Occupational exposure to high frequency electromagnetic fields and its effect on human immune parameters.
Int J Occup Med Environ Health
; 12(3): 239-51, 1999.
Article
en En
| MEDLINE
| ID: mdl-10581865
The present study recorded a considerable excess of recommended exposure limits in the vicinity of shortwave diathermy devices used for medical treatment of patients. Different kinds of field probes were used to measure electric and magnetic field strength and the whole body exposure of medical personnel operating shortwave, decimeter wave and microwave units was calculated. To investigate the influence of chronic exposure on the immune system of operators, blood was sampled from physiotherapists working at the above mentioned devices. Eighteen exposed and thirteen control persons, matched by sex and age, were examined. Total leucocyte and lymphocyte counts were performed and leucocytic subpopulations determined by flow cytometry and monoclonal antibodies against surface antigens. In addition, to quantify subpopulations of immunocompetent cells, the activity of lymphocytes was measured. Lymphocytes were stimulated by mitogen phytohemagglutinin and their proliferation measured by a flow cytometric method. No statistically significant differences between the control and exposed persons were found. In both study groups all immune parameters were within normal ranges.
Buscar en Google
Bases de datos:
MEDLINE
Asunto principal:
Exposición Profesional
/
Campos Electromagnéticos
/
Inmunidad
Tipo de estudio:
Observational_studies
Límite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
País/Región como asunto:
Europa
Idioma:
En
Revista:
Int J Occup Med Environ Health
Asunto de la revista:
MEDICINA OCUPACIONAL
/
SAUDE AMBIENTAL
Año:
1999
Tipo del documento:
Article
País de afiliación:
Austria