Your browser doesn't support javascript.
loading
Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice.
Badea, Cristian T; Hedlund, Laurence W; Mackel, Julie F Boslego; Mao, Lan; Rockman, Howard A; Johnson, G Allan.
Afiliación
  • Badea CT; Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC, USA. chris@orion.duhs.duke.edu
Mol Imaging ; 6(4): 261-8, 2007.
Article en En | MEDLINE | ID: mdl-17711781
ABSTRACT
The purpose of this study was to investigate the use of micro-computed tomography (micro-CT) for morphological and functional phenotyping of muscle LIM protein (MLP) null mice and to compare micro-CT with M-mode echocardiography. MLP null mice and controls were imaged using both micro-CT and M-mode echocardiography. For micro-CT, we used a custom-built scanner. Following a single intravenous injection of a blood pool contrast agent (Fenestra VC, ART Advanced Research Technologies, Saint-Laurent, QC) and using a cardiorespiratory gating, we acquired eight phases of the cardiac cycle (every 15 ms) and reconstructed three-dimensional data sets with 94-micron isotropic resolution. Wall thickness and volumetric measurements of the left ventricle were performed, and cardiac function was estimated. Micro-CT and M-mode echocardiography showed both morphological and functional aspects that separate MLP null mice from controls. End-diastolic and -systolic volumes were increased significantly three- and fivefold, respectively, in the MLP null mice versus controls. Ejection fraction was reduced by an average of 32% in MLP null mice. The data analysis shows that two imaging modalities provided different results partly owing to the difference in anesthesia regimens. Other sources of errors for micro-CT are also analyzed. Micro-CT can provide the four-dimensional data (three-dimensional isotropic volumes over time) required for morphological and functional phenotyping in mice.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Proteínas Musculares / Miocardio Límite: Animals Idioma: En Revista: Mol Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2007 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Proteínas Musculares / Miocardio Límite: Animals Idioma: En Revista: Mol Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2007 Tipo del documento: Article País de afiliación: Estados Unidos