Your browser doesn't support javascript.
loading
CRISPR/dCas9-mediated biosensor for detection of tick-borne diseases.
Koo, Bonhan; Kim, Da-Eun; Kweon, Jiyeon; Jin, Choong Eun; Kim, Sung-Han; Kim, Yongsub; Shin, Yong.
Affiliation
  • Koo B; Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 lympicro-43gil, Songpa-gu, Seoul, Republic of Korea.
  • Kim DE; Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 lympicro-43gil, Songpa-gu, Seoul, Republic of Korea.
  • Kweon J; Department of Chemistry, Seoul National University, Gwanak-ro, Gwanak-gu, Seoul, Republic of Korea.
  • Jin CE; Center for Genome Engineering, Institute for Basic Science (IBS), Gwanak-ro, Gwanak-gu, Seoul, Republic of Korea.
  • Kim SH; Department of Biomedical Sciences, University of Ulsan College of Medicine, Asan Medical Center, 88 lympicro-43gil, Songpa-gu, Seoul, Republic of Korea.
  • Kim Y; Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 lympicro-43gil, Songpa-gu, Seoul, Republic of Korea.
  • Shin Y; Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 lympicro-43gil, Songpa-gu, Seoul, Republic of Korea.
Sens Actuators B Chem ; 273: 316-321, 2018 Nov 10.
Article in En | MEDLINE | ID: mdl-32288252
Rapid and highly sensitive detection of biomolecules is greatly needed for pathogen diagnosis in clinical samples, but the method needs to be significantly improved in terms of sensitivity and specificity for actual use in clinical settings. Here, we report the development of an improved molecular diagnostics tool that utilizes CRISPR/dCas9-mediated biosensor that couples a nuclease inactivated Cas9 (dCas9) and single microring resonator biosensor, enables label-free and real-time detection of pathogenic DNA and RNA. We addressed the clinical utility of this CRISPR/dCas9-mediated biosensor in tick-borne illnesses including scrub typhus (ST) and severe fever with thrombocytopenia syndrome (SFTS), whose clinical presentations are too similar to be easily differentiated. By using CRISPR/dCas9-mediated biosensor, we achieved single molecule sensitivity for the detection of ST (0.54 aM) and SFTS (0.63 aM); this detection sensitivity is 100 times more sensitive than that of RT-PCR assay. Finally, CRISPR/dCas9-mediated biosensor was able to clearly distinguish between ST and SFTS in serum samples within 20 min. We believe that CRISPR/dCas9-mediated biosensor will be useful for rapid and accurate molecular diagnostic tool that is suitable for immediate clinical applications.
Key words

Full text: 1 Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Sens Actuators B Chem Year: 2018 Type: Article

Full text: 1 Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Sens Actuators B Chem Year: 2018 Type: Article