1.
J Neurosci ; 44(3)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-37968115

RESUMO

Quantifying the effects of free breathing on cerebral venous flow is crucial for understanding cerebral circulation mechanisms and clinical applications. Unlike conventional cine phase-contrast MRI sequences (CINE-PC), real-time phase-contrast MRI sequences (RT-PC) can provide a continuous beat-to-beat flow signal that makes it possible to quantify the effect of breathing on cerebral venous flow. In this study, we examined 28 healthy human participants, comprising of 14 males and 14 females. Blood flows in the right/left internal jugular veins in the extracranial plane and the superior sagittal sinus (SSS) and straight sinus in the intercranial plane were quantified using CINE-PC and RT-PC. The first objective of this study was to determine the accuracy of RT-PC in quantifying cerebral venous flow, relative to CINE-PC. The second, and main objective, was to quantify the effect of free breathing on cerebral venous flow, using a time-domain multiparameter analysis method. Our results showed that RT-PC can accurately quantify cerebral venous flow with a 2 × 2 mm2 spatial resolution and 75 ms/image time resolution. The mean flow rate, amplitude, stroke volume, and cardiac period of cerebral veins were significantly higher from the mid-end phase of expiration to the mid-end phase of inspiration. Breathing affected the mean flow rates in the jugular veins more than those in the SSS and straight sinus. Furthermore, the effects of free breathing on the flow rate of the left and right jugular veins were not synchronous. These new findings provide a useful reference for better understanding the mechanisms of cerebral circulation.


Assuntos
Veias Cerebrais , Masculino , Adulto , Feminino , Humanos , Veias Cerebrais/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Imageamento por Ressonância Magnética/métodos , Circulação Cerebrovascular , Veias Jugulares/diagnóstico por imagem
2.
Am J Physiol Heart Circ Physiol ; 326(6): H1446-H1461, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38578237

RESUMO

Clinical failure of arteriovenous neointimal hyperplasia (NIH) fistulae (AVF) is frequently due to juxta-anastomotic NIH (JANIH). Although the mouse AVF model recapitulates human AVF maturation, previous studies focused on the outflow vein distal to the anastomosis. We hypothesized that the juxta-anastomotic area (JAA) has increased NIH compared with the outflow vein. AVF was created in C57BL/6 mice without or with chronic kidney disease (CKD). Temporal and spatial changes of the JAA were examined using histology and immunofluorescence. Computational techniques were used to model the AVF. RNA-seq and bioinformatic analyses were performed to compare the JAA with the outflow vein. The jugular vein to carotid artery AVF model was created in Wistar rats. The neointima in the JAA shows increased volume compared with the outflow vein. Computational modeling shows an increased volume of disturbed flow at the JAA compared with the outflow vein. Endothelial cells are immediately lost from the wall contralateral to the fistula exit, followed by thrombus formation and JANIH. Gene Ontology (GO) enrichment analysis of the 1,862 differentially expressed genes (DEG) between the JANIH and the outflow vein identified 525 overexpressed genes. The rat jugular vein to carotid artery AVF showed changes similar to the mouse AVF. Disturbed flow through the JAA correlates with rapid endothelial cell loss, thrombus formation, and JANIH; late endothelialization of the JAA channel correlates with late AVF patency. Early thrombus formation in the JAA may influence the later development of JANIH.NEW & NOTEWORTHY Disturbed flow and focal endothelial cell loss in the juxta-anastomotic area of the mouse AVF colocalizes with acute thrombus formation followed by late neointimal hyperplasia. Differential flow patterns between the juxta-anastomotic area and the outflow vein correlate with differential expression of genes regulating coagulation, proliferation, collagen metabolism, and the immune response. The rat jugular vein to carotid artery AVF model shows changes similar to the mouse AVF model.


Assuntos
Derivação Arteriovenosa Cirúrgica , Hiperplasia , Veias Jugulares , Camundongos Endogâmicos C57BL , Neointima , Ratos Wistar , Trombose , Animais , Trombose/fisiopatologia , Trombose/patologia , Trombose/genética , Trombose/etiologia , Trombose/metabolismo , Masculino , Veias Jugulares/metabolismo , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Modelos Animais de Doenças , Artérias Carótidas/patologia , Artérias Carótidas/fisiopatologia , Artérias Carótidas/metabolismo , Artérias Carótidas/cirurgia , Camundongos , Ratos , Fluxo Sanguíneo Regional , Endotélio Vascular/metabolismo , Endotélio Vascular/fisiopatologia , Endotélio Vascular/patologia , Insuficiência Renal Crônica/patologia , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/genética , Insuficiência Renal Crônica/metabolismo , Células Endoteliais/metabolismo , Células Endoteliais/patologia
3.
J Cardiovasc Electrophysiol ; 35(5): 1041-1045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462703

RESUMO

INTRODUCTION: Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. METHODS AND RESULTS: Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same-day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. CONCLUSIONS: We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.


Assuntos
Estimulação Cardíaca Artificial , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Veias Jugulares/cirurgia , Feminino , Idoso , Resultado do Tratamento , Desenho de Equipamento , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos
4.
Microvasc Res ; 154: 104688, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38640999

RESUMO

Arteriovenous fistula (AVF) failure often involves venous neointimal hyperplasia (VNH) driven by elevated hypoxia-inducible factor-1 alpha (HIF-1α) in the venous wall. Omentin, known for its anti-inflammatory and anti-hyperplasia properties, has an uncertain role in early AVF failure. This study investigates omentin's impact on VNH using a chronic renal failure (CRF) rabbit model. The CRF rabbit model of AVF received omentin-expressing adenoviral vector or control ß-gal vector to assess omentin's effects on VNH. Human vascular smooth muscle cells (HVSMCs), stimulated with tumor necrosis factor-α (TNF-α), were exposed to recombinant human omentin (Rh-OMT) to study its influence on cell proliferation and migration. The AMP-activated protein kinase (AMPK) inhibitor compound C and the mammalian target of rapamycin (mTOR) activator MHY1485 were employed to explore omentin's mechanisms in VNH reduction through HIF-1α inhibition. Omentin treatment reduced VNH in CRF rabbits, concomitant with HIF-1α down-regulation and the suppression of downstream factors, including vascular endothelial growth factor and matrix metalloproteinases. Rh-OMT inhibited TNF-α-induced HVSMC proliferation and migration by modulating both cell cycle and cell adhesion proteins. Additionally, omentin reduced HIF-1α expression through the AMPK/mTOR pathway activation. Notably, the blockade of AMPK/mTOR signaling reversed omentin-mediated inhibition of VNH, cell proliferation, and migration, both in vivo and in vitro. In conclusion, omentin mitigates VNH post-AVF creation by restraining HIF-1α via AMPK/mTOR signaling. Strategies boosting circulating omentin levels may offer promise in averting AVF failure.


Assuntos
Proteínas Quinases Ativadas por AMP , Derivação Arteriovenosa Cirúrgica , Movimento Celular , Proliferação de Células , Citocinas , Modelos Animais de Doenças , Proteínas Ligadas por GPI , Hiperplasia , Subunidade alfa do Fator 1 Induzível por Hipóxia , Lectinas , Músculo Liso Vascular , Miócitos de Músculo Liso , Neointima , Transdução de Sinais , Animais , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Citocinas/metabolismo , Coelhos , Humanos , Proteínas Ligadas por GPI/metabolismo , Proteínas Ligadas por GPI/farmacologia , Proteínas Ligadas por GPI/genética , Proliferação de Células/efeitos dos fármacos , Miócitos de Músculo Liso/patologia , Miócitos de Músculo Liso/metabolismo , Miócitos de Músculo Liso/efeitos dos fármacos , Lectinas/farmacologia , Lectinas/metabolismo , Movimento Celular/efeitos dos fármacos , Músculo Liso Vascular/patologia , Músculo Liso Vascular/metabolismo , Músculo Liso Vascular/efeitos dos fármacos , Proteínas Quinases Ativadas por AMP/metabolismo , Células Cultivadas , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Masculino , Falência Renal Crônica/patologia , Serina-Treonina Quinases TOR/metabolismo , Oclusão de Enxerto Vascular/patologia , Oclusão de Enxerto Vascular/prevenção & controle , Oclusão de Enxerto Vascular/metabolismo , Oclusão de Enxerto Vascular/fisiopatologia , Veias Jugulares/patologia , Veias Jugulares/metabolismo , Veias Jugulares/transplante
5.
Opt Lett ; 49(10): 2669-2672, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748132

