Your browser doesn't support javascript.
loading
Clinical impact of new prostate-specific antigen WHO standardization on biopsy rates and cancer detection.
Jansen, F H; Roobol, M; Bangma, C H; van Schaik, R H N.
Afiliación
  • Jansen FH; Department of Urology, Erasmus MC, Rotterdam, The Netherlands.
Clin Chem ; 54(12): 1999-2006, 2008 Dec.
Article en En | MEDLINE | ID: mdl-18927249
ABSTRACT

BACKGROUND:

Clinicians may be unaware that replacement of the historical total prostate-specific antigen (tPSA) standard with the WHO 96/670 international standard leads to difficulties in interpreting tPSA results. Our aim was to investigate the relationship between the Hybritech and WHO calibrations of the Beckman Coulter tPSA assay, and to assess the impact on prostate cancer (PCa) detection.

METHODS:

tPSA concentrations were measured in 106 serum samples with both Hybritech and WHO calibrations. The established relationships were used for an in silico experiment with a cohort of 5865 men. Differences in prostate biopsy rates, PCa detection, and characteristics of missed cancers were calculated at biopsy thresholds of 3.0 and 4.0 microg/L.

RESULTS:

A linear relationship was observed between the 2 calibrations, with a 20.3% decrease in tPSA values with the WHO standard compared with the Hybritech calibration. Applying the WHO calibration to the cohort of 5865 men yielded a 20% or 19% decrease in prostate biopsies and a 19% or 20% decrease in detected cancers compared with the Hybritech calibration, at a cutoff for biopsy of 3.0 or 4.0 microg/L, respectively. The decrease in detected cancers declined to 9% or 11% if an abnormal result in a digital rectal examination or a transrectal ultrasound evaluation was used as trigger for prostate biopsy (cutoff of 3.0 or 4.0 microg/L, respectively).

CONCLUSIONS:

Application of the WHO standard for tPSA assays with commonly used tPSA thresholds leads to a significant decrease in PCa detection. Careful assessment of the relationship between the WHO standard and the thresholds used for prostate biopsy is hence necessary.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Antígeno Prostático Específico Tipo de estudio: Diagnostic_studies Límite: Humans / Male Idioma: En Revista: Clin Chem Asunto de la revista: QUIMICA CLINICA Año: 2008 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Antígeno Prostático Específico Tipo de estudio: Diagnostic_studies Límite: Humans / Male Idioma: En Revista: Clin Chem Asunto de la revista: QUIMICA CLINICA Año: 2008 Tipo del documento: Article País de afiliación: Países Bajos