Your browser doesn't support javascript.
loading
Prevalence and density-related concordance of three diagnostic tests for malaria in a region of Tanzania with hypoendemic malaria.
Schachterle, Stephen E; Mtove, George; Levens, Joshua P; Clemens, Emily G; Shi, Lirong; Raj, Amirita; Munoz, Beatrice; Reller, Megan E; West, Sheila; Dumler, J Stephen; Sullivan, David.
Affiliation
  • Schachterle SE; Department of Epidemiology, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD 21205, USA.
J Clin Microbiol ; 49(11): 3885-91, 2011 Nov.
Article in En | MEDLINE | ID: mdl-21880972
ABSTRACT
Accurate malaria diagnosis has dual roles in identification of symptomatic persons for effective malaria treatment and also enumeration of asymptomatic persons who contribute to the epidemiologic determinants of transmission. Three currently used diagnostic tests, microscopy, rapid diagnostic tests (RDTs), and real-time PCR, all have different sensitivities and specificities, which are parasite density dependent. Here, we compare their concordance among 451 febrile episodes in a cohort of 2,058 children and adults followed over 6 months in a region in central Tanzania with hypoendemic malaria. Microscopy, a histidine-rich protein-based RDT, and two different real-time PCR gene probes detected Plasmodium falciparum in 20, 54, 41, and 78 episodes of fever, respectively. They had complete concordance in only 9 episodes. Real-time PCR with an 18S probe was more sensitive than with a mitochondrial probe for cytochrome b despite higher copy numbers of mitochondrial DNA. Both PCR yields were increased 4-fold by glycogen/acetate precipitation with low-speed centrifugation. Duplicate PCR increases low-density malaria detection. RDT had the highest number of unique positives, presumably from persistent antigen despite the absence of parasites, although RDT did not detect 3 parasitemias with over 1,000 parasites/µl. In a latent class analysis, real-time PCR had significantly higher sensitivity than did microscopy or RDT. Agreement between real-time PCR, RDT, and microscopy was highest in March and April, when both the P. falciparum parasite rate and parasite densities are highest. Real-time PCR is more sensitive and specific than RDT and microscopy in low-prevalence, low-parasite-density settings.
Subject(s)

Full text: 1 Database: MEDLINE Main subject: Parasitology / Endemic Diseases / Diagnostic Tests, Routine / Malaria Type of study: Diagnostic_studies / Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Animals / Child / Child, preschool / Humans / Infant Country/Region as subject: Africa Language: En Journal: J Clin Microbiol Year: 2011 Type: Article Affiliation country: United States

Full text: 1 Database: MEDLINE Main subject: Parasitology / Endemic Diseases / Diagnostic Tests, Routine / Malaria Type of study: Diagnostic_studies / Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Animals / Child / Child, preschool / Humans / Infant Country/Region as subject: Africa Language: En Journal: J Clin Microbiol Year: 2011 Type: Article Affiliation country: United States