Your browser doesn't support javascript.
loading
ICP-MS Determination of 23 Elements of Potential Health Concern in Liquids of e-Cigarettes. Method Development, Validation, and Application to 37 Real Samples.
Mara, Andrea; Langasco, Ilaria; Deidda, Sara; Caredda, Marco; Meloni, Paola; Deroma, Mario; Pilo, Maria I; Spano, Nadia; Sanna, Gavino.
Affiliation
  • Mara A; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
  • Langasco I; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
  • Deidda S; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
  • Caredda M; AGRIS Sardegna, Loc. Bonassai, S.S. 291 Km 18.6, 07100 Sassari, Italy.
  • Meloni P; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
  • Deroma M; Dipartimento di Agraria, Università degli Studi di Sassari, Viale Italia 39/a, 07100 Sassari, Italy.
  • Pilo MI; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
  • Spano N; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
  • Sanna G; Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy.
Molecules ; 26(21)2021 Nov 04.
Article in En | MEDLINE | ID: mdl-34771088
ABSTRACT
The lack of interest in the determination of toxic elements in liquids for electronic cigarettes (e-liquids) has so far been reflected in the scarce number of accurate and validated analytical methods devoted to this aim. Since the strong matrix effects observed for e-liquids constitute an exciting analytical challenge, the main goal of this study was to develop and validate an ICP-MS method aimed to quantify 23 elements in 37 e-liquids of different flavors. Great attention has been paid to the critical phases of sample pre-treatment, as well as to the optimization of the ICP-MS conditions for each element and of the quantification. All samples exhibited a very low amount of the elements under investigation. Indeed, the sum of their average concentration was of ca. 0.6 mg kg-1. Toxic elements were always below a few tens of a µg per kg-1 and, very often, their amount was below the relevant quantification limits. Tobacco and tonic flavors showed the highest and the lowest concentration of elements, respectively. The most abundant elements came frequently from propylene glycol and vegetal glycerin, as confirmed by PCA. A proper choice of these substances could further decrease the elemental concentration in e-liquids, which are probably barely involved as potential sources of toxic elements inhaled by vapers.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Mass Spectrometry / Health Impact Assessment / Electronic Nicotine Delivery Systems Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2021 Type: Article Affiliation country: Italy

Full text: 1 Database: MEDLINE Main subject: Mass Spectrometry / Health Impact Assessment / Electronic Nicotine Delivery Systems Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2021 Type: Article Affiliation country: Italy