Your browser doesn't support javascript.
loading
Added Value of 3- Versus 2-Dimensional Echocardiography Left Ventricular Ejection Fraction to Predict Arrhythmic Risk in Patients With Left Ventricular Dysfunction.
Rodríguez-Zanella, Hugo; Muraru, Denisa; Secco, Eleonora; Boccalini, Francesca; Azzolina, Danila; Aruta, Patrizia; Surkova, Elena; Genovese, Davide; Cavalli, Giacomo; Sammarco, Giuseppe; Ruozi, Niccolò; Tenaglia, Rosaria M; Calvillo-Argüelles, Oscar; Palermo, Chiara; Iliceto, Sabino; Badano, Luigi P.
Affiliation
  • Rodríguez-Zanella H; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy; National Institute of Cardiology of Mexico, Ignacio Chávez, México City, Mexico.
  • Muraru D; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy. Electronic address: denisa.muraru@gmail.com.
  • Secco E; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Boccalini F; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Azzolina D; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Aruta P; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Surkova E; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy; Royal Brompton Hospital, Royal Brompton and Harefield NHS Foundation Trust, London, England.
  • Genovese D; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Cavalli G; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Sammarco G; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Ruozi N; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Tenaglia RM; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Calvillo-Argüelles O; National Institute of Cardiology of Mexico, Ignacio Chávez, México City, Mexico.
  • Palermo C; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Iliceto S; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
  • Badano LP; Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
JACC Cardiovasc Imaging ; 12(10): 1917-1926, 2019 10.
Article in En | MEDLINE | ID: mdl-30219408
OBJECTIVES: This study sought to evaluate the potential clinical impact of using 3-dimensional echocardiography (3DE) to measure left ventricular ejection fraction (LVEF) in patients considered for implantable cardioverter-defibrillator (ICD) implantation and to assess the predictive value of 3DE LVEF for arrhythmic events. BACKGROUND: ICD therapy is currently recommended to prevent sudden cardiac death in patients with symptomatic heart failure and LVEF ≤35%, and in asymptomatic patients with ischemic heart disease and LVEF ≤30%. Two-dimensional echocardiography (2DE) is currently used to calculate LVEF. However, 3DE has been reported to be more reproducible and accurate than 2DE to measure LVEF. METHODS: The study prospectively enrolled 172 patients with LV dysfunction (71% ischemic). Both 2DE and 3DE LVEF were obtained during the same study. The outcome was the occurrence of major arrhythmic events (sudden cardiac death, aborted cardiac arrest, appropriate ICD therapy). RESULTS: After a median follow up of 56 (range 18 to 65) months, major arrhythmic events occurred in 30% of the patients. Compared with 2DE, 3DE changed the assignment above or below the LVEF thresholds for ICD implantation in 20% of patients, most of them having 2DE LVEFs within ± 10% from threshold. By cause-specific hazard model, 3DE LVEF was the only independent predictor of the occurrence of major arrhythmic events. CONCLUSIONS: LVEF by 3DE was an independent predictor of major arrhythmic events and improved arrhythmic risk prediction in patients with LV dysfunction. When compared with 2DE LVEF, 3DE measurement of LVEF may change the decision to implant an ICD in a sizable number of patients.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Arrhythmias, Cardiac / Stroke Volume / Ventricular Function, Left / Ventricular Dysfunction, Left / Echocardiography, Three-Dimensional Type of study: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: JACC Cardiovasc Imaging Journal subject: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Year: 2019 Type: Article Affiliation country: Mexico

Full text: 1 Database: MEDLINE Main subject: Arrhythmias, Cardiac / Stroke Volume / Ventricular Function, Left / Ventricular Dysfunction, Left / Echocardiography, Three-Dimensional Type of study: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: JACC Cardiovasc Imaging Journal subject: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Year: 2019 Type: Article Affiliation country: Mexico