Your browser doesn't support javascript.
loading
Establishment and methodological evaluation of a chemiluminescence assay for detection of anti-envelope protein (E1, E2) antibodies in the serum of hepatitis C virus-infected patients.
Wang, Ningning; Liu, Qingqing; Che, Feihu; Sun, Qingyang; Wang, Yue; Yang, Chunli; Dai, Yuzhu; Cheng, Jun.
Affiliation
  • Wang N; School of Laboratory Medicine, Bengbu Medical College, Bengbu, China.
  • Liu Q; School of Laboratory Medicine, Bengbu Medical College, Bengbu, China.
  • Che F; Department of Clinical Research, The 903rd Hospital of PLA, Hangzhou, China.
  • Sun Q; Department of Clinical Research, The 903rd Hospital of PLA, Hangzhou, China.
  • Wang Y; Department of Clinical Research, The 903rd Hospital of PLA, Hangzhou, China.
  • Yang C; Department of Clinical Research, The 903rd Hospital of PLA, Hangzhou, China.
  • Dai Y; Department of Clinical Research, The 903rd Hospital of PLA, Hangzhou, China.
  • Cheng J; Department of Clinical Research, The 903rd Hospital of PLA, Hangzhou, China.
J Clin Lab Anal ; 38(4): e25011, 2024 Feb.
Article in En | MEDLINE | ID: mdl-38491776
ABSTRACT

BACKGROUND:

To establish a chemiluminescence method for detecting anti-E1 and anti-E2 antibodies in the serum of patients with hepatitis C virus (HCV) infection.

METHODS:

The microplate was coated with recombinant envelope proteins E1 and E2 by indirect method, respectively, and the kits for detecting anti-E1 and anti-E2 antibodies were prepared. The methodological indexes were evaluated.

RESULTS:

The methodological indexes of the kits were as follows precision test (the variation coefficient of anti-E1 antibody 6.71%-8.95% for within run and 9.91%-12.16% for between run, the variation coefficient of anti-E2 antibody 6.06%-8.44% for within run and 10.77%-13.98% for between run, respectively). The blank limit and detection limit were 1.18 RLIR and 3.16 RLIR for the anti-E1 antibody, and 1.26 RLIR and 3.32 RLIR for the anti-E2 antibody, respectively. The correlation coefficients (r) of anti-E1 and anti-E2 were 0.9963 and 0.9828, the analysis and measurement ranges (AMR) were 1.66-41.28 RLIR and 1.55-19.46 RLIR, and the average recovery was 96.4% and 93.7%, respectively. The rheumatoid factor and other positive serum samples had no interference or cross-reaction to the test, and the kits were stable within 15 months. The positive rates of anti-E1 and anti-E2 antibodies in 45 patients with HCV infection were 35.6% (16/45) and 44.4% (20/45), respectively.

CONCLUSIONS:

The kits for detecting anti-E1 and anti-E2 meet the requirements of methodology, and can be used in screening diagnosis, disease monitoring, prognosis evaluation, disease mechanism, and epidemiological studies of HCV infection. The HCV envelope proteins E1 and E2 have an immune response in HCV-infected patients.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Hepatitis C / Hepacivirus Limits: Humans Language: En Journal: J Clin Lab Anal Journal subject: TECNICAS E PROCEDIMENTOS DE LABORATORIO Year: 2024 Type: Article Affiliation country: China

Full text: 1 Database: MEDLINE Main subject: Hepatitis C / Hepacivirus Limits: Humans Language: En Journal: J Clin Lab Anal Journal subject: TECNICAS E PROCEDIMENTOS DE LABORATORIO Year: 2024 Type: Article Affiliation country: China