Your browser doesn't support javascript.
loading
Feasibility of using digital confocal microscopy for cytopathological examination in clinical practice.
Krishnamurthy, Savitri; Ban, Kechen.
Affiliation
  • Krishnamurthy S; Department of Pathology and Laboratory Medicine, The University of Texas, MD Anderson Cancer Center, Houston, TX, USA. skrishna@mdanderson.org.
  • Ban K; Department of Neurosurgery Research, The University of Texas, MD Anderson Cancer Center Houston, Houston, TX, USA.
Mod Pathol ; 35(3): 319-325, 2022 03.
Article in En | MEDLINE | ID: mdl-34628480
ABSTRACT
Optical imaging modalities are emerging as digital microscopy tools for tissue examination. The investigation of these techniques for potential applications in anatomic pathology practice has focused primarily on surgical pathology and has not included cytopathological specimens. We evaluated the feasibility of using digital confocal microscopy (CM) to examine cytopathological specimens. Smears and cell suspensions collected in RPMI solution were prepared from tissue scrapes obtained from surgical resections of breast, lung, liver, and kidney. Air-dried smears and cell pellets obtained from centrifugation of the cell suspensions were stained with 0.6 mM acridine orange and imaged with a CM platform. After completion of imaging, the smears were stained with Diff-Quik (DQ), and cell pellets were routinely processed, embedded in paraffin wax, cut, and stained with hematoxylin and eosin (H&E). We evaluated the mean time to acquire digital CM images; quality of images based on the extent of tissue recognition (0%, grade 0; 1-19%, grade 1; 20-50%, grade 2; >50%, grade 3); comparison of images with DQ- and H&E-stained specimens; and ability to make specific diagnoses. We imaged 91 smears and 52 cell pellets and acquired digital CM images within 2-3 min, with 92% and 88% of images, respectively, from smears and cell pellets showing grade 3 quality. On the basis of CM images, 8 smears (9%) and 7 cell pellets (14%) were categorized as benign, and 83 (91%) and 45 (88%), respectively, as malignant. Specific diagnoses were made by using digital CM images of smears and cell pellets that matched accurately with corresponding DQ- and H&E-stained preparations. The results of our first feasibility study clearly indicated the utility of CM as a next-generation digital microscopy tool for evaluating cytology specimens. Prospective clinical studies are warranted for validating our findings for potential incorporation into cytopathological clinical practice.
Subject(s)

Full text: 1 Database: MEDLINE Main subject: Pathology, Surgical Type of study: Observational_studies Limits: Humans Language: En Journal: Mod Pathol Journal subject: PATOLOGIA Year: 2022 Type: Article Affiliation country: United States

Full text: 1 Database: MEDLINE Main subject: Pathology, Surgical Type of study: Observational_studies Limits: Humans Language: En Journal: Mod Pathol Journal subject: PATOLOGIA Year: 2022 Type: Article Affiliation country: United States