Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.104
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
N Engl J Med ; 388(16): 1501-1511, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37075142

RESUMO

BACKGROUND: The use of cerebral oximetry monitoring in the care of extremely preterm infants is increasing. However, evidence that its use improves clinical outcomes is lacking. METHODS: In this randomized, phase 3 trial conducted at 70 sites in 17 countries, we assigned extremely preterm infants (gestational age, <28 weeks), within 6 hours after birth, to receive treatment guided by cerebral oximetry monitoring for the first 72 hours after birth or to receive usual care. The primary outcome was a composite of death or severe brain injury on cerebral ultrasonography at 36 weeks' postmenstrual age. Serious adverse events that were assessed were death, severe brain injury, bronchopulmonary dysplasia, retinopathy of prematurity, necrotizing enterocolitis, and late-onset sepsis. RESULTS: A total of 1601 infants underwent randomization and 1579 (98.6%) were evaluated for the primary outcome. At 36 weeks' postmenstrual age, death or severe brain injury had occurred in 272 of 772 infants (35.2%) in the cerebral oximetry group, as compared with 274 of 807 infants (34.0%) in the usual-care group (relative risk with cerebral oximetry, 1.03; 95% confidence interval, 0.90 to 1.18; P = 0.64). The incidence of serious adverse events did not differ between the two groups. CONCLUSIONS: In extremely preterm infants, treatment guided by cerebral oximetry monitoring for the first 72 hours after birth was not associated with a lower incidence of death or severe brain injury at 36 weeks' postmenstrual age than usual care. (Funded by the Elsass Foundation and others; SafeBoosC-III ClinicalTrials.gov number, NCT03770741.).


Assuntos
Lactente Extremamente Prematuro , Doenças do Prematuro , Oximetria , Humanos , Lactente , Recém-Nascido , Lesões Encefálicas/diagnóstico por imagem , Lesões Encefálicas/etiologia , Displasia Broncopulmonar/etiologia , Circulação Cerebrovascular , Doenças do Prematuro/diagnóstico , Doenças do Prematuro/mortalidade , Doenças do Prematuro/terapia , Oximetria/métodos , Cérebro , Ultrassonografia , Retinopatia da Prematuridade/etiologia , Enterocolite Necrosante/etiologia , Sepse Neonatal/etiologia
2.
N Engl J Med ; 387(19): 1759-1769, 2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36278971

RESUMO

BACKGROUND: Invasive mechanical ventilation in critically ill adults involves adjusting the fraction of inspired oxygen to maintain arterial oxygen saturation. The oxygen-saturation target that will optimize clinical outcomes in this patient population remains unknown. METHODS: In a pragmatic, cluster-randomized, cluster-crossover trial conducted in the emergency department and medical intensive care unit at an academic center, we assigned adults who were receiving mechanical ventilation to a lower target for oxygen saturation as measured by pulse oximetry (Spo2) (90%; goal range, 88 to 92%), an intermediate target (94%; goal range, 92 to 96%), or a higher target (98%; goal range, 96 to 100%). The primary outcome was the number of days alive and free of mechanical ventilation (ventilator-free days) through day 28. The secondary outcome was death by day 28, with data censored at hospital discharge. RESULTS: A total of 2541 patients were included in the primary analysis. The median number of ventilator-free days was 20 (interquartile range, 0 to 25) in the lower-target group, 21 (interquartile range, 0 to 25) in the intermediate-target group, and 21 (interquartile range, 0 to 26) in the higher-target group (P = 0.81). In-hospital death by day 28 occurred in 281 of the 808 patients (34.8%) in the lower-target group, 292 of the 859 patients (34.0%) in the intermediate-target group, and 290 of the 874 patients (33.2%) in the higher-target group. The incidences of cardiac arrest, arrhythmia, myocardial infarction, stroke, and pneumothorax were similar in the three groups. CONCLUSIONS: Among critically ill adults receiving invasive mechanical ventilation, the number of ventilator-free days did not differ among groups in which a lower, intermediate, or higher Spo2 target was used. (Supported by the National Heart, Lung, and Blood Institute and others; PILOT ClinicalTrials.gov number, NCT03537937.).


Assuntos
Estado Terminal , Oxigênio , Respiração Artificial , Adulto , Humanos , Estado Terminal/terapia , Mortalidade Hospitalar , Unidades de Terapia Intensiva , Oxigênio/administração & dosagem , Oxigênio/sangue , Oxigênio/uso terapêutico , Respiração Artificial/métodos , Cuidados Críticos/métodos , Estudos Cross-Over , Serviço Hospitalar de Emergência , Centros Médicos Acadêmicos , Oximetria
3.
Am J Respir Crit Care Med ; 209(1): 37-47, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37487152

RESUMO

Background: Since publication of the 2012 Berlin definition of acute respiratory distress syndrome (ARDS), several developments have supported the need for an expansion of the definition, including the use of high-flow nasal oxygen, the expansion of the use of pulse oximetry in place of arterial blood gases, the use of ultrasound for chest imaging, and the need for applicability in resource-limited settings. Methods: A consensus conference of 32 critical care ARDS experts was convened, had six virtual meetings (June 2021 to March 2022), and subsequently obtained input from members of several critical care societies. The goal was to develop a definition that would 1) identify patients with the currently accepted conceptual framework for ARDS, 2) facilitate rapid ARDS diagnosis for clinical care and research, 3) be applicable in resource-limited settings, 4) be useful for testing specific therapies, and 5) be practical for communication to patients and caregivers. Results: The committee made four main recommendations: 1) include high-flow nasal oxygen with a minimum flow rate of ⩾30 L/min; 2) use PaO2:FiO2 ⩽ 300 mm Hg or oxygen saturation as measured by pulse oximetry SpO2:FiO2 ⩽ 315 (if oxygen saturation as measured by pulse oximetry is ⩽97%) to identify hypoxemia; 3) retain bilateral opacities for imaging criteria but add ultrasound as an imaging modality, especially in resource-limited areas; and 4) in resource-limited settings, do not require positive end-expiratory pressure, oxygen flow rate, or specific respiratory support devices. Conclusions: We propose a new global definition of ARDS that builds on the Berlin definition. The recommendations also identify areas for future research, including the need for prospective assessments of the feasibility, reliability, and prognostic validity of the proposed global definition.


Assuntos
Síndrome do Desconforto Respiratório , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/terapia , Oximetria , Oxigênio
4.
Br J Haematol ; 204(4): 1495-1499, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311363

RESUMO

The symptoms and sequelae of sickle cell anaemia (SCA) are caused by the polymerization of deoxygenated sickle haemoglobin, and people with SCA may be uniquely susceptible to adverse outcomes from hypoxia and haemoglobin desaturation. We examined by oximetry adults (aged 18-45 years) with SCA presenting symptoms indicative of polysomnography, at a single institution, irrespective of treatment, for nocturnal hypoxaemia. Clinical labs and blood for in vitro assessments were taken upon enrolment and after 8-12 weeks of oxygen therapy or observation. Of 21 screened participants, nine (43%) had sufficient nocturnal hypoxaemia to warrant oxygen therapy (≥5 min at SpO2 ≤ 88%). Time spent at SpO2 ≤ 88% associated with age (p = 0.0092), annual hospitalizations (p = 0.0018) and anaemia (p = 0.0139), as well as plasma levels of TNFα (p = 0.0019) and IL-4 (p = 0.0147). Longitudinal analysis showed that WBC significantly decreased during the follow-up period in hypoxic individuals but not in non-hypoxic individuals (p = 0.0361 and p = 0.6969 respectively). Plasma levels of CCL2 and IL-1ra tended to increase, while levels of red blood cell reactive oxygen species tended to decrease with oxygen therapy. Overall, nocturnal hypoxaemia was common in this pilot study population and associated with plausible clinical comorbidities; oxygen therapy may decrease inflammation and oxidative damage in hypoxic individuals.


Assuntos
Anemia Falciforme , Hipóxia , Adulto , Humanos , Hipóxia/etiologia , Hipóxia/diagnóstico , Anemia Falciforme/complicações , Anemia Falciforme/terapia , Oximetria , Hemoglobinas/análise , Oxigênio
5.
Eur Respir J ; 64(1)2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38782468

RESUMO

BACKGROUND: The direct Fick principle is the standard for calculating cardiac output (CO) to detect CO-dependent conditions like exercise pulmonary hypertension (ePH). Fick COarterial incorporates arterial haemoglobin (Hba) and oxygen saturation (S aO2 ) with oxygen consumption from exercise testing, while Fick COnon-arterial substitutes mixed venous haemoglobin (Hbmv) and peripheral oxygen saturation (S pO2 ) in the absence of an arterial line. The decision to employ an arterial catheter for exercise testing varies, and discrepancies in oxygen saturation and haemoglobin between arterial and non-arterial methods may lead to differences in Fick CO, potentially affecting ePH classification. METHODS: We performed a retrospective analysis of 296 consecutive invasive cardiopulmonary exercise testing (iCPET) studies comparing oxygen saturation from pulse oximetry (S pO2 ) and radial arterial (S aO2 ), Hba and Hbmv, and CO calculated with arterial (COarterial) and non-arterial (COnon-arterial) values. We assessed the risk of misclassification of pre- and post-capillary ePH and data loss due to inaccurate S pO2 . RESULTS: When considering all stages from rest to peak exercise, Hba and Hbmv demonstrated high correlation, while S pO2 and S aO2 as well as COarterial and COnon-arterial demonstrated low correlation. Data loss was significantly higher across all stages of exercise for S pO2 (n=346/1926 (18%)) compared to S aO2 (n=17/1923 (0.88%)). We found that pre- and post-capillary ePH were misclassified as COnon-arterial data (n=7/41 (17.1%) and n=2/23 (8.7%), respectively). Patients with scleroderma and/or Raynaud's (n=11/33 (33.3%)) and black patients (n=6/19 (31.6%)) had more S pO2 data loss. CONCLUSION: Reliance upon S pO2 during invasive exercise testing results in the misclassification of pre- and post-capillary ePH, and unmeasurable S pO2 for black, scleroderma and Raynaud's patients can preclude accurate exercise calculations, thus limiting the diagnostic and prognostic value of invasive exercise testing without an arterial line.


Assuntos
Débito Cardíaco , Teste de Esforço , Exercício Físico , Hipertensão Pulmonar , Oximetria , Doença de Raynaud , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Hipertensão Pulmonar/fisiopatologia , Doença de Raynaud/diagnóstico , Adulto , Escleroderma Sistêmico/fisiopatologia , Idoso , Saturação de Oxigênio , Consumo de Oxigênio , Hemoglobinas/análise , Hemoglobinas/metabolismo
6.
Crit Care Med ; 52(5): 775-785, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180092

RESUMO

OBJECTIVES: To determine if near-infrared spectroscopy measuring cerebral regional oxygen saturation (crS o2 ) during cardiopulmonary resuscitation is associated with return of spontaneous circulation (ROSC) and survival to hospital discharge (SHD) in children. DESIGN: Multicenter, observational study. SETTING: Three hospitals in the pediatric Resuscitation Quality (pediRES-Q) collaborative from 2015 to 2022. PATIENTS: Children younger than 18 years, gestational age 37 weeks old or older with in-hospital cardiac arrest (IHCA) receiving cardiopulmonary resuscitation greater than or equal to 1 minute and intra-arrest crS o2 monitoring. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Primary outcome was ROSC greater than or equal to 20 minutes without extracorporeal membrane oxygenation. Secondary outcomes included SHD and favorable neurologic outcome (FNO) (Pediatric Cerebral Performance Category 1-2 or no change from prearrest). Among 3212 IHCA events (index and nonindex), 123 met inclusion criteria in 93 patients. Median age was 0.3 years (0.1-1.4 yr) and 31% (38/123) of the cardiopulmonary resuscitation events occurred in patients with cyanotic heart disease. Median cardiopulmonary resuscitation duration was 8 minutes (3-28 min) and ROSC was achieved in 65% (80/123). For index events, SHD was achieved in 59% (54/91) and FNO in 41% (37/91). We determined the association of median intra-arrest crS o2 and percent of crS o2 values above a priori thresholds during the: 1) entire cardiopulmonary resuscitation event, 2) first 5 minutes, and 3) last 5 minutes with ROSC, SHD, and FNO. Higher crS o2 for the entire cardiopulmonary resuscitation event, first 5 minutes, and last 5 minutes were associated with higher likelihood of ROSC, SHD, and FNO. In multivariable analysis of the infant group (age < 1 yr), higher crS o2 was associated with ROSC (odds ratio [OR], 1.06; 95% CI, 1.03-1.10), SHD (OR, 1.04; 95% CI, 1.01-1.07), and FNO (OR, 1.05; 95% CI, 1.02-1.08) after adjusting for presence of cyanotic heart disease. CONCLUSIONS: Higher crS o2 during pediatric IHCA was associated with increased rate of ROSC, SHD, and FNO. Intra-arrest crS o2 may have a role as a real-time, noninvasive predictor of ROSC.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Humanos , Lactente , Reanimação Cardiopulmonar/métodos , Circulação Cerebrovascular , Parada Cardíaca/terapia , Hospitais Pediátricos , Oximetria
7.
Magn Reson Med ; 92(1): 430-439, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38411265

RESUMO

PURPOSE: Electron spin resonance (ESR) is used to measure oxygen partial pressure (pO2) in biological media with many clinical applications. Traditional clinical ESR involves large magnets that encompass the subject of measurement. However, certain applications might benefit from a scanner operating within local static magnetic fields. Our group recently developed such a compact scanner for transcutaneous (surface) pO2 measurements of skin tissue. Here we extend this capability to subsurface (subcutaneous) pO2 measurements and verify it using an artificial tissue emulating (ATE) phantom. METHODS: We introduce a new scanner, tailored for subcutaneous measurements up to 2 mm beneath the skin's surface. This scanner captures pulsed ESR signals from embedded approximate 1-mm oxygen-sensing solid paramagnetic implant, OxyChip. The scanner features a static magnetic field source, producing a uniform region outside its surface, and a compact microwave resonator, for exciting and receiving ESR signals. RESULTS: ESR readings derived from an OxyChip, positioned approximately 1.5 mm from the scanner's surface, embedded in ATE phantom, exhibited a linear relation of 1/T2 versus pO2 for pO2 levels at 0, 7.6, 30, and 160 mmHg, with relative reading accuracy of about 10%. CONCLUSION: The compact ESR scanner can report pO2 data in ATE phantom from an external position relative to the scanner. Implementing this scanner in preclinical and clinical applications for subcutaneous pO2 measurements is a feasible next phase for this development. This innovative design also has the potential to operate in conjunction with artificial skin graft for wound healing, combining therapeutic and pO2 diagnostic features.


Assuntos
Oximetria , Oxigênio , Imagens de Fantasmas , Espectroscopia de Ressonância de Spin Eletrônica , Oximetria/métodos , Humanos , Desenho de Equipamento , Pele/diagnóstico por imagem
8.
Magn Reson Med ; 91(1): 413-423, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37676121

RESUMO

PURPOSE: In this study, we compared two triarylmethyl (TAM) spin probes, Ox071 and Ox063 for their efficacy in measuring tissue oxygen levels under hypoxic and normoxic conditions by R2 *-based EPR oximetry. METHODS: The R2 * dependencies on the spin probe concentration and oxygen level were calibrated using deoxygenated 1, 2, 5, and 10 mM standard solutions and 2 mM solutions saturated at 0%, 2%, 5%, 10%, and 21% of oxygen. For the hypoxic model, in vivo imaging of a MIA PaCa-2 tumor implanted in the hind leg of a mouse was performed on successive days by R2 *-based EPR oximetry using either Ox071 or Ox063. For the normoxic model, renal imaging of healthy athymic mice was performed using both spin probes. The 3D images were reconstructed by single point imaging and multi-gradient technique was used to determine R2 * maps. RESULTS: The signal intensities of Ox071 were approximately three times greater than that of Ox063 in the entire partial pressure of oxygen (pO2 ) range investigated. The histograms of the tumor pO2 images were skewed for both spin probes, and Ox071 showed more frequency counts at pO2 > 32 mm Hg. In the normoxic kidney model, there was a clear delineation between the high pO2 cortex and the low pO2 medulla regions. The histogram of high-resolution kidney oximetry image using Ox071 was nearly symmetrical and frequency counts were seen up to 55 mm Hg, which were missed in Ox063 imaging. CONCLUSION: As an oximetric probe, Ox071 has clear advantages over Ox063 in terms of sensitivity and the pO2 dynamic range.


Assuntos
Neoplasias , Oximetria , Camundongos , Animais , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Oximetria/métodos , Oxigênio , Imageamento Tridimensional
9.
Magn Reson Med ; 91(5): 2057-2073, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38146669

RESUMO

PURPOSE: Renal metabolic rate of oxygen (rMRO2 ) is a potentially important biomarker of kidney function. The key parameters for rMRO2 quantification include blood flow rate (BFR) and venous oxygen saturation (SvO2 ) in a draining vessel. Previous approaches to quantify renal metabolism have focused on the single organ. Here, both kidneys are considered as one unit to quantify bilateral rMRO2 . A pulse sequence to facilitate bilateral rMRO2 quantification is introduced. METHODS: To quantify bilateral rMRO2 , measurements of BFR and SvO2 are made along the inferior vena cava (IVC) at suprarenal and infrarenal locations. From the continuity equation, these four parameters can be related to derive an expression for bilateral rMRO2 . The recently reported K-MOTIVE pulse sequence was implemented at four locations: left kidney, right kidney, suprarenal IVC, and infrarenal IVC. A dual-band variant of K-MOTIVE (db-K-MOTIVE) was developed by incorporating simultaneous-multi-slice imaging principles. The sequence simultaneously measures BFR and SvO2 at suprarenal and infrarenal locations in a single pass of 21 s, yielding bilateral rMRO2 . RESULTS: SvO2 and BFR are higher in suprarenal versus infrarenal IVC, and the renal veins are highly oxygenated (SvO2 >90%). Bilateral rMRO2 quantified in 10 healthy subjects (8 M, 30 ± 8 y) was found to be 291 ± 247 and 349 ± 300 (µmolO2 /min)/100 g, derived from K-MOTIVE and db-K-MOTIVE, respectively. In comparison, total rMRO2 from combining left and right was 329 ± 273 (µmolO2 /min)/100 g. CONCLUSION: The present work demonstrates that bilateral rMRO2 quantification is feasible with fair reproducibility and physiological plausibility. The indirect method is a promising approach to compute bilateral rMRO2 when individual rMRO2 quantification is difficult.


Assuntos
Oximetria , Oxigênio , Humanos , Reprodutibilidade dos Testes , Oximetria/métodos , Veia Cava Inferior/diagnóstico por imagem , Rim/diagnóstico por imagem , Rim/metabolismo
10.
J Pediatr ; 271: 114043, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38561049

RESUMO

OBJECTIVE: The objective of this study was to predict extubation readiness in preterm infants using machine learning analysis of bedside pulse oximeter and ventilator data. STUDY DESIGN: This is an observational study with prospective recordings of oxygen saturation (SpO2) and ventilator data from infants <30 weeks of gestation age. Research pulse oximeters collected SpO2 (1 Hz sampling rate) to quantify intermittent hypoxemia (IH). Continuous ventilator metrics were collected (4-5-minute sampling) from bedside ventilators. Data modeling was completed using unbiased machine learning algorithms. Three model sets were created using the following data source combinations: (1) IH and ventilator (IH + SIMV), (2) IH, and (3) ventilator (SIMV). Infants were also analyzed separated by postnatal age (infants <2 or ≥2 weeks of age). Models were compared by area under the receiver operating characteristic curve (AUC). RESULTS: A total of 110 extubation events from 110 preterm infants were analyzed. Infants had a median gestation age and birth weight of 26 weeks and 825 g, respectively. Of the 3 models presented, the IH + SIMV model achieved the highest AUC of 0.77 for all infants. Separating infants by postnatal age increased accuracy further achieving AUC of 0.94 for <2 weeks of age group and AUC of 0.83 for ≥2 weeks group. CONCLUSIONS: Machine learning analysis has the potential to enhance prediction accuracy of extubation readiness in preterm infants while utilizing readily available data streams from bedside pulse oximeters and ventilators.


Assuntos
Extubação , Recém-Nascido Prematuro , Aprendizado de Máquina , Oximetria , Humanos , Recém-Nascido , Estudos Prospectivos , Masculino , Feminino , Oximetria/métodos , Hipóxia/diagnóstico , Saturação de Oxigênio , Desmame do Respirador/métodos , Curva ROC , Idade Gestacional
11.
J Pediatr ; 273: 114132, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38823628

RESUMO

OBJECTIVE: To define percentile charts for arterial oxygen saturation (SpO2), heart rate (HR), and cerebral oxygen saturation (crSO2) during the first 15 minutes after birth in neonates born very or extremely preterm and with favorable outcome. STUDY DESIGN: We conducted a secondary-outcome analysis of neonates born preterm included in the Cerebral regional tissue Oxygen Saturation to Guide Oxygen Delivery in preterm neonates during immediate transition after birth III (COSGOD III) trial with visible cerebral oximetry measurements and with favorable outcome, defined as survival without cerebral injuries until term age. We excluded infants with inflammatory morbidities within the first week after birth. SpO2 was obtained by pulse oximetry, and electrocardiogram or pulse oximetry were used for measurement of HR. crSO2 was assessed with near-infrared spectroscopy. Measurements were performed during the first 15 minutes after birth. Percentile charts (10th to 90th centile) were defined for each minute. RESULTS: A total of 207 neonates born preterm with a gestational age of 29.7 (23.9-31.9) weeks and a birth weight of 1200 (378-2320) g were eligible for analyses. The 10th percentile of SpO2 at minute 2, 5, 10, and 15 was 32%, 52%, 83%, and 85%, respectively. The 10th percentile of HR at minute 2, 5, 10, and 15 was 70, 109, 126, and 134 beats/min, respectively. The 10th percentile of crSO2 at minute 2, 5, 20, and 15 was 15%, 27%, 59%, and 63%, respectively. CONCLUSIONS: This study provides new centile charts for SpO2, HR, and crSO2 for neonates born extremely or very preterm with favorable outcome. Implementing these centiles in guiding interventions during the stabilization process after birth might help to more accurately target oxygenation during postnatal transition period.


Assuntos
Frequência Cardíaca , Lactente Extremamente Prematuro , Oximetria , Saturação de Oxigênio , Humanos , Recém-Nascido , Frequência Cardíaca/fisiologia , Saturação de Oxigênio/fisiologia , Feminino , Masculino , Oximetria/métodos , Valores de Referência , Espectroscopia de Luz Próxima ao Infravermelho , Recém-Nascido Prematuro , Oxigênio/metabolismo , Oxigênio/sangue , Encéfalo/metabolismo , Idade Gestacional
12.
Ann Neurol ; 93(1): 205-212, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36251404

RESUMO

Risk of sudden death in multiple system atrophy (MSA) is greatest during sleep with unknown mechanisms. We compared nocturnal pulse event frequency in 46 MSA patients and age-/sex-matched controls undergoing overnight pulse oximetry. Nocturnal oxyhemoglobin desaturation indices and pulse event indices (PEIs) were recorded, and relationships between pulse oximetry variables and survival were analyzed. MSA patients had lower PEI (3.1 ± 5.3 vs. 12.8 ± 10.8, p < 0.001) despite greater hypoxic burden and similar frequency of respiratory events. Nocturnal pulse events were not associated with severity of daytime autonomic failure. Two MSA patients had suspected sudden death, both with severely reduced PEI. MSA patients have fewer nocturnal pulse events compared with controls, despite similar respiratory event frequency, suggesting abnormal cardiac responses to sleep-disordered breathing. Whether this contributes to sudden death in MSA requires further study. ANN NEUROL 2023;93:205-212.


Assuntos
Atrofia de Múltiplos Sistemas , Síndromes da Apneia do Sono , Humanos , Sono/fisiologia , Síndromes da Apneia do Sono/complicações , Oximetria , Morte Súbita
13.
Cardiovasc Diabetol ; 23(1): 195, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844945

RESUMO

BACKGROUND: Micro- and macrovascular diseases are common in patients with type 2 diabetes mellitus (T2D) and may be partly caused by nocturnal hypoxemia. The study aimed to characterize the composition of nocturnal hypoxemic burden and to assess its association with micro- and macrovascular disease in patients with T2D. METHODS: This cross-sectional analysis includes overnight oximetry from 1247 patients with T2D enrolled in the DIACORE (DIAbetes COhoRtE) study. Night-time spent below a peripheral oxygen saturation of 90% (T90) as well as T90 associated with non-specific drifts in oxygen saturation (T90non - specific), T90 associated with acute oxygen desaturation (T90desaturation) and desaturation depths were assessed. Binary logistic regression analyses adjusted for known risk factors (age, sex, smoking status, waist-hip ratio, duration of T2D, HbA1c, pulse pressure, low-density lipoprotein, use of statins, and use of renin-angiotensin-aldosterone system inhibitors) were used to assess the associations of such parameters of hypoxemic burden with chronic kidney disease (CKD) as a manifestation of microvascular disease and a composite of cardiovascular diseases (CVD) reflecting macrovascular disease. RESULTS: Patients with long T90 were significantly more often affected by CKD and CVD than patients with a lower hypoxemic burden (CKD 38% vs. 28%, p < 0.001; CVD 30% vs. 21%, p < 0.001). Continuous T90desaturation and desaturation depth were associated with CKD (adjusted OR 1.01 per unit, 95% CI [1.00; 1.01], p = 0.008 and OR 1.30, 95% CI [1.06; 1.61], p = 0.013, respectively) independently of other known risk factors for CKD. For CVD there was a thresholdeffect, and only severly and very severly increased T90non-specific was associated with CVD ([Q3;Q4] versus [Q1;Q2], adjusted OR 1.51, 95% CI [1.12; 2.05], p = 0.008) independently of other known risk factors for CVD. CONCLUSION: While hypoxemic burden due to oxygen desaturations and the magnitude of desaturation depth were significantly associated with CKD, only severe hypoxemic burden due to non-specific drifts was associated with CVD. Specific types of hypoxemic burden may be related to micro- and macrovascular disease.


Assuntos
Diabetes Mellitus Tipo 2 , Hipóxia , Humanos , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Idoso , Hipóxia/diagnóstico , Hipóxia/sangue , Hipóxia/epidemiologia , Hipóxia/fisiopatologia , Fatores de Risco , Oximetria , Ritmo Circadiano , Saturação de Oxigênio , Angiopatias Diabéticas/diagnóstico , Angiopatias Diabéticas/epidemiologia , Angiopatias Diabéticas/fisiopatologia , Angiopatias Diabéticas/sangue , Fatores de Tempo , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/sangue
14.
Respir Res ; 25(1): 162, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622608

RESUMO

BACKGROUND: Remote monitoring of patient-recorded spirometry and pulse oximetry offers an alternative approach to traditional hospital-based monitoring of interstitial lung disease (ILD). Remote spirometry has been observed to reasonably reflect clinic spirometry in participants with ILD but remote monitoring has not been widely incorporated into clinical practice. We assessed the feasibility of remotely monitoring patients within a clinical ILD service. METHODS: Prospective, single-arm, open-label observational multi-centre study (NCT04850521). Inclusion criteria included ILD diagnosis, age ≥ 18 years, FVC ≥ 50% predicted. 60 participants were asked to record a single spirometry and oximetry measurement at least once daily, monitored weekly by their local clinical team. Feasibility was defined as ≥ 68% of participants with ≥ 70% adherence to study measurements and recording measurements ≥ 3 times/week throughout. RESULTS: A total of 60 participants were included in the analysis. 42/60 (70%) were male; mean age 67.8 years (± 11.2); 34/60 (56.7%) had idiopathic pulmonary fibrosis (IPF), Median ILD-GAP score was 3 (IQR 1-4.75). Spirometry adherence was achieved for ≥ 70% of study days in 46/60 participants (77%) and pulse oximetry adherence in 50/60 participants (83%). Recording ≥ 3 times/week every week was provided for spirometry in 41/60 participants (68%) and pulse oximetry in 43/60 participants (72%). Mean difference between recent clinic and baseline home spirometry was 0.31 L (± 0.72). 85.7% (IQR 63.9-92.6%) home spirometry attempts/patient were acceptable or usable according to ERS/ATS spirometry criteria. Positive correlation was observed between ILD-GAP score and adherence to spirometry and oximetry (rho 0.24 and 0.38 respectively). Adherence of weekly monitoring by clinical teams was 80.95% (IQR 64.19-95.79). All participants who responded to an experience questionnaire (n = 33) found remote measurements easy to perform and 75% wished to continue monitoring their spirometry at the conclusion of the study. CONCLUSION: Feasibility of remote monitoring within an ILD clinical service was demonstrated over 3 months for both daily home spirometry and pulse oximetry of patients. Remote monitoring may be more acceptable to participants who are older or have more advanced disease. TRIAL REGISTRATION: clinicaltrials.gov NCT04850521 registered 20th April 2021.


Assuntos
Doenças Pulmonares Intersticiais , Humanos , Masculino , Idoso , Adolescente , Feminino , Estudos Prospectivos , Estudos de Viabilidade , Capacidade Vital , Doenças Pulmonares Intersticiais/diagnóstico , Espirometria , Oximetria
15.
J Gen Intern Med ; 39(13): 2543-2553, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39020232

RESUMO

BACKGROUND: There is growing concern that pulse oximeters are routinely less accurate in hospitalized patients with darker skin pigmentation, in turn increasing risk of undetected (occult) hypoxemia and adverse clinical outcomes. The aim of this systematic review and meta-analysis was to synthesize evidence on racial and ethnic disparities in occult hypoxemia prevalence and clinical impacts of undetected hypoxemia. METHODS: Ovid MEDLINE, Embase, and CINAHL databases were searched for relevant articles published through January 2024. Eligible studies must have been conducted among adults in inpatient or outpatient settings and report occult hypoxemia prevalence stratified by patient race or ethnicity, or clinical outcomes stratified by patient race or ethnicity and occult hypoxemia status. Screening for inclusion was conducted independently by two investigators. Data extraction and risk of bias assessment were conducted by one investigator then checked by a second. Outcome data were synthesized using random-effects meta-analyses. RESULTS: Fifteen primary studies met eligibility criteria and reported occult hypoxemia prevalence in 732,505 paired oximetry measurements from 207,464 hospitalized patients. Compared with White patients, occult hypoxemia is likely more common among Black patients (pooled prevalence ratio = 1.67, 95% CI 1.47 to 1.90) and among patients identifying as Asian, Latinx, Indigenous, multiracial, or other race or ethnicity (pooled prevalence ratio = 1.39, 95% CI 1.19 to 1.64). Findings from studies reporting clinical outcomes suggest that Black patients with undetected hypoxemia may experience poorer treatment delivery outcomes than White patients with undetected hypoxemia. No evidence was found from outpatient settings. DISCUSSION: This review and included primary studies rely on self-identified race or ethnicity, which may obscure variability in occult hypoxemia risk. Findings underscore that clinicians should be aware of the risk of occult hypoxemia in hospitalized patients with darker skin pigmentation. Moreover, oximetry data from included studies suggests that the accuracy of pulse oximeters could vary substantially from patient to patient and even within individual patients. TRIAL REGISTRATION: PROSPERO ( CRD42023402152 ).


Assuntos
Hospitalização , Hipóxia , Humanos , Etnicidade , Disparidades em Assistência à Saúde/etnologia , Hospitalização/estatística & dados numéricos , Hipóxia/etnologia , Hipóxia/epidemiologia , Hipóxia/diagnóstico , Hipóxia/etiologia , Oximetria , Prevalência , Grupos Raciais
16.
Exp Eye Res ; 243: 109882, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582182

RESUMO

Retinal oximetry could provide insights into the pathophysiology of optic nerve disease, including optic disc drusen (ODD). Vessel selection for oximetry analysis is based on morphological characteristics of arterioles and venules and supported by an overlay of estimated blood oxygen saturations. The purpose of this cross-sectional study was to determine the validity of this vessel selection procedure by comparing it with vessel selection supported by video fluorescein angiography (FA). The study included 36 eyes of 36 patients with ODD who underwent retinal oximetry (Oxymap retinal oximeter T1) followed by FA (Heidelberg Spectralis). Two trained graders selected vessel segments in a pre-defined measurement area around the optic disc. One of these graders additionally performed the vessel segment selection with the support of FA images. When performed by the same grader, FA-supported and non-FA-supported vessel selection did not lead to significant differences in total vessel segment length, estimated oxygen saturations or vessel diameters (all p > 0.05). Inter-grader differences were found for arterial and venous segment lengths and arterial saturation (p < 0.05). A similar tendency was found for the arteriovenous saturation difference (p = 0.10). In conclusion, identifying vessel segments for retinal oximetry analysis based on vessel morphology and supported by a color-coded saturation overlay appears to be a valid method without the need for invasive angiography. A numerically small inter-grader variation may influence oximetry results. Further studies of retinal oximetry in ODD are warranted.


Assuntos
Angiofluoresceinografia , Drusas do Disco Óptico , Oximetria , Vasos Retinianos , Humanos , Oximetria/métodos , Feminino , Masculino , Angiofluoresceinografia/métodos , Estudos Transversais , Pessoa de Meia-Idade , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiopatologia , Drusas do Disco Óptico/fisiopatologia , Drusas do Disco Óptico/diagnóstico , Adulto , Oxigênio/sangue , Reprodutibilidade dos Testes , Idoso , Saturação de Oxigênio/fisiologia , Disco Óptico/irrigação sanguínea
17.
Anesthesiology ; 140(2): 231-239, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37938036

RESUMO

BACKGROUND: Near-infrared spectroscopy (NIRS) has been utilized widely in anesthesia and intensive care to monitor regional cerebral oxygen saturation (rScO2). A normal oxygenation of extracerebral tissues may overlay and thereby mask cerebral desaturations, a phenomenon known as extracerebral contamination. The authors investigated the effect of a cessation of extracerebral tissue perfusion on rScO2 in patients with anoxic brains. METHODS: In a single-center, prospective, observational study, brain-dead adults undergoing organ donation were investigated. rScO2 was measured bifrontally using the INVOS 5100C/7100 as well as the ForeSight Elite system. To achieve an efficient conservation of organs and to prevent a redistribution of the perfusion fluid to other tissues, the aorta was clamped before organ perfusion. rScO2 was monitored until at least 40 min after aortic clamping. The primary outcome was the amount of extracerebral contamination as quantified by the absolute decrease in rScO2 after aortic clamping. Secondary outcomes were the absolute rScO2 values obtained before and after clamping. RESULTS: Twelve organ donors were included. Aortic clamping resulted in a significantly (P < 0.001) greater absolute decrease in rScO2 when comparing the INVOS (43.0 ± 9.5%) to the ForeSight (27.8 ± 7.1%) monitor. Before aortic clamping, near-normal rScO2 values were obtained by the INVOS (63.8 ± 6.2%) and the ForeSight monitor (67.7 ± 6.5%). The rScO2 significantly (P < 0.001) dropped to 20.8 ± 7.8% (INVOS) and 39.9 ± 8.1% (ForeSight) 30 min after clamping, i.e., a condition of a desaturation of both extracerebral and cerebral tissues. CONCLUSIONS: The abrupt end of extracerebral contamination, caused by aortic clamping, affected both NIRS monitors to a considerable extent. Both the INVOS and the ForeSight monitor were unable to detect severe cerebral hypoxia or anoxia under conditions of normal extracerebral oxygenation. While both NIRS monitors may guide measures to optimize arterial oxygen supply to the head, they should not be used with the intention to detect isolated cerebral desaturations.


Assuntos
Oximetria , Obtenção de Tecidos e Órgãos , Adulto , Humanos , Oximetria/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos Prospectivos , Encéfalo , Doadores de Tecidos , Oxigênio
18.
Pediatr Res ; 96(2): 486-493, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38503982

RESUMO

BACKGROUND: Unstable cerebral hemodynamics places preterm infants at high risk of brain injury. We adapted an innovative, fiber-free, wearable diffuse speckle contrast flow-oximetry (DSCFO) device for continuous monitoring of both cerebral blood flow (CBF) and oxygenation in neonatal piglets and preterm infants. METHODS: DSCFO uses two small laser diodes as focused-point and a tiny CMOS camera as a high-density two-dimensional detector to detect spontaneous spatial fluctuation of diffuse laser speckles for CBF measurement, and light intensity attenuations for cerebral oxygenation measurement. The DSCFO was first validated against the established diffuse correlation spectroscopy (DCS) in neonatal piglets and then utilized for continuous CBF and oxygenation monitoring in preterm infants during intermittent hypoxemia (IH) events. RESULTS: Significant correlations between the DSCFO and DCS measurements of CBF variations in neonatal piglets were observed. IH events induced fluctuations in CBF, cerebral oxygenation, and peripheral cardiorespiratory vitals in preterm infants. However, no consistent correlation patterns were observed among peripheral and cerebral monitoring parameters. CONCLUSIONS: This pilot study demonstrated the feasibility of DSCFO technology to serve as a low-cost wearable sensor for continuous monitoring of multiple cerebral hemodynamic parameters. The results suggested the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations. IMPACT: The innovative DSCFO technology may serve as a low-cost wearable sensor for continuous bedside monitoring of multiple cerebral hemodynamic parameters in neonatal intensive care units. Concurrent DSCFO and DCS measurements of CBF variations in neonatal piglet models generated consistent results. No consistent correlation patterns were observed among peripheral and cerebral monitoring parameters in preterm neonates, suggesting the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations during IH events. Integrating and correlating multiple cerebral functional parameters with clinical outcomes may identify biomarkers for prediction and management of IH associated brain injury.


Assuntos
Animais Recém-Nascidos , Circulação Cerebrovascular , Oximetria , Oxigênio , Dispositivos Eletrônicos Vestíveis , Animais , Recém-Nascido , Humanos , Suínos , Oximetria/instrumentação , Oximetria/métodos , Oxigênio/metabolismo , Oxigênio/sangue , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Projetos Piloto , Recém-Nascido Prematuro , Hemodinâmica , Hipóxia , Feminino , Masculino , Encéfalo/irrigação sanguínea
19.
Pediatr Res ; 96(3): 766-772, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38600299

RESUMO

BACKGROUND: Intermittent hypoxemia (IH) may influence retinopathy of prematurity (ROP) development in preterm infants, however, previous studies had mixed results. This study tests the hypothesis that increased IH is associated with Type 1 ROP; a stage beyond which treatment is indicated. METHODS: IH was quantified by continuously monitoring oxygen saturation (SpO2) using high-resolution pulse oximeters during the first 10 weeks of life. Statistical analyses assessed the relationship and predictive ability of weekly and cumulative IH for Type 1 ROP development. RESULTS: Most analyses showed no association between IH and Type 1 ROP adjusting for gestational age (GA) and birth weight (BW). However, cumulative IH of longer duration during weeks 5-10, 6-10, and 7-10 were significantly associated with Type 1 ROP adjusting for GA and BW, e.g., the adjusted odds ratio of Type 1 ROP was 2.01 (p = 0.03) for every 3.8 seconds increase in IH duration from week 6-10. IH did not provide statistically significant added predictive ability above GA and BW. CONCLUSIONS: For most analyses there was no significant association between IH and Type 1 ROP adjusting for GA and BW. However, infants with longer IH duration during the second month of life had higher risk for Type 1 ROP. IMPACT: The relationship and predictive ability of intermittent hypoxemia (IH) on retinopathy of prematurity (ROP) is controversial. This study shows no significant association between IH events and Type 1 ROP after adjusting for gestational age (GA) and birth weight (BW), except for cumulative IH of longer duration in the second month of life. In this cohort, IH does not provide a statistically significant improvement in ROP prediction over GA and BW. This study is the first to assess the cumulative impact of IH measures on Type 1 ROP. Interventions for reducing IH duration during critical postnatal periods may improve ROP outcomes.


Assuntos
Peso ao Nascer , Idade Gestacional , Hipóxia , Recém-Nascido Prematuro , Retinopatia da Prematuridade , Humanos , Retinopatia da Prematuridade/etiologia , Recém-Nascido , Masculino , Feminino , Oximetria , Fatores de Risco , Saturação de Oxigênio , Razão de Chances
20.
Pediatr Res ; 96(2): 427-435, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38365870

RESUMO

BACKGROUND: Effective seizure detection is important however, clinical signs of seizure activity may be subtle in neonates. This study aimed to systematically investigate SpO2 and respiratory pattern changes associated with EEG seizures in term-born neonates. METHOD: An observational study in term neonates at risk of seizures admitted to a single tertiary level neonatal intensive care unit. Synchronised high-resolution physiological data (ECG, pulse oximetry, respiration) and EEG/amplitude-integrated EEG (aEEG) monitoring were recorded. Sections of traces with evidence of clear EEG seizure activity were compared with physiological data recorded at the same time. RESULTS: 22/44 (50%) neonates who had aEEG monitoring were noted to have electrographic seizures. Physiologic download measurements were available for 11 of these neonates. In nine of these, an acute drop in oxygen saturation (SpO2) of at least 5% was noted in at least one seizure. Accompanying apnoeas were noted in three neonates. CONCLUSION: Acute decreases in SpO2 were seen in term neonates associated with seizures and these were not always accompanied by an apnoeic episode. Physiologic download in association with EEG monitoring may assist in improving seizure detection. Unexplained drops in SpO2 could indicate further investigation for possible seizures in at-risk neonates. IMPACT: A decrease in blood oxygen saturation (SpO2) associated with EEG seizures can occur in term infants with HIE or perinatal stroke. Drops in SpO2 associated with EEG seizures in term infants with HIE or stroke may occur in the absence of apnoeas. Unexplained acute falls in SpO2 in sick neonates may suggest possible seizures. Drops in SpO2 associated with seizures in term infants can occur over less than 3 minutes. Physiological monitoring alongside EEG monitoring could help to improve seizure detection.


Assuntos
Eletroencefalografia , Oximetria , Saturação de Oxigênio , Convulsões , Humanos , Recém-Nascido , Convulsões/diagnóstico , Convulsões/sangue , Convulsões/fisiopatologia , Feminino , Masculino , Oxigênio/sangue , Unidades de Terapia Intensiva Neonatal , Monitorização Fisiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA