PURPOSE: Inferior vena cava (IVC) filter placement has increased significantly over the past few decades, but indications for filter placement vary widely depending on which professional society recommendations are followed, and it is uncertain how compliant physicians are in adhering to guidelines. This study assessed documented indications for IVC filter placement and evaluated compliance with standards set by the American College of Chest Physicians (ACCP) and the Society of Interventional Radiology (SIR). MATERIALS AND METHODS: A single-center, retrospective medical record review in a metropolitan, 652-bed, acute care, teaching hospital. Inpatient filter placement over a 26-month period was reviewed. The study measured compliance with established guidelines, relationship of medical specialty to filter placement, and evaluation of self-referral patterns among physicians. RESULTS: Compliance with established ACCP guidelines was poor regardless of whether the IVC filter insertion was performed by interventional radiology (IR; 43.5%), vascular surgery (VS; 39.9%), or interventional cardiology (IC; 33.3%) staff. Compliance with the less restrictive SIR guidelines was better (77.5%, 77.1%, and 80% for IR, VS, and IC, respectively). There was a greater degree of guideline compliance when filter placement was recommended by internal medicine (IM)-trained physicians than by non-IM-trained physicians: 46.3% of IR-placed filters requested by IM physicians met ACCP criteria whereas only 24.0% of filters recommended by non-IM specialties were compliant with criteria (P = .03). In the VS group, these compliance rates were 45.8% and 31.5%, respectively (P = .03). Among IR-placed filters, 84.0% of IM-recommended filter placements were compliant with SIR guidelines, versus only 48.0% of non-IM-recommended placements (P ≤ .001). In the VS group, these compliance rates were 87.8% and 69.6%, respectively (P ≤ .001). CONCLUSIONS: There is poor physician compliance with guidelines for IVC filter placement. Most filter indications meeting SIR guidelines are for patients classified as "falls risks," failures of anticoagulation, patients with limited cardiopulmonary reserve and patients non compliant with anticoagulation medications. This single-center study suggests a need for harmonization of current guidelines espoused by professional societies.
Full text:
1
Database:
MEDLINE
Main subject:
Practice Patterns, Physicians'
/
Vena Cava Filters
/
Practice Guidelines as Topic
/
Patient Selection
/
Guideline Adherence
/
Prosthesis Implantation
Type of study:
Etiology_studies
/
Guideline
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limits:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Country/Region as subject:
America do norte
Language:
En
Journal:
J Vasc Interv Radiol
Journal subject:
ANGIOLOGIA
/
RADIOLOGIA
Year:
2012
Type:
Article
Affiliation country:
United States