends of the posterior condyle. For supra-OTT ACLR, the fixation point was around the proximal insertion of the lateral head of the gastrocnemius and the lateral edge of the posterior cortex, approximately 2 cm proximal to the conventional OTT position. Results: On the simulated anterior drawer test at 60° and 90° of knee flexion, anterior tibial translation after supra-OTT ACLR was significantly smaller than after conventional OTT ACLR (P < .01). However, no significant differences were noted at other flexion angles or on the simulated pivot-shift test between the conventional OTT and supra-OTT procedures. Some overconstraint and higher graft forces were noted with both techniques, but the supra-OTT technique caused even more overconstraint at higher flexion angles. Conclusion: Supra-OTT ACLR showed better biomechanical performance to control anterior laxity than conventional OTT ACLR at higher knee flexion angles. Clinical Relevance: The supra-OTT procedure may improve anterior stability at deep knee flexion angles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA