Failed tracheal intubation with the LMA-CTrach in two patients with lingual tonsil hyperplasia.
Ojeda, Antonio; López, Ana M; Borrat, Xavier; Valero, Ricard.
Afiliación
  • Ojeda A; Anesthesiology Department, Hospital Clínic of Barcelona, Villarroel 170, 08036 Barcelona, Spain.
Anesth Analg ; 107(2): 601-2, 2008 Aug.
Article en En | MEDLINE | ID: mdl-18633038
ABSTRACT
The LMA-CTrach combines the features of the Intubating Laryngeal Mask Airway with a fiberoptic system and a screen for visualization of the airway. Local pathology, such as lingual tonsillar hyperplasia, may obstruct the view of the airway leading to unanticipated difficult intubation. We present two cases of failed intubation with the LMA-CTrach in patients with lingual tonsillar hyperplasia. In both cases, the LMA-CTrach maintained adequate ventilation, giving time to prepare alternative strategies.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tonsila Palatina / Máscaras Laríngeas / Intubación Intratraqueal Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Anesth Analg Año: 2008 Tipo del documento: Article País de afiliación: España