Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 708
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Echocardiography ; 41(1): e15741, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284687

RESUMO

A 58-year-old male patient was admitted with chest pain and was diagnosed with coronary heart disease. He was scheduled for coronary artery bypass grafting (CABG) under cardiopulmonary bypass (CPB). Intraoperative real-time transesophageal echocardiography (TEE) showed that the tricuspid valves were well-aligned and subtle regurgitation. Real-time TEE after separation from CPB showed severe tricuspid regurgitation and prolapsed chordae tendineae. The tricuspid chordae tendineae rupture due to a right atrial venous return cannula. The use of negative pressure to improve venous drainage during CPB may result in the tricuspid valve being adsorbed to the cannula, increasing the likelihood of injury to the tricuspid valve.


Assuntos
Ruptura Cardíaca , Doenças das Valvas Cardíacas , Insuficiência da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Ecocardiografia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Ruptura , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Cordas Tendinosas/lesões , Ponte de Artéria Coronária/efeitos adversos
2.
Int Heart J ; 65(1): 128-134, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296565

RESUMO

Transapical beating-heart mitral repair with chordal implantation system has been considered as an alternative treatment for degenerative mitral regurgitation. This study aimed to assess the feasibility and safety of the E-Chord system (Med-Zenith Medical, Beijing, China) for transapical beating-heart mitral valve repair in a porcine model. Artificial chordae were transapically implanted on the mitral valves of 12 anesthetized pigs under epicardial echocardiographic guidance and secured outside the left ventricular apex. The study endpoints included procedural success, device durability, and tissue response to the device. The procedural success rate was 100% (12/12). All animals were implanted with E-Chord in the anterior and posterior leaflets, respectively, and survived uneventfully until euthanized as planned. During the 180-day follow-up, no animal had significant mitral valve dysfunction. The gross observation showed no evidence of anchor detachment and chordal rupture, and there was no obvious damage or changes to mitral leaflets. Microscopic evaluation revealed that the endothelialization of anchor and chordae was completed 90 days after implantation and there was no evidence of chordal rupture, thrombosis, or infection during the 180-day follow-up. The E-Chord system was found to be feasible and safe for heart-beating mitral chordal implantation in a porcine model. The findings of this study suggest that the E-Chord system may be a potential alternative for the treatment of degenerative mitral regurgitation in humans.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Suínos , Animais , Insuficiência da Valva Mitral/cirurgia , Estudos de Viabilidade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Cordas Tendinosas/cirurgia , Resultado do Tratamento
3.
Kyobu Geka ; 77(3): 184-189, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465490

RESUMO

Acute rupture of the chordae tendineae of the mitral valve could lead to severe mitral regurgitation and circulatory collapse in infants. Mitral valve replacement may be often challenging because of the valve-annulus size mismatch in small infants when mitral valve repair cannot be accomplished. We present an infant with acute massive rupture of the chordae tendineae of the mitral valve who successfully underwent supra-annular mitral valve replacement using the short composite valve of an expanded polytetrafluoroethylene( ePTFE) graft and a mechanical valve. His mechanical valve has been functioning without complications such as thrombosis and pulmonary venous obstruction for 20 months after surgery. This technique could be helpful even infants with acute rupture of the chordae tendineae of the mitral valve whose left atrium may not be dilated.


Assuntos
Cordas Tendinosas , Insuficiência da Valva Mitral , Lactente , Humanos , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Catéteres
4.
Morphologie ; 107(356): 147-150, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35787342

RESUMO

Knowledge of anatomical variations of the heart are important to cardiac surgeons, cardiologists, and radiologist. During routine dissection of a 77-year-old male cadaver, we observed an unusual origin of a papillary muscle of the right ventricle arising from the atrioventricular aspect of the moderator band. This papillary muscle was 6.7mm long and 2.6mm wide. It gave rise to two chordae tendineae: one to the inferior (posterior) papillary muscle of the right ventricle and one directly to the inferior (posterior) leaflet of the tricuspid valve. Variants of the internal anatomy of the heart as exemplified in the present case report should be born in mind during image interpretation and invasive procedures of the right ventricle of the heart.


Assuntos
Ventrículos do Coração , Músculos Papilares , Masculino , Humanos , Idoso , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/anatomia & histologia , Músculos Papilares/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Cordas Tendinosas/fisiologia , Cordas Tendinosas/cirurgia , Valva Tricúspide/fisiologia , Valva Tricúspide/cirurgia , Cadáver
5.
BMC Cardiovasc Disord ; 22(1): 551, 2022 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-36528554

RESUMO

BACKGROUND: To compare the early and late postoperative outcomes of chordal reconstruction (CR) and quadrangular resection (QR) in patients with posterior mitral valve prolapse (PMPL). METHODS: Between January 2008 and December 2018, 305 patients with PMPL who underwent mitral valve plasty (MVP) were included in this retrospective analysis. The CR and QR procedures were performed in 169 patients (CR group) and 136 patients (QR group), respectively. Early and late postoperative outcomes were compared between the groups. RESULTS: Follow-up was complete in 96.4% (294/305) of patients, with a mean follow-up of 81.2 ± 30.4 months. No 30-day mortality was observed in any of the patients. The success rate of the mitral valve repair was similar in both groups (99.4% vs. 98.5%, P = 0.850). The incidence of early postoperative hemolysis was lower in the CR group than in the QR group (0.00% vs. 3.0%, P = 0.024). Postoperative left ventricular end-diastolic diameter (LVEDD) decreased more significantly in the CR group than in the QR group at 3 months (8.15 [1.30,12.65] vs. 3.25 [- 0.05, 8.75] mm, P < 0.001). During follow-up, the overall survival rates were 95.1% and 94.6% in the CR and QR groups, respectively. The incidence of reoperation for moderate or severe mitral regurgitation (MR) was similar in both groups (4.3% vs.5.4%, P = 0.653), but the time interval between the initial operation and reoperation was shorter in the QR group than in the CR group (84.3 ± 36.1 vs. 120.9 ± 27.6 months, P = 0.026). The LVEDD enlargement was more significant in the QR group than in the CR group (4.5 [3.6, 4.5] vs. 2.4 [1.3, 2.8] mm, P < 0.001). CONCLUSION: CR and QR are effective techniques for patients with PMPL. Both techniques resulted in a low incidence of recurrent MR. However, CR can reduce early postoperative hemolysis and LVEDD more significantly. During the long-term follow-up, reoperations due to recurrent MR were performed at a longer interval after the initial operation. LVEDD expansion was better avoided in the CR group.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Estudos Retrospectivos , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Hemólise , Resultado do Tratamento , Seguimentos
6.
Echocardiography ; 39(1): 101-103, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34866243

RESUMO

A 65-year-old female with severe mitral regurgitation presenting for mitral valve replacement was found to have a previously undiagnosed aberrant papillary muscle with thickened chordae tendineae inserting into the basal septum during intra-operative TEE. Despite its anatomic location, there was no evidence that the aberrant papillary muscle was contributing to the mitral regurgitation or causing left ventricular outflow tract (LVOT) obstruction. The aberrant papillary muscle was resected during the operation and the patient was separated from cardiopulmonary bypass without complications.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Idoso , Cardiomiopatia Hipertrófica/complicações , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Ecocardiografia , Feminino , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares/diagnóstico por imagem
7.
J Card Surg ; 37(5): 1250-1253, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35182401

RESUMO

Mitral valve repair (MVR) is undisputedly associated with better clinical and functional outcomes than any other type of valve substitute. Conventional mitral valve surgery in dedicated high-volume centers can assure excellent results in terms of mortality and freedom from mitral regurgitation (MR) recurrence but requires cardiopulmonary bypass (CPB) and cardioplegic heart arrest. Trying to replicate the percentage of success of surgical MVR is the aim of all new transcatheter mitral dedicated devices. In particular, transapical beating-heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography guidance is an expanding field. The safety and feasibility of the procedure have already been largely demonstrated with Neochord and more recently with Harpoon systems. Wang et al. present the outcomes of the first-in-human experience using a novel artificial chordae implantation device, the Mitralstitch system. Despite a quite small cohort of only 10 patients treated, 1-year results are satisfying and comparable with the early experience with former devices (4 patients with moderate or more MR recurrence). The comparison with surgical MVR is still unfavorable and requires further studies and significant procedure improvement. However, the device permits the treatment of anterior and posterior leaflets prolapse and performs quite easily edge-to-edge reparation. It will be interesting to evaluate longer follow-up in larger cohorts of patients as well as the possibility to shift to the transfemoral approach.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cordas Tendinosas/cirurgia , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento
8.
J Card Surg ; 37(12): 4081-4087, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36321669

RESUMO

Mitral valve regurgitation (MR) is a common valvular disorder occurring in up to 10% of the general population. Mitral valve reconstructive strategies may address any of the components, annulus, leaflets, and chords, involved in the valvular competence. The classical repair technique involves the resection of the prolapsing tissue. Chordal replacement was introduced already in the '60, but in the mid '80, some surgeons started to use expanded polytetrafluoroethylene (ePTFE) Gore-Tex sutures. In the last years, artificial chords have been used also using transcatheter approach such as NeoChord DS 1000 (Neochord) and Harpoon TSD-5. The first step is to achieve a good exposure of the papillary muscles that before approaching the implant of the artificial chords. Then, the chords are attached to the papillary muscle, with or without the use of supportive pledgets. The techniques to correctly implant artificial chords are many and might vary considerably from one center to another, but they can be summarized into three big families of suturing techniques: single, running or loop. Regardless of how to anchor to the mitral leaflet, the real challenge that many surgeons have taken on, giving rise to some very creative solutions, has been to establish an adequate length of the chords. It can be established based on anatomically healthy chords, but it is important to bear in mind that surgeons work on the mitral valve when the heart is arrested in diastole, so this length could fail to replicate the required length in the full, beating heart. Hence, some surgeons suggested techniques to overcome this problem. Herein, we aimed to describe the current use of artificial chords in real-world surgery, summarizing all the tips and tricks.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Próteses e Implantes , Politetrafluoretileno , Resultado do Tratamento
9.
J Card Surg ; 37(12): 4047-4052, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36183379

RESUMO

Mitral regurgitation in Barlow disease may still be challenging to be repaired. Most often it involves the posterior leaflet. Many techniques and concepts are currently available; the main goal being to restore a good surface of coaptation. Basic principles such as thorough analysis is still required whatever the approach to assess excess tissue height, width, and prolapse. Nowadays it seems that two different ways of treating mitral prolapse coexist: the nonresection one and the resection one. Both will be discussed and analyzed. Similarly, the use of artificial chordae seems to have a preponderant role to support the free edge and correct a prolapse. Native secondary chord transfer are easy and reliable but seem abandoned by many. Anterior leaflet prolapse is also dealt with and fewer options are available to address this leaflet. Then commissural prolapse is mentioned. It is an important area of the valve which should deserve better treatment than commissuroplasty. Finally, a special entity will be described; mitro annular disjunction. The approach is not or no longer an issue as only good long-term results are important in an era where percutaneous therapy is the only noninvasive technique.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Cordas Tendinosas/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Prolapso da Valva Mitral/cirurgia , Prolapso da Valva Mitral/complicações , Prolapso
10.
J Card Surg ; 37(11): 3722-3728, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36116053

RESUMO

BACKGROUND: Mitral valve repair using expanded polytetrafluoroethylene sutures to replace mitral chordae tendineae is a well-established procedure. However, the incidence of neo-chordae failure causing recurrent mitral regurgitation is not well defined. METHODS: We have reviewed the reported cases of complications after mitral valve repair related to the use of neo-chordae. This study was mainly carried out through PubMed, Medline, and Google Chrome websites. RESULTS: We have identified a total of 26 patients presenting with rupture of polytetrafluoroethylene neo-chordae, mostly being described as isolated cases. Few other cases of recurrent mitral regurgitation with hemolysis were found, where reoperation was not caused by neo-chordal failure but most likely by technical errors. At pathological investigation the findings were substantially similar in all reported cases. The neo-chordae retained their length and pliability, became covered with host tissue and rupture was mainly related to suture size. Mild calcification was observed not interfering with chordal function; chordal infection did never occur. CONCLUSIONS: The use of artificial neo-chordae provides excellent late results with durable mitral valve repair stability. Chordal rupture may occur late postoperatively leading to reoperation because of recurrent mitral regurgitation. Despite its rarity, this potential complication should not be overlooked during follow-up of patients after mitral valve repair using artificial neo-chordae.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Cordas Tendinosas/patologia , Cordas Tendinosas/cirurgia , Humanos , Valva Mitral/patologia , Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Politetrafluoretileno , Suturas
11.
J Card Surg ; 37(5): 1242-1249, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35220611

RESUMO

BACKGROUND: Severe mitral regurgitation (MR) is associated with progressive heart failure and impairment of survival. Degenerative MR accounts for most MV repair surgeries. Conventional mitral valve repair surgery requires cardiopulmonary bypass and is associated with significant morbidity and risks. Transapical beating-heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography (TEE) guidance has the potential to significantly reduce surgical morbidity. We report the first-in-human experience of degenerative MR repair using a novel artificial chordae implantation device (MitralstitchTM system). METHODS: Ten patients with severe MR underwent transapical artificial chordae implantation using MitralstitchTM system. The procedure was performed through a small left thoracotomy under general anesthesia and TEE guidance. Patients underwent transthoracic echocardiography and other assessments during the follow-up. RESULTS: All 10 patients with an average age of 63.7 ± 9.6 years successfully received transapical artificial chordae implantation. Their MR reduced from severe to none or trace in five patients, mild in five patients before discharge. Five patients received one artificial chordal implantation, four patients received two, and one patient received three and edge-to-edge repair by locking two of them. The safety and efficacy endpoint were achieved in all patients at 1-month follow-up. At 1-year follow-up, six patients had mild MR, three patients had moderate MR, one patient had recurrence of severe MR and underwent surgical repair. CONCLUSIONS: The results of this first-in-human study show safety and feasibility of transapical mitral valve repair using MitralStitch system. Patient selection and technical refinement are crucial to improve the outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Idoso , Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Resultado do Tratamento
12.
J Card Surg ; 37(12): 4072-4078, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378871

RESUMO

The chordae tendinae connect the papillary muscles (PMs) to the mitral valve. While the first-order chordae serve to secure the leaflets to maintain valve closure and prevent mitral valve prolapse, the second-order chordae are believed to play a role in maintaining normal left ventricle size and geometry. The PMs, from where the chordae tendinae originate, function as shock absorbers that compensate for the geometric changes of the left ventricular wall. The second-order chordae connect the PMs to both trigons under tension. The tension distributed towards the second-order chordae has been demonstrate to be more than threefold that in their first-order counterpart. Cutting the second-order chordae puts all the tension on the first-order chordae, which are then closer to their rupture point. However, it has been experimentally demonstrated that the tension at which the first-order chordae break is 6.8 newtons (N), by far higher than the maximal tension reached, that is 0.4 N. Even if the clinical reports have been favorable, the importance of cutting the second-order chordae to recover curvature of the anterior leaflet and increase the coaptation length between the mitral valve leaflets has been slowly absorbed by the surgical world. Nevertheless, there are progressive demonstrations that chordal tethering affects the anterior leaflet not only in secondary, but also in primary mitral regurgitation, having a not negligible role in the long-term outcome of mitral repair.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Cordas Tendinosas/cirurgia
13.
J Card Surg ; 37(12): 4517-4523, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36335612

RESUMO

BACKGROUND: Length measurement of artificial chordae remains a critical step during mitral valve repair (MVr). The aim of this study is to assess the effectiveness of a new length measuring technique. METHODS: All consecutive patients with anterior leaflet prolapse/flail who underwent MVr using the described method between January 2020 and January 2022 at our institution were included in the analysis. Clinical and transesophageal echocardiography data were collected postoperatively and at 1-year follow-up. The primary outcome was freedom from mitral regurgitation (MR). Secondary outcomes were presentation with New York Heart Association (NYHA) class <2 and leaflet coaptation length ≥10 mm. RESULTS: Of 25 patients, 16 (64%) were males. A total of 15 (60%) had isolated anterior leaflet disease, while 10 (40%) had concomitant posterior involvement. Twenty patients with isolated MR (80%) underwent right anterior mini-thoracotomy, while 5 (20%) with associated valvular or coronary disease underwent sternotomy. The median number of chordae implanted was 2 [1-4]. Postrepair intraoperative MR grade was 0 in 23 patients (92%) and 1 in 2 (8%). Thirty-day mortality was 0%. De novo atrial fibrillation was 20%. At follow-up, mortality was 0%. No patients presented with moderate or severe MR. A total of 22 patients (88%) were in NYHA class I, while 3 (12%) in class II. The coaptation length was 11 ± 1 mm. CONCLUSIONS: The short-term outcomes of the described technique are good with adequate leaflet coaptation in all treated patients. Long-term results are needed to assess the stability and durability of this repair technique.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Masculino , Humanos , Feminino , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/métodos
14.
J Card Surg ; 37(9): 2862-2863, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35690898

RESUMO

A 60-year-old male presented with sudden onset chest pain and pulmonary edema. The investigation confirmed torrential aortic regurgitation of a bicuspid valve. At surgery, a ruptured fibrous strand was identified which had been supporting the left-right cusp commissure with loss of attachment to the aortic wall. This case demonstrates that fibrous strands may be present as a supporting structure of the aortic valve, and rupture can be a rare cause of torrential aortic regurgitation, similar in pathogenesis to how it may be associated with acute severe mitral regurgitation and chordae tendineae rupture.


Assuntos
Insuficiência da Valva Aórtica , Ruptura Cardíaca , Insuficiência da Valva Mitral , Doença Aguda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/patologia , Cordas Tendinosas/cirurgia , Fibrose , Ruptura Cardíaca/diagnóstico por imagem , Ruptura Cardíaca/etiologia , Ruptura Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Ruptura
15.
Zhonghua Yi Xue Za Zhi ; 102(24): 1839-1845, 2022 Jun 28.
Artigo em Zh | MEDLINE | ID: mdl-35725363

RESUMO

Objective: To discuss the clinical value of preserving subvalvular structure in mitral and aortic valve replacement surgery and its effect on left ventricular contractility. Methods: A total of 97 patients who underwent mitral valve replacement surgery in the Adult Cardiac Surgery of Heart Center of Henan Provincial People's Hospital, Central China Fuwai Hospital from June 2016 to December 2018 were selected as the research subjects, of whom 45 cases were preserved subvalvular structure and 52 cases were in the total resection group (intraoperative total resection of the mitral valve and subvalvular chordae tendineae). General cardiac function indexes and left ventricular function quantitative indexes were compared before and in 3 months and 6 months after the operation of the two groups; The changes of the overall longitudinal strain of the long axis of the apex and the overall circumferential strain of the short axis of the left ventricle determined by the two-dimensional speckle tracking technology were compared before and after the operation. Results: The ages of the patients in the preservation group and the total resection group were (41.8±11.3) and (43.3±10.6) years old, respectively, and the male proportions were 58.0% (26 cases) and 44.0% (23 cases), respectively, with no significant difference (all P>0.05). The aortic occlusion time and cardiopulmonary bypass time of the patients in the preservation group were (57.8±4.5) and (78.6±6.7) min, respectively, which were longer than those in the total resection group [(48.1±4.4) and (48.1±4.4) min, respectively] (all P<0.05). The left atrial pressure of the patients in the preservation group at shutdown was (8.4±1.8) mmHg (1 mmHg=0.133 kPa), which was lower than that of the total resection group (11.3±2.5) mmHg (P<0.001). There were interaction effects between groups and time in regards to the left ventricular end-diastolic diameter ( LVEDD ), left ventricular ejection fraction ( LVEF ) and Tei index, as well as the strain rate of mitral annulus and left ventricular wall of interventricular septum of the preservation group and the total resection group (all P<0.05). LVEDD and LVEF of patients in the preservation group at 3rd month after operation were (44.7±4.0) mm and (45.5±4.2) mm, and at 6th months were (56.5±4.9)% and (58.8±5.0)%, respectively, all larger than (42.7±3.6) mm and (42.7±3.6) mm, (54.5±4.6)% and (56.3±4.8)% of the total resection group. The measured value of LVESD in the preservation group at 3rd month after surgery was (32.6±3.2) mm, which was greater than that in the total resection group (31.2±3.4) mm (P<0.05). The Tei index of patients in the preservation group at 3rd and 6th months after surgery were 1.0±0.2 and 0.8±0.2, respectively, which were lower than those in the total resection group 1.2±0.3 and 0.9±0.2 (all P<0.05). Conclusion: Preserving the subvalvular structure during mitral valve replacement surgery can better improve the patient's left ventricular function and left ventricular systolic capacity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Adulto , Valva Aórtica/cirurgia , Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração , Humanos , Masculino , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Função Ventricular Esquerda
16.
J Card Surg ; 36(3): 971-977, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33428267

RESUMO

BACKGROUND AND AIM: Leaflet resection and chordal reconstruction are established repair techniques for posterior mitral valve (MV) prolapse. This study aimed to compare the clinical results of the resect and respect approaches, with a particular focus on MV hemodynamics. METHODS: Overall, 291 patients who underwent elective MV repair for isolated posterior leaflet prolapse between 2012 and 2020 were enrolled. Patients who underwent leaflet resection alone were classified as the "resection" group (n = 166), while patients who underwent neochordal replacement with/without limited leaflet resection were classified as the "respect" group (n = 125). Early postoperative MV hemodynamics and midterm repair durability were compared between the groups. RESULTS: The annuloplasty ring size was significantly larger in the respect group than in the resection group (31.0 ± 2.1 vs. 30.4 ± 2.0 mm, p = .028). The respect group showed significantly lower mean MV gradient (2.6 ± 1.1 vs. 3.0 ± 1.4 mmHg, p = .03) and larger effective orifice area (EOA) (1.86 ± 0.48 vs. 1.66 ± 0.47 cm2 , p < .001) than the resection group. Multivariable analysis identified the respect approach, younger age, female sex, larger ring size, and partial band as independent determinants of larger EOA. The rate of freedom from moderate or greater recurrent mitral regurgitation 5 years postoperatively was 90.9% in both groups. CONCLUSIONS: The respect approach allowed for a lower MV gradient and a larger EOA than the resection approach, which is possibly due to the capability of implanting a larger annuloplasty ring.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Cordas Tendinosas/cirurgia , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Prolapso , Respeito , Resultado do Tratamento
17.
J Card Surg ; 36(10): 3959-3962, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34338375

RESUMO

Parachute deformity of atrioventricular valve occurs when chordae tendineae arise either from one papillary muscle or a closely placed muscle group. Preoperative detection is easier with mitral involvement than with tricuspid valve. We present two cases of parachute tricuspid valve (PTV) which were successfully repaired.


Assuntos
Cordas Tendinosas , Valva Tricúspide , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Humanos , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
18.
J Card Surg ; 36(7): 2541-2542, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33855770

RESUMO

Iatrogenic chordal rupture with severe mitral regurgitation is a rare but serious complication associated with the use of Impella device. We present a case of a 47-year-old man with ischemic cardiomyopathy who required insertion of an Impella 5.0 device. During Impella support, he developed acute pulmonary edema secondary to newly diagnosed posterior mitral valve chordal rupture and subsequent severe mitral regurgitation. He underwent implantation of a durable left ventricular assist device with concomitant edge-to-edge mitral valve repair through the apex.


Assuntos
Ruptura Cardíaca , Insuficiência da Valva Mitral , Cordas Tendinosas/cirurgia , Ruptura Cardíaca/etiologia , Ruptura Cardíaca/cirurgia , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia
19.
Kyobu Geka ; 74(8): 606-609, 2021 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-34334603

RESUMO

A 51-year-old man was diagnosed as having mitral valve regurgitation( MR). Transesophageal echocardiography revealed severe MR due to A2 prolapse. We decided to perform a mitral valve plasty (MVP). The length of an artificial chord was estimated by measuring the distance from the anterior and posterior papillary muscles to A2 on cardiac computed tomography (CT). The operation was performed with a median sternotomy. The leaflet prolapse lesion was localized in A2, and one torn chord was revealed. Polytetrafluoroethylene sutures were fixed to the papillary muscle, and markings were performed. After fixing the artificial chord to A2 in the predicted length before the operation, a leakage test was performed. We confirmed that the MR had disappeared. The postoperative course was good, and no MR was detected upon postoperative echocardiography. Preoperative prediction of the artificial chord length using cardiac CT is useful because it can be adjusted relatively easily.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Politetrafluoretileno , Tomografia , Resultado do Tratamento
20.
J Card Surg ; 35(9): 2432-2435, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32725653

RESUMO

Severe recurrent mitral regurgitation within 1 year of mitral valve repair is usually attributed to a technical issue with the original repair procedure. However, when artificial chordae are employed to correct mitral valve prolapse, ventricular remodeling (ie, decreased ventricular size) can lead to recurrent prolapse and valve dysfunction. To illustrate this phenomenon, we present two patients who experienced early failure after undergoing mitral valve repair with artificial chordae.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA