Your browser doesn't support javascript.
loading
Time Multiplexed Active Neural Probe with 1356 Parallel Recording Sites.
Raducanu, Bogdan C; Yazicioglu, Refet F; Lopez, Carolina M; Ballini, Marco; Putzeys, Jan; Wang, Shiwei; Andrei, Alexandru; Rochus, Veronique; Welkenhuysen, Marleen; Helleputte, Nick van; Musa, Silke; Puers, Robert; Kloosterman, Fabian; Hoof, Chris van; Fiáth, Richárd; Ulbert, István; Mitra, Srinjoy.
Affiliation
  • Raducanu BC; Imec, 3001 Leuven, Belgium. raducanu@imec.be.
  • Yazicioglu RF; Electrical Engineering Department-ESAT, KU Leuven, 3001 Leuven, Belgium. raducanu@imec.be.
  • Lopez CM; Imec, 3001 Leuven, Belgium. firatyazicioglu@gmail.com.
  • Ballini M; Imec, 3001 Leuven, Belgium. moralope@imec.be.
  • Putzeys J; Imec, 3001 Leuven, Belgium. Marco.Ballini@imec.be.
  • Wang S; Imec, 3001 Leuven, Belgium. Jan.Putzeys@imec.be.
  • Andrei A; Imec, 3001 Leuven, Belgium. Shiwei.Wang@imec.be.
  • Rochus V; Imec, 3001 Leuven, Belgium. Alexandru.Andrei@imec.be.
  • Welkenhuysen M; Imec, 3001 Leuven, Belgium. Veronique.Rochus@imec.be.
  • Helleputte NV; Imec, 3001 Leuven, Belgium. Marleen.Welkenhuysen@imec.be.
  • Musa S; Imec, 3001 Leuven, Belgium. Nick.VanHelleputte@imec.be.
  • Puers R; Imec, 3001 Leuven, Belgium. Silke.Musa@imec.be.
  • Kloosterman F; Imec, 3001 Leuven, Belgium. robert.puers@esat.kuleuven.be.
  • Hoof CV; Electrical Engineering Department-ESAT, KU Leuven, 3001 Leuven, Belgium. robert.puers@esat.kuleuven.be.
  • Fiáth R; Faculty of Psychology and Educational Sciences, KU Leuven, 3000 Leuven, Belgium. Chris.VanHoof@imec.be.
  • Ulbert I; Neuro-electronics Research Flanders, 3001 Leuven, Belgium. Chris.VanHoof@imec.be.
  • Mitra S; VIB, 3000 Leuven, Belgium. Chris.VanHoof@imec.be.
Sensors (Basel) ; 17(10)2017 Oct 19.
Article in En | MEDLINE | ID: mdl-29048396
ABSTRACT
We present a high electrode density and high channel count CMOS (complementary metal-oxide-semiconductor) active neural probe containing 1344 neuron sized recording pixels (20 µm × 20 µm) and 12 reference pixels (20 µm × 80 µm), densely packed on a 50 µm thick, 100 µm wide, and 8 mm long shank. The active electrodes or pixels consist of dedicated in-situ circuits for signal source amplification, which are directly located under each electrode. The probe supports the simultaneous recording of all 1356 electrodes with sufficient signal to noise ratio for typical neuroscience applications. For enhanced performance, further noise reduction can be achieved while using half of the electrodes (678). Both of these numbers considerably surpass the state-of-the art active neural probes in both electrode count and number of recording channels. The measured input referred noise in the action potential band is 12.4 µVrms, while using 678 electrodes, with just 3 µW power dissipation per pixel and 45 µW per read-out channel (including data transmission).
Key words

Full text: 1 Database: MEDLINE Language: En Journal: Sensors (Basel) Year: 2017 Type: Article Affiliation country: Belgium

Full text: 1 Database: MEDLINE Language: En Journal: Sensors (Basel) Year: 2017 Type: Article Affiliation country: Belgium