Your browser doesn't support javascript.
loading
Absorbed dose evaluation of a blood irradiator with alanine, TLD-100 and ionization chamber.
Grasso, S; Varallo, A; Ricciardi, R; Italiano, M E; Oliviero, C; D'Avino, V; Feoli, C; Ambrosino, F; Pugliese, M; Clemente, S.
Affiliation
  • Grasso S; Post Graduate School in Medical Physics, University of Naples Federico II, 80131, Naples, Italy.
  • Varallo A; Post Graduate School in Medical Physics, University of Naples Federico II, 80131, Naples, Italy; National Institute of Nuclear Physics, 80126, Naples, Italy.
  • Ricciardi R; Post Graduate School in Medical Physics, University of Naples Federico II, 80131, Naples, Italy; National Institute of Nuclear Physics, 80126, Naples, Italy.
  • Italiano ME; Post Graduate School in Medical Physics, University of Naples Federico II, 80131, Naples, Italy.
  • Oliviero C; Unit of Medical Physics and Radioprotection, A.O.U Policlinico Federico II, 80131, Naples, Italy.
  • D'Avino V; Department of Physics "E. Pancini", University of Naples Federico II, 80126, Naples, Italy.
  • Feoli C; Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131, Naples, Italy.
  • Ambrosino F; Department of Physics "E. Pancini", University of Naples Federico II, 80126, Naples, Italy.
  • Pugliese M; Department of Physics "E. Pancini", University of Naples Federico II, 80126, Naples, Italy. Electronic address: mpuglies@na.infn.it.
  • Clemente S; Unit of Medical Physics and Radioprotection, A.O.U Policlinico Federico II, 80131, Naples, Italy.
Appl Radiat Isot ; 200: 110981, 2023 Oct.
Article in En | MEDLINE | ID: mdl-37633189
ABSTRACT
Irradiation of blood bags using X-ray irradiators and dosimetry services are required to ensure uniform dose levels in the range 25-50 Gy to prevent Transfusion Associated Graft versus Host Disease (TA-GvHD). An absorbed dose characterization of a Raycell MK2 X-Irradiator was performed using three different dosimetric systems. Results showed a dosimetric accuracy of the ionization chamber together with the Alanine dosimeter. TLDs measurements exhibited a small overestimation by 4% of the absorbed dose. The Dose Uniformity Ratio (DUR), between maximum and minimum dose levels in the canister, was in good agreement with the manufacturer specifications (≤1.5).
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Alanine / Radiation Dosimeters Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2023 Type: Article Affiliation country: Italy

Full text: 1 Database: MEDLINE Main subject: Alanine / Radiation Dosimeters Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2023 Type: Article Affiliation country: Italy