Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Assoc Res Otolaryngol ; 25(3): 277-284, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38622382

RESUMO

BACKGROUND: Sheep have been proposed as a large-animal model for studying cochlear implantation. However, prior sheep studies report that the facial nerve (FN) obscures the round window membrane (RWM), requiring FN sacrifice or a retrofacial opening to access the middle-ear cavity posterior to the FN for cochlear implantation. We investigated surgical access to the RWM in Hampshire sheep compared to Suffolk-Dorset sheep and the feasibility of Hampshire sheep for cochlear implantation via a facial recess approach. METHODS: Sixteen temporal bones from cadaveric sheep heads (ten Hampshire and six Suffolk-Dorset) were dissected to gain surgical access to the RWM via an extended facial recess approach. RWM visibility was graded using St. Thomas' Hospital (STH) classification. Cochlear implant (CI) electrode array insertion was performed in two Hampshire specimens. Micro-CT scans were obtained for each temporal bone, with confirmation of appropriate electrode array placement and segmentation of the inner ear structures. RESULTS: Visibility of the RWM on average was 83% in Hampshire specimens and 59% in Suffolk-Dorset specimens (p = 0.0262). Hampshire RWM visibility was Type I (100% visibility) for three specimens and Type IIa (> 50% visibility) for seven specimens. Suffolk-Dorset RWM visibility was Type IIa for four specimens and Type IIb (< 50% visibility) for two specimens. FN appeared to course more anterolaterally in Suffolk-Dorset specimens. Micro-CT confirmed appropriate CI electrode array placement in the scala tympani without apparent basilar membrane rupture. CONCLUSIONS: Hampshire sheep appear to be a suitable large-animal model for CI electrode insertion via an extended facial recess approach without sacrificing the FN. In this small sample, Hampshire specimens had improved RWM visibility compared to Suffolk-Dorset. Thus, Hampshire sheep may be superior to other breeds for ease of cochlear implantation, with FN and facial recess anatomy more similar to humans.


Assuntos
Implante Coclear , Modelos Animais , Animais , Implante Coclear/métodos , Ovinos , Osso Temporal , Janela da Cóclea/cirurgia , Janela da Cóclea/anatomia & histologia , Implantes Cocleares
2.
Int. arch. otorhinolaryngol. (Impr.) ; 23(3): 281-291, July-Sept. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1040016

RESUMO

Abstract Introduction Posterior tympanotomy through facial recess (FR) is the conventional and most preferred approach to facilitate cochlear implantation, especially when the electrode is inserted through the round window. The complications of the FR approach can be minimized by proper understanding of the anatomy of the FR. Objective The present study was undertaken to assess the various parameters of FR and round window visibility, which may be of relevance for cochlear implant surgery. Methods Thirty-five normal wet human cadaveric temporal bones were studied by dissection for anatomy of FR and posterior tympanum. Photographs were taken with an 18megapixels digital camera, which were then imported to a computer to determine various parameters. Results The mean distance from the take-off point/crotch of the chorda tympani nerve (CTN) to the stylomastoid foramen was 4.08 ± 0.8 mm(range of 2.06 - 5.5mm). The variations in the course of the CTN included origin at the level of the lateral semicircular canal. Themean chorda-facial angle in our study was 26.91° ± 1.19°, with a range of 25° to 28.69°. The mean FR length ranged between 9.4 mm and 18.56 mm (mean of 12.41 ± 2.91mm) and varied with the origin of the CTN and pneumatization of temporal bone. The average maximum width of the FR was 2.93 ± 0.4 mm (range 2.24-3.45 mm) and the mean width of the FR at the level of the round window was 2.65 ± 0.41 mm. Conclusion The FR approach provides good access to the round windowmembrane in all cases. In some cases, table adjustment is required.


Assuntos
Humanos , Adulto , Janela da Cóclea/anatomia & histologia , Implante Coclear , Nervo Facial/anatomia & histologia , Osso Temporal/anatomia & histologia , Membrana Timpânica/anatomia & histologia , Cadáver , Nervo da Corda do Tímpano/anatomia & histologia , Dissecação
3.
Braz. j. otorhinolaryngol. (Impr.) ; 85(4): 435-446, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019586

RESUMO

Abstract Introduction: Various aspects of the round window anatomy and anatomy of posterior tympanum have relevant implications for designing cochlear implant electrodes and visualizing the round window through facial recess. Preoperative information about possible anatomical variations of the round window and its relationships to the adjacent neurovascular structures can help reduce complications in cochlear implant surgery. Objective: The present study was undertaken to assess the common variations in round window anatomy and the relationships to structures of the tympanum that may be relevant for cochlear implant surgery. Methods: Thirty-five normal wet human cadaveric temporal bones were studied by dissection for anatomy of round window and its relation to facial nerve, carotid canal, jugular fossa and other structures of posterior tympanum. The dissected bones were photographed by a digital camera of 18 megapixels, which were then imported to a computer to determine various parameters using ScopyDoc 8.0.0.22 version software, after proper calibration and at 1× magnification. Results: When the round window niche is placed posteriorly and inferiorly, the distance between round window and vertical facial nerve decreases, whereas that with horizontal facial nerve increases. In such cases, the distance between oval window and round window also increases. Maximum height of the round window in our study ranged from 0.51-1.27 mm (mean of 0.69 ± 0.25 mm). Maximum width of round window ranged from 0.51 to 2.04 mm (mean of 1.16 ± 0.47 mm). Average minimum distance between round window and carotid canal was 3.71 ± 0.88 mm (range of 2.79-5.34 mm) and that between round window and jugular fossa was 2.47 ± 0.9 mm (range of 1.24-4.3 mm). Conclusion: The distances from the round window to the oval window and facial nerve are important parameters in identifying a difficult round window niche. Modification of the electrode may be a better option than drilling off the round window margins for insertion of cochlear implant electrodes.


Resumo Introdução: Vários aspectos da anatomia da janela redonda e da anatomia da caixa timpânica posterior são relevantes, devido a suas implicações no desenho dos eletrodos para o implante coclear e na visibilidade da janela redonda através do recesso facial. Informações prévias sobre possíveis variações anatômicas da janela redonda e suas relações com as estruturas neurovasculares adjacentes podem ajudar a reduzir as complicações dessa cirurgia. Objetivo: O presente estudo foi realizado para avaliar as diversas variações da anatomia da janela redonda e sua relação com as estruturas adjacentes, o que pode ser relevante para a cirurgia de implante coclear. Método: Trinta e cinco ossos temporais normais de cadáveres humanos frescos foram dissecados para avaliação da anatomia da janela redonda e sua relação com o nervo facial, canal carotídeo, fossa jugular e outras estruturas da caixa timpânica posterior. Os ossos dissecados foram fotografados com uma câmera digital de 18 megapixels e as imagens importadas para um computador para determinar diversos parâmetros, utilizando-se o software ScopyDoc versão 8.0.0.22, após a calibração adequada e com ampliação de 1×. Resultados: Quando o nicho da janela redonda se encontra posicionado posteriormente e inferiormente, a distância entre a janela redonda e o nervo facial vertical diminui, enquanto aquela com o nervo facial horizontal aumenta. Em tais casos, a distância entre a janela oval e a janela redonda também aumenta. A altura máxima da janela redonda em nosso estudo variou de 0,51 a 1,27 mm (média de 0,69 ± 0,25 mm). A largura máxima da janela redonda variou de 0,51 a 2,04 mm (média de 1,16 a 0,47 mm). A distância mínima média entre a janela redonda e o canal carotídeo foi de 3,71 ± 0,88 mm (variação de 2,79 a 5,34 mm) e entre a janela redonda e a fossa jugular, em nosso estudo, foi de 2,47 ± 0,9 mm (variação de 1,24 ± 4,3 mm). Conclusão: A distância da janela redonda a partir da janela oval e do nervo facial são parâmetros importantes para a identificação do difícil nicho da janela redonda. A modificação do desenho do eletrodo pode ser uma opção melhor do que o broqueamento das margens da janela redonda para a inserção dos eletrodos no implante coclear.


Assuntos
Humanos , Janela da Cóclea/anatomia & histologia , Osso Temporal/anatomia & histologia , Membrana Timpânica/anatomia & histologia , Janela do Vestíbulo/anatomia & histologia , Cadáver , Artéria Carótida Interna/anatomia & histologia , Implante Coclear , Dissecação , Nervo Facial/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA