Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cogn Affect Behav Neurosci ; 24(4): 631-659, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38834886

RESUMO

The P300 ERP component, related to the onset of task-relevant or infrequent stimuli, has been widely used in the Mobile Brain/Body Imaging (MoBI) literature. This systematic review evaluates the quality and breadth of P300 MoBI studies, revealing a maturing field with well-designed research yet grappling with standardization and global representation challenges. While affirming the reliability of measuring P300 ERP components in mobile settings, the review identifies significant hurdles in standardizing data cleaning and processing techniques, impacting comparability and reproducibility. Geographical disparities emerge, with studies predominantly in the Global North and a dearth of research from the Global South, emphasizing the need for broader inclusivity to counter the WEIRD bias in psychology. Collaborative projects and mobile EEG systems showcase the feasibility of reaching diverse populations, which is essential to advance precision psychiatry and to integrate varied data streams. Methodologically, a trend toward ecological validity is noted, shifting from lab-based to real-world settings with portable EEG system advancements. Future hardware developments are expected to balance signal quality and sensor intrusiveness, enriching data collection in everyday contexts. Innovative methodologies reflect a move toward more natural experimental settings, prompting critical questions about the applicability of traditional ERP markers, such as the P300 outside structured paradigms. The review concludes by highlighting the crucial role of integrating mobile technologies, physiological sensors, and machine learning to advance cognitive neuroscience. It advocates for an operational definition of ecological validity to bridge the gap between controlled experiments and the complexity of embodied cognitive experiences, enhancing both theoretical understanding and practical application in study design.


Assuntos
Cognição , Eletroencefalografia , Potenciais Evocados P300 , Humanos , Potenciais Evocados P300/fisiologia , Eletroencefalografia/métodos , Cognição/fisiologia , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem
2.
Psychophysiology ; 61(9): e14603, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38798056

RESUMO

Although historically confined to traditional research laboratories, electroencephalography (EEG) paradigms are now being applied to study a wide array of behaviors, from daily activities to specialized tasks in diverse fields such as sports science, neurorehabilitation, and education. This transition from traditional to real-world mobile research can provide new tools for understanding attentional processes as they occur naturally. Early mobile EEG research has made progress, despite the large size and wired connections. Recent developments in hardware and software have expanded the possibilities of mobile EEG, enabling a broader range of applications. Despite these advancements, limitations influencing mobile EEG remain that must be overcome to achieve adequate reliability and validity. In this review, we first assess the feasibility of mobile paradigms, including electrode selection, artifact correction techniques, and methodological considerations. This review underscores the importance of ecological, construct, and predictive validity in ensuring the trustworthiness and applicability of mobile EEG findings. Second, we explore studies on attention in naturalistic settings, focusing on replicating classic P3 component studies in mobile paradigms like stationary biking in our lab, and activities such as walking, cycling, and dual-tasking outside of the lab. We emphasize how the mobile approach complements traditional laboratory paradigms and the types of insights gained in naturalistic research settings. Third, we discuss promising applications of portable EEG in workplace safety and other areas including road safety, rehabilitation medicine, and brain-computer interfaces. In summary, this review explores the expanding possibilities of mobile EEG while recognizing the existing challenges in fully realizing its potential.


Assuntos
Atenção , Eletroencefalografia , Humanos , Eletroencefalografia/métodos , Atenção/fisiologia , Aplicativos Móveis , Potenciais Evocados P300/fisiologia
3.
Sensors (Basel) ; 23(17)2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37687895

RESUMO

Electroencephalography (EEG) is a crucial tool in cognitive neuroscience, enabling the study of neurophysiological function by measuring the brain's electrical activity. Its applications include perception, learning, memory, language, decision making and neural network mapping. Recently, interest has surged in extending EEG measurements to domestic environments. However, the high costs associated with traditional laboratory EEG systems have hindered accessibility for many individuals and researchers in education, research, and medicine. To tackle this, a mobile-EEG device named "DreamMachine" was developed. A more affordable alternative to both lab-based EEG systems and existing mobile-EEG devices. This system boasts 24 channels, 24-bit resolution, up to 6 h of battery life, portability, and a low price. Our open-source and open-hardware approach empowers cognitive neuroscience, especially in education, learning, and research, opening doors to more accessibility. This paper introduces the DreamMachine's design and compares it with the lab-based EEG system "asalabTM" in an eyes-open and eyes-closed experiment. The Alpha band exhibited higher power in the power spectrum during eyes-closed conditions, whereas the eyes-open condition showed increased power specifically within the Delta frequency range. Our analysis confirms that the DreamMachine accurately records brain activity, meeting the necessary standards when compared to the asalabTM system.


