Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.740
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Curr Opin Gastroenterol ; 40(3): 217-224, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353269

RESUMO

PURPOSE OF REVIEW: Isolated terminal ileitis is an increasing phenomenon identified during colonoscopy. Idiopathic terminal ileitis (IDTI) is a diagnosis of exclusion, representing a significant challenge from a diagnostic and management point of view. This review provides an overview of the most recent and relevant evidence on idiopathic IDTI, focusing on its evolution, the natural history and the management strategies proposed in the literature. RECENT FINDINGS: IDTI is uncommon, with a reported prevalence between 0.5 and 7%. The main differential is with Crohn's disease and intestinal tuberculosis in endemic countries. A proportion of patients (0-50%) can progress and develop Crohn's disease; however, there are no reliable predictive factors to stratify IDTI patients. SUMMARY: IDTI is a challenging entity, with a small proportion of patients progressing to Crohn's disease over time thus requiring follow-up. Noninvasive modalities such as capsule endoscopy are useful for follow-up, but further research is required to better understand this entity.


Assuntos
Endoscopia por Cápsula , Doença de Crohn , Ileíte , Humanos , Doença de Crohn/diagnóstico , Ileíte/diagnóstico , Colonoscopia , Prevalência
2.
Curr Opin Gastroenterol ; 40(3): 175-182, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38190421

RESUMO

PURPOSE OF REVIEW: Adult small bowel intussusception (SBI) differs in incidence, symptomatology and management from the more commonly encountered paediatric intussusception. This review spans across the multitude of causes of adult SBI, and summarises the diagnostic work-up and management options according to recent literature. RECENT FINDINGS: There has been an increase in use of small bowel capsule endoscopy and point-of-care ultrasound for the diagnosis of acute adult SBI. SUMMARY: A high degree of suspicion of a malignant cause of SBI is required in the adult population. Alarm clinical features include weight loss, history of malignancy, and iron deficiency anaemia. CT remains the gold standard imaging technique as it may identify the lead point and thus aid in endoscopic or surgical management. If malignancy is excluded and no lead point is identified, serology and histology may be helpful to look for inflammatory, infective and autoimmune aetiology.


Assuntos
Endoscopia por Cápsula , Intussuscepção , Neoplasias , Adulto , Criança , Humanos , Intussuscepção/diagnóstico por imagem , Intussuscepção/etiologia , Intestino Delgado/patologia , Ultrassonografia
3.
Curr Opin Gastroenterol ; 40(5): 338-341, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38662476

RESUMO

PURPOSE OF REVIEW: We aim to review the types of device-assisted deep enteroscopy endoscopes, tips for a successful procedure as well as areas for improvement. RECENT FINDINGS: Deep enteroscopy allows for diagnostic and therapeutic intervention of the small bowel and can be used as an adjunct to video capsule endoscopy to improve the yield and management of small bowel lesions. SUMMARY: Our top tips for deep enteroscopy success include reviewing patient history and prior imaging, utilizing CO 2 insufflation or water exchange, verifying quality measures and emphasizing ergonomics. With these, endoscopists can optimize patient outcomes while minimizing occupational risks. New aspects of deep enteroscopy equipment focus on high-resolution imaging, a larger working channel, and enhanced scope angulation. Proposed improvements include developing innovative technology to optimize the color and clarity of the high-resolution imaging, minimizing the number of staff required for the procedure, and decreasing ergonomic strain.


Assuntos
Intestino Delgado , Humanos , Intestino Delgado/diagnóstico por imagem , Enteropatias/diagnóstico por imagem , Enteropatias/diagnóstico , Endoscopia Gastrointestinal/métodos , Desenho de Equipamento , Endoscopia por Cápsula/métodos , Endoscópios Gastrointestinais , Ergonomia/métodos
4.
Ann Hematol ; 103(1): 1-4, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37940717

RESUMO

The diagnostic work-up in iron deficiency anaemia (IDA) patients can be challenging when bleedings or malabsorption are not clinically manifest. Lesions on the small bowel mucosa may cause IDA. We evaluated the prevalence of lesions on the small bowel mucosa detected at Videocapsule Endoscopy (VCE) in IDA patients following negative upper and lower endoscopies. Clinical and endoscopic data collected in 5 centres were retrieved. Lesions with a high bleeding potential (P2) were computed, and predictive factors investigated at multivariate analysis. By considering data of 230 patients, the endoscopic examination detected a total of 96 (41.7%; 95% CI: 35.4-48.1) P2 lesions on the small bowel mucosa, including 4 (1.7%) cancers. The use of non-steroidal anti-inflammatory drugs was found to be the only associated factor at both univariate (OR: 5.7, 95% CI: 2.4-13.4; P <0.001) and multivariate (OR: 2.8; 95% CI: 1.7-3.9, P <0.01) analyses. Present study showed that evaluation of small bowel mucosa with VCE allows to disclose a potential cause of IDA in near half patients. The cooperation between haematologists and gastroenterologists in the diagnostic work-up may be useful.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/epidemiologia , Anemia Ferropriva/etiologia , Hemorragia Gastrointestinal/etiologia , Endoscopia por Cápsula/efeitos adversos , Intestino Delgado/patologia
5.
Gastrointest Endosc ; 99(2): 227-236, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37838323

