Registration of 3-D intraoperative MR images of the brain using a finite-element biomechanical model.
IEEE Trans Med Imaging
; 20(12): 1384-97, 2001 Dec.
Article
in En
| MEDLINE
| ID: mdl-11811838
We present a new algorithm for the nonrigid registration of three-dimensional magnetic resonance (MR) intraoperative image sequences showing brain shift. The algorithm tracks key surfaces of objects (cortical surface and the lateral ventricles) in the image sequence using a deformable surface matching algorithm. The volumetric deformation field of the objects is then inferred from the displacements at the boundary surfaces using a linear elastic biomechanical finite-element model. Two experiments on synthetic image sequences are presented, as well as an initial experiment on intraoperative MR images showing brain shift. The results of the registration algorithm show a good correlation of the internal brain structures after deformation, and a good capability of measuring surface as well as subsurface shift. We measured distances between landmarks in the deformed initial image and the corresponding landmarks in the target scan. Cortical surface shifts of up to 10 mm and subsurface shifts of up to 6 mm were recovered with an accuracy of 1 mm or less and 3 mm or less respectively.
Search on Google
Database:
MEDLINE
Main subject:
Brain
/
Magnetic Resonance Imaging
/
Imaging, Three-Dimensional
/
Models, Neurological
Type of study:
Diagnostic_studies
/
Prognostic_studies
Limits:
Humans
Language:
En
Journal:
IEEE Trans Med Imaging
Year:
2001
Type:
Article
Affiliation country:
Belgium