RESUMO

Central venous oxygen saturation (ScvO2) is an important parameter for assessing global oxygen usage and guiding clinical interventions. However, measuring ScvO2 requires invasive catheterization. As an alternative, we aim to noninvasively and continuously measure changes in oxygen saturation of the internal jugular vein (SijvO2) by a multi-channel near-infrared spectroscopy system. The relation between the measured reflectance and changes in SijvO2 is modeled by Monte Carlo simulations and used to build a prediction model using deep neural networks (DNNs). The prediction model is tested with simulated data to show robustness to individual variations in tissue optical properties. The proposed technique is promising to provide a noninvasive tool for monitoring the stability of brain oxygenation in broad patient populations.


Assuntos
Veias Jugulares , Método de Monte Carlo , Saturação de Oxigênio , Veias Jugulares/fisiologia , Humanos , Saturação de Oxigênio/fisiologia , Redes Neurais de Computação , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino
6.
Circ J ; 88(7): 1127-1134, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658350

RESUMO

BACKGROUND: The Micra leadless pacemaker was developed to fit inside the right ventricle, thereby reducing overall complications by 48% compared with a historical control group. The current labeling restricts implants to the femoral approach. In this article we used 3-dimensional computer models of human hearts to demonstrate why implants can be difficult in small patients and how using the jugular approach reduces these difficulties.Methods and Results: Cardiac computed tomography scans were made of 45 pacemaker patients, 26 in the US and 19 from a single center in Japan. Dimensional measurements were taken in all 45 hearts, and these dimensions were compared between patient cohorts and between the Micra delivery tool dimension and patient heart dimensions. Hearts were smaller among patients in the Japanese than US cohort. In addition, the tool dimension exceeded heart dimensions in a larger percentage of hearts from Japanese patients. Three dimensions were identified that most likely limit navigating across the tricuspid valve to the right ventricle in smaller hearts and for which the jugular approach improved navigation. CONCLUSIONS: Although the femoral procedure today maintains an excellent safety profile and procedure experience for most global implants, this study provides the rationale as to why the jugular approach may improve the ease of the Micra implant in small hearts, namely by reducing the tortuosity of the navigation across the tricuspid valve.


Assuntos
Veias Jugulares , Marca-Passo Artificial , Humanos , Veias Jugulares/diagnóstico por imagem , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Ventrículos do Coração , Japão
7.
Semin Dial ; 37(1): 79-82, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37968773

RESUMO

Central venous catheter (CVC) provides ready vascular access and is widely used for the performance of hemodialysis. The use of CVC is associated with many complications and one life-threatening complication is central venous injury. We describe an unusual case of central venous injury in a 69-year-old lady with a poorly functioning left internal jugular vein catheter, which was in situ at the time of attempting insertion of a replacement right internal jugular catheter. The management included initial stabilization, urgent hemodialysis, imaging, and an endovascular approach to mitigate the iatrogenic venous injury. The case highlights many learning points. The operator needs to be vigilant for anatomical abnormalities like stenosis in patients who have had previous CVC. In those with central venous perforation, the CVC should be left in situ till a definitive management plan is formulated. An endovascular approach, when feasible, is a minimally invasive effective management strategy.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Feminino , Humanos , Idoso , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Diálise Renal/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/cirurgia , Doença Iatrogênica
8.
BMC Endocr Disord ; 24(1): 49, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654262

RESUMO

BACKGROUND: Papillary thyroid carcinoma (PTC), being the most common thyroid malignancy, is a slow-growing tumor and is usually limited to the thyroid. Extra thyroid extension is uncommon; besides, invasion to the vasculature seems to be extremely rare and usually indicates aggressive nature of the disease. CASE PRESENTATION: We present a case of a 40-year-old lady who referred with a palpable neck mass a month after total thyroidectomy which its histopathologic examination revealed follicular variant of PTC; the same variant as prior thyroidectomy. Preoperative ultrasonography failed to comment on the intravascular component of the mass. Surgical procedure confirmed a mass attaching and infiltrating to the internal jugular vein, which turned out to be persistent disease. CONCLUSIONS: Awareness of this entity is important for surgeons, oncologists and radiologist as it can influence patient management.


Assuntos
Carcinoma Papilar , Veias Jugulares , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide , Tireoidectomia , Humanos , Veias Jugulares/patologia , Veias Jugulares/diagnóstico por imagem , Feminino , Adulto , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/cirurgia , Câncer Papilífero da Tireoide/patologia , Carcinoma Papilar/patologia , Carcinoma Papilar/cirurgia , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/diagnóstico , Invasividade Neoplásica , Prognóstico
9.
Neuroradiology ; 66(6): 963-971, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38613702

RESUMO

PURPOSE: Few studies have investigated the influence of posture on the external jugular and diploic venous systems in the head and cranial region. In this study, we aimed to investigate the effects of posture on these systems using upright computed tomography (CT) scanning. METHODS: This study retrospectively analysed an upright CT dataset from a previous prospective study. In each patient, the diameters of the vessels in three external jugular tributaries and four diploic veins were measured using CT digital subtraction venography in both supine and sitting positions. RESULTS: Amongst the 20 cases in the original dataset, we eventually investigated 19 cases due to motion artifacts in 1 case. Compared with the supine position, most of the external jugular tributaries collapsed, and the average size significantly decreased in the sitting position (decreased by 22-49% on average). In contrast, most of the diploic veins, except the occipital diploic veins, tended to increase or remain unchanged (increased by 12-101% on average) in size in the sitting position compared with the supine position. However, the changes in the veins associated with this positional shift were not uniform; in approximately 5-30% of the cases, depending on each vein, an opposite trend was observed. CONCLUSION: Compared to the supine position, the contribution of external jugular tributaries to head venous drainage decreased in the sitting position, whilst most diploic veins maintained their contribution. These results could enhance our understanding of the physiology and pathophysiology of the head region in upright and sitting positions.


Assuntos
Angiografia Digital , Veias Jugulares , Humanos , Feminino , Masculino , Veias Jugulares/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Angiografia Digital/métodos , Adulto , Posicionamento do Paciente/métodos , Postura Sentada , Decúbito Dorsal , Veias Cerebrais/diagnóstico por imagem , Postura/fisiologia , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos
10.
J Intensive Care Med ; 39(7): 628-635, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38190576

RESUMO

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.


Assuntos
Artérias Carótidas , Hidratação , Veias Jugulares , Ultrassonografia Doppler , Humanos , Projetos Piloto , Masculino , Feminino , Hidratação/métodos , Pessoa de Meia-Idade , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos , Artérias Carótidas/diagnóstico por imagem , Idoso , Ressuscitação/métodos , Pressão Venosa Central/fisiologia , Estudos Retrospectivos , Adulto , Volume Sistólico/fisiologia , Débito Cardíaco/fisiologia , Serviço Hospitalar de Emergência , Hemodinâmica
11.
Int J Med Sci ; 21(3): 431-438, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38250605

RESUMO

This prospective observational study investigated the optimal insertion depth of the central venous catheter through the right internal jugular vein using transesophageal echocardiography. After tracheal intubation, the anesthesiologist inserted a probe for esophageal echocardiography into the patient's esophagus. The investigators placed the catheter tip 2 cm above the superior edge of the crista terminalis with echocardiography, which was defined as the optimal point. We measured the inserted length of the catheter. Pearson correlation tests were performed with the measured optimal depth and some patient parameters. We made a new formula for placing the catheter at the optimal position. A total of 89 subjects were enrolled in this trial. The correlation coefficient between the measured optimal depth and the patient's parameters was the highest for patient height (0.703, p < 0.001). We made a new formula of 'height (cm)/10 - 1.5 cm'. The accuracy rate of this formula for the optimal zone was 71.9% (95% confidence interval; 62.4 - 81.4%), which was the highest among the previous formulas or guidelines when we compared. In conclusion, the central venous catheter tip was evaluated with transesophageal echocardiography, and we could make a new formula of 'height (cm)/10 - 1.5', which seemed to be better than other previous guidelines.


Assuntos
Cateteres Venosos Centrais , Humanos , Ecocardiografia , Ecocardiografia Transesofagiana , Átrios do Coração , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos
12.
Acta Anaesthesiol Scand ; 68(4): 520-529, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38351546

RESUMO

BACKGROUND: There is a paucity of data on the incidence of central venous catheter tip misplacements after the implementation of ultrasound guidance during insertion. The aims of the present study were to determine the incidence of tip misplacements and to identify independent variables associated with tip misplacement. METHODS: All jugular and subclavian central venous catheter insertions in patients ≥16 years with a post-procedural chest radiography at four hospitals were included. Each case was reviewed for relevant catheter data and radiologic evaluations of chest radiographies. Tip misplacements were classified as 'any tip misplacement', 'minor tip misplacement' or 'major tip misplacement'. Multivariable logistic regression analyses were used to investigate associations between predefined independent variables and tip misplacements. RESULTS: A total of 8556 central venous catheter insertions in 5587 patients were included. Real-time ultrasound guidance was used in 91% of all insertions. Any tip misplacement occurred (95% confidence interval) in 3.7 (3.3-4.1)% of the catheterisations, and 2.1 (1.8-2.4)% were classified as major tip misplacements. The multivariable logistic regression analyses showed that female patient gender, subclavian vein insertions, number of skin punctures and limited operator experience were associated with a higher risk of major tip misplacement, whereas increasing age and height were associated with a lower risk. CONCLUSIONS: In this large prospective multicentre cohort study, performed in the ultrasound-guided era, we demonstrated the incidence of tip misplacements to be 3.7 (3.3-4.1)%. Right internal jugular vein catheterisation had the lowest incidence of both minor and major tip misplacement.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Humanos , Feminino , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Estudos Prospectivos , Estudos de Coortes , Ultrassonografia , Veias Jugulares/diagnóstico por imagem , Ultrassonografia de Intervenção
13.
Am J Emerg Med ; 78: 206-214, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38330835

RESUMO

BACKGROUND: Ultrasound-guided central venous catheterization (CVC) has become the standard of care. However, providers use a variety of approaches, encompassing the internal jugular vein (IJV), supraclavicular subclavian vein (SupraSCV), infraclavicular subclavian vein (InfraSCV), proximal axillary vein (ProxiAV), distal axillary vein (DistalAV), and femoral vein. OBJECTIVE: This review aimed to compare the first-pass success rate and arterial puncture rate for different approaches to ultrasound-guided CVC above the diaphragm. METHODS: In May 2023, Embase, MEDLINE, CENTRAL, ClinicalTrials.gov, and World Health Organization International Clinical Trials Platform were searched for randomized controlled trials (RCTs) comparing the 5 CVC approaches. The Confidence in Network Meta-Analysis tool was used to assess confidence. Thirteen RCTs (4418 participants and 13 comparisons) were included in this review. RESULTS: The SupraSCV approach likely increased the proportion of first-attempt successes compared to the other 4 approaches. The SupraSCV first-attempt success demonstrated risk ratios (RRs) > 1.21 with a lower 95% confidence interval (CI) exceeding 1. Compared to the IJV, the SupraSCV approach likely increased the first-attempt success proportion (RR 1.22; 95% confidence interval [CI] 1.06-1.40, moderate confidence), whereas the DistalAV approach reduced it (RR 0.72; 95% CI 0.59-0.87, high confidence). Artery puncture had little to no difference across all approaches (low to high confidence). CONCLUSION: Considering first-attempt success and mechanical complications, the SupraSCV may emerge as the preferred approach, while DistalAV might be the least preferable approach. Nevertheless, head-to-head studies comparing the approaches with the greatest first attempt success should be undertaken.


Assuntos
Cateterismo Venoso Central , Humanos , Metanálise em Rede , Ultrassonografia de Intervenção , Veia Subclávia/diagnóstico por imagem , Veias Braquiocefálicas , Veias Jugulares/diagnóstico por imagem
14.
BMC Anesthesiol ; 24(1): 68, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383304

RESUMO

BACKGROUND: A previous study on mechanical complications after central venous catheterisation demonstrated differences in complication rates between male and female operators. The objective of this subgroup analysis was to further investigate these differences. The hypothesis was that differences in distribution of predefined variables between operator genders could be identified. METHODS: This was a subgroup analysis of a prospective, multicentre, observational cohort study conducted between March 2019 and December 2020 including 8 586 patients ≥ 16 years receiving central venous catheters at four emergency care hospitals. The main outcome measure was major mechanical complications defined as major bleeding, severe cardiac arrhythmia, pneumothorax, arterial catheterisation, and persistent nerve injury. Independent t-test and χ2 test were used to investigate differences in distribution of major mechanical complications and predefined variables between male and female operators. Multivariable logistic regression analysis was used to determine association between operator gender and major mechanical complications. RESULTS: Female operators had a lower rate of major mechanical complications than male operators (0.4% vs 0.8%, P = .02), were less experienced (P < .001), had more patients with invasive positive pressure ventilation (P < .001), more often chose the internal jugular vein (P < .001) and more frequently used ultrasound guidance (P < .001). Male operators more often chose the subclavian vein (P < .001) and inserted more catheters with bore size ≥ 9 Fr (P < .001). Multivariable logistic regression analysis showed that male operator gender was associated with major mechanical complication (OR 2.67 [95% CI: 1.26-5.64]) after correction for other relevant independent variables. CONCLUSIONS: The hypothesis was confirmed as differences in distribution of predefined variables between operator genders were found. Despite being less experienced, female operators had a lower rate of major mechanical complications. Furthermore, male operator gender was independently associated with a higher risk of major mechanical complications. Future studies are needed to further investigate differences in risk behaviour between male and female operators. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03782324. Date of registration: 20/12/2018.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Feminino , Humanos , Masculino , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Veias Jugulares , Estudos Prospectivos , Fatores Sexuais , Ultrassonografia , Adolescente , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Adulto
15.
BMC Anesthesiol ; 24(1): 5, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166620

RESUMO

BACKGROUND: Centrally inserted central catheters (CICCs) are indispensable in modern healthcare, but unfortunately, come with complications. Catheter-related thrombosis is a well-known complication reported to occur in 5-30% of patients with CICC. There is a paucity of studies that report the incidence of catheter-related thrombosis after the introduction of real-time ultrasound insertion guidance as clinical practice. This study aimed to demonstrate any pathological macro- or microscopic changes in the vein wall associated with CICCs. METHODS: The study was approved by the Swedish Ethical Review Authority and was conducted at a large university hospital. The study included 12 patients with a short-term CICC who were subject to autopsies. Vessels with inserted catheters were macroscopically and microscopically examined. RESULTS: In total, seven female and five male patients with a median age of 70 (interquartile range 63-76) were included. With one exception, all patients received routine thromboprophylaxis throughout the period with CICC. Most inserted CICCs were 9.5 French (54%) and were inserted in the internal jugular vein (92%). The median time with CICC was seven days (interquartile range 1.8-20). At autopsy, thrombi were observed in all cases (100%), macroscopically and microscopically, attached to the distal portion of the CICC and/or the adjacent vessel wall. Inflammatory changes in the vessel walls were seen in all cases, and varying degrees of fibrosis were demonstrated in eight cases (67%). CONCLUSIONS: This autopsy study demonstrated that catheter-related thrombus formation with adjacent inflammatory and fibrotic vessel wall thickening was very common, despite a limited period of catheter use. The consequences of these findings are important, as thrombi may cause pulmonary embolism and possibly lead to catheter-related infections, and since inflammatory and fibrotic vessel wall thickening may evolve into chronic venous stenosis. Furthermore, the findings are a cause of concern, as CICCs are indispensable in modern healthcare and complications may be masked by the general disease that was the indication for CICC insertion.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Trombose , Tromboembolia Venosa , Humanos , Masculino , Feminino , Cateteres Venosos Centrais/efeitos adversos , Cateterismo Venoso Central/efeitos adversos , Anticoagulantes , Trombose/epidemiologia , Trombose/etiologia , Veias Jugulares , Autopsia , Cateteres de Demora
16.
Paediatr Anaesth ; 34(1): 86-88, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37728186

RESUMO

We report a case of aseptic cutaneous necrosis from extravasation of calcium chloride at the proximal port of a central venous catheter (CVC). A right internal jugular CVC was placed with ultrasound guidance using contemporary guidelines for size and insertion site. Catheter migration occurred concurrent with development of postoperative anasarca. Four days later, leakage of infusate with skin necrosis was noted at the insertion site. Despite initial proper positioning, catheter ports can migrate out of intravascular structures due to postprocedural subcutaneous edema. Intravascular confirmation should be performed regularly for infants with localized or generalized edema.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Recém-Nascido , Humanos , Cateteres Venosos Centrais/efeitos adversos , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Edema/etiologia , Necrose , Veias Jugulares/diagnóstico por imagem
17.
J Craniofac Surg ; 35(1): 243-246, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37646347

RESUMO

As the facial transplantation procedures are becoming more popular and frequent in recent years, for repairing facial trauma, variations in the veins of head and neck needs to be reported time and again. This study was undertaken to examine the course and drainage pattern of the facial vein and external jugular vein on this context and emphasize its surgical implications. The authors studied the head and neck region of 50 embalmed cadavers of both sexes to document normal and variant anatomy of facial, retromandibular, and external jugular veins. In 30% of the head and neck regions, different draining pattern of the above-mentioned veins were observed. One of the rare variation discovered was the splitting of the retromandibular vein to embrace the external carotid artery within the parotid gland. The data about variations in the termination of facial vein, retromandibular vein, and external jugular vein, as observed in the present study might be useful in avoiding accidental injury to these vessels during any surgical intervention in the face as well as neck. Level of Evidence: IV.


Assuntos
Cabeça , Veias Jugulares , Masculino , Feminino , Humanos , Veias Jugulares/cirurgia , Veias Jugulares/anatomia & histologia , Cabeça/irrigação sanguínea , Veia Subclávia , Pescoço/cirurgia , Pescoço/irrigação sanguínea , Drenagem
18.
J Clin Ultrasound ; 52(4): 456-463, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38169054

RESUMO

Hemodialysis (HD) arteriovenous fistulas commonly present with late vascular access complications, but are rarely in association with internal jugular vein (IJV) reflux. We reported two patients who had severe and mild IJV reflux, respectively. Case 1 was a 48-year-old male with end-stage renal disease (ESRD) who had been treated with HD for 5 years. He presented with persistent headaches, nausea, and vomiting. Combined with all the examinations, it was revealed severe IJV reflux, brachiocephalic vein stenosis, high-flow vascular access, and IJV valve dysfunction. Case 2 was a 59-year-old female with ESRD who had constructed an AVF for 4 months and had been on HD for only 1 day. She presented with dizziness and nausea after the first hemodialysis and duplex ultrasonography showed slightly continuous IJV reflux, high-flow vascular access, and IJV valve dysfunction. Furthermore, we reviewed 16 case reports to identify the characteristics of IJV reflux in HD patients. IJV reflux in HD patients may be caused by high-flow access, central venous stenosis or occlusion, and valve dysfunction. Severe IJV reflux can develop neurological symptoms secondary to intracranial venous reflux in this article. Etiological treatment is helpful for these patients, but there is a risk of recurrence.


Assuntos
Veias Jugulares , Falência Renal Crônica , Diálise Renal , Humanos , Pessoa de Meia-Idade , Veias Jugulares/diagnóstico por imagem , Masculino , Feminino , Falência Renal Crônica/terapia , Falência Renal Crônica/complicações , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Ultrassonografia Doppler Dupla/métodos
19.
Cell Tissue Bank ; 25(1): 55-66, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36917328

RESUMO

For decades, bovine jugular vein conduits (BJV) and classic cryopreserved homografts have been the two most widely used options for pulmonary valve replacement (PVR) in congenital heart disease. More recently, decellularized pulmonary homografts (DPH) have provided an alternative avenue for PVR. Matched comparison of patients who received DPH for PVR with patients who received bovine jugular vein conduits (BJV) considering patient age group, type of heart defect, and previous procedures. 319 DPH patients were matched to 319 BJV patients; the mean age of BJV patients was 15.3 (SD 9.5) years versus 19.1 (12.4) years in DPH patients (p = 0.001). The mean conduit diameter was 24.5 (3.5) mm for DPH and 20.3 (2.5) mm for BJV (p < 0.001). There was no difference in survival rates between the two groups after 10 years (97.0 vs. 98.1%, p = 0.45). The rate of freedom from endocarditis was significantly lower for BJV patients (87.1 vs. 96.5%, p = 0.006). Freedom from explantation was significantly lower for BJV at 10 years (81.7 vs. 95.5%, p = 0.001) as well as freedom from any significant degeneration at 10 years (39.6 vs. 65.4%, p < 0.001). 140 Patients, matched for age, heart defect type, prior procedures, and conduit sizes of 20-22 mm (± 2 mm), were compared separately; mean age BJV 8.7 (4.9) and DPH 9.5 (7.3) years (p = n.s.). DPH showed 20% higher freedom from explantation and degeneration in this subgroup (p = 0.232). Decellularized pulmonary homografts exhibit superior 10-year results to bovine jugular vein conduits in PVR.


Assuntos
Cardiopatias Congênitas , Valva Pulmonar , Humanos , Bovinos , Animais , Lactente , Adolescente , Criança , Valva Pulmonar/transplante , Veias Jugulares/transplante , Resultado do Tratamento , Cardiopatias Congênitas/cirurgia , Aloenxertos , Estudos Retrospectivos
20.
Surg Radiol Anat ; 46(7): 1001-1013, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38847825

RESUMO

PURPOSE: This study aims to assess the anatomical possibilities of the jugular bulb (JB). METHODS: Fifty archived CBCT scans were analyzed. RESULTS: The average distance between the internal acoustic canal (IAC) and the JB was 7.97 mm on both sides (Right: SD = 2.56 mm, range 3.16-13.3 mm; Left: SD = 2.5 mm, range 2.9-13.6 mm). JB walls' pneumatization was classified into eight patterns. Deep petrosal cells (DPCs) prevailed in the lateral wall of the JB. The absence of pneumatization (NP) was commonly found on the left side. The presence of infralabyrinthine and hypotympanic cells varied. Less common types included accessory occipital cells (AOCs), posteromedial tracts (PMTs), and basi-occipital cells (BOCs), which determined a consistent variation of the lateral wall pneumatization patterns. Pneumatization of the medial wall was not observed in 50 right sides and 49 left sides. The inferior wall analysis revealed symmetry in AOC distribution and a predominant occurrence of NP. Cases with hypotympanum (HT) in the lateral wall showed a statistically significant IAC-JB distance increase by an average of 4.67 mm compared to NPs. Specific pneumatizations, particularly HT on the lateral side, have a significant effect on the IAC-JB distance, showing a clear pattern of increasing distance from DPC to NP and then to HT. A significant distance increase in HT pneumatization was noted. There were also recorded instances of JB hypoplasia and hyperplasia, JB diverticula, dehiscent JBs, and high JBs. CONCLUSION: This study establishes a novel classification of JB pneumatizations to aid in the understanding of the temporal bone anatomy.


Assuntos
Variação Anatômica , Tomografia Computadorizada de Feixe Cônico , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/anatomia & histologia , Adolescente , Adulto Jovem , Forâmen Jugular/anatomia & histologia , Forâmen Jugular/diagnóstico por imagem , Idoso de 80 Anos ou mais , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA