Your browser doesn't support javascript.
loading
Insulin glargine 300 units/mL for the treatment of individuals with type 2 diabetes in the real world: A review of the DELIVER programme.
Blonde, Lawrence; Bailey, Timothy; Sullivan, Sean D; Freemantle, Nick.
Affiliation
  • Blonde L; Frank Riddick Diabetes Institute, Department of Endocrinology, Ochsner Medical Center, New Orleans, Louisiana, USA.
  • Bailey T; AMCR Institute, Escondido, California, USA.
  • Sullivan SD; The CHOICE Institute, School of Pharmacy, University of Washington, Seattle, Washington, USA.
  • Freemantle N; Institute of Clinical Trials and Methodology, University College London, London, UK.
Diabetes Obes Metab ; 23(8): 1713-1721, 2021 08.
Article in En | MEDLINE | ID: mdl-33881797
ABSTRACT
Evidence from randomized controlled trials (RCTs) has shown that second-generation basal insulin (BI) analogues, insulin glargine 300 U/mL (Gla-300) and insulin degludec (IDeg), provide similar glycaemic control, with a lower risk of hypoglycaemia compared with the first-generation BI analogue insulin glargine 100 U/mL (Gla-100) in people with type 2 diabetes (T2D). However, the highly selected participants and frequent follow-up of RCTs may not be truly representative of real-life clinical practice. It is important to assess the safety and effectiveness of these second-generation BI analogues in real-life clinical practice settings. The DELIVER programme utilized electronic healthcare records from the United States to compare clinical outcomes in people with T2D who received either Gla-300 or other BI analogues in real-world clinical practice. This review provides a concise overview of the results of the DELIVER studies. Overall, Gla-300 provided similar antihyperglycaemic effectiveness and a lower risk of hypoglycaemia versus the first-generation BI analogues Gla-100 and insulin detemir in people with T2D who had switched BIs. In those who were insulin-naïve, initiation with Gla-300 versus Gla-100 was associated with significantly better antihyperglycaemic effectiveness and similar or lower hypoglycaemic risk. Both glycaemic control and hypoglycaemia risk were also shown to be similar with Gla-300 and IDeg, in people who had switched BIs and in those who were insulin-naïve. In addition, the DELIVER 2 study reported that people with T2D who switched to Gla-300 had reduced healthcare resource utilization, with an overall saving of US$1439 per person per year compared with those who switched to another BI analogue. Overall, the real-world DELIVER programme showed that the glycaemic control with a low risk of hypoglycaemia observed with Gla-300 in RCTs was also seen in standard clinical practice.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Diabetes Mellitus, Type 2 / Hypoglycemia Type of study: Clinical_trials Limits: Humans Language: En Journal: Diabetes Obes Metab Journal subject: ENDOCRINOLOGIA / METABOLISMO Year: 2021 Type: Article Affiliation country: United States

Full text: 1 Database: MEDLINE Main subject: Diabetes Mellitus, Type 2 / Hypoglycemia Type of study: Clinical_trials Limits: Humans Language: En Journal: Diabetes Obes Metab Journal subject: ENDOCRINOLOGIA / METABOLISMO Year: 2021 Type: Article Affiliation country: United States