Assuntos
Computadores de Mão , Aprendizagem , Humanos , Fontes de Energia Elétrica , Eletroencefalografia , Olho
4.
Sensors (Basel) ; 23(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37447780

RESUMO

Objective: We designed and validated a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain-computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user's hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An inertial measurement unit (IMU) provides monitoring of head movements. The EEG amplifier operates with 24-bit resolution up to 500 Hz sampling frequency and can communicate with other devices using 802.11 b/g/n WiFi. It has high signal-to-noise ratio (SNR) and common-mode rejection ratio (CMRR) (121 dB and 110 dB, respectively) and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as a backend coding language and JavaScript (JS), Cascading Style Sheets (CSS), and HyperText Markup Language (HTML) as front-end coding languages and includes training and optimization of support vector machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human-subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation and provides proof-of-concept validation for the device's use at both the clinic and at home. Significance: The usability, interoperability, portability, reliability, and programmability of the proposed wireless closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.


Assuntos
Interfaces Cérebro-Computador , Humanos , Reprodutibilidade dos Testes , Eletroencefalografia , Encéfalo , Movimentos Oculares
5.
Hum Factors ; 65(1): 86-106, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-33861182

RESUMO

OBJECTIVE: We demonstrate and discuss the use of mobile electroencephalogram (EEG) for neuroergonomics. Both technical state of the art as well as measures and cognitive concepts are systematically addressed. BACKGROUND: Modern work is increasingly characterized by information processing. Therefore, the examination of mental states, mental load, or cognitive processing during work is becoming increasingly important for ergonomics. RESULTS: Mobile EEG allows to measure mental states and processes under real live conditions. It can be used for various research questions in cognitive neuroergonomics. Besides measures in the frequency domain that have a long tradition in the investigation of mental fatigue, task load, and task engagement, new approaches-like blink-evoked potentials-render event-related analyses of the EEG possible also during unrestricted behavior. CONCLUSION: Mobile EEG has become a valuable tool for evaluating mental states and mental processes on a highly objective level during work. The main advantage of this technique is that working environments don't have to be changed while systematically measuring brain functions at work. Moreover, the workflow is unaffected by such neuroergonomic approaches.


Assuntos
Cognição , Eletroencefalografia , Humanos , Cognição/fisiologia , Potenciais Evocados/fisiologia , Local de Trabalho , Ergonomia
6.
Neuroimage ; 251: 118994, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35181552

RESUMO

Building machine learning models using EEG recorded outside of the laboratory setting requires methods robust to noisy data and randomly missing channels. This need is particularly great when working with sparse EEG montages (1-6 channels), often encountered in consumer-grade or mobile EEG devices. Neither classical machine learning models nor deep neural networks trained end-to-end on EEG are typically designed or tested for robustness to corruption, and especially to randomly missing channels. While some studies have proposed strategies for using data with missing channels, these approaches are not practical when sparse montages are used and computing power is limited (e.g., wearables, cell phones). To tackle this problem, we propose dynamic spatial filtering (DSF), a multi-head attention module that can be plugged in before the first layer of a neural network to handle missing EEG channels by learning to focus on good channels and to ignore bad ones. We tested DSF on public EEG data encompassing ∼4000 recordings with simulated channel corruption and on a private dataset of ∼100 at-home recordings of mobile EEG with natural corruption. Our proposed approach achieves the same performance as baseline models when no noise is applied, but outperforms baselines by as much as 29.4% accuracy when significant channel corruption is present. Moreover, DSF outputs are interpretable, making it possible to monitor the effective channel importance in real-time. This approach has the potential to enable the analysis of EEG in challenging settings where channel corruption hampers the reading of brain signals.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Algoritmos , Encéfalo , Eletroencefalografia/métodos , Humanos , Aprendizado de Máquina , Redes Neurais de Computação
7.
Neuroimage ; 264: 119757, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36414209

RESUMO

Walking influences visual processing but the underlying mechanism remains poorly understood. In this study, we investigated the influence of walking on pre-stimulus and stimulus-induced visual neural activity and behavioural performance in a discrimination task while participants were standing or freely walking. The results showed dissociable pre- and post-stimulus influences by the movement state. Walking was associated with a reduced pre-stimulus alpha power, which predicted enhanced N1 and decreased P3 components during walking. This pre-stimulus alpha activity was additionally modulated by time on the task, which was paralleled by a similar behavioural modulation. In contrast, the post-stimulus alpha power was reduced in its modulation due to stimulus onset during walking but showed no evidence of modulation by time on the task. Additionally, stimulus parameters (eccentricity, laterality, distractor presence significantly influenced post-stimulus alpha power, whereas the visually evoked components showed no evidence of such an influence. There was further no evidence of a correlation between pre-stimulus and post stimulus alpha power. We conclude that walking has two dissociable influences on visual processing: while the walking induced reduction in alpha power suggests an attentional state change that relates to visual awareness, the post-stimulus influence on alpha power modulation indicates changed spatial visual processing during walking.


Assuntos
Eletroencefalografia , Percepção Visual , Humanos , Percepção Visual/fisiologia , Atenção/fisiologia , Lateralidade Funcional , Caminhada , Estimulação Luminosa
8.
Hum Brain Mapp ; 43(4): 1295-1308, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34796574

RESUMO

High-density electroencephalography (HD-EEG) is currently limited to laboratory environments since state-of-the-art electrode caps require skilled staff and extensive preparation. We propose and evaluate a 256-channel cap with dry multipin electrodes for HD-EEG. We describe the designs of the dry electrodes made from polyurethane and coated with Ag/AgCl. We compare in a study with 30 volunteers the novel dry HD-EEG cap to a conventional gel-based cap for electrode-skin impedances, resting state EEG, and visual evoked potentials (VEP). We perform wearing tests with eight electrodes mimicking cap applications on real human and artificial skin. Average impedances below 900 kΩ for 252 out of 256 dry electrodes enables recording with state-of-the-art EEG amplifiers. For the dry EEG cap, we obtained a channel reliability of 84% and a reduction of the preparation time of 69%. After exclusion of an average of 16% (dry) and 3% (gel-based) bad channels, resting state EEG, alpha activity, and pattern reversal VEP can be recorded with less than 5% significant differences in all compared signal characteristics metrics. Volunteers reported wearing comfort of 3.6 ± 1.5 and 4.0 ± 1.8 for the dry and 2.5 ± 1.0 and 3.0 ± 1.1 for the gel-based cap prior and after the EEG recordings, respectively (scale 1-10). Wearing tests indicated that up to 3,200 applications are possible for the dry electrodes. The 256-channel HD-EEG dry electrode cap overcomes the principal limitations of HD-EEG regarding preparation complexity and allows rapid application by not medically trained persons, enabling new use cases for HD-EEG.


Assuntos
Córtex Cerebral/fisiologia , Eletrodos , Eletroencefalografia/instrumentação , Potenciais Evocados Visuais/fisiologia , Adulto , Impedância Elétrica , Eletroencefalografia/métodos , Eletromiografia , Humanos , Monitorização Ambulatorial , Dispositivos Eletrônicos Vestíveis
9.
Proc Natl Acad Sci U S A ; 116(29): 14769-14778, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31189596

RESUMO

Anticipating meaningful actions in the environment is an essential function of the brain. Such predictive mechanisms originate from the motor system and allow for inferring actions from environmental affordances, and the potential to act within a specific environment. Using architecture, we provide a unique perspective on the ongoing debate in cognitive neuroscience and philosophy on whether cognition depends on movement or is decoupled from our physical structure. To investigate cognitive processes associated with architectural affordances, we used a mobile brain/body imaging approach recording brain activity synchronized to head-mounted displays. Participants perceived and acted on virtual transitions ranging from nonpassable to easily passable. We found that early sensory brain activity, on revealing the environment and before actual movement, differed as a function of affordances. In addition, movement through transitions was preceded by a motor-related negative component that also depended on affordances. Our results suggest that potential actions afforded by an environment influence perception.


Assuntos
Cognição/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Movimento/fisiologia , Desempenho Psicomotor/fisiologia , Córtex Sensório-Motor/fisiologia , Adulto , Técnicas de Observação do Comportamento , Sinais (Psicologia) , Eletroencefalografia , Feminino , Humanos , Masculino , Realidade Virtual , Adulto Jovem
10.
Eur J Neurosci ; 54(12): 8421-8440, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32909315

RESUMO

Brain activity during natural walking outdoors can be captured using mobile electroencephalography (EEG). However, EEG recorded during gait is confounded with artifacts from various sources, possibly obstructing the interpretation of brain activity patterns. Currently, there is no consensus on how the amount of artifact present in these recordings should be quantified, or is there a systematic description of gait artifact properties. In the current study, we expand several features into a seven-dimensional footprint of gait-related artifacts, combining features of time, time-frequency, spatial, and source domains. EEG of N = 26 participants was recorded while standing and walking outdoors. Footprints of gait-related artifacts before and after two different artifact attenuation strategies (after artifact subspace reconstruction (ASR) and after subsequent independent component analysis [ICA]) were systematically different. We also evaluated topographies, morphologies, and signal-to-noise ratios (SNR) of button-press event-related potentials (ERP) before and after artifact handling, to confirm gait-artifact reduction specificity. Morphologies and SNR remained unchanged after artifact attenuation, whereas topographies improved in quality. Our results show that the footprint can provide a detailed assessment of gait-related artifacts and can be used to estimate the sensitivity of different artifact reduction strategies. Moreover, the analysis of button-press ERPs demonstrated its specificity, as processing did not only reduce gait-related artifacts but ERPs of interest remained largely unchanged. We conclude that the proposed footprint is well suited to characterize individual differences in gait-related artifact extent. In the future, it could be used to compare and optimize recording setups and processing pipelines comprehensively.


Assuntos
Artefatos , Processamento de Sinais Assistido por Computador , Algoritmos , Encéfalo , Eletroencefalografia/métodos , Marcha , Humanos
11.
Eur J Neurosci ; 54(12): 8214-8224, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32954574

RESUMO

Laboratory electroencephalography (EEG) studies have already provided important insights into the neuronal mechanisms of performance monitoring. However, to our knowledge no study so far has examined neuronal correlates of performance monitoring using an ecologically valid task outside a typical laboratory setting. Therefore, we examined midfrontal theta and the feedback-related negativity (FRN) using mobile EEG in a physical shooting task within an ecologically valid environment with highly dynamical visual feedback. Participants shot a target using a toy gun while moving and looking around freely. Shots that missed the target evoked stronger midfrontal theta activity than hits and this response was rather phase-unlocked. There was no difference between misses and hits in the FRN. The results raise the question whether the absence of certain ERP components like the FRN could be due to methodological reasons or to the fact that partially different neuronal processes may be activated in the laboratory as compared to more ecologically valid tasks. Overall, our results indicate that crucial neurocognitive processes of performance monitoring can be assessed in highly dynamic and ecologically valid settings by mobile EEG.


Assuntos
Lobo Frontal , Ritmo Teta , Eletroencefalografia , Potenciais Evocados/fisiologia , Retroalimentação Sensorial , Lobo Frontal/fisiologia , Humanos , Ritmo Teta/fisiologia
12.
Eur J Neurosci ; 54(12): 8355-8363, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32544262

RESUMO

Neuroscience of dance is an emerging field with important applications related to health and well-being, as dance has shown potential to foster adaptive neuroplasticity and is increasingly popular as a therapeutic activity or adjunct therapy for people living with conditions such as Parkinson's and Alzheimer's diseases. However, the multimodal nature of dance presents challenges to researchers aiming to identify mechanisms involved when dance is used to combat neurodegeneration or support healthy ageing. Requiring simultaneous engagement of motor and cognitive domains, dancing includes coordination of systems involved in timing, memory and spatial learning. Studies on dance to this point rely primarily on assessments of brain dynamics and structure through pre/post-tests or studies on expertise, as traditional brain imaging modalities restrict participant movement to avoid movement-related artefacts. In this paper, we describe the process of designing and implementing a study that uses mobile brain/body imaging (MoBI) to investigate real-time changes in brain dynamics and behaviour during the process of learning and performing a novel dance choreography. We show the potential for new insights to emerge from the coordinated collection of movement and brain-based data, and the implications of these in an emerging field whose medium is motion.


Assuntos
Encéfalo , Movimento , Encéfalo/diagnóstico por imagem , Humanos , Aprendizagem
13.
Eur J Neurosci ; 54(12): 8381-8395, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33185920

RESUMO

It has been stated that active-transmission electrodes should improve signal quality in mobile EEG recordings. However, few studies have directly compared active- and passive-transmission electrodes during a mobile task. In this repeated measurement study, we investigated the performance of active and passive signal transmission electrodes with the same amplifier system in their respective typical configurations, during a mobile auditory task. The task was an auditory discrimination (1,000 vs. 800 Hz; counterbalanced) oddball task using approximately 560 trials (15% targets) for each condition. Eighteen participants performed the auditory oddball task both while standing and walking in an outdoor environment. While walking, there was a significant decrease in P3 amplitude, post-trial rejection trial numbers, and signal-to-noise ratio (SNR). No significant differences were found in signal quality between the two electrode configurations. SNR and P3 amplitude were test-retest reliable between recordings. We conclude that adequate use of a passive EEG electrode system achieves signal quality equivalent to that of an active system during a mobile task.


Assuntos
Eletroencefalografia , Caminhada , Percepção Auditiva , Eletrodos , Humanos
14.
Eur J Neurosci ; 54(12): 8196-8213, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33644960

RESUMO

Recent advancements in portable computer devices have opened new avenues in the study of human cognition outside research laboratories. This flexibility in methodology has led to the publication of several electroencephalography studies recording brain responses in real-world scenarios such as cycling and walking outside. In the present study, we tested the classic auditory oddball task while participants moved around an indoor running track using an electric skateboard. This novel approach allows for the study of attention in motion while virtually removing body movement. Using the skateboard auditory oddball paradigm, we found reliable and expected standard-target differences in the P3 and MMN/N2b event-related potentials. We also recorded baseline electroencephalography activity and found that, compared to this baseline, alpha power is attenuated in frontal and parietal regions during skateboarding. In order to explore the influence of motor interference in cognitive resources during skateboarding, we compared participants' preferred riding stance (baseline level of riding difficulty) versus their non-preferred stance (increased level of riding difficulty). We found that an increase in riding difficulty did not modulate the P3 and tonic alpha amplitude during skateboard motion. These results suggest that increases in motor demands might not lead to reductions in cognitive resources as shown in previous literature.


Assuntos
Patinação , Atenção/fisiologia , Mapeamento Encefálico , Eletroencefalografia/métodos , Potenciais Evocados/fisiologia , Potenciais Evocados Auditivos/fisiologia , Humanos
15.
Eur J Neurosci ; 54(12): 8256-8282, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33738880

RESUMO

Coupling behavioral measures and brain imaging in naturalistic, ecological conditions is key to comprehend the neural bases of spatial navigation. This highly integrative function encompasses sensorimotor, cognitive, and executive processes that jointly mediate active exploration and spatial learning. However, most neuroimaging approaches in humans are based on static, motion-constrained paradigms and they do not account for all these processes, in particular multisensory integration. Following the Mobile Brain/Body Imaging approach, we aimed to explore the cortical correlates of landmark-based navigation in actively behaving young adults, solving a Y-maze task in immersive virtual reality. EEG analysis identified a set of brain areas matching state-of-the-art brain imaging literature of landmark-based navigation. Spatial behavior in mobile conditions additionally involved sensorimotor areas related to motor execution and proprioception usually overlooked in static fMRI paradigms. Expectedly, we located a cortical source in or near the posterior cingulate, in line with the engagement of the retrosplenial complex in spatial reorientation. Consistent with its role in visuo-spatial processing and coding, we observed an alpha-power desynchronization while participants gathered visual information. We also hypothesized behavior-dependent modulations of the cortical signal during navigation. Despite finding few differences between the encoding and retrieval phases of the task, we identified transient time-frequency patterns attributed, for instance, to attentional demand, as reflected in the alpha/gamma range, or memory workload in the delta/theta range. We confirmed that combining mobile high-density EEG and biometric measures can help unravel the brain structures and the neural modulations subtending ecological landmark-based navigation.


Assuntos
Ondas Encefálicas , Navegação Espacial , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Adulto Jovem
16.
Eur J Neurosci ; 54(12): 8336-8354, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33369773

RESUMO

Conducting neuroscience research in the real-world remains challenging because of movement- and environment-related artifacts as well as missing control over stimulus presentation. The present study overcame these restrictions by mobile electroencephalography (EEG) and data-driven analysis approaches during a real-world navigation task. During assisted navigation through an unfamiliar city environment, participants received either standard or landmark-based auditory navigation instructions. EEG data were recorded continuously during navigation. Saccade- and blink-events as well as gait-related EEG activity were extracted from sensor level data. Brain activity associated with the navigation task was identified by subsequent source-based cleaning of non-brain activity and unfolding of overlapping event-related potentials. When navigators received landmark-based instructions compared to those receiving standard navigation instructions, the blink-related brain potentials during navigation revealed higher amplitudes at fronto-central leads in a time window starting at 300 ms after blinks, which was accompanied by improved spatial knowledge acquisition tested in follow-up spatial tasks. Replicating improved spatial knowledge acquisition from previous experiments, the present study revealed eye movement-related brain potentials to point to the involvement of higher cognitive processes and increased processing of incoming information during periods of landmark-based instructions. The study revealed neuronal correlates underlying visuospatial information processing during assisted navigation in the real-world providing a new analysis approach for neuroscientific research in freely moving participants in uncontrollable real-world environments.


Assuntos
Movimentos Oculares , Navegação Espacial , Encéfalo/fisiologia , Mapeamento Encefálico , Eletroencefalografia , Potenciais Evocados , Humanos
17.
Dev Psychobiol ; 63(6): e22128, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34087950

RESUMO

The last decade has seen increased availability of mobile electroencephalography (EEG). These mobile systems enable researchers to conduct data collection "in-context," reducing participant burden and potentially increasing diversity and representation of research samples. Our research team completed in-home data collection from more than 400 twelve-month-old infants from low-income backgrounds using a mobile EEG system. In this paper, we provide methodological and analytic guidance for collecting high-quality, mobile EEG in infants. Specifically, we offer insights and recommendations for equipment selection, data collection, and data analysis, highlighting important considerations for selecting a mobile EEG system. Examples include the size of the recording equipment, electrode type, reference types, and available montages. We also highlight important recommendations surrounding preparing a nonstandardized recording environment for EEG collection, obtaining informed consent from parents, instructions for parents during capping and recording, stimuli and task design, training researchers, and monitoring data as it comes in. Additionally, we provide access to the analysis code and demonstrate the robustness of the data from a recent study using this approach, in which 20 artifact-free epochs achieve good internal consistency reliability. Finally, we provide recommendations and publicly available resources for future studies aiming to collect mobile EEG.


Assuntos
Encéfalo , Eletroencefalografia , Eletroencefalografia/métodos , Estudos de Viabilidade , Humanos , Lactente , Reprodutibilidade dos Testes
18.
Epilepsy Behav ; 103(Pt A): 106507, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31645318

RESUMO

Electroencephalography (EEG) is a core element in the diagnosis of epilepsy syndromes and can help to monitor antiseizure treatment. Mobile EEG (mEEG) devices are increasingly available on the consumer market and may offer easier access to EEG recordings especially in rural or resource-poor areas. The usefulness of consumer-grade devices for clinical purposes is still underinvestigated. Here, we compared EEG traces of a commercially available mEEG device (Emotiv EPOC) to a simultaneously recorded clinical video EEG (vEEG). Twenty-two adult patients (11 female, mean age 40.2 years) undergoing noninvasive vEEG monitoring for clinical purposes were prospectively enrolled. The EEG recordings were evaluated by 10 independent raters with unmodifiable view settings. The individual evaluations were compared with respect to the presence of abnormal EEG findings (regional slowing, epileptiform potentials, seizure pattern). Video EEG yielded a sensitivity of 56% and specificity of 88% for abnormal EEG findings, whereas mEEG reached 39% and 85%, respectively. Interrater reliability coefficients were better in vEEG as compared to mEEG (ϰ = 0.50 vs. 0.30), corresponding to a moderate and fair agreement. Intrarater reliability between mEEG and vEEG evaluations of simultaneous recordings of a given participant was moderate (ϰ = 0.48). Given the limitations of our exploratory pilot study, our results suggest that vEEG is superior to mEEG, but that mEEG can be helpful for diagnostic purposes. We present the first quantitative comparison of simultaneously acquired clinical and mobile consumer-grade EEG for a clinical use-case.


Assuntos
Eletroencefalografia , Síndromes Epilépticas/diagnóstico , Monitorização Ambulatorial , Convulsões/diagnóstico , Dispositivos Eletrônicos Vestíveis , Adulto , Eletroencefalografia/instrumentação , Eletroencefalografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/normas , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dispositivos Eletrônicos Vestíveis/normas
19.
Sensors (Basel) ; 20(6)2020 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-32183285

RESUMO

Optimizing neurofeedback (NF) and brain-computer interface (BCI) implementations constitutes a challenge across many fields and has so far been addressed by, among others, advancing signal processing methods or predicting the user's control ability from neurophysiological or psychological measures. In comparison, how context factors influence NF/BCI performance is largely unexplored. We here investigate whether a competitive multi-user condition leads to better NF/BCI performance than a single-user condition. We implemented a foot motor imagery (MI) NF with mobile electroencephalography (EEG). Twenty-five healthy, young participants steered a humanoid robot in a single-user condition and in a competitive multi-user race condition using a second humanoid robot and a pseudo competitor. NF was based on 8-30 Hz relative event-related desynchronization (ERD) over sensorimotor areas. There was no significant difference between the ERD during the competitive multi-user condition and the single-user condition but considerable inter-individual differences regarding which condition yielded a stronger ERD. Notably, the stronger condition could be predicted from the participants' MI-induced ERD obtained before the NF blocks. Our findings may contribute to enhance the performance of NF/BCI implementations and highlight the necessity of individualizing context factors.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia/métodos , Imagens, Psicoterapia/métodos , Robótica/tendências , Adulto , Feminino , Humanos , Masculino , Neurorretroalimentação/métodos , Córtex Sensório-Motor/fisiologia , Processamento de Sinais Assistido por Computador , Adulto Jovem
20.
Neuroimage ; 193: 1-9, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30862534

RESUMO

Episodic memory supports recognition of the details of complex real world experiences, providing a continuous record of events embedded within spatial and temporal context. Despite the inherently dynamic nature of real events, the bulk of neuroscientific research to date examines recognition in absence of the detailed contextual information that is known to be a defining characteristic. Given the importance of environmental context for episodic memory, examining ERP correlates of memory in more naturalistic settings is vital for progress in understanding how retrieval operates in daily life. The current study capitalized on recent advances in mobile EEG technology to address this issue and is the first to investigate ERP correlates of episodic retrieval in real world contexts. Participants were guided around a pre-defined route inside a building on campus, while performing a recognition memory task, which paired images of objects with actual physical locations in the building to provide context. Importantly, the findings clearly demonstrate that it is possible to observe reliable neural correlates of memory in real world contexts. Replicating two well established ERP correlates of episodic retrieval reported in prior laboratory based studies, we detected FN400 old/new effects traditionally associated with familiarity between 300 and 500 ms, and a late posterior negativity (LPN) often linked to reconstructive processing or evaluation of retrieval outcomes between 500 and 800 ms. Moreover, the FN400 effect was found to be sensitive to retrieval of context, with more sustained effects for objects encountered in a different context at study and test. Overall, the current work highlights the power of mobile EEG technology for examining complex cognitive functions in more naturalistic real world settings.


Assuntos
Encéfalo/fisiologia , Eletroencefalografia/métodos , Memória Episódica , Adolescente , Adulto , Eletroencefalografia/instrumentação , Potenciais Evocados/fisiologia , Feminino , Humanos , Masculino , Monitorização Neurofisiológica/instrumentação , Monitorização Neurofisiológica/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA