Your browser doesn't support javascript.
loading
Effectiveness of Implantable Cardioverter Defibrillator in Patients With Non-Ischemic Heart Failure With Systolic Dysfunction - Subanalysis of the Nippon Storm Study.
Sasaki, Shingo; Noda, Takashi; Okumura, Ken; Nitta, Takashi; Aizawa, Yoshifusa; Ohe, Tohru; Kurita, Takashi.
Affiliation
  • Sasaki S; Department of Cardiology and Nephrology, Hirosaki University Graduate School of Medicine.
  • Noda T; Department of Cardiovascular Medicine, Tohoku University Graduate School of Medicine.
  • Okumura K; Advanced Arrhythmia Therapeutic Branch Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center.
  • Nitta T; Department of Cardiovascular Surgery, Hanyu General Hospital.
  • Aizawa Y; Department of Research and Development, Tachikawa Medical Center.
  • Ohe T; Okayama City Hospital.
  • Kurita T; Department of Internal Medicine, Faculty of Medicine, Kindai University.
Circ J ; 87(1): 92-100, 2022 12 23.
Article in En | MEDLINE | ID: mdl-35922910
BACKGROUND: The prospective observational Nippon Storm Study aggregated clinical data from Japanese patients receiving implantable cardioverter-defibrillator (ICD) therapy. This study investigated the usefulness of prophylactic ICD therapy in patients with non-ischemic heart failure (NIHF) enrolled in the study.Methods and Results: We analyzed 540 NIHF patients with systolic dysfunction (left ventricular ejection fraction <50%). Propensity score matching was used to select patient subgroups for comparison; 126 patients were analyzed in each of the primary (PP) and secondary (SP) prophylaxis groups. The incidence of appropriate ICD therapy during follow-up in the PP and SP groups was 21.4% and 31.7%, respectively (P=0.044). The incidence of electrical storm (ES) was higher in SP than PP patients (P=0.024). Cox proportional hazard analysis revealed that increased serum creatinine in SP patients (hazard ratio [HR] 1.18; 95% confidence interval [CI] 1.02-1.33; P=0.013) and anemia in PP patients (HR 0.92; 95% CI 0.86-0.98; P=0.008) increased the likelihood of appropriate ICD therapy, whereas long-lasting atrial fibrillation in PP patients (HR, 0.64 [95% CI, 0.45-0.91], P=0.013) decreased that likelihood. CONCLUSIONS: In propensity score-matched Japanese NIHF patients, the incidence of appropriate ICD therapy and ES was significantly higher in SP than PP patients. Impaired renal function in SP patients and anemia in PP patients increased the likelihood of appropriate ICD therapy, whereas long-lasting atrial fibrillation reduced that likelihood in PP patients.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Atrial Fibrillation / Defibrillators, Implantable / Heart Failure / Cardiomyopathies Limits: Humans Language: En Journal: Circ J Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2022 Type: Article

Full text: 1 Database: MEDLINE Main subject: Atrial Fibrillation / Defibrillators, Implantable / Heart Failure / Cardiomyopathies Limits: Humans Language: En Journal: Circ J Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2022 Type: Article