Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.315
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 121(5): e2309384121, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38252835

RESUMO

High-quality specimen preparation plays a crucial role in cryo-electron microscopy (cryo-EM) structural analysis. In this study, we have developed a reliable and convenient technique called the graphene sandwich method for preparing cryo-EM specimens. This method involves using two layers of graphene films that enclose macromolecules on both sides, allowing for an appropriate ice thickness for cryo-EM analysis. The graphene sandwich helps to mitigate beam-induced charging effect and reduce particle motion compared to specimens prepared using the traditional method with graphene support on only one side, therefore improving the cryo-EM data quality. These advancements may open new opportunities to expand the use of graphene in the field of biological electron microscopy.


Assuntos
Grafite , Microscopia Crioeletrônica , Confiabilidade dos Dados , Movimento (Física)
2.
Trends Genet ; 39(9): 686-702, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37365103

RESUMO

Metatranscriptomics refers to the analysis of the collective microbial transcriptome of a sample. Its increased utilization for the characterization of human-associated microbial communities has enabled the discovery of many disease-state related microbial activities. Here, we review the principles of metatranscriptomics-based analysis of human-associated microbial samples. We describe strengths and weaknesses of popular sample preparation, sequencing, and bioinformatics approaches and summarize strategies for their use. We then discuss how human-associated microbial communities have recently been examined and how their characterization may change. We conclude that metatranscriptomics insights into human microbiotas under health and disease have not only expanded our knowledge on human health, but also opened avenues for rational antimicrobial drug use and disease management.


Assuntos
Metagenômica , Microbiota , Humanos , Microbiota/genética , Transcriptoma/genética , Sequenciamento de Nucleotídeos em Larga Escala
3.
Mol Syst Biol ; 20(8): 972-995, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38907068

RESUMO

Mass spectrometry has revolutionized cell signaling research by vastly simplifying the analysis of many thousands of phosphorylation sites in the human proteome. Defining the cellular response to perturbations is crucial for further illuminating the functionality of the phosphoproteome. Here we describe µPhos ('microPhos'), an accessible phosphoproteomics platform that permits phosphopeptide enrichment from 96-well cell culture and small tissue amounts in <8 h total processing time. By greatly minimizing transfer steps and liquid volumes, we demonstrate increased sensitivity, >90% selectivity, and excellent quantitative reproducibility. Employing highly sensitive trapped ion mobility mass spectrometry, we quantify ~17,000 Class I phosphosites in a human cancer cell line using 20 µg starting material, and confidently localize ~6200 phosphosites from 1 µg. This depth covers key signaling pathways, rendering sample-limited applications and perturbation experiments with hundreds of samples viable. We employ µPhos to study drug- and time-dependent response signatures in a leukemia cell line, and by quantifying 30,000 Class I phosphosites in the mouse brain we reveal distinct spatial kinase activities in subregions of the hippocampal formation.


Assuntos
Fosfopeptídeos , Fosfoproteínas , Proteômica , Proteômica/métodos , Humanos , Animais , Camundongos , Fosfoproteínas/metabolismo , Fosforilação , Linhagem Celular Tumoral , Fosfopeptídeos/metabolismo , Fosfopeptídeos/análise , Espectrometria de Massas/métodos , Transdução de Sinais , Proteoma/metabolismo , Reprodutibilidade dos Testes , Hipocampo/metabolismo , Hipocampo/citologia
4.
Mol Cell Proteomics ; 22(12): 100665, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37839701

RESUMO

Multiplexed and label-free mass spectrometry-based approaches with single-cell resolution have attributed surprising heterogeneity to presumed homogenous cell populations. Even though specialized experimental designs and instrumentation have demonstrated remarkable advances, the efficient sample preparation of single cells still lags. Here, we introduce the proteoCHIP, a universal option for single-cell proteomics sample preparation including multiplexed labeling up to 16-plex with high sensitivity and throughput. The automated processing using a commercial system combining single-cell isolation and picoliter dispensing, the cellenONE, reduces final sample volumes to low nanoliters submerged in a hexadecane layer simultaneously eliminating error-prone manual sample handling and overcoming evaporation. The specialized proteoCHIP design allows direct injection of single cells via a standard autosampler resulting in around 1500 protein groups per TMT10-plex with reduced or eliminated need for a carrier proteome. We evaluated the effect of wider precursor isolation windows at single-cell input levels and found that using 2 Da isolation windows increased overall sensitivity without significantly impacting interference. Using the dedicated mass spectrometry acquisition strategies detailed here, we identified on average close to 2000 proteins per TMT10-plex across 170 multiplexed single cells that readily distinguished human cell types. Overall, our workflow combines highly efficient sample preparation, chromatographic and ion mobility-based filtering, rapid wide-window data-dependent acquisition analysis, and intelligent data analysis for optimal multiplexed single-cell proteomics. This versatile and automated proteoCHIP-based sample preparation approach is sufficiently sensitive to drive biological applications of single-cell proteomics and can be readily adopted by proteomics laboratories.


Assuntos
Proteoma , Proteômica , Humanos , Proteômica/métodos , Fluxo de Trabalho , Espectrometria de Massas/métodos , Proteoma/metabolismo
5.
Proteomics ; 24(8): e2300134, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37679057

RESUMO

Contaminants derived from consumables, reagents, and sample handling often negatively affect LC-MS data acquisition. In proteomics experiments, they can markedly reduce identification performance, reproducibility, and quantitative robustness. Here, we introduce a data analysis workflow combining MS1 feature extraction in Skyline with HowDirty, an R-markdown-based tool, that automatically generates an interactive report on the molecular contaminant level in LC-MS data sets. To facilitate the interpretation of the results, the HTML report is self-contained and self-explanatory, including plots that can be easily interpreted. The R package HowDirty is available from https://github.com/DavidGZ1/HowDirty. To demonstrate a showcase scenario for the application of HowDirty, we assessed the impact of ultrafiltration units from different providers on sample purity after filter-assisted sample preparation (FASP) digestion. This allowed us to select the filter units with the lowest contamination risk. Notably, the filter units with the lowest contaminant levels showed higher reproducibility regarding the number of peptides and proteins identified. Overall, HowDirty enables the efficient evaluation of sample quality covering a wide range of common contaminant groups that typically impair LC-MS analyses, facilitating corrective or preventive actions to minimize instrument downtime.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Proteínas/análise
6.
Proteomics ; 24(10): e2300339, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38299459

RESUMO

Detergent-based workflows incorporating sodium dodecyl sulfate (SDS) necessitate additional steps for detergent removal ahead of mass spectrometry (MS). These steps may lead to variable protein recovery, inconsistent enzyme digestion efficiency, and unreliable MS signals. To validate a detergent-based workflow for quantitative proteomics, we herein evaluate the precision of a bottom-up sample preparation strategy incorporating cartridge-based protein precipitation with organic solvent to deplete SDS. The variance of data-independent acquisition (SWATH-MS) data was isolated from sample preparation error by modelling the variance as a function of peptide signal intensity. Our SDS-assisted cartridge workflow yield a coefficient of variance (CV) of 13%-14%. By comparison, conventional (detergent-free) in-solution digestion increased the CV to 50%; in-gel digestion provided lower CVs between 14% and 20%. By filtering peptides predicting to display lower precision, we further enhance the validity of data in global comparative proteomics. These results demonstrate the detergent-based precipitation workflow is a reliable approach for in depth, label-free quantitative proteome analysis.


Assuntos
Precipitação Química , Detergentes , Proteômica , Dodecilsulfato de Sódio , Fluxo de Trabalho , Proteômica/métodos , Dodecilsulfato de Sódio/química , Detergentes/química , Proteoma/análise , Proteoma/química , Humanos , Peptídeos/química , Peptídeos/análise
7.
J Proteome Res ; 23(3): 869-880, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353246

RESUMO

The metaproteomic approach is an attractive way to describe a microbiome at the functional level, allowing the identification and quantification of proteins across a broad dynamic range as well as the detection of post-translational modifications. However, it remains relatively underutilized, mainly due to technical challenges that should be addressed, including the complexity of extracting proteins from heterogeneous microbial communities. Here, we show that a ChipFilter microfluidic device coupled to a liquid chromatography tandem mass spectrometry (LC-MS/MS) setup can be successfully used for the identification of microbial proteins. Using cultures of Escherichia coli, Bacillus subtilis, and Saccharomyces cerevisiae, we have shown that it is possible to directly lyse the cells and digest the proteins in the ChipFilter to allow the identification of a higher number of proteins and peptides than that by standard protocols, even at low cell density. The peptides produced are overall longer after ChipFilter digestion but show no change in their degree of hydrophobicity. Analysis of a more complex mixture of 17 species from the gut microbiome showed that the ChipFilter preparation was able to identify and estimate the amounts of 16 of these species. These results show that ChipFilter can be used for the proteomic study of microbiomes, particularly in the case of a low volume or cell density. The mass spectrometry data have been deposited on the ProteomeXchange Consortium via the PRIDE partner repository with the data set identifier PXD039581.


Assuntos
Consórcios Microbianos , Microfluídica , Cromatografia Líquida , Proteômica , Espectrometria de Massas em Tandem , Escherichia coli/genética , Saccharomyces cerevisiae/genética , Peptídeos
8.
J Proteome Res ; 23(9): 3877-3889, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39161190

RESUMO

The goal of proteomics experiments is to identify proteins to observe changes in cellular processes and diseases. One challenge in proteomics is the removal of contaminants following protein extraction, which can limit protein identifications. Single-pot, solid-phase-enhanced sample preparation (SP3) is a cleanup technique in which proteins are captured on carboxylate-modified particles through a proposed hydrophilic-interaction-liquid-chromatography (HILIC)-like mechanism. Recent results have suggested that proteins are captured in SP3 due to a protein-aggregation mechanism. Solvent precipitation, single-pot, solid-phase-enhanced sample preparation (SP4) is a newer cleanup technique that employs protein aggregation to capture proteins without modified particles. We hypothesize that differences in capture mechanisms of SP3 and SP4 affect which proteins are identified by each cleanup technique. Herein, we assess the proteins identified and enriched using SP3 versus SP4 for MCF7 subcellular fractions and correlate protein capture in each method to protein hydrophobicity. Our results indicate that SP3 captures more hydrophilic proteins through a combination of HILIC-like and protein-aggregation mechanisms, while SP4 captures more hydrophobic proteins through a protein-aggregation mechanism. Ultimately, we demonstrate that protein-capture mechanisms are distinct, and the selection of a cleanup technique that yields high proteome coverage is dependent on protein-sample hydrophobicity. Data has been deposited into MassIVE (MSV000094130) and ProteomeXchange (PXD049965).


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Proteômica , Proteômica/métodos , Humanos , Cromatografia Líquida/métodos , Células MCF-7 , Proteínas/química , Proteínas/isolamento & purificação , Proteínas/análise , Proteínas/metabolismo , Agregados Proteicos
9.
J Proteome Res ; 23(8): 3294-3309, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39038167

RESUMO

Compared to advancements in single-cell proteomics, phosphoproteomics sensitivity has lagged behind due to low abundance, complex sample preparation, and substantial sample input requirements. We present a simple and rapid one-pot phosphoproteomics workflow (SOP-Phos) integrated with data-independent acquisition mass spectrometry (DIA-MS) for microscale phosphoproteomic analysis. SOP-Phos adapts sodium deoxycholate based one-step lysis, reduction/alkylation, direct trypsinization, and phosphopeptide enrichment by TiO2 beads in a single-tube format. By reducing surface adsorptive losses via utilizing n-dodecyl ß-d-maltoside precoated tubes and shortening the digestion time, SOP-Phos is completed within 3-4 h with a 1.4-fold higher identification coverage. SOP-Phos coupled with DIA demonstrated >90% specificity, enhanced sensitivity, lower missing values (<1%), and improved reproducibility (8%-10% CV). With a sample size-comparable spectral library, SOP-Phos-DIA identified 33,787 ± 670 to 22,070 ± 861 phosphopeptides from 5 to 0.5 µg cell lysate and 30,433 ± 284 to 6,548 ± 21 phosphopeptides from 50,000 to 2,500 cells. Such sensitivity enabled mapping key lung cancer signaling sites, such as EGFR autophosphorylation sites Y1197/Y1172 and drug targets. The feasibility of SOP-Phos-DIA was demonstrated on EGFR-TKI sensitive and resistant cells, revealing the interplay of multipathway Hippo-EGFR-ERBB signaling cascades underlying the mechanistic insight into EGFR-TKI resistance. Overall, SOP-Phos-DIA is an efficient and robust protocol that can be easily adapted in the community for microscale phosphoproteomic analysis.


Assuntos
Fosfopeptídeos , Fosfoproteínas , Proteômica , Fluxo de Trabalho , Proteômica/métodos , Humanos , Fosfopeptídeos/análise , Fosfopeptídeos/química , Fosfopeptídeos/metabolismo , Fosfoproteínas/metabolismo , Fosfoproteínas/análise , Fosfoproteínas/química , Reprodutibilidade dos Testes , Receptores ErbB/metabolismo , Linhagem Celular Tumoral , Fosforilação , Titânio/química , Neoplasias Pulmonares/metabolismo , Espectrometria de Massas/métodos
10.
J Proteome Res ; 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39374182

RESUMO

Photoaffinity labeling (PAL) methodologies have proven to be instrumental for the unbiased deconvolution of protein-ligand binding events in physiologically relevant systems. However, like other chemical proteomic workflows, they are limited in many ways by time-intensive sample manipulations and data acquisition techniques. Here, we describe an approach to address this challenge through the innovation of a carboxylate bead-based protein cleanup procedure to remove excess small-molecule contaminants and couple it to plate-based, proteomic sample processing as a semiautomated solution. The analysis of samples via label-free, data-independent acquisition (DIA) techniques led to significant improvements on a workflow time per sample basis over current standard practices. Experiments utilizing three established PAL ligands with known targets, (+)-JQ-1, lenalidomide, and dasatinib, demonstrated the utility of having the flexibility to design experiments with a myriad of variables. Data revealed that this workflow can enable the confident identification and rank ordering of known and putative targets with outstanding protein signal-to-background enrichment sensitivity. This unified end-to-end throughput strategy for processing and analyzing these complex samples could greatly facilitate efficient drug discovery efforts and open up new opportunities in the chemical proteomics field.

11.
J Proteome Res ; 23(10): 4392-4408, 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39248652

RESUMO

A thorough evaluation of the quality, reproducibility, and variability of bottom-up proteomics data is necessary at every stage of a workflow, from planning to analysis. We share vignettes applying adaptable quality control (QC) measures to assess sample preparation, system function, and quantitative analysis. System suitability samples are repeatedly measured longitudinally with targeted methods, and we share examples where they are used on three instrument platforms to identify severe system failures and track function over months to years. Internal QCs incorporated at the protein and peptide levels allow our team to assess sample preparation issues and to differentiate system failures from sample-specific issues. External QC samples prepared alongside our experimental samples are used to verify the consistency and quantitative potential of our results during batch correction and normalization before assessing biological phenotypes. We combine these controls with rapid analysis (Skyline), longitudinal QC metrics (AutoQC), and server-based data deposition (PanoramaWeb). We propose that this integrated approach to QC is a useful starting point for groups to facilitate rapid quality control assessment to ensure that valuable instrument time is used to collect the best quality data possible. Data are available on Panorama Public and ProteomeXchange under the identifier PXD051318.


Assuntos
Proteômica , Controle de Qualidade , Proteômica/métodos , Proteômica/normas , Reprodutibilidade dos Testes , Humanos , Fluxo de Trabalho , Peptídeos/análise , Peptídeos/normas
12.
Small ; 20(26): e2310700, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38483007

RESUMO

Single-cell mass spectrometry (MS) is significant in biochemical analysis and holds great potential in biomedical applications. Efficient sample preparation like sorting (i.e., separating target cells from the mixed population) and desalting (i.e., moving the cells off non-volatile salt solution) is urgently required in single-cell MS. However, traditional sample preparation methods suffer from complicated operation with various apparatus, or insufficient performance. Herein, a one-step sample preparation strategy by leveraging label-free impedance flow cytometry (IFC) based microfluidics is proposed. Specifically, the IFC framework to characterize and sort single-cells is adopted. Simultaneously with sorting, the target cell is transferred from the local high-salinity buffer to the MS-compatible solution. In this way, one-step sorting and desalting are achieved and the collected cells can be directly fed for MS analysis. A high sorting efficiency (>99%), cancer cell purity (≈87%), and desalting efficiency (>99%), and the whole workflow of impedance-based separation and MS analysis of normal cells (MCF-10A) and cancer cells (MDA-MB-468) are verified. As a standalone sample preparation module, the microfluidic chip is compatible with a variety of MS analysis methods, and envisioned to provide a new paradigm in efficient MS sample preparation, and further in multi-modal (i.e., electrical and metabolic) characterization of single-cells.


Assuntos
Impedância Elétrica , Citometria de Fluxo , Espectrometria de Massas , Microfluídica , Análise de Célula Única , Análise de Célula Única/métodos , Humanos , Citometria de Fluxo/métodos , Espectrometria de Massas/métodos , Microfluídica/métodos , Linhagem Celular Tumoral
13.
J Clin Microbiol ; : e0043424, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39297624

RESUMO

The MBT Pathfinder is an automated colony-picking robot designed for efficient sample preparation in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. This article presents results from three key experiments evaluating the instrument's performance in conjunction with MALDI Biotyper instrument. The method comparison experiment assessed its clinical performance, demonstrating comparable results with gram-positive, gram-negative, and anaerobic bacteria (scores larger than 2.00) and superior performance over simple direct yeast transfer (score: 1.80) when compared to samples prepared manually. The repeatability experiment confirmed consistent performance over multiple days and labs (average log score: 2.12, std. deviation: 0.59). The challenge panel experiment showcased its consistent and accurate performance across various samples and settings, yielding average scores between 1.76 and 2.19. These findings underline the MBT Pathfinder as a reliable and efficient tool for MALDI-TOF mass spectrometry sample preparation in clinical and research applications.

14.
Biochem Soc Trans ; 52(3): 1529-1537, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38864435

RESUMO

Sample preparation can present a significant hurdle within single particle cryo-electron microscopy (cryoEM), resulting in issues with reproducibility, data quality or an inability to visualise the sample. There are several factors which can influence this, including sample or buffer composition, grid type, route of sample preparation and interactions with the air-water interface (AWI). Here, we review some of the current routes for sample preparation and the associated challenges. We discuss a range of approaches for overcoming these challenges, such as minimising the grid preparation time, surfactants, grid type and biochemical approaches such as nanomagnetic beads. Finally, we discuss how a set of commercially available protein samples may serve as a benchmark suite for future technologies. This provides a route to compare techniques' abilities not just to generate high-resolution structures but also to overcome the challenges traditionally associated with cryoEM. As the field continues to produce new approaches to sample preparation and we start to better understand the underlying principles behind the behaviour of proteins within a thin film and in response to different environments, especially grid composition, it is hoped that more universal solutions can be provided that make the intractable systems tractable, improve resolution and, importantly, speed up data collection and reduce the currently required dataset sizes.


Assuntos
Microscopia Crioeletrônica , Proteínas , Microscopia Crioeletrônica/métodos , Proteínas/química , Manejo de Espécimes/métodos
15.
Mass Spectrom Rev ; 42(5): 1589-1603, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34642960

RESUMO

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an excellent tool for bacterial identification. It allows high throughput, sensitive and specific applications in clinical diagnostics and environmental research. Currently, there is no optimal standardized protocol for sample preparation and culture conditions to profile bacteria. The performance of MALDI-TOF MS is affected by several variables, such as sample preparation, culture media and culture conditions, incubation time/growth stage, incubation temperature, high salt content, blood in the culture media, and others. This review thus aims to clarify why a uniformed protocol is not plausible, to assess the effects these factors have on MALDI-TOF MS identification score, and discuss possible optimizations for its methodology, in relation to specific bacterial representatives and strain requirements.

16.
Mass Spectrom Rev ; 42(2): 873-886, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34786750

RESUMO

Sample preparation for mass spectrometry-based proteomics has many tedious and time-consuming steps that can introduce analytical errors. In particular, the steps around the proteolytic digestion of protein samples are prone to inconsistency. One route for reliable sample processing is the development and optimization of a workflow utilizing an automated liquid handling workstation. Diligent assessment of the sample type, protocol design, reagents, and incubation conditions can significantly improve the speed and consistency of preparation. When combining robust liquid chromatography-mass spectrometry with either discovery or targeted methods, automated sample preparation facilitates increased throughput and reproducible quantitation of biomarker candidates. These improvements in analysis are also essential to process the large patient cohorts necessary to validate a candidate biomarker for potential clinical use. This article reviews the steps in the workflow, optimization strategies, and known applications in clinical, pharmaceutical, and research fields that demonstrate the broad utility for improved automation of sample preparation in the proteomic field.


Assuntos
Proteínas , Proteômica , Humanos , Proteômica/métodos , Espectrometria de Massas/métodos , Biomarcadores , Manejo de Espécimes
17.
Mass Spectrom Rev ; 42(5): 1647-1687, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34967037

RESUMO

Liquid chromatography/tandem mass spectrometry is firmly established today as the gold standard technique for analysis of vitamin D, both for vitamin D status assessments as well as for measuring complex and intricate vitamin D metabolic fingerprints. While the actual mass spectrometry technology has seen only incremental performance increases in recent years, there have been major, very impactful changes in the front- and back-end of MS-based vitamin D assays; for example, the extension to new types of biological sample matrices analyzed for an increasing number of different vitamin D metabolites, novel sample preparation techniques, new powerful chemical derivatization reagents, as well the continued integration of high resolution mass spectrometers into clinical laboratories, replacing established triple-quadrupole instruments. At the same time, the sustainability of mass spectrometry operation in the vitamin D field is now firmly established through proven analytical harmonization and standardization programs. The present review summarizes the most important of these recent developments.

18.
Electrophoresis ; 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39345230

RESUMO

Capillary electrophoresis (CE) is a powerful analysis technique with advantages such as high separation efficiency with resolution factors above 1.5, low sample consumption of less than 10 µL, cost-effectiveness, and eco-friendliness such as reduced solvent use and lower operational costs. However, CE also faces limitations, including limited detection sensitivity for low-concentration samples and interference from complex biological matrices. Prior to performing CE, it is common to utilize sample preparation procedures such as solid-phase microextraction (SPME) and liquid-phase microextraction (LPME) in order to improve the sensitivity and selectivity of the analysis. Recently, there have been advancements in the development of novel materials that have the potential to greatly enhance the performance of SPME and LPME. This review examines various materials and their uses in microextraction when combined with CE. These materials include carbon nanotubes, covalent organic frameworks, metal-organic frameworks, graphene and its derivatives, molecularly imprinted polymers, layered double hydroxides, ionic liquids, and deep eutectic solvents. The utilization of these innovative materials in extraction methods is being examined. Analyte recoveries and detection limits attained for a range of sample matrices are used to assess their effects on extraction selectivity, sensitivity, and efficiency. Exploring new materials for use in sample preparation techniques is important as it enables researchers to address current limitations of CE. The development of novel materials has the potential to greatly enhance extraction selectivity, sensitivity, and efficiency, thereby improving CE performance for complex biological analysis.

19.
J Exp Bot ; 75(17): 5295-5311, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-38938164

RESUMO

Due to technological advances in mass spectrometry, significant progress has been achieved recently in plant hormone research. Nowadays, plant hormonomics is well established as a fully integrated scientific field focused on the analysis of phytohormones, mainly on their isolation, identification, and spatiotemporal quantification in plants. This review represents a comprehensive meta-study of the advances in the phytohormone analysis by mass spectrometry over the past decade. To address current trends and future perspectives, Web of Science data were systematically collected and key features such as mass spectrometry-based analyses were evaluated using multivariate data analysis methods. Our findings showed that plant hormonomics is currently divided into targeted and untargeted approaches. Both aim to miniaturize the sample, allowing high-resolution quantification to be covered in plant organs as well as subcellular compartments. Therefore, we can study plant hormone biosynthesis, metabolism, and signalling at a spatio-temporal resolution. Moreover, this trend has recently been accelerated by technological advances such as fluorescence-activated cell sorting or mass spectrometry imaging.


Assuntos
Espectrometria de Massas , Reguladores de Crescimento de Plantas , Reguladores de Crescimento de Plantas/metabolismo , Plantas/metabolismo , Hormese
20.
Metabolomics ; 20(2): 38, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38460055

RESUMO

INTRODUCTION: Changes in the categories and concentrations of salivary metabolites may be closely related to oral, intestinal or systemic diseases. To study salivary metabolites, the first analytical step is to extract them from saliva samples as much as possible, while reducing interferences to a minimum. Frequently used extraction methods are protein precipitation (PPT), liquid-liquid extraction (LLE) and solid-phase extraction (SPE), with various organic solvents. The types and quantities of metabolites extracted with different methods may vary greatly, but few studies have systematically evaluated them. OBJECTIVES: This study aimed to select the most suitable methods and solvents for the extraction of saliva according to different analytical targets. METHODS: An untargeted metabolomics approach based on liquid chromatography-mass spectrometry was applied to obtain the raw data. The numbers of metabolites, repeatability of the data and intensities of mass spectrometry signals were used as evaluation criteria. RESULTS: PPT resulted in the highest coverage. Among the PPT solvents, acetonitrile displayed the best repeatability and the highest coverage, while acetone resulted in the best signal intensities for the extracted compounds. LLE with the mixture of chloroform and methanol was the most suitable for the extraction of small hydrophobic compounds. CONCLUSION: PPT with acetonitrile or acetone was recommended for untargeted analysis, while LLE with the mixture of chloroform and methanol was recommended for small hydrophobic compounds.


Assuntos
Metabolômica , Metanol , Solventes/química , Metabolômica/métodos , Metanol/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Clorofórmio , Acetona , Saliva , Acetonitrilas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA