Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 435
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 413(16): 4237-4246, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33948704

RESUMO

Methamphetamine (MA) is a highly addictive and illegal psychostimulant drug and is currently one of the most commonly abused illicit drugs in the world. The on-site rapid detection of trace amounts of MA and screening illicit drugs in clandestine laboratories is important for drug enforcement agencies and the forensic community in general. However, detecting methamphetamine in the presence of nicotine and cigarette smoke by ion mobility spectrometry faces difficulty due to the overlapped spectral peaks of methamphetamine and nicotine. In this work, a new method was developed to detect MA using pyridine as a dopant in the presence of nicotine by a homemade ion mobility spectrometry. The reduced mobilities of MA and nicotine were measured under the temperatures of the drift tube from 40 to 120 °C and doping with pyridine. The result shows that the temperature of 100 °C is beneficial to resolve the two substances. The concentration of doped pyridine is optimized to be 18 ppm. In this doped experiment, the reaction rate of nicotine is higher than that of MA by measuring the instrumental responses of MA and nicotine. No matter how high the nicotine content is, the interference of nicotine can be eliminated in the detection of MA doped with pyridine. This method is also successfully applied for the determination of MA and nicotine simultaneously in real saliva samples. The limit of detection of MA was measured to be about 0.5 ng/µL. The promising results in this work provide an effective method for on-site detection of MA.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Metanfetamina/análise , Nicotina/análise , Saliva/química , Humanos , Drogas Ilícitas/análise , Espectrometria de Mobilidade Iônica/métodos , Limite de Detecção , Piridinas/química , Detecção do Abuso de Substâncias/métodos
2.
Anal Bioanal Chem ; 413(8): 2147-2161, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33517480

RESUMO

Resolution of cathinone enantiomers in equine anti-doping analysis is becoming more important to distinguish the inadvertent ingestion of plant-based products from those of deliberate administration of designer synthetic analogs. With this in mind, a rapid and sensitive method was developed and validated for the detection, resolution and quantitative determination of cathinone enantiomers in horse blood plasma and urine. The analytes were recovered from the blood plasma and urine matrices by using a liquid-liquid extraction after adjusting the pH to 9. The recovered analytes were derivatized with Nα-(2,4-dinitro-5-fluorophenyl)-L-valinamide, a chiral derivatizing agent analogous to Marfey's reagent. The resulting diastereoisomers were baseline resolved under a reversed-phase liquid chromatographic condition. Derivatization of the analytes not only allowed the separation of the enantiomers using cost-effective traditional liquid chromatography conditions and reversed-phase columns but also increased the sensitivity, at least to an order of magnitude, when tandem mass spectrometry is used for the detection. A limit of detection of 0.05 ng/mL was achieved for cathinone enantiomers for both matrices. Acceptable intraday and interday precision and accuracy along with satisfactory dilution accuracy and precision were observed during the method validation. The method suitability was tested using the post administration urine samples collected after single doses of cathinone and ephedrine as single-enantiomeric form and methcathinone as racemic form. Finally, a proof of concept of the isomeric ratio in urine samples to distinguish the presence of cathinone as a result of accidental ingestion of plant-based product from that of an illicit use of a designer product is demonstrated. To the best of our knowledge, this is the first such work where cathinone enantiomers were resolved and quantified in horse blood plasma and urine at sub nanogram levels.


Assuntos
Alcaloides/sangue , Alcaloides/urina , Estimulantes do Sistema Nervoso Central/sangue , Estimulantes do Sistema Nervoso Central/urina , Cavalos/sangue , Cavalos/urina , Alcaloides/análise , Animais , Estimulantes do Sistema Nervoso Central/análise , Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo , Limite de Detecção , Estereoisomerismo , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos
3.
Am J Forensic Med Pathol ; 42(1): 57-61, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32773434

RESUMO

ABSTRACT: Synthetic cathinones are one of the major pharmacological families of new psychoactive substances and 4-methylethcathinone (4-MEC) has emerged in recent years as a recreational psychostimulant. We report a case of a 35-year-old man found dead and naked at home by his friend. Although no anatomic cause of death was observed at autopsy, toxicological analysis identified 4-MEC and hydroxyzine at therapeutic level (160 ng/mL). 4-Methylethcathinone was quantified in autopsy samples by a validated method consisting in liquid-liquid extraction and gas chromatography coupled to tandem mass spectrometry: peripheral blood, 14.6 µg/mL; cardiac blood, 43.4 µg/mL; urine, 619 µg/mL; vitreous humor, right 2.9 µg/mL and left 4.4 µg/mL; bile, 43.5 µg/mL; and gastric content, 28.2 µg/mL. The cause of death was 4-MEC intoxication and the manner of death could be either accidental or suicidal. The literature concerning 4-MEC was reviewed, focusing on distribution in classical postmortem matrices and 4-MEC metabolism and postmortem redistribution and stability.


Assuntos
Anfetaminas/intoxicação , Estimulantes do Sistema Nervoso Central/intoxicação , Propiofenonas/intoxicação , Adulto , Anfetaminas/análise , Bile/química , Estimulantes do Sistema Nervoso Central/análise , Overdose de Drogas , Cromatografia Gasosa-Espectrometria de Massas , Conteúdo Gastrointestinal/química , Humanos , Masculino , Propiofenonas/análise , Abuso de Substâncias por Via Intravenosa/complicações , Corpo Vítreo/química
4.
Int J Legal Med ; 134(1): 229-241, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31735981

RESUMO

This study centres on the prevalence of new psychoactive substances (NPS) stimulant use, and its relevance as a cause of death amongst individuals between the ages of 12 and 35 in the greater Cologne area. An automated solid-phase extraction-liquid chromatography-tandem mass spectrometry method was developed for the determination of 97 stimulants in urine (including conventional stimulants, e.g. amphetamine and MDMA), of which 68 analytes were fully validated for quantification. Samples of urine or kidney tissue (in cases where urine was unavailable) of 268 deceased were collected, during autopsy, between January 2011 and May 2017 and analyzed. Blood (if available) was also investigated in cases where urine/kidney samples were tested positive for NPS. An intake of stimulants (including NPS stimulants) was proven in 50 cases. In 33 cases, only conventional stimulants were detected. A total of 17 cases were tested positive for NPS. Of the 17 NPS-positive cases, 13 were also tested positive for other conventional drugs of abuse (mostly amphetamine and MDMA). In six NPS-positive cases, at least three different NPS were proven to be ingested. Due to the determined blood concentrations, NPS was assigned as the leading cause of death, or of toxicological relevance, in the cause of death in only 5 cases. In two of the cases, NPS was judged to be a component of a multidrug poisoning, but of minor relevance.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Detecção do Abuso de Substâncias/métodos , Adolescente , Adulto , Anfetaminas/análise , Autopsia , Causas de Morte , Criança , Cromatografia Líquida , Feminino , Alemanha/epidemiologia , Humanos , Ketamina/análise , Masculino , Metilfenidato/análise , Prevalência , Psicotrópicos/classificação , Extração em Fase Sólida , Espectrometria de Massas em Tandem
5.
Analyst ; 145(8): 3038-3048, 2020 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-32134419

RESUMO

The use of synthetic stimulants, including designer cathinones, remains a significant concern worldwide. Thus, the detection and identification of synthetic cathinones in biological matrices is of paramount importance for clinical and forensic laboratories. In this study, distribution of mephedrone and its metabolites was investigated in fingerprints. Following a controlled human mephedrone administration (100 mg nasally insufflated), two mass spectrometry-based methods for fingerprint analysis have been evaluated. The samples deposited on triangular pieces of chromatography paper were directly analysed under ambient conditions by paper spray-mass spectrometry (PS-MS) while those deposited on glass cover slips were extracted and analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS method was 5-6 times more sensitive than PS-MS but required sample preparation and longer analysis time. Mephedrone was detected in 62% and in 38% of all post-administration samples analysed by LC-MS/MS and PS-MS, respectively. Nor-mephedrone was the only metabolite detected in 3.8% of all samples analysed by LC-MS/MS. A large inter- and intra-subject variation was observed for mephedrone which may be due to several factors, such as the applied finger pressure, angle and duration of contact with the deposition surface and inability to control the 'amount' of collected fingerprint deposits. Until these limitations are addressed, we suggest that the sole use of fingerprints can be a useful diagnostic tool in qualitative rather than quantitative analysis, and requires a confirmatory analysis in a different biological matrix.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Cromatografia Líquida de Alta Pressão/métodos , Dermatoglifia , Metanfetamina/análogos & derivados , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Administração por Inalação , Estimulantes do Sistema Nervoso Central/administração & dosagem , Estimulantes do Sistema Nervoso Central/metabolismo , Humanos , Masculino , Metanfetamina/administração & dosagem , Metanfetamina/análise , Metanfetamina/metabolismo , Papel , Espectrometria de Massas em Tandem/instrumentação
6.
Int J Mol Sci ; 21(17)2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32839415

RESUMO

Methamphetamine (MA) is a highly addictive central nervous system stimulant. Drug addiction is not a static condition but rather a chronically relapsing disorder. Hair is a valuable and stable specimen for chronic toxicological monitoring as it retains toxicants and metabolites. The primary focus of this study was to discover the metabolic effects encompassing diverse pathological symptoms of MA addiction. Therefore, metabolic alterations were investigated in human hair following heavy MA abuse using both targeted and untargeted mass spectrometry and through integrated network analysis. The statistical analyses (t-test, variable importance on projection score, and receiver-operator characteristic curve) demonstrated that 32 metabolites (in targeted metabolomics) as well as 417 and 224 ion features (in positive and negative ionization modes of untargeted metabolomics, respectively) were critically dysregulated. The network analysis showed that the biosynthesis or metabolism of lipids, such as glycosphingolipids, sphingolipids, glycerophospholipids, and ether lipids, as well as the metabolism of amino acids (glycine, serine and threonine; cysteine and methionine) is affected by heavy MA abuse. These findings reveal crucial metabolic effects caused by MA addiction, with emphasis on the value of human hair as a diagnostic specimen for determining drug addiction, and will aid in identifying robust diagnostic markers and therapeutic targets.


Assuntos
Anfetamina/análise , Estimulantes do Sistema Nervoso Central/análise , Cabelo/química , Metanfetamina/análise , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Adulto , Aminoácidos/química , Aminoácidos/classificação , Aminoácidos/isolamento & purificação , Aminoácidos/metabolismo , Anfetamina/administração & dosagem , Anfetamina/metabolismo , Estudos de Casos e Controles , Estimulantes do Sistema Nervoso Central/administração & dosagem , Estimulantes do Sistema Nervoso Central/metabolismo , Glicerofosfolipídeos/química , Glicerofosfolipídeos/classificação , Glicerofosfolipídeos/isolamento & purificação , Glicerofosfolipídeos/metabolismo , Glicoesfingolipídeos/química , Glicoesfingolipídeos/classificação , Glicoesfingolipídeos/isolamento & purificação , Glicoesfingolipídeos/metabolismo , Humanos , Metabolismo dos Lipídeos/fisiologia , Masculino , Metabolômica/métodos , Metanfetamina/administração & dosagem , Metanfetamina/metabolismo , Pessoa de Meia-Idade , Análise de Componente Principal , Esfingolipídeos/química , Esfingolipídeos/classificação , Esfingolipídeos/isolamento & purificação , Esfingolipídeos/metabolismo , Detecção do Abuso de Substâncias/métodos , Transtornos Relacionados ao Uso de Substâncias/metabolismo , Espectrometria de Massas em Tandem
7.
Forensic Sci Med Pathol ; 16(4): 577-585, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32852692

RESUMO

The purpose of this study was to assess the incidence of fatal hemorrhage complicated with methamphetamine (MA) poisoning and to examine the postmortem computed tomography (PMCT) features of fatal intracerebral hemorrhage (ICH) with and without MA poisoning. The study also attempted to determine the differences in PMCT between those two groups. Consecutive medicolegal autopsy data from November 2011 to February 2018 were searched for 3044 cases. First, the incidence and distribution of all cases of nontraumatic fatal hemorrhage with various causes were examined. Second, cases of ICH on the basal ganglia and brain stem were extracted. The PMCT findings were compared with respect to nine parameters: volume of hematoma, ventricular perforation, midline shift distance, aortic calcification, calcification of aortic valve, calcification of coronary artery, cardiothoracic ratio, circumference of ascending aorta, and volume of bladder contents. Of the 3044 cases, 97 were nontraumatic fatal hemorrhage; of these 97 cases, 20 were classified as MA poisoning with 9 ICH cases, and 60 cases were classified as non-MA poisoning with 14 ICH cases. A statistically significant difference in ages was observed between the two groups. On PMCT comparison of ICH, statistically significant differences were evident in the midline shift distance and calcification of the aortic valve. Forensic radiologists should be aware of the possibility of ICH with MA poisoning if fatal hemorrhage is detected on PMCT. Younger age, less calcification of the aortic valve, and a remarkable midline shift may be the keys to recognition.


Assuntos
Estimulantes do Sistema Nervoso Central/intoxicação , Hemorragia Cerebral/diagnóstico por imagem , Metanfetamina/intoxicação , Tomografia Computadorizada Multidetectores , Adulto , Distribuição por Idade , Valva Aórtica/diagnóstico por imagem , Autopsia/métodos , Estimulantes do Sistema Nervoso Central/análise , Hemorragia Cerebral/mortalidade , Feminino , Patologia Legal , Humanos , Masculino , Metanfetamina/análise , Pessoa de Meia-Idade , Distribuição por Sexo , Transtornos Relacionados ao Uso de Substâncias/mortalidade , Calcificação Vascular/diagnóstico por imagem , Imagem Corporal Total
8.
Biochem Biophys Res Commun ; 514(1): 134-139, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31027736

RESUMO

Here, we describe a study of screen characterization of aptamers targeting the chiral drug ephedrine using the non-immobilized graphene oxide (GO) SELEX. The improved method of long and short chains was here used to prepare the ssDNA library. The Resonance Rayleigh Scattering (RRS) method was first used to monitor the screening process. Through high-throughput sequencing, the genetic sequence data of 90,487 aptamers were obtained. Through the analysis of the parameters of free energy value and secondary structure prediction model of high repeatability sequence, the 10 candidate sequences were identified. Finally, a best-fit aptamer named EP08 was identified by combining the dissociation experiment. The binding affinity and binding mechanism of the aptamer and target were analyzed using an isothermal titration colorimetry (ITC) experiment and circular dichromatic (CD) experiment. The binding affinity (Kd) of the EP08 aptamer to ephedrine is approximately 2.86 ±â€¯0.24 µM. This novel DNA aptamer will help in the future development of a new method for the identification and detection of chiral drug ephedrine.


Assuntos
Aptâmeros de Nucleotídeos/química , Estimulantes do Sistema Nervoso Central/análise , Efedrina/análise , Técnica de Seleção de Aptâmeros/métodos , Sequência de Bases , Colorimetria , DNA de Cadeia Simples/química , Grafite/química , Termodinâmica
9.
Drug Dev Ind Pharm ; 45(1): 139-146, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30231652

RESUMO

Lisdexamfetamine dimesylate (LDX), a long-acting prodrug stimulant indicated for the treatment of the attention-deficit/hyperactivity disorder (ADHD), was subjected to forced degradation studies by acid and alkaline hydrolysis and the degradation profile was studied. To obtain between 10-30% of degraded product, acid and alkaline conditions were assessed with solutions of 0.01 M, 0.1 M, 0.5 M, and 1 M of DCl and NaOD. These solutions were analyzed through 1 H NMR spectra. Acid hydrolysis produced no degradation in 0.01 M and 0.1 M DCl and 4.38%, 9.69%, and 17.75% of degradation LDX, respectively, in 0.5 M, 1 M (4h) and 1 M (4 + 12 h) DCl. And alkaline hydrolysis produced no degradation in 0.01 M and 0.1 M DCl and a degradation LDX extension of 8.5%, 14.30%, and 22.91%, respectively, in 0.5 M, 1 M (4h) and 1 M (4 + 12 h) NaOD. LDX solutions subjected to 1 M (4 + 12 h) acid and alkaline hydrolysis were evaluated by NMR spectra (1 H NMR, 13 C NMR, HSQC and HMBC). LDX degradation product (DP) was identified and its structure elucidated as a diastereoisomer of LDX: (2R)-2,6-diamino-N-[(2S)-1-phenylpropan-2-yl] hexanamide without their physical separation.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Estimulantes do Sistema Nervoso Central/metabolismo , Dimesilato de Lisdexanfetamina/análise , Dimesilato de Lisdexanfetamina/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Estabilidade de Medicamentos
10.
Langmuir ; 34(49): 14834-14841, 2018 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-30089211

RESUMO

The development of fast and cheap high-throughput platforms for the detection of environmental contaminants is of particular importance to understand the human-related impact on the environment. The application of DNA-directed immobilization (DDI) of IgG molecules is currently limited to the clinical diagnostics scenario, possibly because of the high costs of production of such addressable platforms. We here describe the efficient and specific hybridization of an antibody-oligonucleotide conjugate to a short 12-mer capture probe. The specific antibody used is a monoclonal antibody against caffeine, a stimulant and important anthropogenic marker. With this work, we hope to contribute to broadening the application potential of DDI to environmental markers in order to develop cheaper and more stable high-throughput screening platforms for standard routine analysis of pollutants in a variety of complex matrices.


Assuntos
Anticorpos Monoclonais/imunologia , DNA/química , Ácidos Nucleicos Imobilizados/química , Imunoensaio/métodos , Oligodesoxirribonucleotídeos/química , Anticorpos Monoclonais/química , Cafeína/imunologia , Estimulantes do Sistema Nervoso Central/análise , Estimulantes do Sistema Nervoso Central/imunologia , DNA/genética , Sondas de DNA/química , Sondas de DNA/genética , Eletroforese em Gel de Poliacrilamida , Ensaios de Triagem em Larga Escala/métodos , Ácidos Nucleicos Imobilizados/genética , Hibridização de Ácido Nucleico , Oligodesoxirribonucleotídeos/genética , Estudo de Prova de Conceito , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/imunologia
11.
Handb Exp Pharmacol ; 252: 543-566, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29896656

RESUMO

Wastewater-based epidemiology (WBE) complements existing epidemiology-based estimation techniques and provides objective, evidence-based estimates of illicit drug use. After consumption, biomarkers - drugs and their metabolites - excreted to toilets and flushed into urban sewer networks can be measured in raw wastewater samples. The quantified loads can serve as an estimate for the collective consumption of all people contributing to the wastewater sample. This transdisciplinary approach, further explained in this chapter, has developed, matured and is now established for monitoring substances such as cocaine and amphetamine-type stimulants. Research currently underway is refining WBE to new applications including new psychoactive substances (NPS).


Assuntos
Drogas Ilícitas/análise , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Águas Residuárias/análise , Anfetamina/análise , Estimulantes do Sistema Nervoso Central/análise , Cocaína/análise , Humanos
12.
Rapid Commun Mass Spectrom ; 31(15): 1290-1296, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28508503

RESUMO

RATIONALE: Continuously refining and advancing the strategies and methods employed in sports drug testing is critical for efficient doping controls. Besides improving and expanding the spectrum of target analytes, alternative test matrices have warranted in-depth evaluation as they commonly allow for minimal-/non-invasive and non-intrusive sample collection. In this study, the potential of exhaled breath (EB) as doping control specimen was assessed. METHODS: EB collection devices employing a non-woven electret-based air filter unit were used to generate test specimens, simulating a potential future application in doping controls. A multi-analyte sports drug testing approach configured for a subset of 12 model compounds that represent specific classes of substances prohibited in sports (anabolic agents, hormone and metabolic modulators, stimulants, and beta-blockers) was established using unispray liquid chromatography/tandem mass spectrometry (LC/MS/MS) and applied to spiked and elimination study EB samples. The test method was characterized concerning specificity, assay imprecision, and limits of detection. RESULTS: The EB collection device allowed for retaining and extracting all selected model compounds from the EB aerosol. Following elution and concentration, LC/MS/MS analysis enabled detection limits between 5 and 100 pg/filter and imprecisions ranging from 3% to 20% for the 12 selected model compounds. By means of EB samples from patients and participants of administration studies, the elimination of relevant compounds and, thus, their traceability in EB for doping control purposes, was investigated. Besides stimulants such as methylhexaneamine and pseudoephedrine, also the anabolic-androgenic steroid dehydrochloromethyltestosterone, the metabolic modulator meldonium, and the beta-blocker bisoprolol was detected in exhaled breath. CONCLUSIONS: The EB aerosol has provided a promising proof-of-concept suggesting the expansion of this testing strategy as a complement to currently utilized sports drug testing programs.


Assuntos
Testes Respiratórios/métodos , Cromatografia Líquida/métodos , Dopagem Esportivo , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Adulto , Anabolizantes/análise , Androgênios/análise , Estimulantes do Sistema Nervoso Central/análise , Feminino , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Modelos Químicos , Reprodutibilidade dos Testes , Adulto Jovem
13.
Forensic Sci Med Pathol ; 13(3): 355-358, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28656354

RESUMO

Caffeine is not usually perceived as a drug by most people because it is found in many foods and drinks, including caffeinated energy drinks, as well as in over the counter analgesics and cold preparations. Recently in Poland it has become increasingly common to take pure caffeine, bought through online stores, as a psychoanaleptic. This creates a much higher risk of severe and even fatal poisoning in comparison with the risk associated with the abuse of food products and non-prescription medicines containing low doses of caffeine. This paper presents three different cases of poisoning that occurred when pure caffeine was taken as psychostimulant; in cases 1 and 2 poisoning was the result of a single overdose, while in the case 3 poisoning resulted from a cumulative overdose. In the case 1 there was a severe intoxication (persistent vomiting, hypotension, tremor), and the concentration of caffeine in the blood was found to be 80.16 µg/mL. The patient was treated using hemodialysis, which caused a rapid decrease in blood levels of caffeine and relief of the clinical symptoms of poisoning. Cases 2 and 3 were fatal poisonings, and recorded levels of caffeine in post mortem blood samples were 140.64 µg/mL and 613.0 µg/mL. In case 2 the patient died 10 min after admission to hospital as a result of sudden cardiac arrest, which was preceded by an attack of convulsions, and in case 3 death occurred in home and was also sudden in nature. Taking pure caffeine as a stimulant is associated with a high risk of overdose and the development of serious and even fatal poisoning, and those using pure caffeine are generally completely unaware of these risks. In such cases, death is usually sudden due to functional mechanisms.


Assuntos
Cafeína/intoxicação , Estimulantes do Sistema Nervoso Central/intoxicação , Overdose de Drogas , Adulto , Cafeína/análise , Estimulantes do Sistema Nervoso Central/análise , Creatina Quinase/sangue , Evolução Fatal , Feminino , Humanos , Masculino , Intoxicação/terapia , Diálise Renal , Adulto Jovem
14.
Anal Chem ; 88(21): 10513-10522, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27715011

RESUMO

A microfluidic device is being developed by University of California-Santa Barbara as part of a joint effort with the United States Army to develop a portable, rapid drug detection device. Surface-enhanced Raman spectroscopy (SERS) is used to provide a sensitive, selective detection technique within the microfluidic platform employing metallic nanoparticles as the SERS medium. Using several illicit drugs as analytes, the work presented here describes the efforts of the Edgewood Chemical Biological Center to optimize the microfluidic platform by investigating the role of nanoparticle material, nanoparticle size, excitation wavelength, and capping agents on the performance, and drug concentration detection limits achievable with Ag and Au nanoparticles that will ultimately be incorporated into the final design. This study is particularly important as it lays out a systematic comparison of limits of detection and potential interferences from working with several nanoparticle capping agents-such as tannate, citrate, and borate-which does not seem to have been done previously as the majority of studies only concentrate on citrate as the capping agent. Morphine, cocaine, and methamphetamine were chosen as test analytes for this study and were observed to have limits of detection (LOD) in the range of (1.5-4.7) × 10-8 M (4.5-13 ng/mL), with the borate capping agent having the best performance.


Assuntos
Dispositivos Lab-On-A-Chip , Análise Espectral Raman/instrumentação , Detecção do Abuso de Substâncias/instrumentação , Analgésicos Opioides/análise , Anestésicos Locais/análise , Estimulantes do Sistema Nervoso Central/análise , Cocaína/análise , Ouro/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Metanfetamina/análise , Morfina/análise , Prata/química , Propriedades de Superfície
15.
Int J Legal Med ; 130(2): 381-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26071183

RESUMO

Methylone is a synthetic derivative of cathinone. It is sold principally on the Internet in powder form under the name «bath salts¼. Deaths following consumption are very rare. This report details the first case of a death in France (a 21-year-old man), following ingestion of methylone during an evening with friends. Anoxia was observed at the time of autopsy. Toxicological analyses highlighted a consumption of methylone and cannabis. However, biological analyses showed an absence of ethanol, cocaine, amphetamines, and opiate derivatives. Likewise, no medications were found. High concentrations of methylone were found in the peripheral blood (3.13 mg/L) and in the central blood (6.64 mg/L). Its presence in the gastric contents provides evidence that the substance was taken orally. The dosage of δ9-tetrahydrocannabinol (THC) suggests a recent cannabis consumption (THC 12.9 µg/L, THC-COOH 29.3 µg/L, 11-OH-THC 4.9 µg/L). This case illustrates that the consumption of methylone, which has a reputation of being less «powerful¼ than ecstasy, is not without its dangers.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Estimulantes do Sistema Nervoso Central/intoxicação , Metanfetamina/análogos & derivados , Administração Oral , Bile/química , Estimulantes do Sistema Nervoso Central/administração & dosagem , Cromatografia Líquida de Alta Pressão , Dronabinol/análise , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas , Conteúdo Gastrointestinal/química , Humanos , Masculino , Metanfetamina/administração & dosagem , Metanfetamina/análise , Metanfetamina/intoxicação , Psicotrópicos/análise , Transtornos Relacionados ao Uso de Substâncias/complicações , Corpo Vítreo/química , Adulto Jovem
16.
Ther Drug Monit ; 38(1): 98-107, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26349081

RESUMO

BACKGROUND: For psychostimulants, a marked individual variability in the dose-response relationship and large differences in plasma concentrations after similar doses are known. Therefore, optimizing the efficacy of these drugs is at present the most promising way to exploit their full pharmacological potential. Moreover, it seems important to examine oral fluid as less invasive biological matrix for its benefit in therapeutic drug monitoring for patients with hyperkinetic disorder. METHODS: A high-performance liquid chromatography method for quantification of methylphenidate (MPH), dexamphetamine (DXA), and atomoxetine in serum and oral fluid has been developed and validated. The analytical procedure involves liquid-liquid extraction, derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a label and chromatographic separation on a Phenomenex Gemini-NX C18 analytical column using gradient elution with water-acetonitrile. The derivatized analytes were detected at 330 nm (excitation wavelength) and 440 nm (emission wavelength). To examine the oral fluid/serum ratios, oral fluid samples were collected simultaneously to blood samples from patients with hyperkinetic disorder. RESULTS: The method allows quantification of all analytes in serum and oral fluid within 16 minutes under the same or similar conditions. Oral fluid/serum ratios for MPH and DXA were highly variable and showed an accumulation of these drugs in oral fluid. CONCLUSIONS: The developed method covers the determination of MPH, DXA, and atomoxetine concentrations in serum and oral fluid after the intake of therapeutic doses. Oral fluid samples are useful for the qualitative detection of MPH and DXA.


Assuntos
Cloridrato de Atomoxetina/análise , Cromatografia Líquida de Alta Pressão/métodos , Dextroanfetamina/análise , Metilfenidato/análise , Adolescente , Inibidores da Captação Adrenérgica/análise , Inibidores da Captação Adrenérgica/farmacocinética , Adulto , Cloridrato de Atomoxetina/farmacocinética , Estimulantes do Sistema Nervoso Central/análise , Criança , Dextroanfetamina/farmacocinética , Monitoramento de Medicamentos , Feminino , Humanos , Extração Líquido-Líquido , Masculino , Metilfenidato/farmacocinética , Pessoa de Meia-Idade , Espectrometria de Fluorescência/métodos , Adulto Jovem
17.
Anal Bioanal Chem ; 408(23): 6329-36, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27395357

RESUMO

Ephedrine is one of the main precursor compounds used in the illegal production of amphetamines and related drugs. Actually, conventional analytical methods such as high-performance liquid chromatography (HPLC), capillary electrophoresis (CE), and gas chromatography-mass spectrometry (GC-MS) are used for the detection of ephedrine; sadly, these methods require qualified personnel and are time-consuming and expensive. In order to overcome these problems, in recent years, different methods have been developed based on the surface plasmon resonance (SPR) and electrochemical method. In this work, we present a simple, rapid, and effective method to detect the presence of ephedrine in solution, based on competitive fluorescence resonance energy transfer (FRET) assay. The antibody anti-ephedrine and ephedrine derivative were produced and labeled respectively, with two different fluorescent probes (donor and acceptor). The change in FRET signal intensity between donor and acceptor ephedrine compounds gives the possibility of detecting ephedrine traces of at least 0.81 ± 0.04 ppm (LOD). Graphical abstract A new Time-resolved Fluorescence Resonance Energy Transfer (FRET) assay for ephedrine detection.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Efedrina/análise , Transferência Ressonante de Energia de Fluorescência/métodos , Animais , Ephedra sinica/química , Corantes Fluorescentes/química , Imunoensaio/métodos , Imunoglobulina G/química , Limite de Detecção , Coelhos
18.
BMC Public Health ; 16(1): 1035, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27716139

RESUMO

BACKGROUND: Monitoring the scale of pharmaceuticals, illicit and licit drugs consumption is important to assess the needs of law enforcement and public health, and provides more information about the different trends within different countries. Community drug use patterns are usually described by national surveys, sales and seizure data. Wastewater-based epidemiology (WBE) has been shown to be a reliable approach complementing such surveys. METHOD: This study aims to compare and correlate the consumption estimates of pharmaceuticals, illicit drugs, alcohol, nicotine and caffeine from wastewater analysis and other sources of information. Wastewater samples were collected in 2015 from 8 different European cities over a one week period, representing a population of approximately 5 million people. Published pharmaceutical sale, illicit drug seizure and alcohol, tobacco and caffeine use data were used for the comparison. RESULTS: High agreement was found between wastewater and other data sources for pharmaceuticals and cocaine, whereas amphetamines, alcohol and caffeine showed a moderate correlation. methamphetamine and 3,4-methylenedioxymethamphetamine (MDMA) and nicotine did not correlate with other sources of data. Most of the poor correlations were explained as part of the uncertainties related with the use estimates and were improved with other complementary sources of data. CONCLUSIONS: This work confirms the promising future of WBE as a complementary approach to obtain a more accurate picture of substance use situation within different communities. Our findings suggest further improvements to reduce the uncertainties associated with both sources of information in order to make the data more comparable.


Assuntos
Cafeína , Etanol , Nicotina , Preparações Farmacêuticas , Detecção do Abuso de Substâncias , Águas Residuárias/química , Poluentes Químicos da Água/análise , Consumo de Bebidas Alcoólicas , Anfetaminas/administração & dosagem , Anfetaminas/análise , Bebidas , Cafeína/administração & dosagem , Cafeína/análise , Estimulantes do Sistema Nervoso Central/administração & dosagem , Estimulantes do Sistema Nervoso Central/análise , Cidades , Cocaína/administração & dosagem , Cocaína/análise , Comércio , Etanol/administração & dosagem , Etanol/análise , Europa (Continente) , Humanos , Drogas Ilícitas/análise , Metanfetamina/administração & dosagem , Metanfetamina/análise , N-Metil-3,4-Metilenodioxianfetamina/administração & dosagem , N-Metil-3,4-Metilenodioxianfetamina/análise , Nicotina/administração & dosagem , Nicotina/análise , Preparações Farmacêuticas/administração & dosagem , Preparações Farmacêuticas/análise , Transtornos Relacionados ao Uso de Substâncias , Nicotiana/química , Uso de Tabaco
19.
Appetite ; 103: 353-357, 2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27142708

RESUMO

The purpose of the current study was to examine the knowledge of caffeine content of a variety of caffeinated beverages among Dutch university students. A pencil-and-paper survey was conducted among N = 800 Dutch students. Most participants (87.8%) reported consuming caffeinated beverages during the past 24 h. Their mean ± SD past 24-h caffeine intake from beverages was 144.2 ± 169.5 mg (2.2 ± 3.0 mg/kg bw). Most prevalent sources of caffeine were coffee beverages (50.8%) and tea (34.8%), followed by energy drink (9.2%), cola (4.7%), and chocolate milk (0.5%). Participants had poor knowledge on the relative caffeine content of caffeinated beverages. That is, they overestimated the caffeine content of energy drinks and cola, and underestimated the caffeine content of coffee beverages. If caffeine consumption is a concern, it is important to inform consumers about the caffeine content of all caffeine containing beverages, including coffee and tea. The current findings support previous research that the most effective way to reduce caffeine intake is to limit the consumption of coffee beverages and tea.


Assuntos
Cafeína/administração & dosagem , Estimulantes do Sistema Nervoso Central/administração & dosagem , Estimulantes do Sistema Nervoso Central/análise , Informação de Saúde ao Consumidor , Comportamento de Ingestão de Líquido , Estudantes/psicologia , Adolescente , Adulto , Animais , Conscientização , Cafeína/análise , Cafeína/normas , Bebidas Gaseificadas/análise , Estimulantes do Sistema Nervoso Central/normas , Chocolate/análise , Café/química , Bebidas Energéticas/análise , Feminino , Humanos , Masculino , Leite/química , Países Baixos , Inquéritos e Questionários , Chá/química , Fatores de Tempo , Adulto Jovem
20.
Int J Sport Nutr Exerc Metab ; 26(5): 413-420, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26841433

RESUMO

Many studies have found that some dietary supplement product labels do not accurately reflect the actual ingredients. However, studies have not been performed to determine if ingredients in the same dietary supplement product vary over time. The objective of this study was to assess the consistency of stimulant ingredients in popular sports supplements sold in the United States over a 9-month period. Three samples of nine popular sports supplements were purchased over the 9-month period. The 27 samples were analyzed for caffeine and several other stimulants (including adulterants). The identity and quantity of stimulants were compared with stimulants listed on the label and stimulants found at earlier time points to determine the variability in individual products over the 9-month period. The primary outcome measure was the variability of stimulant amounts in the products examined. Many supplements did not contain the same number and quantity of stimulants at all time points over the 9-month period. Caffeine content varied widely in five of the six caffeinated supplements compared with the initial measurement (-7% to +266%). In addition, the stimulants-synephrine, octopamine, cathine, ephedrine, pseudoephedrine, strychnine, and methylephedrine-occurred in variable amounts in eight of the nine products. The significance of these findings is uncertain: the sample size was insufficient to support statistical analysis. In our sample of nine popular sports supplements, the presence and quantity of stimulants varied over a 9-month period. However, future studies are warranted to determine if the variability found is significant and generalizable to other supplements.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Suplementos Nutricionais , Rotulagem de Alimentos , Esportes , Cafeína/análise , Relação Dose-Resposta a Droga , Efedrina/análogos & derivados , Efedrina/análise , Humanos , Octopamina/análise , Fenilpropanolamina/análise , Projetos Piloto , Pseudoefedrina/análise , Estricnina/análise , Sinefrina/análise , Fatores de Tempo , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA