The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis.
Cha, Jae-Kook; Paeng, Kyeongwon; Jung, Ui-Won; Choi, Seong-Ho; Sanz, Mariano; Sanz-Martín, Ignacio.
Affiliation
  • Cha JK; Department of Periodontology, College of Dentistry, Research Institute for Periodontal Regeneration, Yonsei University, Seoul, Korea.
  • Paeng K; Department of Periodontology, College of Dentistry, Research Institute for Periodontal Regeneration, Yonsei University, Seoul, Korea.
  • Jung UW; Department of Periodontology, College of Dentistry, Research Institute for Periodontal Regeneration, Yonsei University, Seoul, Korea.
  • Choi SH; Department of Periodontology, College of Dentistry, Research Institute for Periodontal Regeneration, Yonsei University, Seoul, Korea.
  • Sanz M; Section of graduate Periodontology, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.
  • Sanz-Martín I; ETEP (Etiology and Therapy of Periodontal diseases) Research Group, University Complutense of Madrid, Madrid, Spain.
Clin Oral Implants Res ; 30(6): 578-587, 2019 Jun.
Article in En | MEDLINE | ID: mdl-31022305
ABSTRACT

OBJECTIVE:

To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols. MATERIAL AND

METHODS:

Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces.

RESULTS:

The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect.

CONCLUSION:

Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Dental Implants Language: En Journal: Clin Oral Implants Res Journal subject: ODONTOLOGIA Year: 2019 Type: Article