Your browser doesn't support javascript.
loading
Indications for inferior vena cava filter placement: do physicians comply with guidelines?
Baadh, Amanjit S; Zikria, Joseph F; Rivoli, Stephen; Graham, Robert E; Javit, Daniel; Ansell, Jack E.
Affiliation
  • Baadh AS; Department of Medicine, Lenox Hill Hospital, 100 East 77th St., New York, NY 10075, USA. andybaadh@yahoo.com
J Vasc Interv Radiol ; 23(8): 989-95, 2012 Aug.
Article in En | MEDLINE | ID: mdl-22698970
PURPOSE: Inferior vena cava (IVC) filter placement has increased significantly over the past few decades, but indications for filter placement vary widely depending on which professional society recommendations are followed, and it is uncertain how compliant physicians are in adhering to guidelines. This study assessed documented indications for IVC filter placement and evaluated compliance with standards set by the American College of Chest Physicians (ACCP) and the Society of Interventional Radiology (SIR). MATERIALS AND METHODS: A single-center, retrospective medical record review in a metropolitan, 652-bed, acute care, teaching hospital. Inpatient filter placement over a 26-month period was reviewed. The study measured compliance with established guidelines, relationship of medical specialty to filter placement, and evaluation of self-referral patterns among physicians. RESULTS: Compliance with established ACCP guidelines was poor regardless of whether the IVC filter insertion was performed by interventional radiology (IR; 43.5%), vascular surgery (VS; 39.9%), or interventional cardiology (IC; 33.3%) staff. Compliance with the less restrictive SIR guidelines was better (77.5%, 77.1%, and 80% for IR, VS, and IC, respectively). There was a greater degree of guideline compliance when filter placement was recommended by internal medicine (IM)-trained physicians than by non-IM-trained physicians: 46.3% of IR-placed filters requested by IM physicians met ACCP criteria whereas only 24.0% of filters recommended by non-IM specialties were compliant with criteria (P = .03). In the VS group, these compliance rates were 45.8% and 31.5%, respectively (P = .03). Among IR-placed filters, 84.0% of IM-recommended filter placements were compliant with SIR guidelines, versus only 48.0% of non-IM-recommended placements (P ≤ .001). In the VS group, these compliance rates were 87.8% and 69.6%, respectively (P ≤ .001). CONCLUSIONS: There is poor physician compliance with guidelines for IVC filter placement. Most filter indications meeting SIR guidelines are for patients classified as "falls risks," failures of anticoagulation, patients with limited cardiopulmonary reserve and patients non compliant with anticoagulation medications. This single-center study suggests a need for harmonization of current guidelines espoused by professional societies.
Subject(s)

Full text: 1 Database: MEDLINE Main subject: Practice Patterns, Physicians' / Vena Cava Filters / Practice Guidelines as Topic / Patient Selection / Guideline Adherence / Prosthesis Implantation Type of study: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: America do norte Language: En Journal: J Vasc Interv Radiol Journal subject: ANGIOLOGIA / RADIOLOGIA Year: 2012 Type: Article Affiliation country: United States

Full text: 1 Database: MEDLINE Main subject: Practice Patterns, Physicians' / Vena Cava Filters / Practice Guidelines as Topic / Patient Selection / Guideline Adherence / Prosthesis Implantation Type of study: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: America do norte Language: En Journal: J Vasc Interv Radiol Journal subject: ANGIOLOGIA / RADIOLOGIA Year: 2012 Type: Article Affiliation country: United States