RESUMO

BACKGROUND AND AIMS: Small-bowel neuroendocrine tumors (NETs) are slow growing, clinically silent tumors whose prognosis depends on disease stage. Members of kindreds with a familial form of small intestinal NETs (SI-NETs) represent a high-risk population for whom early detection improves disease outcome. Our aim was to determine the utility of small-bowel capsule endoscopy (SB-CE) for screening high-risk asymptomatic relatives from kindreds with familial carcinoid. METHODS: One hundred seventy-four asymptomatic subjects with a family history (≥2 family members) of SI-NETs were screened under Protocol NCT00646022, Natural History of Familial Carcinoid Tumor at the National Institutes of Health. All patients were imaged with SB-CE and 18fluoro-dihydroxphenylalanine (18F-DOPA) positron emission tomography (PET)/CT, and results were independently analyzed. Patients with a positive imaging study underwent surgical exploration. RESULTS: Thirty-five of 174 asymptomatic subjects screened for SI-NETs were positive on either SB-CE or 18F-DOPA PET. Thirty-two of 35 patients with a positive study were confirmed at surgery. SB-CE was positive in 28 of 32 patients with confirmed tumors for a per-patient sensitivity of 87.5%. SB-CE had a specificity of 97.3% and a negative predictive value of 96.5%. The average tumor number and size were 7.7 and 5.0 mm, respectively, and 81.2% of patients had multiple tumors. 18F-DOPA PET/CT had a similar sensitivity of 84% versus surgery. CONCLUSIONS: SB-CE is a sensitive and specific method comparable with 18F-DOPA PET/CT for screening high-risk patients with familial SI-NET. (Clinical trial registration number: NCT00646022.).


Assuntos
Endoscopia por Cápsula , Tumor Carcinoide , Di-Hidroxifenilalanina/análogos & derivados , Tumores Neuroendócrinos , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos , Tumor Carcinoide/diagnóstico por imagem
6.
Gastrointest Endosc ; 99(2): 245-253.e2, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37797727

RESUMO

BACKGROUND AND AIMS: We prospectively determined the efficacy of flexible spectral imaging color enhancement (FICE) used with second-generation colon capsule endoscopy (CCE) for colorectal polyps and tumors (CRTs). METHODS: This study included optical colonoscopy within 4 months after CCE. Two colonoscopists independently reviewed CCE using white-light images (CCE-WL) and CCE using FICE images (CCE-FICE), respectively. Based on colonoscopic findings as the criterion standard, the diagnostic accuracy for CRTs was compared between CCE-WL and CCE-FICE. RESULTS: Of 89 enrolled patients (65 men and 24 women; 75 with CRTs including 36 with serrated lesions, 63 with adenomas, and 9 with adenocarcinomas), the per-patient detectability of CCE-FICE for the representative CRTs was significantly higher than that of CCE-WL: overall CRTs (CCE-WL, 79%; CCE-FICE, 88%; P = .0001), 6- to 9-mm CRTs (CCE-WL, 63%; CCE-FICE, 94%; P = .0055), and ≥6-mm CRTs (CCE-WL, 78%; CCE-FICE, 93%; P = .0159). The per-lesion sensitivity of CCE-FICE was significantly higher than that of CCE-WL for CRTs: overall (CCE-WL, 61%; CCE-FICE, 79%; P < .0001), <6 mm (CCE-WL, 53%; CCE-FICE, 69%; P < .0001), 6- to 9-mm CRTs (CCE-WL, 65%; CCE-FICE, 93%; P = .0007), slightly elevated CRTs (CCE-WL, 53%; CCE-FICE, 75%; P < .0001), tubular adenomas (CCE-WL, 61%; CCE-FICE, 79%; P < .0001), and serrated polyps (CCE-WL, 57%; CCE-FICE, 74%; P = .0022). Both modes detected all adenocarcinomas. No significant differences were found between CCE-WL and CCE-FICE of the per-lesion sensitivity for ≥10-mm CRTs (CCE-WL, 81%; CCE-FICE, 94%; P = .1138) or protruding CRTs (CCE-WL, 77%; CCE-FICE, 86%; P = .0614). Kappa coefficients for overall CRTs for CCE-WL and CCE-FICE were .66 and .64, respectively, which indicated substantial agreement. CONCLUSIONS: CCE-FICE improved the detection rates for all CRTs except adenocarcinomas, ≥10-mm polyps, and protruding polyps when compared with CCE-WL. (Clinical trial registration number: UMIN 000021125.).


Assuntos
Adenocarcinoma , Adenoma , Endoscopia por Cápsula , Pólipos do Colo , Neoplasias Colorretais , Masculino , Humanos , Feminino , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Estudos Prospectivos , Endoscopia por Cápsula/métodos , Sensibilidade e Especificidade , Colonoscopia/métodos , Adenoma/diagnóstico por imagem , Adenoma/patologia , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Colo/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Aumento da Imagem/métodos
7.
Endoscopy ; 56(8): 572-580, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38365215

RESUMO

BACKGROUND: Pan-intestinal capsule endoscopy (PCE) evaluates the small bowel and colon noninvasively. This study evaluated diagnostic accuracy and safety of PCE vs. colonoscopy as first-line examination in suspected mid-lower gastrointestinal bleeding (MLGIB). METHODS: In this prospective, single-center, single-blinded cohort study, consecutive patients with suspected MLGIB underwent PCE followed by same-day colonoscopy. Diagnostic accuracy for potentially hemorrhagic lesions (PHLs; combined diagnosis by PCE + colonoscopy) and incidence of adverse events were assessed. RESULTS: 100 patients were included (median age 70 [range 18-92] years; 65% female). PHLs were diagnosed in 46 patients, including small-bowel and/or colon angioectasias in 32. PCE correctly identified 54 individuals without PHLs, and 95.7% (44/46) of those with PHLs vs. 50.0% (23/46) for colonoscopy (P<0.01). PHLs were detected by PCE alone in 65.2% (30/46), both examinations in 28.3% (13/46), and colonoscopy alone in 6.5% (3/46). PHLs were diagnosed at the ileocolonic region in 28% of patients, with PCE diagnosing 25/28 cases (89.3%) and colonoscopy diagnosing 23/28 (82.1%; P=0.13). Interventional procedures were performed at colonoscopy in 13/81 patients with iron-deficiency anemia (16.0%) vs. 6/19 patients with overt bleeding (31.6%; P<0.01). No significant adverse events occurred with PCE vs. 2% with colonoscopy. CONCLUSIONS: In patients with MLGIB, PCE avoided further invasive procedures in >50% of patients. PCE was safe and more effective than colonoscopy in identifying PHL both in the small bowel and colon. These results support the potential use of PCE as first-line examination in patients with suspected MLGIB.


Assuntos
Endoscopia por Cápsula , Colonoscopia , Hemorragia Gastrointestinal , Humanos , Endoscopia por Cápsula/métodos , Feminino , Masculino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Idoso , Pessoa de Meia-Idade , Colonoscopia/métodos , Colonoscopia/efeitos adversos , Adulto , Estudos Prospectivos , Idoso de 80 Anos ou mais , Adolescente , Método Simples-Cego , Adulto Jovem , Intestino Delgado/diagnóstico por imagem
8.
Scand J Gastroenterol ; 59(8): 989-995, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38742832

RESUMO

BACKGROUND AND AIM: To explore the feasibility of a standardized training and assessment system for magnetically controlled capsule gastroscopy (MCCG). METHODS: The results of 90 trainees who underwent the standardized training and assessment system of the MCCG at the First Affiliated Hospital of Xi'an Jiaotong University from May 2020 to November 2023 was retrospectively analyzed. The trainees were divided into three groups according to their medical backgrounds: doctor, nurse, and non-medical groups. The training and assessment system adopted the '7 + 2' mode, seven days of training plus two days of theoretical and operational assessment. The passing rates of theoretical, operational, and total assessment were the primary outcomes. Satisfaction and mastery of the MCCG was checked. RESULTS: Ninety trainees were assessed; theoretical assessment's passing rates in the three groups were 100%. The operational and total assessment passing rates were 100% (25/25), 97.92% (47/48), and 94.12% (16/17), for the doctor, nurse, and non-doctor groups respectively, with no significant difference (χ2 = 1.741, p = 0.419). No bleeding or perforation occurred during the procedure. Approximately, 96.00% (24/25), 95.83% (46/48), and 94.12% (16/17) of the doctor, nurse and non-medical groups anonymously expressed great satisfaction, respectively, without statistically significant difference (χ2 = 0.565, p = 1.000). The average follow-up time was 4-36 months, and 87 trainees (96.67%) had mastered the operation of the MCCG in daily work. CONCLUSIONS: Standardized training and assessment of magnetically controlled capsule endoscopists is effective and feasible. Additionally, a strict assessment system and long-term communication and learning can improve teaching effects.


Assuntos
Endoscopia por Cápsula , Competência Clínica , Gastroscopia , Humanos , Gastroscopia/educação , Gastroscopia/métodos , Estudos Retrospectivos , Feminino , Masculino , Endoscopia por Cápsula/métodos , Endoscopia por Cápsula/educação , Adulto , Estudos de Viabilidade , Avaliação Educacional/métodos , Magnetismo , China
9.
BMC Gastroenterol ; 24(1): 80, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388860

RESUMO

OBJECTIVES: Poorly visualized images that appear during small bowel capsule endoscopy (SBCE) can confuse the interpretation of small bowel lesions and increase the physician's workload. Using a validated artificial intelligence (AI) algorithm that can evaluate the mucosal visualization, we aimed to assess whether SBCE reading after the removal of poorly visualized images could affect the diagnosis of SBCE. METHODS: A study was conducted to analyze 90 SBCE cases in which a small bowel examination was completed. Two experienced endoscopists alternately performed two types of readings. They used the AI algorithm to remove poorly visualized images for the frame reduction reading (AI user group) and conducted whole frame reading without AI (AI non-user group) for the same patient. A poorly visualized image was defined as an image with < 50% mucosal visualization. The study outcomes were diagnostic concordance and reading time between the two groups. The SBCE diagnosis was classified as Crohn's disease, bleeding, polyp, angiodysplasia, and nonspecific finding. RESULTS: The final SBCE diagnoses between the two groups showed statistically significant diagnostic concordance (k = 0.954, p < 0.001). The mean number of lesion images was 3008.5 ± 9964.9 in the AI non-user group and 1401.7 ± 4811.3 in the AI user group. There were no cases in which lesions were completely removed. Compared with the AI non-user group (120.9 min), the reading time was reduced by 35.6% in the AI user group (77.9 min). CONCLUSIONS: SBCE reading after reducing poorly visualized frames using the AI algorithm did not have a negative effect on the final diagnosis. SBCE reading method integrated with frame reduction and mucosal visualization evaluation will help improve AI-assisted SBCE interpretation.


Assuntos
Endoscopia por Cápsula , Doenças do Colo , Doença de Crohn , Humanos , Inteligência Artificial , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Estudos Retrospectivos
10.
J Gastroenterol Hepatol ; 39(2): 337-345, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37842961

RESUMO

BACKGROUND AND AIM: The PillCam patency capsule (PC) without a radio frequency identification tag was released to preclude retention of the small bowel capsule endoscope (CE) in Japan in 2012. We conducted a multicenter study to determine tag-less PC-related adverse events (AEs). METHODS: We first conducted a retrospective survey using a standardized data collection sheet for the clinical characteristics of PC-related AEs among 1096 patients collected in a prospective survey conducted between January 2013 and May 2014 (Cohort 1). Next, we retrospectively investigated additional AEs that occurred before and after Cohort 1 within the period June 2012 and December 2014 among 1482 patients (Cohort 2). RESULTS: Of the 2578 patients who underwent PC examinations from both cohorts, 74 AEs occurred among 61 patients (2.37%). The main AEs were residual parylene coating in 25 events (0.97%), PC-induced small bowel obstruction, suspicious of impaction, in 23 events (0.89%), and CE retention even after patency confirmation in 10 events (0.39%). Residual parylene coating was significantly associated with Crohn's disease (P < 0.01). Small bowel obstruction was significantly associated with physicians with less than 1 year of experience handling the PC and previous history of postprandial abdominal pain (P < 0.01 and P < 0.03, respectively). CE retention was ascribed to erroneous judgment of PC localization in all cases. CONCLUSIONS: This large-scale multicenter study provides evidence supporting the safety and efficiency of a PC to preclude CE retention. Accurate PC localization in patients without excretion and confirmation of previous history of postprandial abdominal pain before PC examinations is warranted (UMIN000010513).


Assuntos
Endoscopia por Cápsula , Obstrução Intestinal , Polímeros , Xilenos , Humanos , Estudos Retrospectivos , Endoscopia por Cápsula/efeitos adversos , Estudos Prospectivos , Obstrução Intestinal/epidemiologia , Obstrução Intestinal/etiologia , Dor Abdominal/etiologia
11.
J Gastroenterol Hepatol ; 39(1): 165-171, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37837361

RESUMO

BACKGROUND AND AIM: Although small-bowel capsule endoscopy (CE) is widely used for obscure gastrointestinal bleeding (OGIB), long-term outcomes for OGIB patients after negative CE remain unclear. Herein, we defined negative CE as P0 (no bleeding potential) or P1 (less likely to bleed), based on the P classification using CE. We aimed to clarify long-term outcomes of patients with OGIB after negative CE. METHODS: This single-center observational study enrolled 461 consecutive patients with OGIB who underwent CE from March 2014 to October 2021 and were followed up for >1 year. We examined rebleeding rates and predictive factors. RESULTS: Two hundred and twenty-four (49%) patients had P0, and 237 (51%) had P1 findings. Rebleeding occurred in 9% and 16% of patients in the P0 and P1 groups, respectively. Two patients in the P0 group and 15 in the P1 group showed rebleeding from the small bowel. The rate of small-bowel rebleeding was significantly lower in the P0 group than that in the P1 group (1% vs 6%, P = 0.002), as was the cumulative rebleeding rate (P = 0.004). In the multivariate analysis, history of endoscopic hemostasis (hazard ratio [HR] = 15.958, 95% confidence interval [CI]:4.950-51.447, P < 0.001) and P1 CE findings (HR = 9.989, 95% CI: 2.077-48.030, P = 0.004) were independently predicted small-bowel rebleeding. CONCLUSIONS: OGIB with P0 CE findings rarely showed rebleeding from the small bowel. Rebleeding may occur in patients with OGIB. Patients with history of endoscopic hemostasis for small-bowel lesions or P1 CE findings should be followed up intensively.


Assuntos
Endoscopia por Cápsula , Hemostase Endoscópica , Humanos , Endoscopia por Cápsula/efeitos adversos , Recidiva , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Fatores de Tempo , Estudos Retrospectivos , Endoscopia Gastrointestinal
12.
J Gastroenterol Hepatol ; 39(1): 157-164, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37830487

RESUMO

BACKGROUND AND AIM: Convolutional neural network (CNN) systems that automatically detect abnormalities from small-bowel capsule endoscopy (SBCE) images are still experimental, and no studies have directly compared the clinical usefulness of different systems. We compared endoscopist readings using an existing and a novel CNN system in a real-world SBCE setting. METHODS: Thirty-six complete SBCE videos, including 43 abnormal lesions (18 mucosal breaks, 8 angioectasia, and 17 protruding lesions), were retrospectively prepared. Three reading processes were compared: (A) endoscopist readings without CNN screening, (B) endoscopist readings after an existing CNN screening, and (C) endoscopist readings after a novel CNN screening. RESULTS: The mean number of small-bowel images was 14 747 per patient. Among these images, existing and novel CNN systems automatically captured 24.3% and 9.4% of the images, respectively. In this process, both systems extracted all 43 abnormal lesions. Next, we focused on the clinical usefulness. The detection rates of abnormalities by trainee endoscopists were not significantly different across the three processes: A, 77%; B, 67%; and C, 79%. The mean reading time of the trainees was the shortest during process C (10.1 min per patient), followed by processes B (23.1 min per patient) and A (33.6 min per patient). The mean psychological stress score while reading videos (scale, 1-5) was the lowest in process C (1.8) but was not significantly different between processes B (2.8) and A (3.2). CONCLUSIONS: Our novel CNN system significantly reduced endoscopist reading time and psychological stress while maintaining the detectability of abnormalities. CNN performance directly affects clinical utility and should be carefully assessed.


Assuntos
Endoscopia por Cápsula , Aprendizado Profundo , Humanos , Endoscopia por Cápsula/métodos , Estudos Retrospectivos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Redes Neurais de Computação
13.
Curr Gastroenterol Rep ; 26(6): 157-165, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38630422

RESUMO

PURPOSE OF REVIEW: Over the last few decades, there have been remarkable strides in endoscopy and radiological imaging that have advanced gastroenterology. However, the management of neurogastroenterological disorders has lagged behind, in part handicapped by the use of catheter-based manometry that is both non-physiological and uncomfortable. The advent of capsule technology has been a game changer for both diagnostic and therapeutic applications. RECENT FINDINGS: Here, we discuss several capsule devices that are available or under investigation. There are three technologies that are FDA approved. Wireless motility capsule measures pH and pressure and provides clinically impactful information regarding gastric, small intestine and colonic transit, without radiation that has been demonstrated to guide management of gastroparesis, dyspepsia and constipation. Wireless ambulatory pH monitoring capsule is currently the gold standard for assessing gastroesophageal acid reflux. In the therapeutics arena, an orally ingested vibrating capsule has been recently FDA approved for the treatment of chronic constipation, supported by a robust phase 3 clinical trial which showed significant improvement in constipation symptoms and quality of life. There are several capsules currently under investigation. Smart capsule bacterial detection system and Capscan® are capsules that can sample fluid in the small or large bowel and provide microbiome analysis for detection of small intestinal bacterial (SIBO) or fungal overgrowth (SIFO). Another investigational gas sensing capsule analyzing hydrogen, CO2, volatile fatty acids and capsule orientation, can measure regional gut transit time and luminal gas concentrations and assess gastroparesis, constipation or SIBO. Therapeutically, other vibrating capsules are in development. Innovations in capsule technology are poised to transform our ability to investigate gut function physiologically, and non-invasively deliver targeted treatment(s), thereby providing both accurate diagnostic information and luminally-directed, safe therapy.


Assuntos
Endoscopia por Cápsula , Gastroenteropatias , Motilidade Gastrointestinal , Humanos , Gastroenteropatias/diagnóstico , Gastroenteropatias/terapia , Gastroenteropatias/fisiopatologia , Endoscopia por Cápsula/métodos , Motilidade Gastrointestinal/fisiologia , Constipação Intestinal/terapia , Constipação Intestinal/diagnóstico , Constipação Intestinal/fisiopatologia
14.
Dig Dis Sci ; 69(6): 2140-2146, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38637455

RESUMO

BACKGROUND AND AIMS: Small bowel gastrointestinal bleeding (GIB) is associated with multiple blood transfusions, prolonged and/or multiple hospital admissions, utilization of significant healthcare resources, and negative effects on patient quality of life. There is a well-recognized association between antithrombotic medications and small bowel GIB. We aimed to identify the diagnostic yield of small bowel capsule endoscopy (SBCE) in patients on antithrombotic medications and the impact of SBCE on treatment course. METHODS: The electronic medical records of nineteen hundred eighty-six patients undergoing SBCE were retrospectively reviewed. RESULTS: The diagnostic yield for detecting stigmata of recent bleeding and/or actively bleeding lesions in SBCE was higher in patients that were on antiplatelet agents (21.6%), patients on anticoagulation (22.5%), and in patients that had their SBCE performed while they were inpatient (21.8%), when compared to the patients not on antiplatelet agents (12.1%), patients not on anticoagulation (13.5%), and with patients that had their SBCE performed in the outpatient setting (12%). Of 318 patients who had stigmata of recent bleeding and/or actively bleeding lesion(s) identified on SBCE, SBCE findings prompted endoscopic evaluation (small bowel enteroscopy, esophagogastroduodenoscopy (EGD), and/or colonoscopy) in 25.2%, with endoscopic hemostasis attempted in 52.5%. CONCLUSIONS: Our study, the largest conducted to date, emphasizes the importance of performing SBCE as part of the evaluation for suspected small bowel bleeding, particularly in patients taking antithrombotic therapy, and especially during their inpatient hospital stay.


Assuntos
Endoscopia por Cápsula , Fibrinolíticos , Hemorragia Gastrointestinal , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Intestino Delgado/patologia , Intestino Delgado/diagnóstico por imagem , Fibrinolíticos/efeitos adversos , Fibrinolíticos/uso terapêutico , Inibidores da Agregação Plaquetária/efeitos adversos , Anticoagulantes/efeitos adversos , Idoso de 80 Anos ou mais
15.
Dig Endosc ; 36(4): 437-445, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37612137

RESUMO

OBJECTIVES: Although several studies have shown the usefulness of artificial intelligence to identify abnormalities in small-bowel capsule endoscopy (SBCE) images, few studies have proven its actual clinical usefulness. Thus, the aim of this study was to examine whether meaningful findings could be obtained when negative SBCE videos were reanalyzed with a deep convolutional neural network (CNN) model. METHODS: Clinical data of patients who received SBCE for suspected small-bowel bleeding at two academic hospitals between February 2018 and July 2020 were retrospectively collected. All SBCE videos read as negative were reanalyzed with the CNN algorithm developed in our previous study. Meaningful findings such as angioectasias and ulcers were finally decided after reviewing CNN-selected images by two gastroenterologists. RESULTS: Among 202 SBCE videos, 103 (51.0%) were read as negative by humans. Meaningful findings were detected in 63 (61.2%) of these 103 videos after reanalyzing them with the CNN model. There were 79 red spots or angioectasias in 40 videos and 66 erosions or ulcers in 35 videos. After reanalysis, the diagnosis was changed for 10 (10.3%) patients who had initially negative SBCE results. During a mean follow-up of 16.5 months, rebleeding occurred in 19 (18.4%) patients. The rebleeding rate was 23.6% (13/55) for patients with meaningful findings and 16.1% (5/31) for patients without meaningful findings (P = 0.411). CONCLUSION: Our CNN algorithm detected meaningful findings in negative SBCE videos that were missed by humans. The use of deep CNN for SBCE image reading is expected to compensate for human error.


Assuntos
Endoscopia por Cápsula , Aprendizado Profundo , Humanos , Endoscopia por Cápsula/métodos , Inteligência Artificial , Estudos Retrospectivos , Úlcera
16.
Sensors (Basel) ; 24(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38931744

RESUMO

This research proposes a miniature circular polarization antenna used in a wireless capsule endoscopy system at 2.45 GHz for industrial, scientific, and medical bands. We propose a method of cutting a chamfer rectangular slot on a circular radiation patch and introducing a curved radiation structure into the centerline position of the chamfer rectangular slot, while a short-circuit probe is added to achieve miniaturization. Therefore, we significantly reduced the size of the antenna and made it exhibit circularly polarized radiation characteristics. A cross-slot is cut in the GND to enable the antenna to better cover the operating band while being able to meet the complex human environment. The effective axis ratio bandwidth is 120 MHz (2.38-2.50 GHz). Its size is π × 0.032λ02 × 0.007λ0 (where λ0 is the free-space wavelength of at 2.4 GHz). In addition, the effect of different organs such as muscle, stomach, small intestine, and big intestine on the antenna when it was embedded into the wireless capsule endoscopy (WCE) system was further discussed, and the results proved that the WCE system has better robustness in different organs. The antenna's specific absorption rate can follow the IEEE Standard Safety Guidelines (IEEE C95.1-1999). A prototype is fabricated and measured. The experimental results are consistent with the simulation results.


Assuntos
Endoscopia por Cápsula , Desenho de Equipamento , Tecnologia sem Fio , Endoscopia por Cápsula/instrumentação , Endoscopia por Cápsula/métodos , Humanos , Tecnologia sem Fio/instrumentação , Cápsulas Endoscópicas
17.
Zhongguo Dang Dai Er Ke Za Zhi ; 26(6): 584-591, 2024 Jun 15.
Artigo em Zh | MEDLINE | ID: mdl-38926374

RESUMO

OBJECTIVES: To explore the value of different endoscopic scoring methods in assessing disease activity in pediatric Crohn's disease (CD). METHODS: A total of 70 children diagnosed with CD at the Children's Hospital of Chongqing Medical University from January 2018 to January 2023 were included. Clinical disease activity was assessed using the Pediatric Crohn's Disease Activity Index (PCDAI), while different endoscopic scores were assigned based on endoscopic findings. Spearman rank correlation analysis was used to evaluate the correlation between each endoscopic scoring method and PCDAI as well as laboratory indicators. Kappa test was used to assess the consistency between colonoscopy/capsule endoscopy scoring methods and PCDAI in determining CD activity. Receiver operating characteristic curve analysis was performed to assess the diagnostic efficacy of laboratory indicators in predicting endoscopic activity. RESULTS: The PCDAI score showed a moderate positive correlation with the scores of Crohn's Disease Endoscopic Index of Severity (CDEIS) (rs=0.696, P<0.01), Simple Endoscopic Score for Crohn's Disease (SES-CD) (rs=0.680, P<0.01), Lewis Score (rs=0.540, P<0.01), and Capsule Endoscopy-Crohn's Disease Index (CE-CD) (rs=0.502, P<0.01). The consistency between all endoscopic scoring methods and PCDAI in determining CD activity was poor (Kappa=0.069-0.226). Erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), hematocrit (HCT), and serum albumin (ALB) levels showed a moderate correlation with the PCDAI score and the scores of colonoscopy scoring methods (CDEIS and SES-CD) (|rs|=0.581-0.725, P<0.01), but a weak correlation with the scores of capsule scoring methods (P<0.05). ESR and CRP had higher area under the curve (AUC) values in predicting disease activity based on PCDAI, CDEIS, SES-CD, and Lewis Score compared to HCT and ALB (P<0.05). CONCLUSIONS: CDEIS, SES-CD, Lewis Score, and CE-CD can be used to evaluate disease activity in pediatric CD, but they do not fully correspond with disease activity assessed by PCDAI. Elevated levels of ESR and CRP can predict clinical and endoscopic disease activity in children with CD.


Assuntos
Colonoscopia , Doença de Crohn , Índice de Gravidade de Doença , Humanos , Doença de Crohn/diagnóstico , Doença de Crohn/patologia , Doença de Crohn/sangue , Criança , Masculino , Feminino , Adolescente , Pré-Escolar , Endoscopia por Cápsula , Proteína C-Reativa/análise , Sedimentação Sanguínea , Curva ROC
18.
Gut ; 73(1): 186-202, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37734912

RESUMO

Smart capsules are developing at a tremendous pace with a promise to become effective clinical tools for the diagnosis and monitoring of gut health. This field emerged in the early 2000s with a successful translation of an endoscopic capsule from laboratory prototype to a commercially viable clinical device. Recently, this field has accelerated and expanded into various domains beyond imaging, including the measurement of gut physiological parameters such as temperature, pH, pressure and gas sensing, and the development of sampling devices for better insight into gut health. In this review, the status of smart capsules for sensing gut parameters is presented to provide a broad picture of these state-of-the-art devices while focusing on the technical and clinical challenges the devices need to overcome to realise their value in clinical settings. Smart capsules are developed to perform sensing operations throughout the length of the gut to better understand the body's response under various conditions. Furthermore, the prospects of such sensing devices are discussed that might help readers, especially health practitioners, to adapt to this inevitable transformation in healthcare. As a compliment to gut sensing smart capsules, significant amount of effort has been put into the development of robotic capsules to collect tissue biopsy and gut microbiota samples to perform in-depth analysis after capsule retrieval which will be a game changer for gut health diagnosis, and this advancement is also covered in this review. The expansion of smart capsules to robotic capsules for gut microbiota collection has opened new avenues for research with a great promise to revolutionise human health diagnosis, monitoring and intervention.


Assuntos
Biópsia , Trato Gastrointestinal , Robótica , Humanos , Endoscopia por Cápsula , Microbioma Gastrointestinal
19.
Am J Gastroenterol ; 118(6): 1019-1027, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36563317

RESUMO

INTRODUCTION: Patency capsule (PC) is a recommended procedure to rule out small bowel stenosis before video capsule endoscopy (VCE). We examined future clinical outcomes among patients with a failed PC vs patients in whom the PC had passed (passed PC). METHODS: A post hoc analysis of 2 prospective cohort studies of adult patients with quiescent small bowel Crohn's disease (CD) who underwent PC between 2013 and 2020. The primary composite outcome was the need for intestinal surgery or endoscopic dilation during follow-up in patients with or without a failed PC. RESULTS: A total of 190 patients were included (47: failed PC and 143: passed PC, median follow-up 34.12 months). Patients with a failed PC had higher rates of the primary composite outcome (21.3% vs 1.4%, hazard ratio [HR] 20.3, 95% confidence interval [CI] 4.4-93.7, P < 0.001) and also secondary outcomes including intestinal surgery (14.9% vs 0.70%, P < 0.001), endoscopic dilation (14.9% vs 0.70%, P < 0.001), admissions (23.3% vs 5.7%, P < 0.001), and clinical flares (43.9% vs 27.7%, P = 0.005) during follow-up compared with controls. Failed PC was the only statistically significant factor for surgery and/or endoscopic dilation, regardless of a B2/B3 phenotype at baseline. In sensitivity analyses restricted only to patients with a stricturing phenotype (n = 73), a failed PC still predicted the long-term composite outcome (HR 8.68, 95% CI 1.72-43.68, P = 0.002). Of the 190 patients ingesting a PC, only 1 patient with a failed PC had 48 hours of self-limiting mild symptoms. DISCUSSION: Patients with clinically stable CD with a failed PC have worse long-term clinical outcomes than those without, independently of the CD phenotype. Standalone PC may serve as a novel, safe, and affordable prognostic examination to identify patients with quiescent CD who have a higher risk for future worse clinical outcomes.


Assuntos
Endoscopia por Cápsula , Doença de Crohn , Obstrução Intestinal , Humanos , Doença de Crohn/diagnóstico , Estudos Prospectivos , Obstrução Intestinal/etiologia , Obstrução Intestinal/diagnóstico , Constrição Patológica
20.
Curr Opin Gastroenterol ; 39(3): 227-233, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37144540

RESUMO

PURPOSE OF REVIEW: Capsule endoscopy is widely recognized as a safe and effective procedure to evaluate the small bowel and/or the colon noninvasively. Although infrequent, capsule retention is the most feared adverse event related to this technique. A better knowledge of risk factors, improvement of patients' selection and precapsule patency assessment may further contribute to reducing the incidence of capsule retention, even in patients at increased risk for this complication. RECENT FINDINGS: This review addresses the main risk factors for capsule retention, strategies for risk reduction such as patients' selection, dedicated cross-sectional imaging and rational use of the patency capsule, as well as management options and outcomes in the case of capsule retention. SUMMARY: Capsule retention is infrequent, and it is usually manageable conservatively with favorable clinical outcomes. Patency capsules and dedicated small-bowel cross-sectional techniques such as CT or MR enterography should be used selectively and are both effective in decreasing the rate of capsule retention. However, none of them can completely eliminate the risk of retention.


Assuntos
Endoscopia por Cápsula , Humanos , Endoscopia por Cápsula/métodos , Intestino Delgado/diagnóstico por imagem , Fatores de Risco , Colo , Incidência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA